• Title/Summary/Keyword: early-aged concrete,

Search Result 48, Processing Time 0.032 seconds

Correlation between Longitudinal Wave Velocity and Strength of Early-aged Concrete (초기 재령 콘크리트의 종파 속도와 강도의 상관관계)

  • 이휘근;이광명;김동수
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.67-74
    • /
    • 2000
  • The usage of nondestructive testing on early-aged concrete leads to enhacned safty and allows effective scheduling of construction, thus making it possible to maximize the time and cost efficiencies. In this study, a reliable nondestructive strength evaluation method for early-aged concrete using the longitudinal wave velocity is proposed. Compression tests were performed to examine factors influencing the velocity-strength relationship of concrete, such as water-cement (w/c) ratio, fine aggregate ratio, curing temperature, and curing condition. The test results show that a change in the w/c ratio and curing temperature has minor effect on the velocity-strength relationship/ However, curing condition significantly influences the velocity-strength relationship of early-aged concrete. Moreover, the longitudinal wave velocity increases with decreasing fine aggregate ratio. It is concluded from this study that the strength evaluation of early-age concrete can be achieved by a nonlinear equation which considers the effects of curing condition and fine aggregate ratio.

A Study on Crack Control of Early-aged Reinforced Concrete Rahmen Bridge (초기재령 철근큰크리트 라멘교의 균열제어에 관한 연구)

  • Jung Hee-Hyo;Lee Sung-Yeol;Kim Woo-Jung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.1 s.71
    • /
    • pp.15-25
    • /
    • 2006
  • The researches on the early-aged concrete hydration process and the techniques for the early-aged concrete crack control mainly have been focused and developed on the massive concretes in both experimental and numerical studies. However, those researches for relatively thin members such as the upper slab of the reinforced concrete rahmen bridge have nearly been attempted. In this study, a designing technique for crack controlling in the thin members of the early-aged reinforced concrete rahmen bridges based on measured temperature history, strength revelation model and sinkage model is proposed. A method of calculating the reinforcing bar area for crack controlling is also proposed and it is found that the distributing bars under the design loads become the main reinforcing bars in the temperature stress analysis of the early-aged reinforced concrete rahmen bridges. It is shown that the proposed analysis technique is able to use the design of crack control for the early-aged reinforced concrete rahmen bridge.

An Analytic Study on Early aged Freezing Damage Prevention and Thermal Crack Control of Concrete in Cold-Weathering Mat Foundation Construction (동절기 매트기초공사시 콘크리트의 초기동해방지 및 온도충격제어에 관한 해석적 연구)

  • 이도범;김효락;박지훈;최일호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.807-812
    • /
    • 2001
  • This study is peformed for checking the limitation and application of each curing/heating methods on cold-weathering mat foundation construction, considering temperature control, early strength security and temperature declination range limit, by means of concrete material properties and thermal analysis technique that were published previously. In the result of this analysis, we checked the open air temperature and mat depth that are possible to apply each curing/heating methods on cold-weathering construction and found curing/heating time of each methods that is able to prevent early aged freezing damage and thermal crack

  • PDF

A Site Application of the Revealing High Early Strength Concrete (조기강도 발현형 콘크리트의 현장 적용성 연구)

  • Kim Gyu Dong;Lee Seung Hoon;Sohn Yu Shin;Kim Han Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.560-563
    • /
    • 2004
  • This study reports the site application of concrete using AE Water Reducing Agent of Early-Strength Type. According to the lab test results, we have made plans of batch plant pilot test, and we have analyzed the erly aged compressive strength and workability of the concrete. We applied the early-strength development concrete to the construction site. We accomplished the slump test in order to evaluate the workablity and air contents, we made site curing mold to evaluate the early strength of members. As a result, we judgeed the superior property of early strength development of the concrete, and thought that we can reduce the time of form stripping more $40\%$ than ordinary strength concrete. We thought that we can reduce the term of works and finally we can accomplish the economical construction.

  • PDF

Durability Performance Evaluation On Early-Aged Concrete with Rice Husk Ash and Silica Fume (Rice Husk Ash와 실리카퓸을 혼입한 초기재령 콘크리트의 내구성능 평가)

  • Saraswathy, Velu;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.343-351
    • /
    • 2015
  • Currently, lots of researches have been performed for reducing cement usages due to increasing social/engineering problems caused by $CO_2$ emission. Supplementary cement materials like fly ash, slag, and silca fume are usually employed for cement replacement, and nowadays rice husk ash (RHA) is widely studied for enhancement of concrete performance as mineral admixture. In this paper, concrete samples with RHA and SF which is known for its engineering advantages are prepared and a resistance to chloride attack is evaluated in early-aged concrete. For the work, replacement ratios of 10~30% for RHA concrete and 2~8% for SF concrete are considered, and various durability tests such as density, void, sorptivity, current measurement, and chloride diffusion coefficient are performed including mechanical test like compressive and tensile strength. Replacement of RHA 10~15% shows better improvement of corrosion resistance and strength than that of SF 2~4% and normal concrete, which shows a strong applicability for utilization as construction materials.

Transient heat transfer analysis using Galerkin finite element method for reinforced concrete slab exposed to high elevated temperature

  • Han, Byung-Chan;Kwon, Young-Jin;Lee, Byung-Jae;Kwon, Seung-Jun;Chae, Young-Suk
    • Computers and Concrete
    • /
    • v.18 no.6
    • /
    • pp.1097-1112
    • /
    • 2016
  • Fire loading causes a critical collapse of RC (Reinforced Concrete) Structures since the embedded steels inside are relative week against high elevated temperature. Several numerical frameworks for fire resistance have been proposed, however they have limitations such as unstable convergence and long calculation period. In the work, 2-D nonlinear FE technique is proposed using Galerkin method for RC structures under fire loading. Closed-form element stiffness with a triangular element is adopted and verified with fire test on three RC slabs with different fire loading conditions. Several simulations are also performed considering fire loading conditions, water contents, and cover depth. The proposed numerical technique can handle time-dependent fire loading, convection, radiation, and material properties. The proposed technique can be improved through early-aged concrete behavior like moisture transport which varies with external temperature.

Study of thin film transition liquid crystal display (TFT-LCD) optical waste glass applied in early-high-strength controlled low strength materials

  • Wang, Her-Yung;Chen, Jyun-Sheng
    • Computers and Concrete
    • /
    • v.5 no.5
    • /
    • pp.491-501
    • /
    • 2008
  • The present study verifies compressive strength, ultrasonic pulse velocity, electrical resistance,permeable ratio, and shrinkage from waste glass controlled low strength materials (WGCLSM) and early-high-strength WGCSLM specimens, by replacing the sand with waste glass percentages of 0%, 10%,20%, and 30%. This study reveals that increasing amounts of waste LCD glass incorporated into concrete increases WGCLSM fluidity and reduces the setting time, resulting in good working properties. By increasing the glass to sand replacement ratio, the compressive strength decreases to achieve low-strength effects. Furthermore, the electrical resistance also rises as a result of increasing the glass to sand replacement ratio. Early-high-strength WGCSLM aged 28 days has twice the electrical resistance compared to general WGCSLM. Early-high-strength WGCSLM aged 7 days has a higher ultrasonic pulse velocity similar to WGCSLM aged 28 days. The variation of length with age of different compositions is all within the tolerance range of 0.025%. This study demonstrates that the proper composition ratio of waste LCD glass to sand in early-high-strength WGCSLM can be determined by using different amounts of glass-sand. A mechanism for LCD optical waste glass usage can be established to achieve industrial waste minimization, resource recycling, and economic security.

Optimal Sawcutting Methods for Hydrating Concrete Pavements

  • Jeong, Jin-Hoon;Kim, Sung-Hee;Kim, Nakseok
    • KCI Concrete Journal
    • /
    • v.14 no.3
    • /
    • pp.93-101
    • /
    • 2002
  • The details of an approach to account for the factors that have been found to affect the ability and the probability to control cracking due to sawcutting in newly constructed concrete pavements are presented. Several factors such as material strength parameters, method and quality of curing, slab and subbase stiffness, and concrete shrinkage affect the probability of crack initiation. Others are relevant to concrete mixture characteristics that affect development of early aged stresses caused by shrinkage and thermally induced contraction. This paper presents the results of a probabilistic analysis of the factors that affect crack control using sawcut notches. Cost analyses on both conventional and early-entry sawcutting methods are shown to support the results of the probabilistic analysis. From both an operational and cost standpoint, it is evident for the environmental conditions considered that early-entry sawcut methodology holds a significant advantage over conventional methods.

  • PDF

Experimental Fatigue Performance of Concrete Slab with I-shaped Steel (I 형강 격자 상판의 피로 성능에 관한 실험적 연구)

  • 박창규;김용곤;김철환;이재형;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.541-546
    • /
    • 2000
  • Recently, there have been increased mush concerns about repair and rehabilitation works for aged concrete structures to keep up with rapid economic growth in Korea since the early 1970's. In particular, it is believed in these days that there are significantly increasing number of aged concrete bridge slabs, which are strongly needed to construct and rehabilitate by innovative construction method. The objective of this research is to develop the new construction method of concrete slab in bridge structure, which can contribute to minimize the traffic congestion during the repair and rehabilitation works of aged concrete slab, and can also sufficiently assure the quality through the minimization of in-situ works at the site. I-beams with punch holes, which are substituted instead of main reinforcing steels in concrete slabs, will be manufactured in accordance with the specification in the factory, and will be preassembled into the panel. After erecting the preassembled panels in the site, concrete will be poured into the slab panel. This test is to investigate physical properties of I-Beam with punch holes itself, and then to investigate structural properties of assembled I-Beam panels through static and fatigue test, of which can be utilized for the development of new construction method of concrete slab in bridge structure.

  • PDF

An Experimental Study on Temperature Analysis Method of Concrete in Cold-Weathering Concrete Constructions (동절기 콘크리트공사시 콘크리트의 온도해석기법에 관한 실험적 연구)

  • 이도범;김효락;박지훈;최일호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.801-806
    • /
    • 2001
  • In the latest, the construction period became the most important factor in the domestic building works because buildings is higher and larger gradually. Accordingly, cold-weathering concrete constructions are performed more and more. So, the demands of concrete quality management methods are increased in cold-weathering concrete constructions. In this study, the mock-up experiment was performed to correct input data in the kimpo H construction field. Using the results of this experiment, the method of temperature analysis was presented to prevent early aged freezing damage and to control thermal crack in this study.

  • PDF