• 제목/요약/키워드: dynamic vibration system

검색결과 2,013건 처리시간 0.026초

Dynamic System Analysis of Machine Tool Spindles with Magnet Coupling

  • Kim, Seong-Keol
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권4호
    • /
    • pp.87-93
    • /
    • 2002
  • In this study, basic concepts of magnet were introduced, and dynamic characteristics of magnet coupling were explored. Based on these characteristics, it was proposed how to analyze transverse and torsional vibrations of a spindle system with magnet coupling. Proposed theoretical approaches were applied to a precision power transmission system machined for this study, and the transverse and torsional vibrations were simulated. The force on magnet coupling was shown as a form of nonlinear function of the gap and the eccentricity. Also, the form of torque transmitted by magnet coupling was considered as a sinusoidal function. Main spindle connected to a coupling of a follower part was assumed to be a rigid body. Nonlinear partial differential equation was derived to be as a function of angular displacement. By using the equation, torsional vibration analysis of a spindle system with magnet coupling was performed. Free and forced vibration analyses of a spindle system with magnetic coupling were explored by using FEM.

저속 2행정 디젤엔진의 종진동 댐퍼 동특성에 관한 연구 (A Study on the Dynamic Characteristics of Axial Vibration Damper for Two Stroke Low Speed Diesel Engine)

  • 이돈출;김정렬;김의간
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권2호
    • /
    • pp.113-121
    • /
    • 1994
  • Since two oil shocks in 1970s, all of engine makers have persevered in their efforts to reduce specific fuel consumption and to increase engine power rate as much as possible in marine diesel engines. As a result, the maximum pressure in cylinders of these engines has been continuously increased. It causes direct axial vibration. The axial stiffness of crank shaft is low compared to old types of engine models by increasing the stroke/bore ratio and its major critical speed might occur within engine operation range. An axial damper, therefore, needs to be installed in order to reduce the axial vibration amplitude of the crankshaft. Usually the main critical speed of axial vibration for the propulsion shafting system with a 4-8 cylinder engine exists near the maximum continuous revolution(MCR). In this case, when the damping coefficient of the damper is increased within the allowance of the structural strength, its stiffness coefficient is also increased. Therefore, the main critical speed of axial vibration can be moved beyond the MCR. It has the same function as a conventional detuner. However, in the case of a 9-12 cylinder engine, the main critical speed of axial vibration for the propulsion shafting system exists below the MCR and thus the critical speed cannot be moved beyond the MCR by using an axial damper. In this case, the damping coefficient of an axial damper should be adjusted by considering the range of engine revolution, the location and vibration amplitude of the critical speed, the fore and aft vibration of the hull super structure. It needs to clarify the dynamic characteristics of the axial vibration damper to control the axial vibration appropriately. Therefore authors suggest the calculation method to analyse the dynamic characteristics of axial vibration damper. To confirm the calculation method proposed in this paper, it is applied to the propulsion shafting system of the actual ships and satisfactory results are obtained.

  • PDF

수위변화에 따른 파이프 시스템의 진동 특성 변화에 대한 연구 (A research on Dynamic characteristic of Submerged pipe ; Support, Flange, Upper pump)

  • 정휘권;김종윤;박규해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.699-705
    • /
    • 2013
  • This paper presents vibration testing, control, and finite element analysis of a piping system, which is subjected to the changes in fluid levels. Nuclear power plants typically employ a cooling system that uses sea water. These systems are subjected to dynamic characteristic changes caused by sea-level variations, which introduces failures of cooling system components. Therefore in this study, analytical and experimental studies were performed to understand the effect of sea-level changes on the dynamic characteristics of piping systems. It was shown that, as the sea-level increases, pipe's natural frequencies decreases in relation to its mode shape. A 1/14 scale model was also built to compare the results obtained by the analytical study. A good agreement between experiment and analytical studies were observed. Finally, an on-line resonant frequency identification system was proposed and developed, which utilizes piezoelectric transducers as sensors and actuators, in order to avoid catastrophic failure of piping systems.

  • PDF

2축 짐벌 안정계 동특성 고찰을 통한 해석 모델링 검증에 관한 연구 (Study for verification of Analysis modeling with investigating dynamic characteristic about 2 axies gimbals system)

  • 김만달;이용덕;김성국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.180-183
    • /
    • 2005
  • 2 axis gimbals systems are extensively used in various tracking devices for attaining the system's objective. Designers are sometimes passing over the dynamic characteristics of system in vibrating condition In this paper, 2 axis gimbals systems including interface elements is modeled with finite elements. To verify this model, the finite element model is refined by using the experimental model data. The refined model is simulated with I-DEAS and MSC.NATRAN's FRF(Frequency response Function) and RRA(Random vibration Response Analysis) function to get dynamic characteristics of 2 axis gimbals system.

  • PDF

스마트 Hull 구조물의 모달 해석 및 진동 제어 (Modal Analysis and Vibration Control of Smart Hull Structure)

  • 손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.299-304
    • /
    • 2008
  • Dynamic characteristics of smart hull structure are investigated and active vibration control performance is evaluated. Dynamic model of smart hull structure with surface bonded Macro-fiber Composite (MFC) actuators is established by analytical method. Equations of motion of the host hull structure are derived based on Donnell-Mushtari equilibrium equations for a thin cylindrical shell. A general model for the interaction between hull structure and MFC actuator is included in the dynamic model. Modal analysis is then conducted and mode shapes and corresponding natural frequencies are investigated. After constructing of the optimal control algorithm, active vibration control performance of the proposed system is evaluated. It has been shown that structural vibration can be reduced effectively with proper control input.

  • PDF

스마트 Hull 구조물의 모달 해석 및 진동 제어 (Modal Analysis and Vibration Control of Smart Hull Structure)

  • 손정우;최승복
    • 한국소음진동공학회논문집
    • /
    • 제18권8호
    • /
    • pp.832-840
    • /
    • 2008
  • Dynamic characteristics of smart hull structure are investigated and active vibration control performance is evaluated. Dynamic model of smart hull structure with surface bonded macro-fiber composite(MFC) actuators is established by analytical method. Equations of motion of the host hull structure are derived based on Donnell-Mushtari equilibrium equations for a thin cylindrical shell. A general model for the interaction between hull structure and MFC actuator is included in the dynamic model. Modal analysis is then conducted and mode shapes and corresponding natural frequencies are investigated. After constructing of the optimal control algorithm, active vibration control performance of the proposed system is evaluated. It has been shown that structural vibration can be reduced effectively with proper control input.

진동시험용 치구의 실험적 구조변경 설계 (Experimental Structural Dynamic Modification of Fixture for Vibration Testing)

  • 정의봉;오영세;김준엽
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.180-186
    • /
    • 1998
  • Vibration test fixture is used in random vibration control testing. The specified reference spectrum should be transmitted equally to the specimen attachment points on the fixture. In most practical cases, however, spectrum at each of specimen attachment points may be quite different from the specified reference spectrum because of the dynamic characteristics of vibration test fixture. This paper proposes the method of experimental dynamic modification of fixture system for vibration test so that the reference spectrum can be transmitted to the specimen attachment points without distortion. The stiffness of mounts of specimen and the thickness of fixture are considered as design variables. The frequency response functions of specimen used for input data are obtained from vibration testing, and the frequency response functions of fixture are obtained from finite element modeling. The sensitivities of frequency response functions at specimen attachment points to the mount stiffness are derived from synthesis method of transfer function. And the sensitivities to the thickness of fixture are also derived from finite element modeling. The presented method is verified by computer simulation and vibration testing.

  • PDF

System identification of the suspension tower of Runyang Bridge based on ambient vibration tests

  • Li, Zhijun;Feng, Dongming;Feng, Maria Q.;Xu, Xiuli
    • Smart Structures and Systems
    • /
    • 제19권5호
    • /
    • pp.523-538
    • /
    • 2017
  • A series of field vibration tests are conducted on the Runyang Suspension Bridge during both the construction and operational stages. The purpose of this study is devoted to the analysis of the dynamic characteristics of the suspension tower. After the tower was erected, an array of accelerometers was deployed to study the evolution of its modal parameters during the construction process. Dynamic tests were first performed under the freestanding tower condition and then under the tower-cable condition after the superstructure was installed. Based on the identified modal parameters, the effect of the pile-soil-structure interaction on dynamic characteristics of the suspension tower is investigated. Moreover, the stiffness of the pile foundation is successfully identified using a probabilistic finite model updating method. Furthermore, challenges of identifying the dynamic properties of the tower from the coupled responses of the tower-cable system are discussed in detail. It's found that compared with the identified results from the freestanding tower, the longitudinal and torsional natural frequencies of the tower in the tower-cable system have changed significantly, while the lateral mode frequencies change slightly. The identified modal results from measurements by the structural health monitoring system further confirmed that the vibrations of the bridge subsystems (i.e., the tower, the suspended deck and the main cable) are strongly coupled with one another.

열간 사상압연기에서의 진동 원인 (The Cause of Vibration at Finishing Stands in a Hot Strip Mill)

  • 손붕호;노용래;이영호
    • 소음진동
    • /
    • 제4권1호
    • /
    • pp.43-50
    • /
    • 1994
  • Chatter vibration of a rolling machine in steel plants has a significant effect on thickness quality of the products. The cause and mechanism of the mill chattering is addressed through measurement of vibration and dynamic torque. An FFT system and an FM telemetry system are employed to collect data at several locations of possible damages. The results reveal the followings as sources of the mill vibration. The first is defects in roller bearings of a work roll chock. The second is instability of an oil film bearing in a backup roll chock, which has been investigated with a theoretical model describing the phenomenon. Dynamic torque is not the direct cause of mill vibration but rather influenced by the vibration. Appropriate treatment methods are suggested to address each of the above sources.

  • PDF

선형동흡진기의 매개변수가 감쇠진동계의 진동특성에 미치는 영향 (Effects of parameters of a linear dynamic vibration absorber on the vibrational characteristics of damped vibrational systems)

  • 윤장상;이양우;송창섭
    • 한국정밀공학회지
    • /
    • 제6권4호
    • /
    • pp.136-144
    • /
    • 1989
  • This paper presents the vibrational characteristics of linear damped vibrational systems with a linear dynamic absorber. The amplitude ratios of main vibrational system are derived from the equation of motion for the system, and optimal natural frequency ratio and damping ratio of dynamic absorber are obtained by computer simu- lation, which minimize the amplitude ratio of main vibrational system for the whole range of the frequency ratio. And, the effects of the parameters on the amplitude ratios are investigated. As the results, the effect of the natural frequency ratio on the amplitude ratio of main vibrational system is more important than that of the damping ratio of dynamic absorber as damping ratio of main vibrational system becomes larger. For the case of large damping ration of main vibrational system becomes larger. For the case of large damping ratio of main vibration system, the amplitude ratios are not decreased dramationally in spite of inoreasing mass ratio.

  • PDF