• 제목/요약/키워드: early voltage

검색결과 169건 처리시간 0.023초

Jerk 함수를 적용한 태양광 스트링 내의 노후화 모듈 검출 기법 (Detection of Aging Modules in Solar String with Jerk Function)

  • 손한별;박성미;박성준
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.356-364
    • /
    • 2019
  • In this study, major problems, such as licensing problems due to civil complaints, deterioration of facility period, and damage of modules, are exposed to many problems in domestic businesses. Particularly, the photovoltaic (PV) modules applied to early PV systems have been repaired and replaced over the past two decades, and a new module-based aging detection method is needed to expand the maintenance market and stabilize and repair power supplies. PV modules in a PV system use a string that is configured in series to generate high voltage. However, even if only one module of the solar modules connected in series ages, the power generation efficiency of the aged string is reduced. Therefore, we propose a topology that can measure the instantaneous PV characteristic curve to determine the aging module in the solar string and the aging judgment algorithm using the measured PV characteristic curve.

보형물 삽입 유방의 압박 두께에 따른 유방 선량 평가 (Evaluation of Breast Dose by Breast Pressure Thickness of Breast Prosthesis Insertion)

  • 이현용;김지수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.469-473
    • /
    • 2020
  • Breast cancer is growing rapidly year by year and has the highest incidence since 2001. As a result, the interest in mammography for early detection of breast cancer is increasing. However, mammography is accompanied by radiation exposure and therefore it is necessary to reduce exposure dose through appropriate test conditions. The significance of this study is that breast dose studies, which were limited to ordinary women, were applied to breast implant patient. Using MCNP simulation, the phantom with prosthesis inserted was developed to compare dose by tube voltage by pressure thickness. In addition phantom without prostheses has higher dose than phantom with prostheses. If these results were used as basic data, it would be possible to recommend test condition guideline only for breast implant patients.

차세대 스마트 전자를 위한 전기화학 트랜지스터 (Electrolyte-gated Transistors for the Next-generation Smart Electronics)

  • 권혁진;김세현
    • 공업화학전망
    • /
    • 제23권2호
    • /
    • pp.1-11
    • /
    • 2020
  • In this report, we summarize recent progress in the development of electrolyte-gated transistors (EGTs) for various printed electronics. EGTs, employing a high capacitance electrolyte as gate dielectric layer in transistors, exhibits increasing of drive current, lowering operation voltage, and new transistor architectures. While the use of electrolytes in electronics goes back to the early days of silicon transistors, the new printable, fast-responsive polymer electrolytes are expanding their range of applications from printable and flexible digital circuits to various neuromorphic devices. This report introduces the structure and operating mechanism of EGT and reviews key developments in electrolyte materials used in printed electronics. Additionally, we will look at various applications with EGTs that are currently underway.

NaF 전해용액을 이용한 양극산화에 의한 타이타늄 표면의 나노튜브구조의 형성에 관한 연구 (Investigation on Formation of Nanotube Titanium Oxide Film by Anodizing on Titanium in NaF Electrolytes)

  • 임현필;박남순;박상원
    • 구강회복응용과학지
    • /
    • 제25권2호
    • /
    • pp.183-190
    • /
    • 2009
  • 본 연구의 목적은 NaF와 $H_3PO_4$를 사용하여 양극산화과정을 통해 나노튜브 제작 조건을 찾는 것이다. 절삭된 직경 15 mm, 두께 1.5 mm의 티타늄 디스크를 양극에, 백금을 음극에 연결하고 전극간의 거리는 10 mm가 되도록 하였다. $H_3PO_4$와 NaF 용액을 전해질로 하여 양극산화를 시행하였는데 전압, 전해질 농도, 산화시간을 달리하여 티타늄 디스크에 나노튜브를 형성하였다. 양극산화 후 24시간 동안 증류수로 세척한 후 24시간 동안 $40^{\circ}C$ 오븐에서 건조하고 시편의 표면구조 형상을 관찰 분석하였다. 실험 결과 0.5 wt % NaF에서 전압과 시간이 증가함에 따라 pore 형태의 초기 나노튜브 형성되었다. 1.0 wt % NaF에서 20 V, 20 분과 25 분에서 나노튜브가 생성되었고, 30 V에서 튜브의 형태가 커지면서 터지는 양상을 보였다. 2.0 wt % NaF에서 전압과 시간에 상관없이 적절한 나노튜브형태가 형성되지 않았다. $1M\;H_3PO_4$, 1.0 wt % NaF 전해용액, 20 V, 20분 양극산화 조건에서 티타늄 디스크 상에 가장 잘 정렬된 형태의 나노튜브 구조가 형성되었다. 양호한 형태의 나노튜브 형성을 위해서는 전해질의 종류에 따라 적절한 농도, 전압, 시간의 형성조건이 필요할 것으로 사료된다.

평판형 나트륨 유황 전지의 초기 충방전시 방전전압 변화 (Changes of discharge voltage of plate-type sodium sulfur batteries in the early charge/discharge cycles)

  • 김성인;김헌태;최희락;임산수대;양기덕;범진형;김창삼
    • 한국결정성장학회지
    • /
    • 제24권4호
    • /
    • pp.164-168
    • /
    • 2014
  • 나트륨 유황 전지는 $350^{\circ}C$ 이상의 고온에서 작동하는 대용량 전지로 에너지 저장 시스템에 주로 사용된다. 전지는 음극 액체 나트륨과 양극 액체 유황 그리고 고체 전해질 베타 알루미나(${\beta}^{{\prime}{\prime}}$-alumina)로 구성되어 있다. 이 전지는 초기충방전 사이클에서 상당한 전압변화를 보이기 때문에 전지의 안정화를 위해 컨디셔닝 과정이 필요하다. 실험 결과 전지 전압 변화의 주요한 원인 중의 하나가 액체 나트륨과 고체 전해질과의 접촉 면적이 변하기 때문인 것을 알았다.

75kW 용융탄산염 연로전지[MCFC] 스택 운전 결과 (The Operating Results of the 75kW MCFC Stack)

  • 강승원;김범주;김도형;이정현;김의환;임희천
    • 한국수소및신에너지학회논문집
    • /
    • 제20권3호
    • /
    • pp.202-207
    • /
    • 2009
  • A 75kW MCFC stack with the reactive area of 9,600cm$^2$ has been operated and validated in Boryeong thermal power plant. The 75kW MCFC stack was installed at the end of November 28, 2008 and started initial operation on December 23, 2008 after pretreated for about 20 days. At initial load operation, the stack showed the Open Circuit Voltage of 137V, which approaches the theoretical value. At the early stage of rated power operation, the stack displayed the voltage of 104V at the current of 754A and reached the maximum generating power of 78.5kW DC. This stack has been operated for 2,890 hours until April, 2009. In addition, the operation time of rated power records 1890 hours. This Operating result is scheduled to be reflected the design of l25kW stack.

연면방전에 의한 폴리머애자의 자외선 발생과 열화특성 (The Characteristics of UV Generation and Aging Materials in According to Surface Discharge)

  • 송길목;방선배;김종민;김영석;정진수
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1606-1611
    • /
    • 2008
  • Recently, The diagnosis techniques of electric facilities are developed on live line. This paper describes the discharge characteristics of polymer insulator(EPDM A type). Keeping the facilities in good working order, the goal of this paper will provide the information to enable user to easily judge conditions of facilities on the spot. The performance of polymer insulator is assessed from the KS C IEC 60270 and CEA LWIWG-01(96)(Tracking Wheel Test). As the results, UV generation patterns of polymer insulator grow like a jellyfish shape follow the ramping voltage. Discharging UVs are detected at about 31.25% of breakdown voltage. Just then, dimension of UV image is about $0.84cm^{2}$. The dimension of max. UV image is about $297.4cm^{2}$ at $160kV(V_{bd})$. The position of UV generation due to surface discharge of polymer insulator is the center of insulator in the early, then moved the ground side and the last, UV image moved through the junction part of source side. Surface of aged polymer insulator is cracked and faded due to arc. UV absorption spectrum of polymer insulator are appeared the C-H bond of scissoring vib. at $1014cm^{-1}$ and C=O bond of recombination structure. Also, recombined UV absorption peak such as C-H, N-H, and O-H is detected at the $3321cm^{-1}$. Through the paper, there are inspection data which are the relations between surface discharge of polymer insulator and UV detecting image.

48개 채널의 GM Tube 센서 테스터 장치의 설계 (Design of Tester Apparatus for 48 Channel GM Tube Sensor)

  • 이희열;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.310-313
    • /
    • 2016
  • 본 논문에서는 48개 채널의 GM Tube 센서 테스터 장치를 설계한다. 제안하는 장치는 48 채널의 GM Tube 센서들을 동시에 테스트하여 불량의 여부 및 센서 특성을 분석한다. 시간의 변화에 따라 달라지는 센서의 특성에 적합한 300 ~ 1000V의 가변 고전압을 발생할 수 있는 회로로 센서의 특성을 분석한다. 따라서 다양한 종류의 GM Tube 센서의 특성 분석에 용이하게 사용된다. 제안하는 장치를 통해 대량의 GM Tube를 동시에 테스트 할 수 있는 환경이 구축되어 센서의 불량 여부 및 센서의 특성을 미리 파악하여 생산 및 재작업 등에 소요되는 비용을 대폭 줄일 수 있다. 개발된 48 채널 GM Tube 센서 테스터 장치의 측정 불확도에 대하여 공인 시험기관의 장비를 사용하여 실험한 결과 우수한 성능을 나타내었다.

Effect of Genistein, a Tyrosine Kinase Inhibitor, on the Cloned Rat Brain Potassium Channel Kv1.5

  • Choi, Bok-Hee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제10권5호
    • /
    • pp.243-249
    • /
    • 2006
  • The effect of genistein, widely used as a specific tyrosine kinase inhibitor, on rat brain Kv1.5 channels which were stably expressed in Chinese hamster ovary cells was investigated using the whole-cell patch-clamp technique. Genistein inhibited Kv1.5 currents at +50 mV in a concentration-dependent manner, with an $IC_{50}$ of $54.7{\pm}8.2\;{\mu}M$ and a Hill coefficient of $1.1{\pm}0.2$. Pretreatment of Kv1.5 with protein tyrosine kinase inhibitors ($10\;{\mu}M$ lavendustin A and $100\;{\mu}M$ AG1296) and a tyrosine phosphatase inhibitor ($500\;{\mu}M$ sodium orthovanadate) did not block the inhibitory effect of genistein. The inhibition of Kv1.5 by genistein showed voltage-independence over the full activation voltage range positive to 0 mV. The activation (at +50 mV) kinetics was significantly delayed by genistein: time constant for an activation of $1.4{\pm}0.2$ msec under control conditions and $10.0{\pm}1.5$ msec in the presence of $60\;{\mu}M$ genistein. Genistein also slowed the deactivation of the tail currents, resulting in a crossover phenomenon: a time constant of $11.4{\pm}1.3$ msec and $40.0{\pm}4.2$ msec under control conditions and in the presence of $60\;{\mu}M$ genistein, respectively. Inhibition was reversed by the application of repetitive depolarizing pulses, especially during the early part of the activating pulse. These results suggest that genistein directly inhibits Kv1.5 channels, independent of phosphotyrosine-signaling pathway.

반복계산법을 이용한 철도고압배전계통의 고장점표정 알고리즘 (Fault Location Estimation Algorithm in the Railway High Voltage Distribution Lines Using Flow Technique)

  • 박계인;창상훈;최창규
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.71-79
    • /
    • 2008
  • 철도 고압배전선로의 경우 궤도를 따라 양방향으로 선로연변에 통신 및 신호설비와 병행하여 가공 또는 지중선로로 설치되어 있다. 가공선로의 경우에는 대기중에 노출되어 있어 뇌격, 폭풍우, 염해 등 자연현상으로 인한 고장발생이 다수 발생하고 있으며, 이에 따른 보호장치의 오 부동작이 빈번하게 발생하고 있다. 철도 고압배전선로에서 발생하는 사고 중 가장 많은 것은 1선 지락이지만 이밖에 선간 단락, 심할 경우에는 3선 지락(단락)으로까지 진전되는 사고가 있을 뿐만 아니라 단선 사고까지 발생하는 경우도 있다. 따라서 사고를 방지하기 위해서는 보다 상세한 점검보수가 필요하며, 고장발생시 조기발견과 신속한 고장처리는 철도안전수송에 중요하다. 본 논문에서는 철도 고압배전계통의 주류를 이루게 될 22.9[kV] 직접접지 계통을 대상으로 고장 발생시 고장 위치를 신속하게 표정할 수 있는 고장점 표정 알고리즘 개발을 위해 22.9[kV] 고압배전계통을 모델링 하여 특성해석과 고장해석을 수행하였고, 정확한 고장점 표정이 가능한 반복계산법을 이용한 알고리즘을 제시하였으며, 사례연구를 통해 성능을 입증하였다.