• Title/Summary/Keyword: dynamic tests

Search Result 2,298, Processing Time 0.028 seconds

Effect of Density Variation of High Tenacity PET Interlace Yarn on the Physical Properties of Pack Style Shock Energy Absorber (고강력 PET Interlace Yarn 밀도변화가 Pack Style Shock Energy Absorber의 물성에 미치는 영향)

  • Cho, Jin Won;Kwon, Sang Jun;Choe, Jong Deok;Kim, Sang Tae;Ji, Byung Chul;Yang, Seong Baek;Yeum, Jeong Hyun
    • Textile Coloration and Finishing
    • /
    • v.27 no.2
    • /
    • pp.132-141
    • /
    • 2015
  • Fall-arrest systems(maximum arrest force and allowable free-fall) have been widely applied to provide a safe stop during fall incidents for various industrial activities. Fabric structure affects on the mechanical properties of shock energy absorber. The object of this study is to perform the basic research for the evaluation of the capacity of fall arrest energy absorber in relation to the different interlace yarn density. In this work, pack style energy absorber was prepared by weaving 10 types(Interlace yarn density used high tenacity PET 1000D : 60, 59, 58, 57, 56, 55, 54, 53, 52, 51). The paper presents the results of theoretical investigations of the performance of adjustable absorber during fall arrest. Dynamic load tests based on the EU fall protection equipment standard(CE : EN355:2002) were conducted. Results showed that the maximum arrest force by dynamic load test of energy absorber was satisfied with global standard(below 6,000N). Also, Maximum allowable free-fall of energy absorber showed below 1.75m.

Comparison of sensorimotor training and cycling exercise for dynamic balance and gait function stroke patient: Single subject design (뇌졸중 환자의 동적균형 및 보행에 대한 감각운동 훈련과 사이클링 운동의 효과 비교 : 개별사례연구)

  • Yang, Hae-Duck;Oh, Duck-Won
    • Journal of Korean Physical Therapy Science
    • /
    • v.17 no.1_2
    • /
    • pp.1-9
    • /
    • 2010
  • Background: The objective of this study was to determine whether sensorimotor training using an unstable surface affects dynamic balance and gait function in patients with hemiparesis, and to compare the effect of sensorimotor training with that of cycling exercise. Methods: Two subjects with post-stroke hemiparesis volunteered to participate in this study. Single-subject A-B design with alternating treatment was used for this study. Baseline(A) and intervention(B) phases were performed for 7 and 8 sessions, respectively. Sensorimotor training and cycling exercise were performed for 20 minutes in randomized order. Assessment tools were made by using a step test, timed up and go(TUG) test, and 6-minute walk test(6MWT). Results: Each of the participants improved in all three tests after the two interventions. Participants 1 and 2 showed the improvement for their assessment score after sensorimotor training in the step test by 42.1%(p<.05) and 58%, in the TUG, 31% and 19.5%, and in the 6MWT test, 32.3% and 10.6%(p<.05), respectively. After cycling exercise, participants 1 and 2 also improved in the step test by 32.5% and 53.1%, in the TUG, 27.4% and 18%, and in the 6MWT test, 28.8% and 3%. In statistical analysis between the two interventions, sensorimotor training showed a significant increased values in the step test for participant 1 and the 6MWT for participant 2 as compared with those of cycling exercise. Conclusion: Sensorimotor training and cycling exercise are helpful for improving dynamic balance and gait capacity. Furthermore, sensorimotor training may be more helpful than cycling exercise.

  • PDF

Improvement of Dynamic Behavior of Shunt Active Power Filter Using Fuzzy Instantaneous Power Theory

  • Eskandarian, Nasser;Beromi, Yousef Alinejad;Farhangi, Shahrokh
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1303-1313
    • /
    • 2014
  • Dynamic behavior of the harmonic detection part of an active power filter (APF) has an essential role in filter compensation performances during transient conditions. Instantaneous power (p-q) theory is extensively used to design harmonic detectors for active filters. Large overshoot of p-q theory method deteriorates filter response at a large and rapid load change. In this study the harmonic estimation of an APF during transient conditions for balanced three-phase nonlinear loads is conducted. A novel fuzzy instantaneous power (FIP) theory is proposed to improve conventional p-q theory dynamic performances during transient conditions to adapt automatically to any random and rapid nonlinear load change. Adding fuzzy rules in p-q theory improves the decomposition of the alternating current components of active and reactive power signals and develops correct reference during rapid and random current variation. Modifying p-q theory internal high-pass filter performance using fuzzy rules without any drawback is a prospect. In the simulated system using MATLAB/SIMULINK, the shunt active filter is connected to a rapidly time-varying nonlinear load. The harmonic detection parts of the shunt active filter are developed for FIP theory-based and p-q theory-based algorithms. The harmonic detector hardware is also developed using the TMS320F28335 digital signal processor and connected to a laboratory nonlinear load. The software is developed for FIP theory-based and p-q theory-based algorithms. The simulation and experimental tests results verify the ability of the new technique in harmonic detection of rapid changing nonlinear loads.

Evaluation of Effects on Impact Resonance Test for Determining Modulus of Asphalt Concrete (아스팔트 콘크리트 탄성계수 결정을 위한 충격공진시험 영향요소 평가)

  • Kweon, Gi-Chul;Lee, Jae-Hoan
    • International Journal of Highway Engineering
    • /
    • v.9 no.2 s.32
    • /
    • pp.89-99
    • /
    • 2007
  • The stiffness of the asphalt concrete is represented by the complex modulus $E^*$, which is very important properties in the mechanistic design of flexible pavement system. The moduli of asphalt concrete were generally determined by dynamic modulus test. However, the dynamic modulus testing method is too complex, expensive, and time consuming to be applicable on a production basis. The IR(Impact Resonance) method has been shown to be a truly simple nondestructive testing method which produces very repetitive, consistent results. The major object of this study was to estimate of the effects on IR tests for determining modulus of asphalt concrete including impact position, specimen support condition, impact steel ball size and sampling rate. The variations of IR test results with various testing conditions are within ${\pm}2.7%$.

  • PDF

Tensile Properties of Zr-0.4Sn-1.5Nb-0.2Fe (Zr-0.4Sn-1.5Nb-0.2Fe 합금의 인장특성)

  • Lee M. H.;Kim J. H.;Choi B. K.;Jeong Y. H.
    • Korean Journal of Materials Research
    • /
    • v.14 no.10
    • /
    • pp.713-718
    • /
    • 2004
  • To study the dynamic strain aging behavior of Zr-0.4Sn-1.5Nb-0.2Fe sample tube for nuclear fuel cladding in the range of pressurized water reactor (PWR) operation temperature, the tensile tests of the tube specimens, which had been finally heat-treated at $470^{\circ}C\;and\;510^{\circ}C$, had been carried out with the strain rate $1.67{\times}10^{-2}/s\;and\;8.33{\times}10^{-5}/s$ at the various temperatures from room temperature to $500^{\circ}C$. It was observed that the elongation of the specimens got shortened as the temperature increased from $200^{\circ}C\;to\;340^{\circ}C$. The specimens that were finally heat-treated at $470^{\circ}C$ showed a plateau more remarkably on the plot of yield strength-temperature than those heat-treated at $510^{\circ}C$. In the range of $310\sim400^{\circ}C$, the strain rate sensitivity of the specimens finally heat-treated at $510^{\circ}C$ was $30.4\%\sim33.7\%$ lower but the work hardening exponent index of the specimens was a little higher than that without dynamic strain aging effect.

Causal Relationships between Vessel Export and Economic Growth in Korean Shipbuilding Industry (우리나라 조선산업에서 선박수출과 경제성장의 인과성)

  • Kim, Chang-Beom
    • Journal of Korea Port Economic Association
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • This paper analyses the dynamic causal relationship between vessel export and economic growth using annual data over the period from 1977 to 2006. Tests for ADF unit-roots, the dynamic vector using Johansen's multiple cointegration procedure, dynamic vector error correction model and impulse response function are presented. The findings of the Granger test suggest that vessel export Granger-causes economic growth in the short-run and economic growth Granger-causes exports in the short and long-run. The empirical results of impulse-response analysis show that the vessel export to a shock in real GDP responds positively and the real GDP responds positively to the shocks in vessel export. Also, the results indicate that the impact of vessel export shock on the real GDP is short-lived.

  • PDF

Characteristics of Cyclic Drying-Wetting on Strength of Solidified Soil Mixed Porosity Silica (다공성 실리카를 혼합한 경화토의 건습반복 강도특성)

  • Kim, Donggeun;Bang, Seongtaek;Oh, Sewook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.10
    • /
    • pp.29-34
    • /
    • 2014
  • In order to examine strength properties depended on climate changes of solidified soil amended by porosity silica which enhance harms of cement, this study conducts a wetting and drying repetition test and then, attempts to verify strength properties before and after solidified soil gets environmental influence. Test pieces for the unconfined compression test changed the mixing ratio of solidified soil compared to mixed soil weigh to 5 %, 10 % and 15 %. For each step, it was created by mixing 0.5 %, 1.0 % and 1.5 % of wood chips, and curing period for 7, 14, and 28 days. Then, the wetting and drying repetition process was repeated 0, 3, 6, and 12 cycles to analyze mechanical properties. To also evaluate changes of relative dynamic elastic modulus before and after the wetting and drying, dynamic elastic modulus tests were conducted when each cycle was completed.

Measurement of Dynamic Strains on Composite T-Joint Subjected to Hydrodynamic Ram Using PVDF Sensors (PVDF 센서를 이용한 수압램 하중을 받는 복합재 T-Joint의 동적 변형률 측정)

  • Go, Eun-Su;Kim, Dong-Geon;Kim, In-Gul;Woo, Kyeongsik;Kim, Jong-Heon
    • Composites Research
    • /
    • v.31 no.5
    • /
    • pp.238-245
    • /
    • 2018
  • The hydrodynamic ram (HRAM) phenomenon is one of the main types of ballistic battle damages of a military aircraft and has great importance to airframe survivability design. The HRAM effect occurs due to the interaction between the fluid and structure, and damage can be investigated by measuring the pressure of the fluid and the dynamic strains on the structure. In this paper, HRAM test of a composite T-Joint was performed using a ram simulator which can generate HRAM pressure. In addition, calibration tests of PVDF sensor were performed to determine the circuit capacitance and time constant of the measurement system. The failure behavior of the composite T-Joint due to HRAM pressure was examined using the strain gauges and a PVDF sensor which were attached to the surface of the composite T-Joint.

The Effects of Repetitive Sit-to-Stand Training with a Paretic-side Asymmetrical Foot Position on the Balance of Chronic Stroke Subjects

  • Park, Jae Hyo;Kim, Young Mi;Lee, Na Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.169-173
    • /
    • 2015
  • Purpose: This study aimed to improve the asymmetrical weight-bearing ratio, by applying different repetitive sit-to-stand training methods to the paretic-side foot of hemiplegic patients, as well as to provide the necessary information for applying balance training with hemiplegic patients. Methods: The subjects were divided into two groups: a spontaneous foot group and an asymmetrical foot group. They all performed repetitive sit-to-stand training five times a week for a total of six weeks. The sit-to-standing movement was studied using standardized clinical tests. The Biodex Balance System, Time up and go test (TUG), 5 times sit-to-stand test (5XSST), and functional reach test (FRT) were used to measure the static and dynamic standing balance of the patients. Results: In the balance system measurement, the results for the overall index, ant-post index, med-lat index, fall risk index, 5XSST, and FRT after the training differed significantly between the comparison groups (p<0.05). In the evaluation of dynamic balance, the differences in TUG did not differ significantly between the comparison groups after the training (p>0.05). Conclusion: The study found that the asymmetrical group showed significant increases in static and dynamic balance in comparison to the spontaneous group after repetitive sit-to-stand training. Based on this result, it is clear that training in an asymmetrical position with the paretic foot back can increase the left-right stability limit and the anterior-posterior stability limit, thus improving balance control.

Seismic vulnerability assessment of a historical building in Tunisia

  • El-Borgi, S.;Choura, S.;Neifar, M.;Smaoui, H.;Majdoub, M.S.;Cherif, D.
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.209-220
    • /
    • 2008
  • A methodology for the seismic vulnerability assessment of historical monuments is presented in this paper. The ongoing work has been conducted in Tunisia within the framework of the FP6 European Union project (WIND-CHIME) on the use of appropriate modern seismic protective systems in the conservation of Mediterranean historical buildings in earthquake-prone areas. The case study is the five-century-old Zaouia of Sidi Kassem Djilizi, located downtown Tunis, the capital of Tunisia. Ambient vibration tests were conducted on the case study using a number of force-balance accelerometers placed at selected locations. The Enhanced Frequency Domain Decomposition (EFDD) technique was applied to extract the dynamic characteristics of the monument. A 3-D finite element model was developed and updated to obtain reasonable correlation between experimental and numerical modal properties. The set of parameters selected for the updating consists of the modulus of elasticity in each wall element of the finite element model. Seismic vulnerability assessment of the case study was carried out via three-dimensional time-history dynamic analyses of the structure. Dynamic stresses were computed and damage was evaluated according to a masonry specific plane failure criterion. Statistics on the occurrence, location and type of failure provide a general view for the probable damage level and mode. Results indicate a high vulnerability that confirms the need for intervention and retrofit.