• 제목/요약/키워드: dynamic power consumption

검색결과 424건 처리시간 0.025초

실시간 시스템에서 태스크별 평균 실행 시간을 활용한 동적 전압 조절 방법 (Dynamic Voltage Scaling Using Average Execution Time in Real Time Systems)

  • 방철원;김용석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅲ
    • /
    • pp.1379-1382
    • /
    • 2003
  • Recently, mobile embedded systems used widly in various applications. Managing power consumption is becoming a matter of primary concern because those systems use limited power supply. As an approach reduce power consumption, voltage can be scaled down. according to the execution time and deadline. By reducing the supplying voltage to 1/N power consumption can be reduced to 1/N. DPM-S is a well known method for dynamic voltage scaling. In this paper, we enhanced DPM-S by using average execution time aggressively. The frequency of processor is calculated based in average execution time instead of worst case execution time. Simulation results show that our method achieve up to 5% energy savings than DPM-S.

  • PDF

GUI-based Power Consumption Analysis Tool for Lower Power Embedded S/W Development in ESTO

  • Kim, Doo-Hyun;Lee, Keun Soo;Jung, Changhee;Woo, Duk-Kyun
    • 대한임베디드공학회논문지
    • /
    • 제2권3호
    • /
    • pp.164-173
    • /
    • 2007
  • In this paper, we present a time-triggered mechanism for providing energy consumption profiles in the level of C functions. The similar mechanisms have already been introduced at the previous researches such as PowerScope and ePRO. Instead, we, in this paper, introduce our efforts to extend these researches to incorporate power domains and DVS(Dynamic Voltage Scaling), then to provide GUI-based tool as a plug-in to ESTO which is an IDE for Embedded S/W development based on Eclipse. From our experimental results, we could conclude that our approach worked and produced consistent energy consumption profiles on the DVS-applied program codes, and also displayed function level and time domain power consumption information with diverse presentation skills such as tables, phi-chart, bar-chart, 2-D graphs, consequently, is expected to provide more ease-to-use and productive IDE for lower power embedded S/W developers.

  • PDF

Deep Submicron 공정의 멀티미디어 SoC를 위한 저전력 움직임 추정기 아키텍쳐 (Low-Power Motion Estimator Architecture for Deep Sub-Micron Multimedia SoC)

  • 연규성;전치훈;황태진;이성수;위재경
    • 대한전자공학회논문지SD
    • /
    • 제41권10호
    • /
    • pp.95-104
    • /
    • 2004
  • 본 논문에서는 0.13㎛ 이하의 deep sub-micron 공정처럼 누설 전류가 심한 공정을 이용하여 멀티미디어 SoC를 설계할 때, 가장 전력 소모가 높은 움직임 추정 기법의 전력 소모를 줄이기 위한 저전력 움직임 추정기의 아키텍쳐를 제안하였다. 제안하는 아키텍쳐는 기존의 동적 전력 소모만을 고려한 구조와는 달리 정적 전력 소모까지 고려하여 누설 전류가 심한 공정에 적합한 구조로, 효율적인 전력 관리가 필수적인 동영상 전화기 등의 각종 휴대용 정보기기 단말기에 적합한 형태이다. 제안하는 아키텍쳐는 하드웨어 구현이 용이한 전역 탐색 기법 (full search)을 기본으로 하며 동적 전력 소모를 줄이기 위하여 조기 은퇴(early break-off) 기법을 도입하였다. 또한 정적 전력 소모를 줄이기 위하여 전원선 잡음을 고려한 메가블록 전원 차단 기법을 사용하였다. 제안된 아키텍쳐를 멀티미디어 SoC에 적용하였을 때의 효용성을 검증하기 위해 시스템 수준의 제어 흐름과 저전력 제어 기법을 개발하였으며, 이를 바탕으로 시스템 수준에서의 소모 전력을 계산하였다. 모의실험 결과 0.13㎛ 공정에서 전력 소모가 50% 정도로 감소함을 확인할 수 있었다. 선폭의 감소와 칩 내부 발열량의 증가로 인한 누설 전류의 증가를 고려할 때, 기존의 동적 전력 소모만을 고려한 구조는 전력 감소 효율이 점점 나빠짐에 반하여 제안하는 움직임 추정기 아키텍쳐는 안정적인 전력 감소 효율을 보여주었다.

Analysis on Application of Flywheel Energy Storage System for offshore plants with Dynamic Positioning System

  • Jeong, Hyun-Woo;Kim, Yoon-Sik;Kim, Chul-Ho;Choi, Sung-Hwan;Yoon, Kyoung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권7호
    • /
    • pp.935-941
    • /
    • 2012
  • This paper describes a study of conventional electrical rig and simulated application of Flywheel Energy Storage system on the power system of the offshore plants with dynamic positioning system with the following aims: improve fuel consumption on engines, prevent blackout and mitigate voltage sags due to pulsed load and fault. Fuel consumption has been analyzed for the generators of the typical drilling rigs compared with the power plant with Flywheel Storage Unit which has an important aid in avoiding power interruption during DP (Dynamic Positioning) operation. The FES (Fly wheel Energy storage System) releases energy very quickly and efficiently to ensure continuity of the power supply to essential consumers such as auxiliary machinery and thrusters upon main power failure. It will run until the standby diesel generator can start and supply the electric power to the facilities to keep the vessel in correct position under DP operation. The proposed backup method to utilize the quick and large energy storage Flywheel system can be optimized in any power system design on offshore plant.

Design of Low Power All-Optical Networks with Dynamic Lightpath Establishment

  • Hirata, Kouji;Ito, Kohei;Fukuchi, Yutaka;Muraguchi, Masahiro
    • Journal of Communications and Networks
    • /
    • 제18권4호
    • /
    • pp.551-558
    • /
    • 2016
  • In multifiber all-optical networks, optical amplifiers are used for amplifying multiple optical signals with different wavelengths in fibers. An optical amplifier operates when any of lightpaths passes through it. Therefore, it should simultaneously amplify as many lightpaths as possible for efficiently utilizing its power. This paper proposes a dynamic lightpath establishment scheme considering the use efficiency of the optical amplifiers and the depletion of the wavelength resources in multifiber all-optical networks. The proposed scheme provides a routing and wavelength assignment strategy that reduces both the power consumption of the optical amplifiers and the blocking probability of the lightpath establishment. Through simulation experiments, we demonstrate the effectiveness of the proposed scheme.

OFDM 기반 광대역 멀티미디어 단말의 전력절감 효율 분석에 관한 연구 (Investigation of Power Saving Efficiency for the OFDM Based Multimedia Communication Terminal)

  • 문재필;이은서;김동환;이재식;장태규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.155-158
    • /
    • 2005
  • An invesitigation on power consumption of a mobile multimedia system using OFDM and MDVS technique is reported here. Analysis and simulation are performed to find the significances of proposed Microscopic Dynamic Voltage Scaling(MDVS) tehnique[4] on digital processor in terms of power saving. A study is also made to show power reduction in mobile multimedia system by incorporating OFDM modulation scheme in RF front-end. Finally, overall power consumption by functionally distinguished blocks ie. RF front-end, digital processor and human interface unit is shown here. Total power consumption is 8.2W for 2Mbps SD-quality WCDMA multimedia video service - the power consumption of digital processor is 3.9W(48%), the power consumption of RF front-end is 3.2W (36%), and the power consumption of interface is 1.8W(16%). Power saving of applying purposed MDVS technique is 35% in digital processor, and power saving of OFDM technique is 10-12dB in RF front-end.

  • PDF

추계적 프로세스 기반 동적 전력 관리 (Dynamic Power Management based on Stochastic Processes)

  • 노철우;김경민;폴 무두시
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2007년도 추계 종합학술대회 논문집
    • /
    • pp.197-200
    • /
    • 2007
  • 동적 전력 관리는 서로 다른 전력소모를 갖는 전력상태들을 시스템 구성 요소에 할당하고 상황별로 전력상태를 관리함으로써 시스템의 전력 소모를 현저하게 줄여줄 수 있다. 전력관리의 주 기능은 구성요소의 상태천이를 언제 수행하느냐 이며 이를 위하여 추계적 프로세스에 기반한 동적 전력관리 모델을 개발한다. 동적 모델은 시스템 큐와 다양한 모델링 기능을 표현할 수 있는 페트리 네트의 확장형인 SRN(Stochastic Reward Nets)을 이용하여 개발되며 성능분석을 함께 수행한다.

  • PDF

저진공 펌프의 운전 특성 (Operating Characteristics of Low Vacuum Pumps)

  • 임종연;심우건;정광화
    • 한국진공학회지
    • /
    • 제12권2호
    • /
    • pp.93-104
    • /
    • 2003
  • 저진공펌프의 내구성평가와 관련하여 펌프의 성능이나 상태의 저하에 관한 기술적 근거를 확보함으로써 펌프의 운전상태를 진단할 수 있는 기초기술을 확보할 수 있으며, 이는 진공펌프의 기계적 결함 및 성능평가 장치의 동적 응답과 신뢰도 구축에 중점을 두고 신호 분석을 통하여 실험적으로 기계적인 동적 특성을 확인하는 과정을 통하여 수행할 수 있다. 저진공펌프의 압축일에 소요되는 전력을 이론적으로 규명하고 펌프의 압축일을 계산하였으며, 소비전력에 대한 진공펌프의 에너지 효율을 예측하여 펌프 노화에 따르는 소비전력의 증가 원인을 규명하는 자료로 활용할 수 있다. 또한 저진공펌프의 가동 중에 측정한 진동, 압력신호, 배기속도 및 소비전력을 측정하고 분석하여 펌프 운전상태를 감시하는데 매우 유용한 인자가 무엇인지 확인하였으며 추후 연구의 방향과 내구성평가의 기초기술을 확보하였다.

Operation optimization of auxiliary electric boiler system in HTR-PM nuclear power plant

  • Du, Xingxuan;Ma, Xiaolong;Liu, Junfeng;Wu, Shifa;Wang, Pengfei
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2840-2851
    • /
    • 2022
  • Electric boilers (EBs) are the backup steam source for the auxiliary steam system of high-temperature gas-cooled reactor nuclear power plants. When the plant is in normal operations, the EB is always in hot standby status. However, the current hot standby operation strategy has problems of slow response, high power consumption, and long operation time. To solve these problems, this study focuses on the optimization of hot standby operations for the EB system. First, mathematical models of an electrode immersion EB and its accompanying deaerator were established. Then, a control simulation platform of the EB system was developed in MATLAB/Simulink implementing the established mathematical models and corresponding control systems. Finally, two optimization strategies for the EB hot standby operation were proposed, followed by dynamic simulations of the EB system transient from hot standby to normal operations. The results indicate that the proposed optimization strategies can significantly speed up the transient response of the EB system from hot standby to normal operations and reduce the power consumption in hot standby operations, improving the dynamic performance and economy of the system.

Energy and Service Level Agreement Aware Resource Allocation Heuristics for Cloud Data Centers

  • Sutha, K.;Nawaz, G.M.Kadhar
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권11호
    • /
    • pp.5357-5381
    • /
    • 2018
  • Cloud computing offers a wide range of on-demand resources over the internet. Utility-based resource allocation in cloud data centers significantly increases the number of cloud users. Heavy usage of cloud data center encounters many problems such as sacrificing system performance, increasing operational cost and high-energy consumption. Therefore, the result of the system damages the environment extremely due to heavy carbon (CO2) emission. However, dynamic allocation of energy-efficient resources in cloud data centers overcomes these problems. In this paper, we have proposed Energy and Service Level Agreement (SLA) Aware Resource Allocation Heuristic Algorithms. These algorithms are essential for reducing power consumption and SLA violation without diminishing the performance and Quality-of-Service (QoS) in cloud data centers. Our proposed model is organized as follows: a) SLA violation detection model is used to prevent Virtual Machines (VMs) from overloaded and underloaded host usage; b) for reducing power consumption of VMs, we have introduced Enhanced minPower and maxUtilization (EMPMU) VM migration policy; and c) efficient utilization of cloud resources and VM placement are achieved using SLA-aware Modified Best Fit Decreasing (MBFD) algorithm. We have validated our test results using CloudSim toolkit 3.0.3. Finally, experimental results have shown better resource utilization, reduced energy consumption and SLA violation in heterogeneous dynamic cloud environment.