• Title/Summary/Keyword: dynamic power

Search Result 4,559, Processing Time 0.031 seconds

Wide-area Frequency-based Tripped Generator Locating Method for Interconnected Power Systems

  • Kook, Kyung-Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.776-785
    • /
    • 2011
  • Since the Internet-based real-time Global Positioning System(GPS) synchronized widearea power system frequency monitoring network (FNET) was proposed in 2001, it has been monitoring the power system frequency in interconnected United States power systems and numerous interesting behaviors have been observed, including frequency excursion propagation. We address the consistency of a frequency excursion detection order of frequency disturbance recorders in FNET in relation to the same generation trip, as well as the ability to recreate by power systems dynamic simulation. We also propose a new method, as an application of FNET measurement, to locate a tripped generator using power systems dynamic simulation and wide-area frequency measurement. The simulation database of all the possible trips of generators in the interconnected power systems is created using the off-line power systems dynamic simulation. When FNET detects a sudden drop in the monitoring frequency, which is most likely due to a generation trip in power systems, the proposed algorithm locates a tripped generator by finding the best matching case of the measured frequency excursion in the simulation database in terms of the frequency drop detection order and the time of monitoring points.

High-Efficiency DC-DC Converter with Improved Dynamic Response Characteristics for Modular Photovoltaic Power Conversion (모듈형 태양광 발전을 위한 개선된 동적응답 특성을 지닌 고효율 DC-DC 컨버터)

  • Choi, Jae-Yeon;Choi, Woo-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.54-62
    • /
    • 2013
  • This paper proposes a high-efficiency DC-DC converter with improved dynamic response characteristics for modular photovoltaic power conversion. High power efficiency is achieved by reducing switching power losses of the DC-DC converter. The voltage stress of power switches is reduced at primary side. Zero-current switching of output diodes is achieved at secondary side. A modified proportional and integral controller is suggested to improve the dynamic responses of the DC-DC converter. The performance of the proposed converter is verified based on a 200 [W] modular power conversion system including the grid-tied DC-AC inverter. The proposed DC-DC converter achieves the efficiency of 97.9 % at 60 [V] input voltage for a 200 [W] output power. The overall system including DC-DC converter and DC-AC inverter achieves the efficiency of 93.0 % when 200 [W] power is supplied into the grid.

Dynamic Coordination Strategies between HVDC and STATCOM

  • Kim, Chan-Ki;Sood, Vijay;Lee, Seok-Jin
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.892-902
    • /
    • 2009
  • This paper deals with the dynamic voltage control problem at the inverter end of a HVDC link when connected to a weak AC system which has the potential for harmonic instability and commutation failures. The dynamic voltage control problem is tackled with a STATCOM (Static Compensator), which not only provides a rapid recovery from harmonic instability and commutation failures but also offers a lower cost filter design for HVDC systems. PSCAD/EMTDC simulations are presented to validate the proposed topology and to demonstrate its robust performance.

Dynamic Analysis of Doubly-Fed Induction Generators for Wind Power Applications (이중여자 권선형 유도 발전기에 의한 풍력발전시스템의 동특성 해석)

  • Jang, Seok-Myeong;Choi, Jang-Young;Cho, Han-Wook;Park, Ji-Hoon;Yoon, Ki-Kab
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1183-1184
    • /
    • 2006
  • Using the MATLAB/SIMULINK, this paper presents dynamic simulation model for 6MW wind power generation systems with the DFIG considering distribution systems and performs the dynamic analysis of wind power systems

  • PDF

Optimal Design for Dynamic Resistance Equalization Technique to Minimize Power Loss and Equalization Error

  • La, Phuong-Ha;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.50-52
    • /
    • 2019
  • Dynamic resistance equalization is a viable technique to balance SOC of cells in a parallel-connected battery configuration due to high equalization performance, simplicity and low-cost. However, an inappropriate design of the equalization resistor can degrade the equalization performance and increase the power loss. This paper proposes an optimization process to design the equalization resistors to minimize power loss and equalization error. The simulation results show that the optimally designed resistor significantly enhance the performance in comparison with the conventional fixed-resistor equalization.

  • PDF

Design and Scrutiny of Maiden PSS for Alleviation of Power System Oscillations Using RCGA and PSO Techniques

  • Falehi, Ali Darvish
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.402-410
    • /
    • 2013
  • In this paper, a novel and robust Power System Stabilizer (PSS) is proposed as an effective approach to improve stability in electric power systems. The dynamic performance of proposed PSS has been thoroughly compared with Conventional PSS (CPSS). Both the Real Coded Genetic Algorithm (RCGA) and Particle Swarm Optimization (PSO) techniques are applied to optimum tune the parameter of both the proposed PSS and CPSS in order to damp-out power system oscillations. Due to the high sufficiency of both the RCGA and PSO techniques to solve the very non-linear objective, they have been employed for solution of the optimization problem. In order to verify the dynamic performance of these devices, different conditions of disturbance are taken into account in Single Machine Infinite Bus (SMIB) power system. Moreover, to ensure the robustness of proposed PSS in damping the power system multi-mode oscillations, a Multi Machine (MM) power system under various disturbances are considered as a test system. The results of nonlinear simulation strongly suggest that the proposed PSS significantly enhances the power system dynamic stability in both of the SMIB and MM power system as compared to CPSS.

Power Management for Mobile Terminal (모바일 단말에서의 전원관리 기술)

  • Lee, Junghee;Park, Hojun;Kim, Jaemyoung
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.2 no.3
    • /
    • pp.194-201
    • /
    • 2007
  • As the performance of the mobile terminal becomes higher, the power consumption gradually increases. As a result, power management is one of the most important issues in mobile system with battery. In this paper, we describe an DPM(Dynamic Power Management) using DVS(Dynamic Power Management) as a power management mechanism in Qplus operating system. DVS generally considers a specific device such as CPU, whereas we consider the relations with other hardware components as well as each component. We specially focus on the relation between CPU, memory and LCD devices. We also designs a kernel monitor to collect information to decide the policy for power management. According to the experimental results, the proposed method enables to save much power.

  • PDF

Visualization of Dynamic Simulation Data for Power System Stability Assessment

  • Song, Chong-Suk;Jang, Gil-Soo;Park, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.484-492
    • /
    • 2011
  • Power system analyses, which involve the handling of massive data volumes, necessitate the use of effective visualization methods to facilitate analysis and assist the user in obtaining a clear understanding of the present state of the system. This paper introduces an interface that compensates for the limitations of the visualization modules of dynamic security assessment tools, such as PSS/e and TSAT, for power system variables including generator rotor angle and frequency. The compensation is made possible through the automatic provision of dynamic simulation data in visualized and tabular form for better data intuition, thereby considerably reducing the redundant manual operation and time required for data analysis. The interface also determines whether the generators are stable through a generator instability algorithm that scans simulation data and checks for an increase in swing or divergence. The proposed visualization methods are applied to the dynamic simulation results for contingencies in the Korean Electric Power Corporation system, and have been tested by power system researchers to verify the effectiveness of the data visualization interface.

Performance Improvement of Air Conditioner Network System using Wireless Sensors Through System Performance Index and Dynamic Power Distribution Control (시스템 성능 지수 및 동적 전력분산 제어를 통한 무선센서를 이용한 에어컨 네트워크 시스템의 성능 개선)

  • Choi, Ho-seek;Kwon, Woo-hyen;Yoon, Byung-keun
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.64-70
    • /
    • 2019
  • Wireless sensors have been developed in numerous ways for enhancing the convenience of installation, management and maintenance of sensors. Energy harvesting wireless sensors, which can collect energy from the external environment for permanent usage without the need of recharging and exchanging batteries, have been developed and employed used in Internet of Things and at various industrial sites. Energy harvesting wireless sensors are significantly affected by the sensor lifespan to sudden variation in the external environment. Furthermore, reduction in the sensor operating timespan can greatly affect the characteristics of the devices connected through a network. In this paper, a system performance index is proposed that can comprehensively evaluate the lifespan of a solar cell wireless sensor, determine the characteristics of devices connected to the associated network, and recommend dynamic power distribution control for improving the system performance index. Improvement in the system performance index was verified by applying the proposed dynamic power distribution control to an air conditioner network system using a solar cell wireless sensor. Obtained results corroborate that the dynamic power distribution control can extend the lifespan of the incorporated wireless sensor and reduce the air conditioner's power consumption.

Development of Composite Load Models of Power Systems using On-line Measurement Data

  • Choi Byoung-Kon;Chiang Hsiao Dong;Li Yinhong;Chen Yung Tien;Huang Der Hua;Lauby Mark G.
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.161-169
    • /
    • 2006
  • Load representation has a significant impact on power system analysis and control results. In this paper, composite load models are developed based on on-line measurement data from a practical power system. Three types of static-dynamic load models are derived: general ZIP-induction motor model, Exponential-induction motor model and Z-induction motor model. For the dynamic induction motor model, two different third-order induction motor models are studied. The performances in modeling real and reactive power behaviors by composite load models are compared with other dynamic load models in terms of relative mismatch error. In addition, numerical consideration of ill-conditioned parameters is addressed based on trajectory sensitivity. Numerical studies indicate that the developed composite load models can accurately capture the dynamic behaviors of loads during disturbance.