• Title/Summary/Keyword: dynamic modal analysis

Search Result 933, Processing Time 0.029 seconds

Moving Load Analysis of Bridge Structures Using Experimental Modal Data (실험적 모우드 계수를 이용한 교량의 주행하중 해석)

  • 이형진
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.3
    • /
    • pp.409-420
    • /
    • 2002
  • This paper proposed a technique of structural re-analysis for the evaluation of dynamic responses of bridge structure under moving loads using experimental modal results. For successful structural re-analysis, it is required to have accurate estimation techniques of the modal characteristics of bridge structures. The natural frequencies and mode shapes were identified by direct fourier analysis techniques and damping ratios by the random decrement method, respectively. An interpolation method was also proposed for the extension of mode shape measured on limited DOFs. Second, the structural reanalysis was performed using moving mass model and identified modal parameters. The results from the reanalysis show that the proposed technique is very reasonable to evaluate the actual behavior of bridge structures under moving loads.

Development of a GUI Program for the Design of a Vibration Control Boring Bar with a Tube-Type Structure (튜브 타입 제진용 보링바 구조설계를 위한 GUI 프로그램 개발)

  • Guo, Yang-Yang;Park, Jong-Kweon;Hong, Jun-Hee;Song, Doo-Sang
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.4
    • /
    • pp.295-300
    • /
    • 2016
  • In the design of passive and active boring bars, the structural dimensions and shape of the vibration control boring bar are modified depending on the diameter and depth of the workpiece, which changes the dynamic behavior. Thus, the natural frequency, effective mass, and stiffness for the main structure of a tube-type boring bar need to be reset for each vibration control case. However, commercial finite element method (FEM) software and experimental modal analysis are mostly used at present despite being too time-consuming. To overcome the weaknesses of the two methods currently used for vibration control, we realized a graphical user interface (GUI) program for the modal analysis of a modified tube-type damping structure. The analysis results with the GUI program were compared to those with commercial FEM software in order to confirm the effectiveness of the former.

Dynamic Modeling and Analysis of the Washing Machine System with an Automatic Balancer (자동 밸런서를 갖는 세탁기 시스템의 동력학 모델링 및 해석)

  • Oh, Hyuck-Jin;Lee, U-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.8 s.227
    • /
    • pp.1212-1220
    • /
    • 2004
  • The structural unbalance mass and laundry are the important sources of the severe vibrations of automatic washing machines. In this paper, a mathematical model is developed for the dynamic analysis of the vertical axis automatic washing machines of pulsator-type. In the model, the rigid body motion of tub assembly is represented by six degrees of freedom and the dynamics of automatic hydraulic balancer is represented by one degree of freedom. The fundamental elastic modes of the tub shell and four suspension bars are also taken into account in the mathematical model, based on analytical and experimental modal analysis results. The 12 degrees of freedom equations of motion are derived by using the Lagrange's equations and the present dynamic model is evaluated by comparing the numerical simulation results with experimentally measured data.

The Development of Evaluation Process for Dynamic Characteristics of Door Module (자동차용 모듈화 도어의 동특성 평가 시험법 개발)

  • Bae, Chul-Yong;Kim, Chan-Jung;Kwon, Seong-Jin;Lee, Bong-Hyun;Jang, Woon-Sung;Lee, Joon-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.291-296
    • /
    • 2007
  • This study presents the evaluation process for door module. Its objective evades the resonance generated at module plate due to the operation of window regulator motor. For this study, the design improvement process is composed of experimental methods having three steps. First step is modal analysis at door assembly status for acquisition of dynamic characteristics which are modal frequency and damping. Second step is a vibration experiment to get the test mode considered an efficiency of window regulator motor. Last step is a vibration measurement by the form of $6{\times}6$ array on module plate. A vibration measurement of 6x6 array form can be got to three analysis results which are a transfer path of vibration using cross correlation function, a vibration map using OA level and a contribution by frequency band using coherent output power spectrum on module plate. These results are applied to SDM(structural dynamic modification) for design improvement to get around the resonance on module plate by the excitation of window regulator motor.

  • PDF

Study on the Noise Reduction in the Rotary Compressor Using BLDC Motor (BLDC 모터를 적용한 로터리 컴프레서 소음 저감에 관한 연구)

  • Kim, Jin-Soo;Lim, Kyung-Nae;Ku, Se-Jin;Lee, Jang-Woo;Jeon, Si-Moon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.920-929
    • /
    • 2008
  • The main noise and vibration source of the BLDC rotary compressor for air conditioner was analyzed by using the measurement of noise and vibration, noise contour, and experimental modal analysis. The source is presumed to the mechanical resonance excited by the electromagnetic attractive force of the BLDC motor. To reduce the excessive noise of the BLDC rotary compressor due to the mechanical resonance, air-gap enlargement and structural dynamic modification were applied in this paper. Its validations were conducted by the analysis of the electromagnetic attractive force which is generated by the BLDC motor and by the measurement of noise and vibration of the BLDC rotary compressor. By enlarging the length of air-gap and conducting the structural dynamic modification, the noise and vibration in the compressor was significantly improved by 4.5 dB(A) and 56 percent, respectively.

A Study on the Dynamic Characteristics of Door Module for Vehicle (자동차용 모듈화 도어의 동특성 분석에 관한 연구)

  • Bae, Chul-Yong;Kim, Chan-Jung;Kwon, Seong-Jin;Lee, Bong-Hyun;Jang, Woon-Sung;Lee, Joon-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1093-1101
    • /
    • 2007
  • This study presents the design improvement process for door module. Its objective evades the resonance generated at module plate due to the operation of window regulator motor. For this study, the design improvement process is composed of experimental methods having three steps. First step is modal analysis at door assembly status for acquisition of dynamic characteristics which are modal frequency and damping. Second step is a vibration experiment to get the test mode considered an efficiency of window regulator motor. Last step is a vibration measurement by the form of $6{\times}6$ array on module plate. A vibration measurement of $6{\times}6$ array form can be got to three analysis results which are a transfer path of vibration using cross correlation function, a vibration map using OA level and a contribution by frequency band using coherent output power spectrum on module plate. These results are applied to SDM(structural dynamic modification) for design improvement to get around the resonance on module plate by the excitation of window regulator motor.

Investigating the effect of edge crack on the modal properties of composite wing using dynamic stiffness matrix

  • Torabi, Ali Reza;Shams, Shahrokh;Fatehi-Narab, Mahdi
    • Steel and Composite Structures
    • /
    • v.39 no.5
    • /
    • pp.543-564
    • /
    • 2021
  • In this study free vibration analysis of a cracked Goland composite wing is investigated. The wing is modelled as a cantilevered beam based on Euler- Bernoulli equations. Also, composite material is modelled based on lamina fiber-reinforced. Edge crack is modelled by additional boundary conditions and local flexibility matrix in crack location, Castigliano's theorem and energy release rate formulation. Governing differential equations are extracted by Hamilton's principle. Using the separation of variables method, general solution in the normalized form for bending and torsion deflection is achieved then expressions for the cross-sectional rotation, the bending moment, the shear force and the torsional moment for the cantilevered beam are obtained. The cracked beam is modelled by separation of beam into two interconnected intact beams. Free vibration analysis of the beam is performed by applying boundary conditions at the fixed end, the free end, continuity conditions in the crack location of the beam and dynamic stiffness matrix determinant. Also, the effects of various parameters such as length and location of crack and fiber angle on natural frequencies and mode shapes are studied. Modal analysis results illustrate that natural frequencies and mode shapes are affected by depth and location of edge crack and coupling parameter.

Structural evaluation of an existing steel natatorium by FEM and dynamic measurement

  • Liu, Wei;Gao, Wei-Cheng;Sun, Yi;Yu, Yan-Lei
    • Structural Engineering and Mechanics
    • /
    • v.31 no.5
    • /
    • pp.507-526
    • /
    • 2009
  • Based on numerical and experimental methods, a systematic structural evaluation of a steel natatorium in service was carried out in detail in this paper. Planning of inspection tasks was proposed firstly according to some national codes in China in order to obtain the economic and reliable results. The field visual inspections and static computation were conducted in turn under in-service environmental conditions. Further a three-dimensional finite element model was developed according to its factual geometry properties obtained from the field inspection. An analytical modal analysis was performed to provide the analytical modal properties. The field vibration tests on the natatorium were conducted and then two different system identification methods were used to obtain the dynamic characteristics of the natatorium. A good correlation was achieved in results obtained from the two system identification methods and the finite element method (FEM). The numerical and experimental results demonstrated that the main structure of the natatorium in its present status is safe and it still satisfies the demand of the national codes in China. But the roof system such as purlines and skeletons must be removed and rebuilt completely. Moreover the system identification results showed that field vibration test is sufficient to identify the reliable dynamic properties of the natatorium. The constructive suggestion on structural evaluation of the natatorium is that periodic assessment work must be maintained to ensure the natatorium's safety in the future.

The Grid Strap Vibration Characteristics of the 5×5 Nuclear Fuel Mock-up (5×5 핵연료 모의 집합체의 지지격자 스트랩 진동특성)

  • Kim, Kyoung-Hong;Park, Nam-Gyu;Kim, Kyoung-Ju;Suh, Jung-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.7
    • /
    • pp.619-625
    • /
    • 2012
  • Since the fuel is always exposed to turbulent flow, the grid strap shows flow induced vibration characteristics that impact on the nuclear fuel soundness. The dynamic behavior of grids in nuclear fuels is quite complex, since two pairs of spring and dimple support are contacted with rods by friction in the limited space. This paper focuses on investigation of the grid strap(test fuel strap, TFS) vibration in one cell. TFS consists of a single spring and double dimples. To identify the grid strap vibration, modal analysis of the strap is performed using finite element method(FEM). Modal testing on a $5{\times}5$ grid structure without rods is performed. The modal testing results are compared to analytic results. In addition, random test considering rod effect is performed about a $5{\times}5$ grid with rods under real contact condition in the air. Finally, the strap vibration of a $5{\times}5$ fuel bundle in investigation of flow induced vibration(INFINIT) facility is measured in real fluid velocity condition without heating. It is shown that modal frequencies from the test are almost equal to those peak frequencies in the INFINIT test.