• 제목/요약/키워드: e-coating simulation

검색결과 18건 처리시간 0.032초

BIW 전착도장에서의 컴퓨터 시뮬레이션 적용사례 (Introduction of Computer Simulation for BIW Electrocoating Process)

  • 손대홍;정희진;안승호;김병수;김정연;최병삼
    • Corrosion Science and Technology
    • /
    • 제15권2호
    • /
    • pp.78-83
    • /
    • 2016
  • The e-coating to inhibit induced corrosion can deposit a coating not only on the exterior surface but also on the inside of whole metallic components of body-in-white (BIW). But it is difficult to deposit paint films on the inside area because metallic components are multi layered. It may cause shortness of e-coating thickness. The only way to properly verify e-coating thickness is by performing the use of tear-down prototypes. When paint films' thickness is inadequate, a structural modification on each metallic component is needed. Verification of the thickness improvement for a structural modification requires much manual effort and leads to increasing development time. Recently, the simulation technology has been developed to predict the e-coating thickness in e-coating field. By applying the simulation to BIW, improvement in paint thickness quality and shortening of development period are expected. The paper explains a validated solution that allows simulating the effect of design changes to the e-coating thickness and current density, thereby delivering results within a time frame of a few days.

더블로이유리 적용 창호의 구성요소에 따른 단열성능 비교 실험 (A Comparison of Thermal Performance of Double Low-E Glazing Window according to Various Material)

  • 장철용;안병립;김치훈;김준섭;이성재
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.133-137
    • /
    • 2011
  • Low-e glazing is classified as soft low-e glazing and hard low-e glazing. Hard low-e glazing can be temperable and its handling is comfortable because its coating film is a oxide film generated at high temperatures. But there is a fatal weakness that its insulation performance and shielding performance are lower compared to soft low-e glazing by low electrical conductivity of coating film. Soft low-e glazing is excellent because its coating film consists of Ag that is excellent electrical conductivity and it has strength that can supply various product consumers want. But soft low-e glazing has weaknesses that temperable and handling are difficult because Ag is oxidized easily. Therefore this study analyzes thermal performance of glazing by changing filling gas according to applying low-e glazing through simulation to judge performance before making sample. After this process, a comparative experimental study was done through TVS by making temperable low-e glazing.

  • PDF

고출력 laser diode를 위한 AR, HR coating simulation에 관한 연구 (A study on AR, HR coating simulations for the high power laser diode)

  • 류정선;윤영섭
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권5호
    • /
    • pp.498-505
    • /
    • 1996
  • In the present work, we have developed the simulator to optimize the process conditions of the AR(antireflection) and HR(high-reflection) coatings for the high power laser diode. The simulator can run on the PC. After making the simple optical model, we establish the Maxwell equations for the model by the operator conversion. By using the Mathematica, we derive a matrix for the multilayer system by applying the equations to the model and optimize the AR and HR coating process conditions by obtaining the reflection rate from the matrix. We also prove the validity of the simulator by comparing the simulation with the characteristics of the laser diode which is AR and HR coated according to the optimized conditions.

  • PDF

스프레이 코팅 룸의 온도분포 해석 (Analysis of Temperature Distributions in Spray Coating Room)

  • 김남웅;김성용;김국원
    • 한국산학기술학회논문지
    • /
    • 제16권11호
    • /
    • pp.7667-7671
    • /
    • 2015
  • 아연말 코팅은 친환경성 및 고성능으로 인하여 널리 사용되고 있다. 일반적으로 코팅온도가 코팅층 두께 및 코팅품질을 결정하는 주요한 요소이므로 아연말 코팅의 경우에도 최적의 코팅온도가 요구되고 있다. 본 연구에서는 아연말 스프레이 코팅 룸의 온도분포를 해석하기 위해 룸 내부의 공기유동을 포함하는 열 유동 전산 시뮬레이션을 수행하였다. 3차원 CAD 프로그램인 SolidWorks를 이용하여 스프레이 코팅 룸 전체와 예열실과 건조실을 모두 고려한 모델링을 수행하였으며 Flow Simulation 프로그램을 이용하여 열 유동 해석을 수행하였다. 해석된 결과는 열화상카메라를 이용한 실험으로 검증하였다. 해석결과 제1스프레이실과 제2스프레이실의 온도분포 특성을 파악할 수 있었으며, 현재의 상태로는 목표 온도 값인 $25^{\circ}C$에 미달하고 있었음을 알 수 있었다. 단순히 히터를 추가하는 방법 대신, 현재 조건에서 스프레이실의 온도를 높이는 방안으로 배기팬을 사용하지 않는 경우에 대해 시뮬레이션을 수행하였으며, 그 결과 제1스프레이실의 온도가 $6.2^{\circ}C$, 제2스프레이실의 온도가 $5.8^{\circ}C$ 상승하였다. 본 연구 내용은 향후 스프레이 코팅 룸의 성능향상을 위한 설계에 이용될 수 있다.

Influences of Cathodic Protection and Coating Properties on the Corrosion Control of Metallic Structure in Extremely Acidic Fluids

  • Chang, H.Y.;Yoo, Y.R.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권6호
    • /
    • pp.242-249
    • /
    • 2005
  • A lot of parts in FGD (Flue Gas Desulfurization) systems of fossil-fuel power plants show the environments in which are highly changeable and extremely acidic corrosive medium according to time and locations, e.g. in duct works, coolers and re-heaters etc. These conditions are formed when system materials are immersed in fluid that flows on them or when exhausted gas is condensed into thin layered acidic medium to contact materials of the system walls and roofs. These environments make troublesome corrosion and air pollution problems that are occurred from the leakage of the condensed solution. To cathodically protect the metallic structures in extremely acidic fluid, the properties of the protective coatings on the metal surface were very important, and epoxy Novolac coating was applied in this work. On the base of acid immersion tests, hot sulfuric acid decreased the hardness of the coatings and reduced greatly the content of $Na_2O$, $Al_2O_3$, and $SiO_2$ among the main components of the coating. A special kind of CP(Cathodic Protection) system has been developed and tested in a real scale of the FGD facility. Applied coating for this CP system was peeled off and cracked in some parts of the facility. However, the exposed metal surface to extremely acidic fluid by the failure of the coatings was successfully protected by the new CP system.

AN EVALUATION OF ENERGY PERFORMANCE IN SUPER HIGH-RISE APARTMENT HOUSING WITH EXTERIOR WINDOW TYPES

  • Sang-Ho Lee;Yong-Ho Park;Jong-Chan Lee
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1637-1642
    • /
    • 2009
  • This study evaluates the energy performance of super high-rise residential buildings with e-QUEST simulation and calculates the annual cooling and heating load. The result of this study have concluded that the most influential factor is the characteristics of the window and also suggest the most efficient window system from the result of calculation of different glasses' cooling and heating load. The result of this study shows that The most efficient method to enhance the energy performance is to use low reflective 3 pairs Low-E glass and Low-E coating(inside of outer glass) pair glass.

  • PDF

Temperature Dependent Behavior of Thermal and Electrical Contacts during Resistance Spot Welding

  • Kim, E.
    • International Journal of Korean Welding Society
    • /
    • 제2권1호
    • /
    • pp.1-10
    • /
    • 2002
  • The thermal contact conductance at different temperatures and with different electrode forces and zinc coating morphology was measured by monitoring the infrared emissions from the one dimensionally simulated contact heat transfer experiments. The contact heat transfer coefficients were presented as a function of the harmonic mean temperature of the two contacting surfaces. Using these contact heat transfer coefficients and experimentally measured temperature profiles, the electrical contact resistivities both for the faying interface and electrode-workpiece interface were deduced from the numerical analyses of the one dimension simulation welding. It was found that the average value of the contact heat transfer coefficients for the material with zinc coating (coating weight from 0 g/$mm^2$to 100 g/$mm^2$) ranges from 0.05 W/$mm^2$$^{\circ}C$ to 2.0 W/$mm^2$$^{\circ}C$ in the temperature range above 5$0^{\circ}C$ harmonic mean temperature of the two contacting surfaces. The electrical contact resistivity deduced from the one dimension simulation welding and numerical analyses showed that the ratio of electrical contact resistivity at the laying interface to the electrical contact resistivity at the electrode interface is smaller than one far both bare steel and zinc coated steel.

  • PDF

고균일 유기박막 코팅을 위한 모세관 현상 전산모사 (Simulation of Capillary Phenomenon for Solution Coating of High-uniformity Organic thin Films)

  • 신동균;홍기영;박종운;서화일
    • 반도체디스플레이기술학회지
    • /
    • 제16권1호
    • /
    • pp.106-111
    • /
    • 2017
  • When a substrate with a pixel-defining layer (bank) is coated, there arises capillary force due to surface tension and adhesive forces between a solvent and the bank layer. It brings in a degradation of film thickness and emission uniformities within pixels. With an attempt to suppress it, we have performed fluid flow simulations of capillary arise by varying the contact angle of bank and the bank structure. We have first demonstrated that the fluid flow model can reproduce the capillary phenomenon that was observed experimentally. It has been found that capillary arise can be suppressed using a hydrophobic material for the bank layer. Furthermore, it was suppressed by tilting the sidewalls outwardly (i.e., using a positive photoresistor). We can obtain very uniform films when the slope is $50^{\circ}$ with the contact angle of $40^{\circ}$.

  • PDF

동기지 동계 Bulk Amorphous 복합재의 압축 변형거동 (Deformation behavior in Cu-based bulk amorphous alloys composite during compression)

  • 이창호;김지수;박은수;허무영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 추계학술대회논문집
    • /
    • pp.203-206
    • /
    • 2004
  • Copper-based bulk amorphous alloy composite was synthesized by using the copper-coated $Cu_{54}Ni_{6}Zr_{22}Ti_{18}$ amorphous powder which was obtained by argon gas atomization. The amorphous powder having a super-cooled liquid region of 53 K was coated by crystalline copper by electroless coating. The consolidation was carried out by manufacturing performs and by the subsequent warm extrusion at 743 K. During the compression test at the room temperature, the composite containing a large fraction of crystalline copper displayed a larger plastic strain after yielding. FEM simulation revealed change in fracture modes in the composites depending on the amount of crystalline copper in the composites.

  • PDF