• Title/Summary/Keyword: dynamic tests

Search Result 2,298, Processing Time 0.031 seconds

High Speed Tensile Tests of Steel Sheets for an Auto-body at the Intermediate Strain Rate (중변형률 속도에서의 차체용 강판의 고속 인장실험)

  • Lim, Ji-Ho;Kim, Seok-Bong;Kim, Jin-Sung;Huh, Hoon;Lim, Jong-Dae;Park, Sung-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.127-134
    • /
    • 2005
  • This paper introduces a newly developed high speed material testing apparatus for tensile tests at the strain rate up to 500/sec. The tensile properties of sheet metals are indispensable for the accurate crashworthiness analysis of auto-bodies since the local strain rate reaches to 500/sec in the car crash. An appropriate experimental method has to be developed to acquire the tensile properties at the intermediate strain rate ranged from 0.003/sec to 200/sec. Tensile tests of various different steel sheets for an auto-body were perform ed to obtain the dynamic properties with respect to the strain rate. The dimensions of specimens that can provide the reasonable results were determined by the finite element analysis. A special jig fixture of a load cell is designed to reduce the load ringing phenomenon induced by unstable stress propagation at the high strain rate. Stress-strain curves were acquired for each steel sheet from the dynamic tensile test and utilized to obtain the relationship of the stress to the strain rate.

Dynamic Centrifuge Tests for Evaluating the Earthquake Load of the Structure on Various Foundation Types (다양한 기초 형식에 따른 단자유도 구조물 지진하중 평가를 위한 동적 원심모형실험)

  • Ha, Jeong Gon;Jo, Seong Bae;Park, Heon Joon;Kim, Dong Kwan;Kim, Dong Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.285-293
    • /
    • 2016
  • Soil-foundation-structure interaction (SFSI) is one of the important issues in the seismic design for evaluating the exact behavior of the system. A seismic design of a structure can be more precise and economical, provided that the effect of SFSI is properly taken into account. In this study, a series of the dynamic centrifuge tests were performed to compare the seismic response of the single degree of freedom(SDOF) structure on the various types of the foundation. The shallow and pile foundations were made up of diverse mass and different conjunctive condition, respectively. The test specimen consisted of dry sand deposit, foundation, and SDOF structure in a centrifuge box. Several types of earthquake motions were sequentially applied to the test specimen from weak to strong intensity of them, which is known as a stage test. Results from the centrifuge tests showed that the seismic responses of the SDOF structure on the shallow foundation and disconnected pile foundation decreased by the foundation rocking. On the other hand, those on the connected pile foundation gradually increased with intensity of input motion. The allowable displacement of the foundation under the strong earthquake, the shallow and the disconnected pile foundation, have an advantage in dissipating the earthquake energy for the seismic design.

Effect of Skirt Length on Behavior of Suction Foundations for Offshore Wind Turbines Installed in Dense Sand Subjected to Earthquake Loadings (조밀한 모래지반에 설치된 해상풍력 석션기초의 스커트길이에 따른 지진하중시 거동특성)

  • Choo, Yun Wook;Olalo, Leonardo;Bae, Kyung-Tae
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.4
    • /
    • pp.202-211
    • /
    • 2016
  • This study aims to analyze seismic responses of suction foundations for offshore wind turbine. For this purpose, dynamic centrifuge model tests were carried out. The skirt length of the suction foundation is a critical element for bearing mechanism against environmental loads. Thus, dynamic centrifuge model tests were performed and analyzed for three suction foundation models with the ratios of skirt length to suction foundation diameter of 0.5, 0.75, and 1 installed in dense sand. As results, the acceleration amplification at the suction foundation, residual settlement, and residual tilting angle were compared.

A vision-based system for dynamic displacement measurement of long-span bridges: algorithm and verification

  • Ye, X.W.;Ni, Y.Q.;Wai, T.T.;Wong, K.Y.;Zhang, X.M.;Xu, F.
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.363-379
    • /
    • 2013
  • Dynamic displacement of structures is an important index for in-service structural condition and behavior assessment, but accurate measurement of structural displacement for large-scale civil structures such as long-span bridges still remains as a challenging task. In this paper, a vision-based dynamic displacement measurement system with the use of digital image processing technology is developed, which is featured by its distinctive characteristics in non-contact, long-distance, and high-precision structural displacement measurement. The hardware of this system is mainly composed of a high-resolution industrial CCD (charge-coupled-device) digital camera and an extended-range zoom lens. Through continuously tracing and identifying a target on the structure, the structural displacement is derived through cross-correlation analysis between the predefined pattern and the captured digital images with the aid of a pattern matching algorithm. To validate the developed system, MTS tests of sinusoidal motions under different vibration frequencies and amplitudes and shaking table tests with different excitations (the El-Centro earthquake wave and a sinusoidal motion) are carried out. Additionally, in-situ verification experiments are performed to measure the mid-span vertical displacement of the suspension Tsing Ma Bridge in the operational condition and the cable-stayed Stonecutters Bridge during loading tests. The obtained results show that the developed system exhibits an excellent capability in real-time measurement of structural displacement and can serve as a good complement to the traditional sensors.

Study on Correlation between Dynamic Cone Resistance and Shear Strength for Frozen Sand-Silt Mixtures under Low Confining Stress (낮은 구속응력에서 모래-실트 혼합토의 동결강도 평가를 위한 동적 콘 저항력 및 전단강도 상관성 연구)

  • Kim, Sangyeob;Lee, Jong-Sub;Hong, Seungseo;Byun, Yong-Hoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.1
    • /
    • pp.5-12
    • /
    • 2016
  • Investigation of in-situ ground in cold region is difficult due to low accessibility and environmental factors. In this study, correlation between dynamic cone resistance and shear strength is suggested to estimate the strength of frozen soils by using instrumented dynamic cone penetrometer. Tests were conducted in freezing chamber after preparing sand-silt mixture with 2.3% water content. Vertical stresses of 5 kPa and 10 kPa were applied during freezing, shearing, and penetration phase to compare the dynamic cone resistance and shear strength. The dynamic cone resistance, additionally, is calculated to minimize the effect of energy loss during hammer impact. Experimental results show that as the shear strength increases, the dynamic cone penetration index (DCPI) decreases nonlinearly, while the dynamic cone resistance increases linearly. This study provides the useful correlation to evaluate strength properties of the frozen soils from the dynamic cone penetration and direct shear tests.

Precise Flow Stress Analysis for the Occurrence of Dynamic Ferritic Transformation and Dynamic Recrystallization of Austenite in Low Carbon Steel (고온 변형 곡선을 이용한 동적 재결정 해석과 동적 상변태의 조기 예측)

  • Park, Nokeun
    • Korean Journal of Metals and Materials
    • /
    • v.56 no.11
    • /
    • pp.779-786
    • /
    • 2018
  • There have been previous attempts to observe the occurrence of dynamic ferritic transformation at temperatures even above $Ae_3$ in a low-carbon steel, and not only in steels, but recently also in titanium alloys. In this study, a new approach is proposed that involves treating true stress-true strain curves in uniaxial compression tests at various temperatures, and different strain rates in 0.1C-6Ni steel, which is a model alloy used to decelerate the kinetics of ferrite transformation from austenite. The initial flow stress up to peak stress was used to analyze the change in dynamic softening phenomena, such as dynamic recovery, dynamic recrystallization, and dynamic transformation. It is worth mentioning that for predicting the occurrence of dynamic transformation, flow stress before reaching peak stress is much more sensitive to the change in the dynamic softening rate due to dynamic transformation, compared to peak stress. It was found that the occurrence of dynamic ferritic transformation could be successfully obtained even at temperatures above $Ae_3$ once the deformation condition was satisfied. This deformation condition is a function of both the strain rate and the deformation temperature, which can be described as the Zener - Hollomon parameter. In addition, the driving force of dynamic ferritic transformation might be much less than that of the dynamic recrystallization of austenite at a given deformation condition. By applying this technique, it is possible to predict the occurrence of dynamic transformation more sensitively compared with the previous analysis method using peak stress during deformation.

Testing and Modeling of Generator Control Systems for Stability Studies (발전기 제어계 동특성 시험 및 수리모형 수립)

  • Oh, Tae-Kyoo;Moon, Young-Hwan;Choi, Kyung-Sun;Kwon, Tae-Won;Lyu, Seung-Heon
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.379-382
    • /
    • 1991
  • The dynamic characteristics and mathematical models of the KEPCO's generator control systems have been derived by on-line tests. Measuring the responses for small disturbances in the inputs, the parameters of governing systems, excitation systems, and power system stabilizers have been determined. An overview of the field tests, parameter identification, and model verification is presented.

  • PDF

Development of Evaluation Technique for Occupant Safety in KHST by Sled Test (Sled를 이용한 한국형 고속전철 승객안전도 평가 기술개발)

  • 윤영한;구정서
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.205-210
    • /
    • 2001
  • This paper uses a dynamic sled test approach to understand the effects of impact speed on the risk of occupant in KHST. The sled impact tests simulate a predefined accident scenarios. This study shows the effect of relative velocity between occupant and struck vehicle while occupant is impacted to a front seat's seatback. Although, base on the current accident scenarios, KHST is performed well enough to protect average adult male occupants. However, Results from the tests indicate small size occupant or higher impact speed may cause sever neck and femur injuries.

  • PDF

Design St Implementation of a High-Speed Navigation Computer for Strapdown INS (스트랩다운 관성항법시스템 고속 항법컴퓨터 설계와 구현)

  • 김광진;최창수;이태규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.29-29
    • /
    • 2000
  • This paper describes the design and implementation of a high-speed navigation computer to achieve precision navigation performance with Strapdown INS. The navigation computer inputs are velocity and angular increment data from the ISA at the signal of the 2404Hz interrupt and performs the removal of gyro block motion and the compensation of high dynamic errors at the 200Hz. For high-speed and high-accuracy, the computer consists of the 68040 micro-processor, 128k Memories, FPGAs, and so on. We show that the computer satisfies the required performance by In-Run navigation tests.

  • PDF

INVESTIGATION OF SUBSURFACE CAVITIES UNDER PAVEMENT STRUCTURES WITH DYNAMIC CONE PENETROMETER TESTS (동적관입시험(DCP TESTS)에 의한 포장체 하부구조내 공동(空洞)현상에 관한 조사)

  • 김종렬
    • Journal of Korean Society of Transportation
    • /
    • v.16 no.2
    • /
    • pp.99-105
    • /
    • 1998
  • 이 논문은 포장체 하부구조내 공동(空洞)현상에 대한 위치를 규명하는데 있어서 신속하면서, 간단하고 신뢰성있는 방법을 제시하고자 한다. 동적관입시험(DCP)을 사용하여 콘크리트 슬라브하부의 노상토에 대한 강도를 측정하였다. 타격회수에 대한 침하의 양으로 측정되는 동적관입침하율을 비교하여 포장체하부의 연약지반에 대한 위치를 규명하였다. 콘크리트 포장체 하부의 공동(空洞)현상 및 연약화된 노상토에 대한 정보를 얻고자 하는 엔지니어를 위하여 시험방법 및 결과분석 등을 현장시험을 통하여 체계적으로 설명하였다.

  • PDF