• Title/Summary/Keyword: early-age concrete

Search Result 584, Processing Time 0.026 seconds

Assessment of Early-age Properties of Mortar by Monitoring of Ultrasonic Pulse Velocity (초음파 속도 모니터링에 의한 모르터의 초기재령 특성 평가)

  • 이회근;이광명
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.245-250
    • /
    • 2001
  • Ultrasonic pulse velocity(UPV) is a useful tool for examining the property of early-age mortar or concrete. Thus, UPV has been used for a long time to characterize setting and hardening of cementitious materials. In this study, in order to investigate the characteristics of setting for mortar, UPV was measured using automatic monitoring system up to 3 days after casting. Test results show that UPV of high water to binder ratio(w/b) mortar remained constant at the beginning of hydration and then abruptly began to increase. However, UPV of low w/b mortar gradually increase due to setting retard caused by use of superplasticizer. Furthermore, the development of UPV for mortar with fly ash is slower than that of mortar without fly ash. It was concluded that the property change of mortar or concrete, such as setting and hardening can be assessed by monitoring of UPV.

  • PDF

Monitoring of Early-age Behavior of concrete cable-stayed girder bridge by FBG sensors (FBG 센서를 이용한 사장교 초기재령 특성 모니터링 연구)

  • Jang, Il-Young;Park, Seung-Min;Kim, Seong-Kyum;Yang, Jae-Yeol;Park, Joon-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.105-106
    • /
    • 2010
  • FBG temperature sensor and strain sensor has been used to monitoring shrinkage and temperature of concrete cable-stayed girder bridge site in its casting early age, The monitoring method using this study is expected to used a practical method.

  • PDF

Effect of Hydration Heat Evolution on Autogenous Shrinkage of High Strength Concrete (초기수화발열이 고강도콘크리트의 자기수축특성에 미치는 영향)

  • 정해문;도변박지;하야도륭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.95-100
    • /
    • 2003
  • The shrinkage of high strength/high performance concrete is very important property for the good working of a structure since it very often generates early age cracking due to thermal and autogenous shrinkage. Autogenous shrinkage occurs as a result of internal moisture depletion due to hydration and temperature-induced effects. The level of autogenous shrinkage occurring due to hydration also depends on temperature history at very early age. It is necessary that effect of temperature on autogenous shrinkage is investigated since the stress generated due to autogenous shrinkage is quantified. In this study, Effect of hydration heat evolution on autogenous shrinkage of high strength concretes with W/C=25-40% was investigated.

  • PDF

Application of internet of things for structural assessment of concrete structures: Approach via experimental study

  • D. Jegatheeswaran;P. Ashokkumar
    • Smart Structures and Systems
    • /
    • v.31 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Assessment of the compressive strength of concrete plays a major role during formwork removal and in the prestressing process. In concrete, temperature changes occur due to hydration which is an influencing factor that decides the compressive strength of concrete. Many methods are available to find the compressive strength of concrete, but the maturity method has the advantage of prognosticating strength without destruction. The temperature-time factor is found using a LM35 temperature sensor through the IoT technique. An experimental investigation was carried out with 56 concrete cubes, where 35 cubes were for obtaining the compressive strength of concrete using a universal testing machine while 21 concrete cubes monitored concrete's temperature by embedding a temperature sensor in each grade of M25, M30, M35, and M40 concrete. The mathematical prediction model equation was developed based on the temperature-time factor during the early age compressive strength on the 1st, 2nd, 3rd and 7th days in the M25, M30, M35, and M40 grades of concrete with their temperature. The 14th, 21st and 28th day's compressive strength was predicted with the mathematical predicted equation and compared with conventional results which fall within a 2% difference. The compressive strength of concrete at any desired age (day) before reaching 28 days results in the discovery of the prediction coefficient. Comparative analysis of the results found by the predicted mathematical model show that, it was very close to the results of the conventional method.

Effects of the Placement Time on the Early-Age Crack Patterns of Concrete Pavements (콘크리트 포장의 포설시기가 시공초기의 균열 발생 패턴에 미치는 영향)

  • Suh, Young Chan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.135-139
    • /
    • 1993
  • It was found in a series of test sections constructed in Houston, Texas that (1) concrete placement in hot season resulted in much more early-age cracks than that in cool season, and that, (2) for the hot season placement, pavements placed in the morning showed more early-age cracks than those placed in the afternoon. Early-age cracks, in this study, are defined as cracks occurring within a few days after construction. Since the early-age cracks have a tendency to be meandering and the crack widths are relatively wide, they may give an adverse effect on the long-term performance of the pavement. The objectives of this study are to recognize the effects of placement time on the early-age crack patterns and to find the reason of the effects. The effects are explained in this study by relating hydration of cement and surrounding temperature conditions.

  • PDF

Development of Early-Strength of High-Strength Concrete According to Curing Temperature for Application of System Form (시스템 거푸집 적용을 위한 고강도 콘크리트의 양생온도별 조기강도 발현성상)

  • 김무한;이승훈;강석표;길배수;주지현
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.536-543
    • /
    • 2001
  • Nowadays, with high-stoned and large-sized of structures, high-strength concrete is applicable to various methods. When high-strength concrete is used jointly with system form, seizing on the development of compressive strength at early age is very important in aspect of construction process. Because system form is stripped more faster than ordinary form. But, we have little data of compressive strength before system-form is stripped, and it isn't yet established that decision criterion of the time when system-form is stripped. So this paper deals with the development of compressive strength at early age before system-form is stripped. In this study, the experimental results indicate the boundary of curing temperature and mixing factor that is able to get needful early-strength in the application of slip-form method, and curing temperature must be kept over 15 degrees in winter season.

Evaluation of Field Application on the Prediction Method of Early-age Strength of Early Concrete for Construction Work Period Reduction (공기단축 조강콘크리트의 조기강도 예측기술의 현장적용성 평가)

  • Lee, Woong-Jong;Keum, Kyoung-Hun;Lee, Jae-Hyun;Jung, Yang-Hee;Kim, Yong-Ro
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.443-444
    • /
    • 2010
  • In this study, It is confirmed the validity for determination of the form removal time, utilizing prediction expression for early-stage strength which depended on the variation of curing history for early strength concrete which be passible to construction work period reduction, in apartment.

  • PDF

Crack Control of Early-Age High Strength Concrete Deck in Composite Bridge (합성거더교 초기재령 고강도 콘크리트 바닥판의 균열 제어)

  • Bae, Sung-Geun;Kim, Se-Hun;Jeong, Sang-Kyoon;Cha, Soo-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.493-496
    • /
    • 2008
  • The risk of transverse cracking in concrete decks of composite bridges is affected by many factors related to the bridge design, materials, and construction. Among others, the thermal and shrinkage stresses are the most important factors that affect the transverse cracking in early-age concrete decks. The thermal stress at the concrete deck is mainly affected by both ambient temperature and solar radiation. The shrinkage stress at the general strength concrete deck is mainly affected by drying shrinkage and the high strength concrete deck is mainly affected by autogeneous shrinkage. Three-dimensional finite element models of composite bridges were made to investigate the stress due to thermal and shrinkage stress.

  • PDF

Evaluation of Mechanical Properties of Early-age Concrete Containing Electric Arc Furnace Oxidizing Slag (전기로 산화슬래그를 혼입한 초기재령 콘크리트의 역학적 특성 평가)

  • Kwon, Seung-Jun;Hwang, Sang-Hyeon;Lim, Hee-Seob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.2
    • /
    • pp.93-100
    • /
    • 2019
  • In this study, the mechanical properties of early-age concrete were evaluated by mixing the electric arc furnace oxidizing slag fine aggregate with 30% and 50% replacement ratio. Slump test, air content test and unit volume weight test were performed for fresh concrete, and compressive strength test and chloride penetration experiments were carried out in hardened concrete. The compressive strength increased up to 7 days of curing age with increasing replacement ratio of the electric furnace oxidizing slag, but the strength decreased to 90% level of OPC concrete at 28 days of age. Regarding the result of chloride penetration test, no significant differences from OPC concrete were evaluated, which shows a feasibility of application to concrete aggregate.

Evaluation on Early-Age Strength of Very-Early-Strength Dry-Mix Shotcrete (초속경 건식 숏크리트의 조기강도 평가)

  • Choi, Sung-Yong;Seo, Jae-Yeop;Jung, Beom-Seok;Yun, Kyong-Ku;Kim, Ki-Heon;Kim, Yong-Gon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.519-520
    • /
    • 2009
  • The purpose of this research was to develop a very-early-strength dry-mix shotcrete without accelerator using a rapid-setting cement, to analyze the correlationship of test results among cube test, core test, pullout test and maturity

  • PDF