• Title/Summary/Keyword: earthquake research information

Search Result 228, Processing Time 0.024 seconds

Seismic Studies on Ground Motion using the Multicomponent Complex Trace Analysis Method (다성분 복소 트레이스 분석법을 이용한 지진파 입자운동 연구)

  • Lee, So-Young;Kim, Ki-Young;Kim, Han-Joon
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.1
    • /
    • pp.37-48
    • /
    • 2000
  • In order to investigate in-line ground motions caused by earthquakes, we examine the multicomponent complex trace analysis method (MCTAM) for the synthetic data and apply it to real earthquake data. An experimental result for synthetic data gives correct information on the arrival times, duration of individual phases, and approaching angles for body waves. Rayleigh waves are also easily identified with the MCTAM. A deep earthquake with magnitude of 7.3 was chosen to test various polarization attributes of ground motions. For P waves, instantaneous phase difference between the vertical and the in-line horizontal components ${\phi}(t)$, instantaneous reciprocal ellipticity ${\rho}(t)$, and approaching angle ${\tau}(t)$ are computed to be ${\pm}180^{\circ},\;0{\sim}0.25,\;and\;-30^{\circ}{\sim}-45^{\circ}$, respectively. For S waves, ${\phi}(t)$ tends to vary while ${\rho}(t)$ have values of $0{\sim}0.3\;and\;{\tau}(t)$ remains near vertical, respectively. A relatively low frequency signal registered just prior to the S wave event is interpreted as a P-wave phase based on its polarization characteristics. Velocities of P and S waves are computed to be 8.633 km/s and 4.762 km/s, and their raypath parameters 0.074 s/km and 0.197 s/km. Dynamic Poisson's ratio is obtained as 0.281 from the velocities of P and S waves.

  • PDF

Electric and Electromagnetic Surveys of the Hongseong Fault Zone (홍성 단층대에서의 전기, 전자 탐사 연구)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Park, Gye-Soon;Oh, Seok-Hoon;Lee, Choon-Ki
    • Journal of the Korean earth science society
    • /
    • v.24 no.4
    • /
    • pp.361-368
    • /
    • 2003
  • We have investigated the electric resistivity structure of the fault zone located in the Hongseong area where a big earthquake with M 5.0 occurred in 1978. Usually, Electric and Electromagnetic methods are broadly operated in the field of engineering works since these methods are effective to understand the distribution of geological weak zones - fault or fracture zones. We have conducted the dipole-dipole array resistivity method and MT(magnetotelluric) method and interpreted the resistivity distribution of the fault zone with the aid of various inversion methods. An MT survey was performed at 18 points along a 2.9 km survey line perpendicular to the fault line and a magnetic dipole source was used to enhance the S/N ratio in the high frequency. A Electric dipole-dipole array resistivity survey with the dipole length of 50 meters was carried out perpendicular to the fault. In view of two survey results, the fault marks the boundary between two opposite resistivity structures, especially the low resistivity zone is exhibited deeply through the prospective fault line. The result that the low resistivity zone is located at the center of the fault zone corresponds with the fact that the fault zone of the Hongseong area is active. We expect these results to provide basic information about the physical properties of fault zones in Korea.

Establishment of Complex Disaster Scenario on the Utility Tunnel Study for Digital Twin System Application (디지털트윈 시스템 적용을 위한 공동구 복합재난 시나리오 구축)

  • Yon Ha Chung; So Dam Kim;Hyun Jeong Seo;Hojun Lee;Tae Jung Song
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.861-872
    • /
    • 2022
  • The purpose of this study was to establish a complex disaster scenario that can comprehensively consider various disaster situations that may occur in the utility tunnel. Method: In order to comprehensively consider the correlation between disasters, a composite disaster scenario was derived from a combination of damage factors, respectively. A risk assessment was performed in order to derive the priorities of the scenarios. And based on the results, the priorities of complex disaster scenarios were set. Result: Based on the disaster cases in the utility tunnel, a plan was prepared for complex disaster scenarios centered on damage. A complex disaster scenario was specified using a semi-quantitative evaluation method for single and multiple disaster factors such as fire, flooding, and earthquake. Conclusion: The composite disaster scenario derived from this study can be used for the prevention and preparation of damage when the precursor symptoms of a disaster are detected. In addition, the results of this study are expected to be used as basic data for preparing strategic plans and preparing complex disaster response technologies to induce rapid response and recovery in case of emergency disasters.

Seismic Analysis of Nuclear Power Equipment Related to Design (원전기자재 설계와 관련된 내진해석)

  • Lee, Woo-Hyung;Cho, Jong-Rae;Roh, Min-Sik;Ryu, Jeong-Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.3
    • /
    • pp.317-323
    • /
    • 2011
  • We use the finite element method to analyze the seismic design of a liquid storage tank for a polar crane at a nuclear power plant. We obtained the natural frequency and vibration modes by modal analysis, and we evaluated the seismic stability by response spectrum analysis. Furthermore, the seismic analysis of the tank was accomplished by analyzing not only the forces applied to the wall by the sloshing of the liquid, but also the safe-shutdown earthquake condition for the tank. We propose a seismic-design process and a seismic-analysis method for liquid storage tanks based on the commercial finite element analysis program, ANSYS.

Improvement in the Simulation of Wind Fields Over the Complex Coastal Area, Korea (한반도 복잡 해안지역의 바람장 모의 개선)

  • Kim, Yoo-Keun;Bae, Joo-Hyun;Jeong, Ju-Hee;Kweon, Ji-Hye;Seo, Jang-Won;Kim, Yong-Sang
    • Journal of Environmental Science International
    • /
    • v.15 no.5
    • /
    • pp.417-430
    • /
    • 2006
  • We focused on improvement in simulation of wind fields for the complex coastal area. Local Analysis and Prediction System(LAPS) was used as a data assimilation method to improve initial conditions. Case studies of different LAPS inputs were performed to compare improvement of wind fields. Five cases have been employed : I) non data assimilation, II) all available data, III) AWS, buoy, QuikSCAT, IV) AWS, buoy, wind profiler, V) AWS, buoy, AMEDAS. Data assimilation can supplement insufficiency of the mesoscale model which does not represent detailed terrain effect and small scale atmospheric flow fields. Result assimilated all available data showed a good agreement to the observations rather than other cases and estimated veil the local meteorological characteristics including sea breeze and up-slope winds. Result using wind profiler data was the next best thing. This implies that data assimilation with many high-resolution sounding data could contribute to the improvements of good initial condition in the complex coastal area. As a result, these indicated that effective data assimilation process and application of the selective LAPS inputs played an important role in simulating wind fields accurately in a complex area.

A case study of damage detection in four-bays steel structures using the HHT approach

  • Hsu, Wen-Ko;Chiou, Dung-Jiang;Chen, Cheng-Wu;Liu, Ming-Yi;Chiang, Wei-Ling;Huang, Pei-Chiung
    • Smart Structures and Systems
    • /
    • v.14 no.4
    • /
    • pp.595-615
    • /
    • 2014
  • This study aims to investigate the relationship between structural damage and sensitivity indices using the Hilbert-Huang transform (HHT) method. Two damage detection indices are proposed: the ratio of bandwidth (RB), and the ratio of effective stiffness (RES). The nonlinear four bays multiple degree of freedom models with various predominant frequencies are constructed using the SAP2000 program. Adjusted PGA earthquake data (Japan 311, Chi-Chi 921) are used as the excitations. Next the damage detection indices obtained using the HHT and the fast Fourier transform (FFT) methods are evaluated based on the acceleration responses of the structures to earthquakes. Simulation results indicate that, the column of the 1 st floor is the first yielding position and the RB value is changed when the RES<90% in all cases. Moreover, the RB value of the 1 st floor changes more sensitive than those from the top floor. In addition, when the structural response is nonlinear (i.e., RES<100%), the RB and the RES curves indicate the incremental change in the HHT spectra. However, the same phenomenon can be found from FFT spectra only when the stiffness reduction is large enough. Therefore, the RB estimated from the smoothed HHT spectra is an effective and sensitive index for detecting structural damage.

An Attempt of Estimation of Annual Fog Frequency over Gyeongsangbuk-do of Korea Using Weather Generator MM5

  • Kim, Do-Yong;Oh, Jai-Ho;Kim, Jin-Young;Sen, Pumendranath;Kim, Tae-Kook
    • Environmental Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.88-94
    • /
    • 2009
  • In this study an attempt has been made to predict the annual foggy days over Gyeongsangbuk-do of Korea, using the regional mesoscale model (MM5). The annual meteorological conditions are simulated, and the annual and seasonal foggy days are predicted from the simulated results based on the seasonal and spatial information of the observed meteorological characteristics for fog occurrence such as wind speed, relative humidity, and temperature. Most of observed inland fog over Gyeongsangbuk-do occurs in autumn under the meteorological conditions such as a cairn, a high temperature range (above $10^{\circ}C$), and a high relative humidity (above 85%). The predicted results show the various foggy days, about 10${\sim}$60 days, depending on the season and the site locations. The predicted annual foggy days at inland sites are about 30${\sim}$60 days, but at coastal sites, about 10${\sim}$20 days. Also, a higher frequency of fog occurrence at inland sites is shown in autumn (about 60% of the annual foggy days). Otherwise, a higher frequency of fog occurrence at coastal sites is shown in summer (about 60% of the annual foggy days), unlike the inland. These annual foggy days and their seasonal variations agree reasonably well with the observed values. It can be concluded that it is possible to predict the occurrence of annual or seasonal foggy days by MM5.

Improvements in the Simulation of Sea Surface Wind Over the Complex Coastal Area-II: Data Assimilation Using LAPS (복잡 해안지역 해상풍 모의의 정확도 개선-II: LAPS를 사용한 자료동화)

  • Bae, Joo-Hyun;Kim, Yoo-Keun;Jeong, Ju-Hee;Kweon, Ji-Hye;Seo, Jang-Won;Kim, Yong-Sang
    • Journal of Environmental Science International
    • /
    • v.15 no.8
    • /
    • pp.745-757
    • /
    • 2006
  • We focus on the improvement of accuracy of sea surface wind over complex coastal area doling the warm season. Local Analysis Prediction System (LAPS) was used to improve the initial values in Mesoscale Meteorological model (MM5). During the clear summer days with weak wind speed, sea surface wind simulated with LAPS was compared with the case without LAPS. The results of modeling with LAPS has a good agreement mesoscale circulation such as mountain and valley winds on land and in case of modeling without LAPS, wind speed overestimated over the sea in the daytime. And the results of simulation with LAPS indicated similar wind speed values to observational data over the sea under influence of data assimilation using BUOY, QuikSCAT, and AMEBAS. The present study suggests that MM5 modelling with LAPS showed more improved results than that of without LAPS to simulate sea surface wind over the complex coastal area.

Improvements in the simulation of sea surface wind over the complex coastal area- I : Assessment of current operational model (복잡 해안지역 해상풍 모의의 정확도 개선- I : 현업모델의 평가)

  • Bae Joo-Hyun;Kim Yoo-Keun;Oh In-Bo;Jeong Ju-Hee;Kweon Ji-Hye;Seo Jang-Won
    • Journal of Environmental Science International
    • /
    • v.14 no.7
    • /
    • pp.657-667
    • /
    • 2005
  • In this study, we focused on the improvements in the simulation of sea surface wind over the complex coastal area. MM5 model being currently used to predict sea surface wind at Korea Meteorological Administration, was used to verify the accuracy to estimate the local wind field. A case study was performed on clear days with weak wind speed(4 m/s), chosen by the analysis of observations. The model simulations were conducted in the southeastern area of Korea during the selected periods, and observational data such as AWS, buoy and QuikSCAT were used to compare with the calculated wind components to investigate if simulated wind field could follow the tendency of the real atmospheric wind field. Results showed that current operational model, MM5, does not estimate accurately sea surface wind and the wind over the coastal area. The calculated wind speed was overestimated along the complex coastal regions but it was underestimated in islands and over the sea. The calculated diurnal changes of wind direction could not follow well the tendency of the observed wind, especially at nighttime. In order to exceed the limitations, data assimilation with high resolution data and more specificated geographical information is expected as a next best policy to estimate accurately the environment of local marine wind field.

Modeling of composite MRFs with CFT columns and WF beams

  • Herrera, Ricardo A.;Muhummud, Teerawut;Ricles, James M.;Sause, Richard
    • Steel and Composite Structures
    • /
    • v.43 no.3
    • /
    • pp.327-340
    • /
    • 2022
  • A vast amount of experimental and analytical research has been conducted related to the seismic behavior and performance of concrete filled steel tubular (CFT) columns. This research has resulted in a wealth of information on the component behavior. However, analytical and experimental data for structural systems with CFT columns is limited, and the well-known behavior of steel or concrete structures is assumed valid for designing these systems. This paper presents the development of an analytical model for nonlinear analysis of composite moment resisting frame (CFT-MRF) systems with CFT columns and steel wide-flange (WF) beams under seismic loading. The model integrates component models for steel WF beams, CFT columns, connections between CFT columns and WF beams, and CFT panel zones. These component models account for nonlinear behavior due to steel yielding and local buckling in the beams and columns, concrete cracking and crushing in the columns, and yielding of panel zones and connections. Component tests were used to validate the component models. The model for a CFT-MRF considers second order geometric effects from the gravity load bearing system using a lean-on column. The experimental results from the testing of a four-story CFT-MRF test structure are used as a benchmark to validate the modeling procedure. An analytical model of the test structure was created using the modeling procedure and imposed-displacement analyses were used to reproduce the tests with the analytical model of the test structure. Good agreement was found at the global and local level. The model reproduced reasonably well the story shear-story drift response as well as the column, beam and connection moment-rotation response, but overpredicted the inelastic deformation of the panel zone.