• 제목/요약/키워드: e-coating

Search Result 594, Processing Time 0.029 seconds

Introduction of Computer Simulation for BIW Electrocoating Process (BIW 전착도장에서의 컴퓨터 시뮬레이션 적용사례)

  • Sohn, DaeHong;Jung, HiZean;Ahn, SeungHo;Kim, ByungSu;Kim, JungYeon;Choi, ByungSam
    • Corrosion Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.78-83
    • /
    • 2016
  • The e-coating to inhibit induced corrosion can deposit a coating not only on the exterior surface but also on the inside of whole metallic components of body-in-white (BIW). But it is difficult to deposit paint films on the inside area because metallic components are multi layered. It may cause shortness of e-coating thickness. The only way to properly verify e-coating thickness is by performing the use of tear-down prototypes. When paint films' thickness is inadequate, a structural modification on each metallic component is needed. Verification of the thickness improvement for a structural modification requires much manual effort and leads to increasing development time. Recently, the simulation technology has been developed to predict the e-coating thickness in e-coating field. By applying the simulation to BIW, improvement in paint thickness quality and shortening of development period are expected. The paper explains a validated solution that allows simulating the effect of design changes to the e-coating thickness and current density, thereby delivering results within a time frame of a few days.

Corrosion protection behavior of AZ31 magnesium alloy with cathodic electrophoretic coating pretreated by cerium based conversion coatings at various pH

  • Fazal, Basit Raza;Phuong, Nguyen Van;Moon, Sungmo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.268-268
    • /
    • 2015
  • The corrosion protection behavior of AZ31 magnesium alloy (Mg alloy) with cathodic electrophoretic coating (E-coating) pretreated by cerium-based conversion coatings at various pH was investigated in this study. Cerium-based conversion coatings (CeCCs) were deposited on AZ31 Mg alloy by immersion treatment in the nitrate-based cerium salt solution. The morphology and composition of the CeCCs were analyzed using scanning electron microscopy and energy dispersive X-ray spectroscopy. The corrosion properties of the AZ31 Mg alloy pretreated with cerium coating and subsequently E-coated were studied during salt-spray testing. The surface morphologies of the E-coated Mg alloy were examined in detail after different testing times using digital photography. It was found that the protective properties of the E-coating on AZ31 Mg alloy generated are heavily dependent upon the CeCC factors such as treatment time, coating thickness and pH of the solution.

  • PDF

Studies on Enteric Coating Bases. I Selection of Enteric Coating Bases by Invitro Test (9 장용피기제에 관한 연구(제1보) Invitro Test에 의한 기제의 선택에 대하여)

  • 김수억;지달현;문정현;이금정
    • YAKHAK HOEJI
    • /
    • v.5 no.1
    • /
    • pp.31-36
    • /
    • 1960
  • The importance of enteric coating technique among the pharmaceutical firms has recently risen very significantly. This study of enteric coating bases was made in order to determine the most suitable bases and dusting powders. Materials and equipment used in this experiment are shown in table 1 and kinds of enteric coating bases and their formulas are shown in table 2. The evaluation of the suitability for enteric coating bases and dusting powder was made by disintergration test after measuring the thickness of the enteric coated layer as shown in the tables 4 and 5. Based on the results of this study, the base D(shellac 20 Gm, anhydrous lanoline 5 Gm, 96% alcohol 75 ml) and the base E (shellac 10 Gm, cetyl alcohol 10 Gm. acetone 80 ml) are selected among the 8 kinds of bases studied in a preliminary test and it was found that Mg-stearate and CA-stearate were in most suitable dusting powders among the 6 kinds studied for the bases D and E. Further study on base D and E was carried out by varying the proportions of the materials which were the original constituents of bases D and E. According to the result of this further study shown in table 6, the shellac 15 Gm cetyl alcohol 5 Gm Acetone 80 ml of base E is recommended as the most suitable dusting powder.

  • PDF

Formation of Cerium Conversion Coatings on AZ31 Magnesium Alloy

  • Fazal, Basit Raza;Moon, Sungmo
    • Journal of Surface Science and Engineering
    • /
    • v.49 no.1
    • /
    • pp.1-13
    • /
    • 2016
  • This review deals with one of the surface modification techniques, chemical conversion coating and particularly cerium-based conversion coatings (CeCC) as a promising substitute for chromium and phosphate conversion coating on magnesium and its alloys. The CeCCs are commonly considered environmentally friendly. The effects of surface preparation, coating thickness, bath composition, and e-paint on the corrosion behavior of CeCCs have been studied on the AZ31 magnesium alloy. This review also correlates the coating microstructural, morphological, and chemical characteristics with the processing parameters and corrosion protection. Results showed that the as-deposited coating system consists of a three layer structure (1) a nanocrystalline MgO transition layer in contact with the Mg substrate, (2) a nanocrystalline CeCC layer, and (3) an outer amorphous CeCC layer. The nanocrystalline CeCC layer thickness is a function of immersion time and cerium salt used. The overall corrosion protection was crucially dependent on the presence of coating defects. The corrosion resistance of AZ31 magnesium alloy was better for thinner CeCCs, which can be explained by the presence of fewer and smaller cracks. On the other hand, maximum corrosion protection was achieved when AZ31 magnesium samples with thin CeCCs are e-painted. The e-paint layer further restricts and hinders the movement of chloride and other aggressive ions present in the environment from reaching the magnesium surface.

Effect of Fluoride Conversion Coating on the Corrosion Resistance and Adhesion of E-painted AZ31 Magnesium Alloy

  • Fazal, Basit Raza;Moon, Sungmo
    • Journal of Surface Science and Engineering
    • /
    • v.49 no.5
    • /
    • pp.395-400
    • /
    • 2016
  • This article reports improved corrosion resistance and adhesion of electro-paint (E-paint) with fluoride conversion coating (FCC) on AZ31 Mg alloy for the first time. These improvements were observed in comparison to chemically polished samples with no chemical conversion coating and samples with cerium conversion coatings (CeCC). FCCs were prepared in a hydrofluoric acid (HF) solution for four different times; 10, 30, 60, and 120 s. The colour of the samples changed from light gold to brown with increasing immersion time, indicating the formation of thicker FCC coatings with increasing immersion time. The adhesion of the E-paint on FCC-coated AZ31 Mg alloy was tested after 500 h of immersion in deionized (DI) water. Salt spray test (SST) results revealed delamination of E-paint on the chemically polished sample, severe blistering on the samples with CeCC, but no delamination and no blistering on the samples with FCC.

The Transient Response Characteristics of Compliant Coating to Pressure Fluctuations

  • Lee In-Won;Chun Ho-Hwan;Kim Jin
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.533-544
    • /
    • 2006
  • The amplitude and phase lag of surface deformation were determined for a compliant coating under the action of turbulent pressure fluctuations. For this purpose, pressure fluctuations were measured experimentally. The amplitude and duration of coherent wave train of pressure fluctuations were investigated using digital filtration. The transient response was calculated for stabilization of forced oscillations of the coating in approximation of local deformation. The response of coating was analyzed with considerations of its inertial properties and limited duration of coherent harmonics action of pressure fluctuations. It is shown that a compliant coating interacts not with the whole spectrum of pressure fluctuations, but only with a frequency range near the first resonance. According to the analysis, with increasing elasticity modulus of the coating material E, deformation amplitude decreases as 1/E, and dimensionless velocity of the coating surface decreases as $1/\sqrt{E}$. For sufficiently hard coatings, deformation amplitude becomes smaller than the thickness of viscous sublayer, while surface velocity remains comparable to vertical velocity fluctuations of the flow.

The Surface Sizing Effect of Oxidized Starch on the Printability of Newspaper (국산 신문 용지에서 산화전분에 의한 표면 사이징 처리가 인쇄적성에 미치는 영향)

  • 하영백
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.15 no.2
    • /
    • pp.25-40
    • /
    • 1997
  • This research was carried out to investigated the effect of base paper and latex binder on printability and obtical properties of coated paper. Especially, it examined the effect of th pH of vase paper surface and functional groups of latices on the interactions between coating color components and on the structure of coated layer. It was found that the behavior of coating color containing amphoeric latex depends on the pH in the boundary region between coating color and base paper. Thus, the coating color formulated with amphoteric latex formed bulky coating layer by inducing stronger interaction between paper surface and coating components than the coating color with anionic latex. The coated paper with amphoteric latex showed better optical properties (i.e.gloss and optical) and printability (i.e. ink receptivity, wet ink receptivity, and ink set off) than the conventional anionic latex in the acidic and alkaline paper. However, dry pick strength of the coated paper was less decreased. This result indicated that amphoteric latex could also be applied practically to the alkaline paper.

  • PDF

Effects of Zn-Flash Coating on Hydrogen Evolution, Infusion, and Embrittlement of Advanced-High-Strength Steel During Electro-Galvanizing (Zn-Flash 코팅 처리가 전기아연도금 시 초고강도 강재의 수소 발생, 유입 및 취화 거동에 미치는 영향)

  • Hye Rin Bang;Sang Heon Kim;Sung Jin Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.341-350
    • /
    • 2023
  • In the present study, effects of a thin Zn-flash coating on hydrogen evolution, infusion, and embrittlement of advanced high strength steel during electro-galvanizing were examined. The electrochemical permeation technique in conjunction with impedance spectroscopy was employed under applied cathodic polarization. Moreover, a slow-strain rate test was conducted to evaluate loss of elongation (i.e., indicative of hydrogen embrittlement (HE)) and examine fracture surfaces. Results showed that the presence of a thin Zn-flash coating, even when it was not distributed uniformly, reduced hydrogen evolution rate and substantially impeded infusion of hydrogen into the steel substrate. This was primarily due to a hydrogen overvoltage on Zn coating and trapping of hydrogen at the interface of Zn coating/flash coating/steel substrate. Consequently, the sample with flash coating had a smaller HE index than the sample without flash coating. These results suggest that a thin Zn-flash coating could be an effective technical strategy for mitigating HE in advanced high-strength steels.

EFFECT OF GOLD ELECTRODEPOSIT OF PD-AG, NI-CR ALLOYS ON THE COLOR OF VENERRED RESIN (Pd-Ag 및 Ni-Cr 합금의 금 전착이 전장 레진의 색채에 미치는 영향)

  • Yang, Hong-So;Park, Yeong-Joon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.645-661
    • /
    • 1995
  • As the mechanical property of composite resin improved, composite resin has been widely used esthetic dentistry. In the field of esthetic dentistry, the color of prosthetic material is very important. The purpose of this study was to evaluate the color difference of specimens, by the types of alloys and gold electrodeposit. Experimental groups were as follows : Group Prec : Au-Pt alloy with no gold coating and no resin veneer. Group Semi : Pd-Ag alloy with no gold coating and no resin veneer. Group BAse : Ni-Cr alloy with no gold coating and no resin veneer. Group Gsem : Pd-Ag alloy with no gold coating and no resin veneer. Group Gbas : Ni-Cr alloy with no gold coating and no resin veneer. Group PreR : Resin veneer on the Pd-Ag alloy without gold coating. Group SemR : Resin veneer on the Pd-Ag alloy without gold coating. Group GbsR : Resin veneer on the Ni-Cr alloy with gold coating Group BasR : Resin veneer on the Ni-Cr alloy without gold coating. In this study, colors of metal surfaces and veneered resins were evaluated by the CIE $L^{*}a^{*}b$ system. The results obtained were as follows : 1. different alloy types and gold coating make the $L^{*}a^{*}b$ system. 2. The ${\Delta}E^*$ab value between groups semi and Base was less than 1.5 and there was no $a^*$ and $b^*$ value difference between groups Gsem and Gbas 3. The values of $L^*$ and $a^*$ ain groups GsemR and GbasR were so similar that the ${\Delta}E^*$ab value was as small as 0.58. 4. In resin specimens with gold coated semiprecious or base alloys showed yellower and redder deviation than the resin specimens with precious alloy. 5. The ${\Delta}E^*$ab values between goups PreR-GsemR and groups PreR-GbasR were as small as 2.68 and 2.22 respectively.

  • PDF

New Coating Method for Sustained Drug Release: Surface Modification of ePTFE Grafts by inner coating PLGA

  • Kim, Hyeseon;Park, Seohyeon;Kim, Dae Joong;Park, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1333-1336
    • /
    • 2014
  • Expanded polytetrafluoroethylene (ePTFE) grafts have been used as vascular access for many patients suffering from end stage renal disease. However, the vascular graft can cause significant clinical problems such as stenosis or thrombosis. For this reason, many studies have been performed to make drug eluting graft, but initial burst is major problem in almost drug eluting systems. Therefore we used biodegradable polymer to reduce initial burst and make sustained drug delivery. The ePTFE grafts were dipped into a paclitaxel-dissolved solution and then PLGA-dissolved solution was passed through the lumen of ePTFE. We analyzed whether the dose of paclitaxel is enough and the loading amount of PLGA on ePTFE graft increases according to the coating solution's concentration. Scanning electron microscope (SEM) images of various concentration of PLGA showed that the porous surface of graft was more packed with PLGA by tetrahydrofuran solution dissolved PLGA. In addition, in vitro release profiles of Ptx-PLGA graft demonstrated that early burst was gradually decreased as increasing the concentration of PLGA. These results suggest that PLGA coating of Ptx loaded graft can retard drug release, it is useful tool to control drug release of medical devices.