• Title/Summary/Keyword: dynamic tests

Search Result 2,298, Processing Time 0.034 seconds

Deformation Characteristic by Compression in High-Nitrogen Austenitic Stainless Steel (고질소강 오스테나이트계 스테인레스강의 압축변형특성)

  • Lee, J.W.;Kim, D.S.;Kim, B.K.;Lee, M.R.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.139-141
    • /
    • 2007
  • Compression tests were carried out to investigate morphologies of compressed specimen, deformation microstructure and stress-strain relation in high-nitrogen austenite stainless steel. Tests were performed under a wide range of temperature and, with true strain rates up to $\dot{\varepsilon}$ =0.05, 0.1, 0.5 and $1.0s^{-1}$. The activation energy of loading force was equal to plastic deformation energy within the temperature range of $900^{\circ}C$ to $1250^{\circ}C$. Dynamically recrystallized grain size decreased with an increasing strain rate and temperature. Flow stresses and deformation microstructures, were used to quantify the critical strain rate and recrystallized grain size. The grain size versus strain rate-temperature map obtained in the study was in good agreement with the deformation microstructures of compressed specimens.

  • PDF

Study on Methodology for Reducing Dead Zone Flow within Chlorine Contactor Installing Porous Baffles (유공벽을 이용한 우류식 염소접촉조 사류 저감 방안 연구)

  • Park, Hyun-Ho;Park, No-Suk;Cha, Min-Whan;Kim, Sa-Dong;Won, Chan-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.519-525
    • /
    • 2010
  • From the results of tracer test for the existing chlorine contactor in Y water treatment plant, $T_{10}$ and $T_{10}$/T were calculated as 130 min and 0.16, respectively. Therefore it required the modification schemes for improving hydraulic efficiency, surrogated by T10 and $T_{10}$/T, and disinfection performance. In this study, in order to reduce dead zone within contactor, the installation of porous baffles in the near of each corner was suggested and verified using transient CFD(Computational Fluid Dynamics) simulation technique and tracer tests on dynamic condition. From the results of simulation and tracer tests, it was revealed that porous baffles installed have been effective to reduce dead zone within contactor, and increase plug flow fraction.

OPTIMUM AIR PRESSURE FOR AN AIR-CELL SEAT TO ENHANCE RIDE COMFORT

  • YOO W. S.;PARK D. W.;KIM M. S.;HONG K. S.
    • International Journal of Automotive Technology
    • /
    • v.6 no.3
    • /
    • pp.251-257
    • /
    • 2005
  • Several air cells are installed in the seat cushion to adjust the stiffness of seat by changing the air pressure. To select proper air pressure in the air cells, two kinds of tests are performed. For the pressure distribution on the seat, the maximum pressure and mean pressure are compared. And for the dynamic ride values, SEAT (Seat Effective Amplitude Transmissibility) values are calculated and compared. These experiments are carried out with three different drivers, three different vehicle speeds on the highway and two different speed on the primary road, and three different air pressures. From the real car tests, optimum air cell pressure depending on the vehicle speed and driver's weight are recommended.

An Experimental Study on the Dynamic Behavior of a Marine Riser (석유 시추보호관의 운동특성에 관한 실험적 고찰)

  • 김용철;이판묵;홍사영
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.46-58
    • /
    • 1988
  • The experimental investigations on the motion characteristics of a marine riser both in air and water were performed. The static deflections and natural frequencies of the riser in air including the effect of static offset, were obtained from the experiment. These results were compared with those of theoretical prediction by using a simple asymptotic formula. In order to investigate the nonlinear motion characteristics of the riser subject to nonlinear viscous drag and large displacement, the forced oscillation tests both in air and water were performed. In the forced oscillation tests in air, it was found that the transverse motion due to geometrical nonlinearity grows when the amplitude of in-line oscillation exceeds a certain critical value, say, order of 1-2 diameters. The planar motions of the riser in water due to vortex shedding and the geometrical nonlinearity were described. Some of these results were also compared with those of theoretical analysis, which uses a numerical perturbation technique based on the derived linear asymptotic solutions, and found to be generally in good agreement.

  • PDF

A Study on the Liquefaction Resistance of Anisotropic Sample under Real Earthquake Loading (이방 구속 조건에서 실지진 하중을 이용한 액상화 저항강도 특성 분석)

  • Lee, Chae-Jin;Jeong, Sang-Seom;Kim, Soo-Il
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1188-1191
    • /
    • 2009
  • In this study, cyclic triaxial tests were performed with the samples which were anisotropically consolidated using irregular earthquake loading to consider in-situ condition and seismic wave. The consolidation pressure ratio(K) was changed from 0.5 to 1.0. The Ofunato and Hachinohe wave are applied as irregular earthquake loading and liquefaction resistance strength was estimated from excess pore water pressure(EPWP) ratio. As results of the cyclic triaxial tests, buildup of EPWP ratio increased as K value increased. It shows, that the isotropically consolidated sands is more susceptible to liquefaction than anisotropically consolidated sands under equal conditions such as confining pressure and dynamic loading.

  • PDF

Cyclic behavior of interior beam-column connections in non-seismic RC frames at different loading rates

  • Dhakal, Rajesh P.;Pan, Tso-Chien
    • Structural Engineering and Mechanics
    • /
    • v.23 no.2
    • /
    • pp.129-145
    • /
    • 2006
  • This paper provides an insight into the response of non-seismic reinforced concrete (RC) building frames to excitations of different frequencies through experimental investigation. The results of cyclic loading tests of six full-scale RC beam-column sub-assemblies are presented. The tested specimens did not have any transverse reinforcement inside the joint core, and they were subjected to quasi-static and dynamic loading with frequencies as high as 20 Hz. Some important differences between the cyclic responses of non-seismic and ductile RC frames are highlighted. The effect of excitation frequency on the behavior of non-seismic joints is also discussed. In the quasi-static tests, shear deformation of the joint panel accounted for more than 50% of the applied story drift. The test results also showed that higher-frequency excitations are less detrimental than quasi-static cyclic loads, and non-seismic frames can withstand a higher load and a larger deformation when they are applied faster.

A Development of a Transient Hydrogen Generation Model for Metal-Water Interactions

  • Lee, Jin-Yong;Park, Goon-Cherl;Lee, Byung-Chul
    • Nuclear Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.549-558
    • /
    • 2000
  • A transient model for hydrogen generation in molten metal-water interactions was developed with separate models for two stages of coarse mixing and stratification. The model selves the mechanistic equations (heat and mass transfer correlation, heat conduction equation and the concentration diffusion equation) of each stage with non-zero boundary conditions. Using this model, numerical simulations were performed for single droplet experiments in the Argonne National Laboratory tests and for FITS tests that simulated dynamic fragmentation and stratification. The calculation results of hydrogen generation showed better agreement to the experiment data than those of previous works. It was found from the analyses that the steam concentration to be reached at the reaction front might be the main constraint to the extent of the metal droplet oxidized. Also, the hydrogen generation rate in the coarse mixing stage was the higher than that in the stratification stage. The particle size was the most important factor in the coarse mixing stage to predict the amount of hydrogen generation.

  • PDF

On-line Tests of on the Yang-Yang Pumped Storage Plant for the Reactive Power Limits and the OEL Dynamics (양양양수 온라인 무효전력 운전범위 시험과 과여자제한기(OEL) 동특성 시험)

  • Kim, Dong-Joon;Moon, Young-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1343-1350
    • /
    • 2007
  • This paper describes the tests on the reactive power output limit and the Over-Excitation Limiter (OEL) dynamics of a generation unit. The suggested test methods on reactive limit can identify the allowable maximum/minimum reactive power at 100% rated MW in the steady-state unit operation condition. The on-line OEL test method can identify the time characteristics of OEL with the generation output at 50% of the rated MW. These methods are validated by applying to four Yang-Yang pumped storage units with 282 rated MVA each.

Running Bucket Vibration Test of Steam Turbines (증기 터빈 버켓의 회전 진동 시험)

  • 박종포;신언탁;김호종
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.96-100
    • /
    • 1997
  • A design modification was made on the 9-th stage wheel dovetail of a high-intermodiate pressure (HIP) turbine rotor for a fossil power plant that necessitates the use of new long-shank buckets for the row. A bucket vibration test is necessary to verify that the new 9-th stage buckets have adequate frequency margin from a nozzle passing frequency when running at speed. A finite element analysis (FEA) has been performed using a commercial S/W to approximately estimate bucket natural frequencies, and thus to help the vibration test. A row of the new buckets has been assembled on the HIP rotor for the vibration tests using dynamic balancing facilities. The tests have been done during deceleration run with air excitation. The test results are compared with the calculation using our empirical formula, and show that the modified design meets the frequency-margin requirements.

  • PDF

Seismic Test of a 1/2 Scale Model of Wood House with Tiled Roof (기와집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Jeon, Bong-Hee;Kim, Byung-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.362-367
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with tiled roof was performed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF