• Title/Summary/Keyword: dynamic material properties

Search Result 834, Processing Time 0.028 seconds

Design and Fabrication of Split Hopkinson Pressure Bar for Acquisition of Dynamic Material Property of Al6061-T6 (Al6061-T6 의 동적 물성 획득을 위한 Split Hopkinson Pressure Bar의 설계 및 제작)

  • An, Woo Jin;Woo, Min A;Noh, Hak Gon;Kang, Beom Soo;Kim, Jeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.587-594
    • /
    • 2016
  • The Split Hopkinson pressure bar (SHPB) test method, which is composed of three cylindrical bars, measuring devices and frames, is known for its reliable technique of acquiring the mechanical properties of specimens under a high strain rate. This paper demonstrates the processing of design and fabrication of SHPB. First of all, numerical analysis is applied in order to determine the design parameters of SHPB apparatus and verify the validity of design for a SHPB facility. Following this, SHPB apparatus were fabricated in accordance with acquired design parameters by simulation. In order to verify the validity of SHPB apparatus, experimental results using Al6061-T6 were compared with numerical data obtained from a corresponding simulation. The result of this comparative study demonstrates the applicability and validity of the fabricated apparatus.

Effect of porosity on frost resistance of Portland cement pervious concrete

  • Zhang, Wuman;Li, Honghe;Zhang, Yingchen
    • Advances in concrete construction
    • /
    • v.6 no.4
    • /
    • pp.363-373
    • /
    • 2018
  • Portland cement pervious concrete (PCPC) is an effective pavement material to solve or reduce the urban waterlogging problems. The Mechanical properties, the permeability, the abrasion resistance and the frost resistance of PCPC without fine aggregate were investigated. The increase of porosity was achieved by fixing the dosage of coarse aggregate and reducing the amount of cement paste. The results show that the compressive strength and the flexural strength of PCPC decrease with the increase of porosity. The permeability coefficient and the wear loss of PCPC increase with the increase of the porosity. The compressive strength and the flexural strength of PCPC subjected to 25 freeze-thaw cycles are reduced by 13.7%-17.8% and 10.6%-18.3%, respectively. For PCPC subjected to the same freeze-thaw cycles, the mass loss firstly increases and then decreases with the increase of the porosity. The relative dynamic modulus elasticity decreases with the increase of freeze-thaw cycles. And the lower the PCPC porosity is, the more obvious the dynamic modulus elasticity decreases.

Effect of Starch and Base Paper Properties an Adhesion Problem of Corrugated Board (골판지 접착 불량에 대한 전분과 원지 특성의 영향)

  • Lee, Jin-Ho;Park, Jong-Moon;Lee, Sang-Hyun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.2 s.115
    • /
    • pp.43-51
    • /
    • 2006
  • Starch is widely used as an adhesive material in the paper and corrugated board industry. The adhesion problem of corrugated board is categorized by two main parts called zipper board and white glue line. The object of this research is to investigate the factors affecting the adhesion problem by the gelatinization of various starch solutions and dynamic penetration properties measurements of various commercial base paper and handsheets. Flow property of starch solution is affected by sodium hydroxide addition and reaction level. Absorption property of commercial base papers and handsheets is affected by sizing and stock composition. Optimum bonding between top/bottom liners and corrugated medium is accomplished by acceptable flow viscosity of mixed starch solution and proper adsorption characteristic of base paper.

Transient analysis of two dissimilar FGM layers with multiple interface cracks

  • Fallahnejad, Mehrdad;Bagheri, Rasul;Noroozi, Masoud
    • Structural Engineering and Mechanics
    • /
    • v.67 no.3
    • /
    • pp.277-281
    • /
    • 2018
  • The analytical solution of two functionally graded layers with Volterra type screw dislocation is investigated under anti-plane shear impact loading. The energy dissipation of FGM layers is modeled by viscous damping and the properties of the materials are assumed to change exponentially along the thickness of the layers. In this study, the rate of gradual change ofshear moduli, mass density and damping constant are assumed to be same. At first, the stress fields in the interface of the FGM layers are derived by using a single dislocation. Then, by determining a distributed dislocation density on the crack surface and by using the Fourier and Laplace integral transforms, the problem are reduce to a system ofsingular integral equations with simple Cauchy kernel. The dynamic stress intensity factors are determined by numerical Laplace inversion and the distributed dislocation technique. Finally, various examples are provided to investigate the effects of the geometrical parameters, material properties, viscous damping and cracks configuration on the dynamic fracture behavior of the interacting cracks.

Strength Properties of Recycled Concrete Containing Water-redispersible Copolymer Powder (재유화형분말수지를 혼입한 재생콘크리트의 강도 특성)

  • Kim, In-Su;Sung, Chan-Yong
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.128-134
    • /
    • 2005
  • This study was performed to evaluate the strength and durability properties of recycled concrete containing water - redispersible copolymer powder(WRP) and blast furnace slag powder(BSP) [RCWS]. Material used were cemente, recycled coarse aggregare, natural fine aggregate, water-redispersible copolymer powder, blast-furnace slag powder. Especially, Water-redispersible powder was used for blending with Inorganic binders such as cemente, gypsum and hydrated lime etc. First of all, Mixed ratio method of RCWS made Two Type. One was called type-1 which used to BSP content 5% and WRP(Water-redispersible powder) content 0%, 1%, 2%, 3%, 4%, 5%, 6%. respectively. Another was called Type-2 which used to BSP(blast furnace slag powder)content 10% and WRP(Water-redispersible powder) content 0%, 1%, 2%, 3%, 4%, 5%, 6%. respectively. According to the experimental results of (RCWS), Incase Type-2 at curing age 28days, Compressive strength, pulse velocity and dynamic modulous of elasticity were shown higher than Type-1 and The more WRP content increasing($0%{\sim}6%$) was the lower Compressive strength, Pulse velocity and Dynamic modulous of elasticity. Water absorption ratio was in the range of $3.85%\;{\sim}\;3.23%$, it was almost equal to Type-1, 2 but Increasing the WRP content($0%{\sim}6%$), The water absorption ratio is decreased.

  • PDF

Vibration based damage identification of concrete arch dams by finite element model updating

  • Turker, Temel;Bayraktar, Alemdar;Sevim, Baris
    • Computers and Concrete
    • /
    • v.13 no.2
    • /
    • pp.209-220
    • /
    • 2014
  • Vibration based damage detection is very popular in the civil engineering area. Especially, special structures like dams, long-span bridges and high-rise buildings, need continues monitoring in terms of mechanical properties of material, static and dynamic behavior. It has been stated in the International Commission on Large Dams that more than half of the large concrete dams were constructed more than 50 years ago and the old dams have subjected to repeating loads such as earthquake, overflow, blast, etc.,. So, some unexpected failures may occur and catastrophic damages may be taken place because of theloss of strength, stiffness and other physical properties of concrete. Therefore, these dams need repairs provided with global damage evaluation in order to preserve structural integrity. The paper aims to show the effectiveness of the model updating method for global damage detection on a laboratory arch dam model. Ambient vibration test is used in order to determine the experimental dynamic characteristics. The initial finite element model is updated according to the experimentally determined natural frequencies and mode shapes. The web thickness is selected as updating parameter in the damage evaluation. It is observed from the study that the damage case is revealed with high accuracy and a good match is attained between the estimated and the real damage cases by model updating method.

Experimental Study on Vibration Reduction Characteristics of Polymer Concrete (폴리머 콘크리트의 진동저감 특성에 대한 실험적 연구)

  • Kim, Jeong-Jin;Shim, Hak-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.58-65
    • /
    • 2019
  • Polymer concrete is expected to be widely used as a building material because it has a shorter hardening time and excellent compression, tensile, bending, bond strength, frictional resistance and abrasion loss compared to general concrete. The polymer concrete has excellent vibration damping performance and research on the use of various reinforcing materials is being conducted. However, in order to completely replace the general concrete and the general anti-vibration reinforcement, such polymer concrete requires an overall review of vibration reduction performance considering physical properties, dynamic properties, productivity and field applicability. In this study, the physical and dynamic properties of polymer concrete by epoxy mixing ratio were compared with those of general concrete. It was appeared that compression, tensile, bending and bond strengths of polymer concrete by epoxy mixing were significantly higher than those of general concrete. Especially, the tensile strength was more than 4 ~ 6.5 times. Based on the basic physical properties of polymer concrete, the damping ratio, which is a dynamic characteristic according to the epoxy mixing ratio, was derived through analytical models and experiments. As a result, the dynamic stiffness of polymer concrete was 20% higher than that of general concrete and the loss rate was about 3 times higher.

The Influence of Magnetic Particle Size and Its Properties on The Electromagnetic Particle in Magnetic Tape (자기 Tape의 전자 변환 특성에 대한 자성분의 Size와 그 특성의 영향)

  • 김상문;김태옥
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.5
    • /
    • pp.334-339
    • /
    • 1996
  • In order to investigate the influence of the magnetic paticle size and its properties on the particulate magnetic material, we evaluated the dispersion of magnetic particles and the electromagnetic properties in magnetic tape made from the magnetic paints by use of each magnetic particles witch were different from particle size and its propertis. The dispersion of magnetic particles depends on the surface chemical properties rather than particle size. As particle size is smaller, the packing ratio of magnetic particle and the magnetic flux density in tape increase. The output levels in playing back of tape incerase in wide frequency range from 315 Hz to 10 kHz and the noises decrease. It is very important to choose the size, the shape, the surface chemical properties and the magnetic properties of the magnetic particle in producing the high quality magnetic tape.

  • PDF

Shear modulus and stiffness of brickwork masonry: An experimental perspective

  • Bosiljkov, Vlatko Z.;Totoev, Yuri Z.;Nichols, John M.
    • Structural Engineering and Mechanics
    • /
    • v.20 no.1
    • /
    • pp.21-43
    • /
    • 2005
  • Masonry is a composite non-homogeneous structural material, whose mechanical properties depend on the properties of and the interaction between the composite components - brick and mortar, their volume ratio, the properties of their bond, and any cracking in the masonry. The mechanical properties of masonry depend on the orientation of the bed joints and the stress state of the joints, and so the values of the shear modulus, as well as the stiffness of masonry structural elements can depend on various factors. An extensive testing programme in several countries addresses the problem of measurement of the stiffness properties of masonry. These testing programs have provided sufficient data to permit a review of the influence of different testing techniques (mono and bi-axial tests), the variations caused by distinct loading conditions (monotonic and cyclic), the impact of the mortar type, as well as influence of the reinforcement. This review considers the impact of the measurement devices used for determining the shear modulus and stiffness of walls on the results. The results clearly indicate a need to re-assess the values stated in almost all national codes for the shear modulus of the masonry, especially for masonry made with lime mortar, where strong anisotropic behaviour is in the stiffness properties.

Comparing and Consideration of Static and Dynamic Stability Analysis Methods for Domestic Reservoirs (국내 저수지에 대한 정역학적 및 동역학적 안정해석방법의 비교 및 고찰)

  • Lee, Moojae;Kim, Yongseong;Heo, Joon;Bark, Minwoo;Bibek, Tamang;An, Sungsoo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.5
    • /
    • pp.73-84
    • /
    • 2020
  • In this study, we compared and analyzed the static and dynamic analysis method for agricultural reservoirs. In addition, we assumed the aging of reservoir as the deterioration of the internal friction angle and cohesion. The internal friction angle and cohesion were applied by dividing into 4 case for each reservoir. As a result of comparing the stability of the reservoir embankment, it was found that the dynamic stability analysis method showed a greater risk than the static stability analysis method when dynamic loads such as earthquakes were applied. Therefore, when detailed review such as liquefaction is required, it is considered that the dynamic stability analysis method should be applied first. If a study on the change in material properties due to the aging of the reservoir is conducted, the stability analysis of the reservoir due to the aging of the reservoir can be performed more accurately. In addition, if a study comparing the results of dynamic stability analysis and static stability analysis for earthquakes with various characteristics for more reservoirs is conducted, detailed criteria for the case where dynamic stability analysis should be considered can be presented.