• Title/Summary/Keyword: e-clinical data

Search Result 781, Processing Time 0.031 seconds

The effect of repeat processing on the color stability of lithium disilicate glass-ceramic (리튬디실리케이트 글라스-세라믹의 반복 성형이 색 안정성에 미치는 영향)

  • Jeon, Byung-Wook
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.175-180
    • /
    • 2021
  • Purpose: This study investigates the effect of repeated use of lithium disilicate glass-ceramics on color stability. Methods: In this study, 2 types of lithium disilicate glass-ceramics were used and they were divided into 4 groups after 1st, 2nd, 3rd, and 4th heat pressing. The L*, a*, and b* values of all specimens were measured using the VITA Easyshade Advance 4.0. These values was used to determine the ∆E value and transparency. IBM SPSS Statistics ver. 24.0, a statistical significance level of 0.05 and one-way ANOVA were used for all data. Results: In all groups, the L* and b* values were the lowest in the specimens subjected to the 4th heat pressing and the corresponding a* value was the highest. All specimens showed ∆E values of ≤3.3, indicating color changes that were not visible with the naked eye, and the color difference increased with the number of repeated heat pressing. The transparency of all specimens decreased as the number of repeated uses increased. Conclusion: According to the number of repeated heat pressing, the color difference of Rosetta SP (HASSBIO) was larger than that of IPS e.max Press (Ivoclar Vivadent), but it was clinically acceptable in all groups. Moreover, transparency decreased as the number of heat presses increased in all groups. According to the above findings, the lithium disilicate glass-ceramic has high color stability due to repeated heat pressing, implying that it can be used in clinical settings regularly.

Health Information Manager's Role in IT-Based Medical Environment (IT기반 의료 환경에서 보건정보관리자의 역할)

  • Jeon, Yun-Hee
    • Journal of Digital Convergence
    • /
    • v.11 no.6
    • /
    • pp.213-219
    • /
    • 2013
  • The purpose of this study is to suggest a plan for which Medical Record Technician, who has main task as efficient creation and management of medical information, is changed successfully to health information manager in IT-based medical environment. According to this research objective, it carried out an analysis on future model(To-be) for being changed into health information manger in addition to analysis of the current situation for task as medical record technician. The subject materials of analyzing the present status included 1) state-exam subjects for medical record technician 2) qualification examination subjects for health information manger 3) analytical data of the current task for domestically medical record technicians 4) symposiums and educational topics for the recent 3 years in Korean Medical Record Association. Future-model(To-be) data included 'HIM Professional Roles in E-HIM (R)' suggested by AHIMA(American Health Information Management Association). Through a comparative analysis of these materials, a role of being needed currently medical record technicians' new entry was analyzed to be Business change manager, IT training specialist, Consumer advocate, Clinical alerts and reminders manager, and Enterprise application specialist.

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

Review of recent developments for intra-oral scanners (현재 존재하는 구강 스캐너에 대한 고찰)

  • Choi, Jong-Hoon;Lim, Young-Jun;Lee, Won-Jin;Han, Jung-Suk;Lee, Seung-Pyo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.112-125
    • /
    • 2015
  • Making a model that is an accurate replica of the oral structure requires precision and efficiency. Nowadays, rapid technological advances bring digitalization in dentistry. One of the most important works in digital dentistry is three-dimensional modeling of the oral cavity and digitizing the 3D data. Among the three components of CAD/CAM, (1) data capture component (digitizers), (2) design component (CAD software), (3) manufacturing component (CAM), the basic component that has a significant impact on the other processes is the data capture component, i.e. intra-oral scanners. This literature review discusses the principles and clinical use of intra-oral scanners in dentistry based on recent publications of the past 5 years using the PubMed and Google Scholar databases.

A Study of the Attitudes of Nurses toward the Geriatric Nursing Care (노인간호에 대한 간호원의 태도조사연구)

  • 최경옥
    • Journal of Korean Academy of Nursing
    • /
    • v.6 no.2
    • /
    • pp.1-9
    • /
    • 1976
  • Presently, there is increasing demand for geriatric nursing care because of increasing preparation of elderly population due to extended age. Of particular importance in determining the effectiveness of nursing care given to the elderly is the attitude of the nurse toward the elderly patient. Knowledge of the various changes that usually occur with aging will enable the nurse to help an aged Person maximize his potential in illness and in health. The objectives of this study were : 1. To delineate the attitudes of nurses toward the geriatric nursing care. 2. To learn the influencing factors affecting the attitudes of nurses toward the geriatric nursing care. The study population defined and randomly selected is 225 nurses at one general hospital, one private hospital, two national hospitals in Seoul during the period of October l0th -20th, 1975. The questionnaire method was used. Respondents were 140 nurses. X$^2$- test and t- test were employed in analyzing the data. The questionnaire form included 54 statements which concerned the attitudes of nurses to-ward geriatric nursing care. It was divided into five areas : 1) General characteristics of study population. 2) The nurse's concepts of elderly. 3) Care of the geriatric patient. 4) Interpersonal relationship with geriatric patient. 5) Teaching of the geriatric patient. Each of the 54 statements of the questionnaire was considered to be either Positive or Negative. A Positive response was assigned the value of+1 , and a Negative response or no response was assigned the value of O. The results of the study were as follows : 1. The Investigation of attitudes of nurses toward geriatric nursing care. a. Data indicated , respondents have negative attitudes in their. concepts of elderly (74.3%) b. Data indicated respondents have positive attitudes in care of geriatric patient (64.3%). c. Data indicated respondents have positive attitudes in interpersonal relationship with geriatric patient (85% ). 4. Data indicated respondents have positive attitudes in teaching of geriatric patient (89.3%). 2. The results of study regarding the five hypothesis were as follows : a There was significant difference in the mean scores between the attitudes of nurses toward the geriatric nursing care and level of education of the nurse. b. There was no significant difference between the attitudes of nurses toward the geriatric nursing care and clinical experience, but there was significant difference between care of the geriatric patient and clinical experience. c. There was no significant difference between the attitudes of nurses toward the geriatric nursing care and shift most frequently worked, but there was significant difference between care of the geriatric patient and shift most frequently worked. d. There was no significant difference in the mean scores between the attitudes of nurses toward the geriatric nursing care and marital status, but there was significant difference in the mean scores between interpersonal relationship, teaching of geriatric patient and marital status. e, There was no significant difference in the mean scores between the attitudes of nurses toward the geriatric nursing care and experience with elderly, but there was significant difference in the mean scores between care of geriatric patient and experience with elderly.

  • PDF

Prostate Cancer Epidemiology in a Rural Area of North Western Greece

  • Grivas, N.;Hastazeris, K.;Kafarakis, V.;Tsimaris, I.;Xousianitis, Z.;Makatsori, A.;Raptis, P.;Aspiotis, S.;Ioachim, E.;Ntemou, A.;Kitsiou, E.;Malamou-Mitsi, V.;Sofikitis, N.;Kordela, V.;Papandreou, C.;Agnantis, N.J.;Stavropoulos, N.E.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.999-1002
    • /
    • 2012
  • Epirus is a rural area of North-Western Greece. We reviewed data from 4 hospitals for 4.975 patients who underwent prostate biopsy in Epirus in the twelve year period from 1999 to 2010. Two six -year periods were compared (1999-2004 and 2004-2010). All cases of prostate cancer confirmed by biopsy were recorded and age-standardized incidence rates per 100,000 males were calculated. We also recorded the clinical stage for patients diagnosed in our hospital and correlated this with PSA and Gleason scores. Percentage of positive prostate biopsies was also calculated. There were a total of 1714 new cases during 1999-2010 and the mean annual age-adjusted incidence was 34/100.000. The mean incidences during 1999-2004 and 2005-2010 were 26/100,000 and 42/100,000, respectively. The mean age at diagnosis was 74. The most common Gleason score was 6 and the prevalent clinical stage was T2. Median PSA at diagnosis was 10.8 ng/ml. There was a significant difference between stage cT4 and all other stages regarding PSA value (p=0.000). A positive correlation was found between Gleason score and PSA (p=0.013). These results are in accordance with the incidence rise recorded in neighboring countries of South-East Europe. However we should keep in mind the risk of overdiagnosis and the detection of low-risk cancers that would not have caused morbidity or death during a man's lifetime anyway.

A Clinical Study on CSP Attachment Partial Denture (CSP 를 이용한 정밀부착형 국부의치에 관한 임상적 연구)

  • Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.7-16
    • /
    • 1981
  • The technology of precision attachments has developed at such a pace that from a very few T-shaped attachments and bar attachments from the years 1915 to 1935 since removable bridge utilizing a T-shaped intracoronal attachment was constructed by Dr. Herman E.S. Chayes in 1906. There are now more than 120 models of the most diversified designs, ready made or laboratory fashioned. In 1971, 126 attachments were listed and classified by Mensor in his E M Attachment Selector. This selector consists of five charts giving specifications as to type, vertical dimensions, application, type of resilience, size of movement, type of retention and type of material and alloy. Thus the E M Attachment Selector is a useful guide for dentists to choose the attachment for his patients. But dentists should apply the attachment in each patient's case according to an accurate diagnosis and treatment plan. This paper is a case report of removable partial dentures utilizing CSP, PD and Bar attachment on a patient who needed full mouth reconstruction. Patient has right first, second molar and left first molar on the upper arch and also left first molar, first premolar and right canine on the lower arch. (Fig. 5)All remaining teeth are relatively healthy in their supporting tissues. On upper arch, ring shape CSP attachment was designed on left first molar and modified ring shape CSP attachment was designed on right first and second molar as the direct retainer of the removable partial denture. Full palatal coverage was used as the major connector in this case. (Fig. 23) On lower arch, author first splinted with a fixed bridge between left first molar and second premolar and a splint bar between left second premolar and right canine. (Fig. 11) A lower removable partial denture in which was designed with an Aker clasp on the left first molar and a PD attachment on .the right canine was constructed. (Fig. 17) This denture could get additional support from anterior splint bar. After both removable partial dentures were delivered to the patient (Fig. 26), author evaluated function of the dentures and supporting structures of the abutment teeth by means of clinical and X-ray examinations for eighteen months. According to the examination data author came to the conclusion that the prognosis of this case was excellent.

  • PDF

Prevalence of hepatitis E virus antibodies in cattle in Burkina Faso associated with swine mixed farming

  • Tialla, Dieudonne;Cisse, Assana;Ouedraogo, Georges Anicet;Hubschen, Judith M.;Tarnagda, Zekiba;Snoeck, Chantal J.
    • Journal of Veterinary Science
    • /
    • v.23 no.3
    • /
    • pp.33.1-33.10
    • /
    • 2022
  • Background: Endemic circulation of human-specific hepatitis E virus (HEV) genotypes 1 and 2 may occult the importance of sporadic zoonotic HEV transmissions in Africa. Increasing numbers of studies reporting anti-HEV antibodies in cattle and the discovery of infectious HEV in cow milk has raised public health concern, but cattle exposure has seldom been investigated in Africa. Objectives: This study aimed at investigating the role of cows in the epidemiology of HEV in Burkina Faso and farmers habits in terms of dairy product consumption as a prerequisite to estimate the risk of transmission to humans. Methods: Sera from 475 cattle and 192 pigs were screened for the presence of anti-HEV antibodies while HEV RNA in swine stools was detected by reverse transcription polymerase chain reaction. Data on mixed farming, dairy product consumption and selling habits were gathered through questionnaires. Results: The overall seroprevalence in cattle was 5.1% and herd seroprevalence reached 32.4% (11/34). Herd seropositivity was not associated with husbandry practice or presence of rabbits on the farms. However, herd seropositivity was associated with on-site presence of pigs, 80.7% of which had anti-HEV antibodies. The majority of farmers reported to preferentially consume raw milk based dairy products. Conclusions: Concomitant presence of pigs on cattle farms constitutes a risk factor for HEV exposure of cattle. However, the risk of HEV infections associated with raw cow dairy product consumption is currently considered as low.

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.

Subclinical left ventricular dysfunction in children after hematopoietic stem cell transplantation for severe aplastic anemia: a case control study using speckle tracking echocardiography

  • Kim, Beom Joon;Moon, Kyung Pil;Yoon, Ji-Hong;Lee, Eun-Jung;Lee, Jae Young;Kim, Seong Koo;Lee, Jae Wook;Chung, Nack Gyun;Cho, Bin;Kim, Hack Ki
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.4
    • /
    • pp.190-195
    • /
    • 2016
  • Purpose: Severe aplastic anemia (SAA), a fatal disease, requires multiple transfusion, immunosuppressive therapy, and finally, hematopoietic stem cell transplantation (HSCT) as the definitive treatment. We hypothesized that iron overloading associated with multiple transfusions and HSCT-related complications may adversely affect cardiac function. Left ventricular (LV) function was assessed in children after HSCT for SAA. Methods: Forty-six consecutive patients with a median age of 9.8 years (range, 1.5-18 years), who received HSCT for SAA and who underwent comprehensive echocardiography before and after HSCT, were included in this study. The data of LV functional parameters obtained using conventional echocardiography, tissue Doppler imaging (TDI), and speckle-tracking echocardiography (STE) were collected from pre- and post-HSCT echocardiography. These data were compared to those of 40 age-matched normal controls. Results: In patients, the LV ejection fraction, shortening fraction, end-diastolic dimension, mitral early diastolic E velocity, TDI mitral septal E' velocity, and STE LV longitudinal systolic strain rate (SSR) decreased significantly after HSCT. Compared to normal controls, patients had significantly lower post-HSCT early diastolic E velocity and E/A ratio. On STE, patients had significantly decreased LV deformational parameters including LV longitudinal systolic strain (SS), SSR, and diastolic SR (DSR), and circumferential SS and DSR. Serum ferritin levels showed weak but significant correlations (P<0.05) with LV longitudinal SS and SSR and circumferential SS and DSR. Conclusion: Subclinical LV dysfunction is evident in patients after HSCT for SAA, and was associated with increased iron load. Serial monitoring of cardiac function is mandatory in this population.