• Title/Summary/Keyword: dynamic reponses

Search Result 16, Processing Time 0.021 seconds

Fuzzy Control of Servo System by manipulate membership function (멤버쉽함수의 조정에 의한 Servo System의 Fuzzy 제어)

  • 이오걸;송호신;김이곤;심영진;이준탁
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.117-122
    • /
    • 1998
  • A servo system requires faster and more accurate dynamic reponses. Generally a PD control is mainly used to obtain the precision, and in the other hand a fuzzy control to improve the transient response and to cope with the nonlinearity of systems. Recently hybrid control, which is attempted to combine the advantages of PD control and a Fuzzy control was proposed, but this technique requires complicate design procedures. Therefore in this paper, designed on the Fuzzy controller with a various series rules, width of membership functions. And also it was showed to have the excellent adaptive performances against disturbances and the usefulness of this controller from the results of simulations.

  • PDF

Earthquake Response Reduction Simulation of a 3 Story Building Structure by Stockbridge Damper (스톡브릿지댐퍼를 사용한 지진시 구조물의 응답제어 시뮬레이션)

  • Chang, Seongkyu;Kim, Dookie;Raman, Mohammad Sabbir;Kim, Hyung Seong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.295-300
    • /
    • 2016
  • In this study, Stockbridge damper was adopted to reduce the reponses of structures under earthquakes. A finite element analysis software, SAP2000, was used to simulate the structural response and the control device under dynamic loads. A 3 story frame model and the proposed control device, Stockbridge damper, were designed under laboratory conditions. In this research, a pendulum type tuned mass damper (PTMD) was also adopted in order to compare with the Stockbridge damper. Harmonic loads were applied to verity the control performance of both control devices in each mode. In results, it has been found that the Stockbirdge damper decreases significantly the responses of the structure more than the PTMD under the harmonic loadings. The El Centro and Northridge earthquakes were also applied in order to investigate the performance by both control devices. The responses of the building demonstrate that the Stockbridge damper reduces the response of the building structure during earthquakes more effectively than the PTMD.

Optimal Design for Seismically Isolated Bridges with Frictional Bearings (마찰받침이 있는 지진격리교량의 최적설계)

  • Lee, Gye-Hee;You, Sang-Bae;Ha, Dong-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.5A
    • /
    • pp.399-406
    • /
    • 2010
  • In this paper, the optimization of frictional bearings that applied to improve the seismic performance of conventional bridges were conducted. The nonlinear dynamic analysis of steel bridges and concrete bridges are carried out with the El Centro and artificial earthquake motions, and the reponses of the bridges were optimized by genetic algorithm. The object functions were considered with two parameters, such as shear forces and displacements at bearing, and the optimum object functions were searched by varying the weighting factors of the two parameters. As results, in case of the steel bridges, the optimum results were obtained when larger weight factor was imposed to the shear force. However, in case of concrete bridges, larger weight factor was need to the displacement for optimum results.

Vibration Control of Structures Using Viscoelastic Dampers Installed in Expansion Joints (신축이음부에 설치된 점탄성감쇠를 이용한 구조물의 진동제어)

  • Kim, Jin-Koo;Ryou, Jin-Gook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.33-42
    • /
    • 2004
  • The usual practice of placing viscoelastic dampers (VED) in the inter-story of building structures frequently interfere with spatial planning and obstruct internal view. These shortcomings can be overcome by installing VED in seismic joints or in expansion joints which are usually hidden under a cover. This study investigates the effect of installing VED in seismic joints to reduce earthquake-induced dynamic reponses. Parametric studies were conducted using 3-DOF systems connected by VED and subjected to earthquake excitations to investigate the effectiveness of the proposed scheme. Nonlinear dynamic analyses were carried out with five-story structures composed of different structure systems and connected by seismic joints. According to the analysis results the use of VED in seismic joints turned out to be effective as long as the natural frequencies of the connected structures are different enough.

Application of Seismic Analysis and Design Method on the Bridges by Spectral Analysis Method (스펙트럼해석법에 의한 교량의 지진해석 및 설계방법의 적용)

  • 김운학;유영화;신현목
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.17-29
    • /
    • 1997
  • Single-mode spectral analysis method is usually applied to a small-scale bridges with the simple geometric shape and uses only fundamental period to estimate the elastic earthquake forces and the displacements of the substructure. On the other hand, multi-mode spectral analysis method may be used instead if the possibilities of potential damage are developed when considering significance, scale, and geometric shape of briages. Since the dynamic responses of bridge can be significantly different depending on the modeling techniques for the restraint and support conditions etc, it may be misled to the unexpected results. In this study the dynamic analysis program which can model and analyze the bridge as a two- or three-dimensional framed structure is developed and verified with the results of other reliable program. Using this program together with the post processor, the designer can easily and readily obtain the reponses(moments, base shears, and displacements)of bridges necessary to design purpose. And further from the analysis results according to the variations of type, scale, and restraint and supprot conditions of bridges including sectional properties, applications of the effective and desirable seismic design are presented.

  • PDF

A Numerical Study on the Strain Based Monitoring Method for Lateral Structural Response of Buildings using FBG Sensors (FBG를 이용한 변형률 기반 건물의 횡방향 구조반응 모니터링 기법에 관한 해석적 연구)

  • Choi, Se Woon;Park, Keunhyoung;Kim, Yousok;Park, Hyo Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.263-269
    • /
    • 2013
  • In this study, the strain based monitoring method to evaluate the lateral structural response of buildings is presented and an applicability of the proposed method is confirmed through the numerical study. It is assumed that the fiber Bragg grating(FBG) strain sensor is employed to measure the strain response of members due to the excellent properties such as multiplexing, and higher sampling frequency. These properties of FBG sensors is proper for buildings the a lot of sensors are required to monitor the reponses of those. FBG sensors measure the strain response of vertical members and are employed to calculate the curvatures of members using the measured strain responses. Then the lateral displacement, and lateral acceleration is evaluated based on the curvatures of vertical members. Additionally, these dynamic responses of buildings are used to evaluate the dynamic properties of buildings such as the natural frequencies and mode shapes using the frequency domain decomposition(FDD) method. Through the application of nine-story steel moment frame example structure, it is confirmed that the proposed method is appropriate to evaluate the lateral structural responses and dynamic properties of buildings.