• 제목/요약/키워드: ear canal volume

검색결과 7건 처리시간 0.024초

외이도용적에 따른 외이도공명의 변화 (Resonance Changes in the External Auditory Canal Associated with the Ear Canal Volume)

  • 최아현;이미소;최아름;허승덕
    • 말소리와 음성과학
    • /
    • 제1권3호
    • /
    • pp.151-154
    • /
    • 2009
  • The external ear generates resonance gain because of anatomical characteristics. The ear canal resonance is influenced by the length and volume of the ear canal, the pinna, the concha cavity, the body trunk, and the speed of sound wave. This study is focus on the influence of the volume of ear canal. 17-healthy-adult (32 ears) were participated. They did not have any medical and ear disease history. The maximum resonance frequency of the ear canal was 2675 (${\pm}265$) Hz at azimuth $0^{\circ}$ and 2784 (${\pm}268$) Hz at azimuth $45^{\circ}$. The resonance gain was 18.1 (${\pm}3.9$) dB at azimuth $0^{\circ}$ and 17.9 (${\pm}3.8$) dB at azimuth $45^{\circ}$, respectively. The ear canal volume was 0.78 (${\pm}0.2$) cc and 1.32 (${\pm}0.8$) cc including static compliance. The ear canal resonance was changed depending on the ear canal volume. It was also statistically correlated at azimuth $0^{\circ}$ (p=0.038) and $45^{\circ}$ (p=0.013), respectively. The resonance gain was not correlated with the ear canal volume. The change of resonance frequency according to the ear canal volume will be useful information in the field of audiological rehabilitation especially for hearing aids fitting. In addition, we expected this study can provide the basic information for the study of the external ear resonance characteristics.

  • PDF

DICOM 영상과 설계 모델링을 융합한 외이도의 형태적 변화 관찰 연구 (An Observational Study on the Morphological Changes of the External Ear Canal by Converging DICOM Imaging and Design Modeling)

  • 김형균
    • 한국융합학회논문지
    • /
    • 제10권11호
    • /
    • pp.173-179
    • /
    • 2019
  • DICOM 영상은 인체의 진단과 치료에 중요한 역할을 하고 있으며 설계모델링은 목적에 따라 형상을 3차원으로 계획하는 기술이다. 본 연구는 이러한 두 가지 기술을 융합하여 외이도의 형태적 변화에 대한 횡단면, 부피, 표면적의 관계를 관찰하고자 하였다. 실험은 인체의 단면 획득 의료영상기술을 적용하여 19귀의 외이도를 추출한 3차원 형상을 스테레오리소그래피, 3-매틱(matic) 프로그램으로 센터라인 생성 및 분할 기술을 적용하였다. 그 결과 외이도의 횡단면 구조는 타원형(38.5%), 반원형(28.2%), 혼재형(17.9%), 네모형(10.2%), 주름형(5.1%)등 다양한 형태가 나타났다. 또한 외이도 길이가 길수록 위상별 횡단면 면적은 크게 나타났으며 부피와 표면적은 고막방향으로 갈수록 감소하였지만 그 감소율은 상대적으로 낮게 나타났다. 이는 외이도의 형태가 고막방향으로 갈수록 불규칙한 구조로 되어 있음을 나타냈다.

DICOM 영상을 이용한 외이도 음향해석 방법에 관한 연구 (A Study on the Acoustic Analysis Method of the External Ear Canal Using DICOM Images)

  • 김형균
    • 한국융합학회논문지
    • /
    • 제10권3호
    • /
    • pp.73-79
    • /
    • 2019
  • 머리 측두부 디지털 영상 및 통신 표준 영상을 이용한 외이도 길이, 상하 굴곡각도, 내 외경 비율에 따른 음향민감도를 외이도 모델링으로 시뮬레이션하고 측정하였다. 실험은 인간 가청주파수 기준으로 200Hz씩 증가하면서 1 파스칼의 압력으로 일정하게 전달된 주파수를 고막 음향크기로 나타내어 그 측정값들을 선형과 이차곡선 회귀분석으로 나타내었다. 그 결과 외이도 길이는 길수록, 외 내경 둘레의 비율은 높을수록 낮은 주파수에서 빠른 음향적 반응을 나타내었다. 회귀분석을 이용한 메타모델의 음향민감도 상관관계는 외이도 길이가 77%, 외 내경 비율 5%의 영향으로 나타났지만 상하 굴곡각도는 특별한 관계를 나타내지 못하였다. 이로써 인간의 청각음향 민감도는 외이도 길이가 길수록, 외 내경 둘레의 비율 차이가 높을수록 낮은 주파수에서 빠르게 반응하는 인자임을 알 수 있었다.

CIC형 보청기용 범용 이어쉘 제작을 위한 파라미터 추출 및 시뮬레이션 (Parameter Extraction and Simulation in order to Manufacture Ready-made Ear Shell for CIC Type Hearing Aids)

  • 에르덴바야르;전유용;박규석;송영록;이상민
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권4호
    • /
    • pp.321-327
    • /
    • 2010
  • Most of the ear shells of hearing aids are manufactured manually, and it is one of the reasons that the cost of the custom-made hearing aids can be increased. Thus it is required to manufacture the ready-made ear shell for the purpose of easy manufacturing and decrease in cost. In this study, we extract parameters in order to manufacture the ready-made ear shell for CIC type hearing aids and simulate to reconstruct the ear shell using the extracted parameters. To parameter extraction, we set up the eleven parameters for the ready-made ear shell based on anatomical characteristics of the ear canal, and we found values of the parameters from twenty-one impressions in their 20s and twelve impressions in their 60s using aperture detection and feature detection algorithms. Classifying the parameters by size, we also determine the parameters of ready-made ear shell into three types for people in their 20s and two types for people in their 60s. Each ready-made ear shell was simulated to reconstruct using figured parameters, and evaluated the rate of agreement with unused impressions for setting parameters. To evaluate the ready-made ear shell, we calculate the volume ratio and intersection between of the each impression and ready-made ear shell, and the intersection ratio using the intersection volume and ready-made ear shell volume. As a result, the volume ratio was about 70%, and volume match ratio was also up to 70%. It means that the ready-made ear shell we simulated is the significantly matched to impression.

보청기용 범용 이어쉘을 위한 설계 파라미터에 관한 연구 (A Study on Design Parameters for Ready-made Ear Shell of Hearing Aids)

  • 에르덴바야르;전유용;박규석;송영록;이상민
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1055-1061
    • /
    • 2011
  • In this study, main parameters: aperture, first bend and second bend which express a structure of ear canal are extracted in order to modeling and manufacture the ready-made ear shells of hearing aids. The proposed parameter extraction method consists of 2 important algorithms, aperture detection and feature detection. In the aperture detection algorithm, aperture of 3-D scanned virtual ear impression and parameters relating to ear shell of hearing aid are determined. The feature detection algorithm detects first bend, second bend, and related parameters. Through these two algorithms, parameters for aperture, first bend, and second bend are extracted to model the ready-made ear shell of hearing aid. The values of these extracted parameters from 36 people's right ear impression are analyzed and measured statistically. As a result of the analysis, it has been found that it is possible to classify ready-made ear shell parameters by age and size. The ready-made ear shell parameters are classified 3-size for 20 years old and 2-size for 60 years olde. Using 3D rhino program, virtual ready-made ear shell is reconstructed by parameters of every type, and simulated to model it. A final product was produced by transferring simulation result with rapid prototyping system. The modeled ready-made ear shell is evaluated with the objective and subjective method. Objective method is the comparison volume ratio and overlapped volume ratio of ear impression from randomly chosen 18 people and ready-made ear shell. And subjective method is that the final product of ready-made ear shell is used by users and the satisfaction number drawn from well fitting and comfortable testing was evaluated. In the result of the evaluation, it has been found that volume ration is 70%, big and middle size ready-made ear shell products are possible, and the satisfaction number is high.

측두골의 함기도와 중이강의 용적이 고막 임피던스에 미치는 영향에 관한 연구 (Experimental and clinical studies with impedance audiometry; the increase in air volume in the middle ear air system and the pneumatization of human temporal bones)

  • 민양기
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1977년도 제11차 학술대회연제 순서 및 초록
    • /
    • pp.4.4-5
    • /
    • 1977
  • 중이의 impedance는 고막, 이소골연쇄 및 중이강.유양동.함기봉와의 공기강에 의해 결정되는 바, 저자는 우선 신선한 개의 중이를 재료로 하여 중이강의 강기체적을 변동시킴으로써 중이강의 공기체적인자가 중이의 impedance를 어떻게 변동시키는가를 조사하였고, 다음으로 과거력과 현재상태에서 외이도, 고막 및 중이에 병변이 없는 환자에서 중이의 impedance를 측정하고 아울러 측두골의 X-녹상을 언어 측두골의 함기도에 따라 중이의 static compliance의 변동을 조사하여 이과학의 임상적인 면에서의 중이의 static compliance의 또 하나의 이용가치를 구명하여 다음과 같은 결론을 얻었다. 1. 개의 중이는 control state에서 Type A의 tympanogram을 보였으며, 중이강의 공기체적의 변동에 의해 tympanogram curve의 채형은 변동하지 않았다. 2. 개의 중이에 있어서 중이의 static complance는 중이강의 공기체적의 변동에 의해 유의한 직선적인 증가를 보였으며, 중이강의 공기체적 1cc의 증가에 대해 $0.5{\pm}0.1$cc의 증가율을 보였다. 3. 측두골의 함기도가 양호해짐에 따른 중이의 static compliance의 증가경향과 개의 측두골표본에서의 실험적인 근거로부터 측두골의 함기도(x)와 중이의 static compliance (y)사이에 $y=0.19x+0.16{\pm}0.05$의 회귀방정식을 얻을 수 있었다. 따라서 중이강의 공기체적의 변동은 유의한 중이의 static compliance의 변동을 일으키며, electroacoustic impedance bridge (Madsen ZO 70, 220 Hz 의 probe tone을 사용)를 사용하였 중이의 static compliance를 측정함으로써 임상적으로 측두골의 X-선상을 촬영하지 아니하고도 간단히 측두골의 함기도를 알 수 있을 것으로 생각되어, impedance audiometry의 임상진단학적인 견지에서의 또 하나의 가치를 보고하는 바이다.

  • PDF