• Title/Summary/Keyword: dynamic jaw

Search Result 28, Processing Time 0.023 seconds

Dynamic Walking Control of Biped Walking Robot using Intelligent Control Method and Sensor Interface (지능형 제어기법 및 센서 인터페이스를 이용한 이족 보행 로봇의 동적보행 제어)

  • Kho, Jaw-Won;Lim, Dong-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.161-167
    • /
    • 2007
  • This paper introduces a dynamic walking control of biped walking robot using intelligent sensor interface and shows an intelligent control method for biped walking robot. For the dynamic walking control of biped walking robot, serious motion controllers are used. They are main controller(using INTEL80C296SA MPU), sub controller(using TMS320LF2406 DSP), sensor controller(using Atmega128 MPU) etc. The used sensors are gyro sensor, tilt sensor, infrared sensor, FSR sensor etc. For the feasibility of a dynamic walking control of biped walking robot, we use the biped walking robot which has twenty-five degrees of freedom(D.O.F.) in total. Our biped robot is composed of two legs of six D.O.F. each, two arms of five D.O.F. each, a waist of two D.O.F., a head of one D.O.F.

Implementation and Performance Evaluation of RTOS-Based Dynamic Controller for Robot Manipulator (Real-Time OS 기반의 로봇 매니퓰레이터 동력학 제어기의 구현 및 성능평가)

  • Kho, Jaw-Won;Lim, Dong-Cheal
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.109-114
    • /
    • 2008
  • In this paper, a dynamic learning controller for robot manipulator is implemented using real-time operating system with capabilities of multitasking, intertask communication and synchronization, event-driven, priority-driven scheduling, real-time clock control, etc. The controller hardware system with VME bus and related devices is developed and applied to implement a dynamic learning control scheme for robot manipulator. Real-time performance of the proposed dynamic learning controller is tested and evaluated for tracking of the desired trajectory and compared with the conventional servo controller.

Quality Assurance of Operation of Enhanced Dynamic Wedges in Linac (선형가속기의 동적쐐기(EDW) 작동에 대한 품질보증)

  • Jeong, Dong-Hyeok;Kim, Jhin-Kee;Kang, Jeong-Ku;Son, Kwang-Jae;Lee, Jeong-Ok
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.133-141
    • /
    • 2010
  • The evaluation of Varian enhanced dynamic wedges (EDW) were performed in terms of quality assurance in external radiotherapy. The seven (10, 15, 20, 25, 30, 45, 60 deg.) EDW angles were evaluated for 6 and 15 MV x-rays in Varian Linac. The STT (segmented treatment table) for a field were calculated and compared with actual movement of the jaw using Dynalog files in order to evaluate mechanical operation. Two dimensional array detector and an ionization chamber were used to measure dose distributions in phantom from Linac. The mechanical movement of jaw was agreed with its expectation and two dimensional dose distributions including beam profiles were in agreement with RTP data approximately. In comparison with RTP calculations the percentage difference of output dose values for 100 MU irradiation was less than 2.9% and measured wedge factor was less than 2.6%. These results are shown that there is no problem in clinical applications of EDW equipped on this linac.

Using dental virtual patients with dynamic occlusion in esthetic restoration of anterior teeth: case reports (동적 교합을 나타내는 가상 환자의 형성을 통한 심미적인 전치부 보철 수복 증례)

  • Phil-Joon Koo;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.328-343
    • /
    • 2023
  • Recently, a method of fabricating an esthetic anterior fixed prosthesis by integrating data such as three-dimensional facial scan and jaw motion to form a virtual patient with dynamic occlusion has been introduced. This enables smooth communication with patients during the diagnosis process, improves the predictability of esthetic prosthetic treatment, and lowers the possibility of occlusal adjustment. In this case report, a virtual patient with dynamic occlusion was created in which the results of the treatment were simulated, and esthetic maxillary anterior fixed prosthesis was fabricated. With the aid of the virtual patient, the final restorations were satisfactory both in terms of esthetic and function.

A Study on the Dynamic Characteristics of the Coil Forming Machine for AC Motor (AC모터 코일포밍머신의 동특성에 대한 연구)

  • Jeong, Sang-Hwa;Song, Suk;Choi, Seok-Hwan
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.159-163
    • /
    • 2003
  • In recent days, as the efficiency of electronic home applications become higher, that of the driving AC motor become higher. On this reason, the demand fir high capacity coil firming machine is increasing. Since the coil forming is not simply related with the only capacity of hydraulic cylinder, the development of a newer coil firming machine which has new filming mechanism new driving method, new filming tool, and new specification is required. In this paper, the virtual prototype which have new mechanism is developed. This prototype is tested and experimented on PC with the same condition as actual. The results from the virtual experiment is applied to the actual design process.

  • PDF

Application and usefulness of Ultrasound sonography in dentistry (영상치의학에서 초음파영상의 진단과유용성)

  • Choi, Yong Suk;Seo, Yoo Kyung;Kang, Ju Hee;Oh, Song Hee;Kim, Gyu Tae;Hwang, Eui Hwan
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.778-788
    • /
    • 2017
  • Ultrasound sonography(US) is used to evaluate various diseases of oral and maxillofacial region including salivary glands, soft tissue and jaw lesions because of easy accessibility and no hazard of ionizing radiation. Also, US can offer dynamic study showing real-time images during diagnostic or surgical procedure. US images provide accurate information about the internal features of lesions on the jaw prior to surgical treatment. Doppler images are used to visualize the vascular distribution of the lesions and to provide additional information to enhance diagnostic value. It is necessary to evaluate the diagnostic value of US and evaluate its usefulness by looking at clinical cases using US images. Therefore, US imaging may be recommended as an assistant image in evaluating jaw lesions. US images provided accurate information about the internal structure of lesions on the jaw prior to surgical treatment, and diagnostic value was enhanced by visualizing the vascular distribution of the lesion using doppler imaging. We report the protocol and suggest the effectiveness of US for various lesions and US-guided sialography.

  • PDF

Correlations of temporomandibular joint morphology and position using cone-beam computed tomography and dynamic functional analysis in orthodontic patients: A cross-sectional study

  • Bin Xu;Jung-Jin Park;Seong-Hun Kim
    • The korean journal of orthodontics
    • /
    • v.54 no.5
    • /
    • pp.325-341
    • /
    • 2024
  • Objective: To correlate temporomandibular joint (TMJ) morphology and position with cone-beam computed tomography (CBCT) images, Joint Vibration Analysis (JVA), and Jaw Tracker (JT) to develop a radiation-free, dynamic method for screening and monitoring the TMJ in orthodontic patients. Methods: A total of 236 orthodontic patients without symptoms of TMJ disorders who had undergone CBCT were selected for the JVA and JT tests in this cross-sectional study. TMJ position and morphology were measured using a three-dimensional analysis software. JT measurements involved six opening-closing cycles, and JVA measurements were performed using a metronome to guide the mouth opening-closing movements of the patients. The correlations among the three measuring devices were evaluated. Results: Abnormalities in condylar surface morphology affected the mandibular range of motion. The cut-off value results show that when various measurement groups are within a certain range, abnormalities may be observed in morphology (area under the curve, 0.81; P < 0.001). A 300/< 300 Hz ratio ≥ 0.09 suggested abnormal morphology (P < 0.05). Correlations were observed among the maximum opening velocity, maximum vertical opening position, and joint spaces in the JT measurements. Correlations were also observed between the > 300/< 300 Hz ratio, median frequency, total integral, integral < 300 Hz, and peak frequency with joint spaces in the JVA measurements. Conclusions: JT and JVA may serve as rapid, non-invasive, and radiation-free dynamic diagnostic tools for monitoring and screening TMJ abnormalities before and during orthodontic treatment.

A Study on the Performance of Dynamic Restraint Manipulator for Drilling Alveolar Bone in Mandible (하악골의 치조골 골삭제를 위한 동적 제약 기구부의 성능에 관한 연구)

  • Kim, Gwang-Ho;Lee, Dong-Woon;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.105-112
    • /
    • 2020
  • The increase in the edentulous jaw which occurs in the aged population has led to personal dental health concerns. In the case of dental implant surgery, the duration of a patient's recovery depends on the surgical plan and their physicical ability. A device may be required to assist a physician in controlling vibration reduction of free-hand drilling and prescribing a good treatment plan that is suitable for the patient's condition. In this work, an artificial tooth-root implant assistant manipulator was studied. The structure and the vibration analysis of the dynamic restraint manipulator that is for drilling the alveolar bone in the mandible bone were performed, and the structural stability was analyzed. Further, a virtual prototype of an artificial tooth-root implant assisted manipulator was fabricated and tested. Hence, the state of the Remote Center of Motion (RCM) point and the driving state of the manipulator were confirmed. Furthermore, the drilling experiments were performed by using materials similar to a human jawbone in order to evaluate the performance of the drilling process that is operated using the assistant manipulator.

Application of Systematic Digital Diagnosis to Create Dental Virtual Patients with Dynamic Occlusion for Esthetic Restoration of Anterior Teeth: A Case Report

  • Jeong-Min Ham;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • Journal of Korean Dental Science
    • /
    • v.17 no.3
    • /
    • pp.121-137
    • /
    • 2024
  • It is possible to design dental prosthesis in harmony with the patient's face and functional pathway using virtual patient created by integrating 3D diagnostic data such as intraoral scan, facial scan and jaw motion data. Also, esthetic teeth-gingiva relationship can be obtained, and post-surgical gingival outline can be predicted by using CAD software designed 3D surgical template during gingivectomy procedure. In this case report, 3D diagnostic data was collected from patients in need of esthetic anterior restoration, integrated on CAD software and applied to virtual articulator. Treatment outcome was simulated by creating virtual patient with dynamic occlusion. Esthetic anterior fixed restoration was fabricated by applying 3D surgical template designed on CAD software to gingivectomy procedure. To make sure that anterior guidance was formed in harmony with the patient's function pathway, occlusion was assessed following every step. The results were both functionally and esthetically satisfying.

Accuracy evaluation of treatment plan according to CT scan range in Head and Neck Tomotherapy (두경부 토모테라피 치료 시 CT scan range에 따른 치료계획의 정확성 평가)

  • Kwon, Dong Yeol;Kim, Jin Man;Chae, Moon Ki;Park, Tae Yang;Seo, Sung Gook;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.13-24
    • /
    • 2019
  • Purpose: CT scan range is insufficient for various reasons in head and neck Tomotherapy®. To solve that problem, Re-CT simulation is good because CT scan range affects accurate dose calculations, but there are problems such as increased exposure dose, inconvenience, and a change in treatment schedule. We would like to evaluate the minimum CT scan range required by changing the plan setup parameter of the existing CT scan range. Materials and methods: CT Simulator(Discovery CT590 RT, GE, USA) and In House Head & Neck Phantom are used, CT image was acquired by increasing the image range from 0.25cm to 3.0cm at the end of the target. The target and normal organs were registered in the Head & Neck Phantom and the treatment plan was designed using ACCURAY Precision®. Prescription doses are Daily 2.2Gy, 27 Fxs, Total Dose 59.4Gy. Target is designed to 95%~107% of prescription dose and normal organ dose is designed according to SMC Protocol. Under the same treatment plan conditions, Treatment plans were designed by using five methods(Fixed-1cm, Fixed-2.5cm, Fixed-5cm, Dynamic-2.5cm Dynamic-5cm) and two pitches(0.43, 0.287). The accuracy of dose delivery for each treatment plan was analyzed by using EBT3 film and RIT(Complete Version 6.7, RIT, USA). Results: The accurate treatment plan that satisfying the prescribed dose of Target and the tolerance dose in normal organs(SMC Protocol) require scan range of at least 0.25cm for Fixed-1cm, 0.75cm for Fixed-2.5cm, 1cm for Dynamic-2.5cm, and 1.75cm for Fixed-5cm and Dynamic-5cm. As a result of AnalysisAnalysis by RIT. The accuracy of dose delivery was less than 3% error in the treatment plan that satisfied the SMC Protocol. Conclusion: In case of insufficient CT scan range in head and neck Tomotherapy®, It was possible to make an accurate treatment plan by adjusting the FW among the setup parameter. If the parameter recommended by this author is applied according to CT scan range and is decide whether to re-CT or not, the efficiency of the task and the exposure dose of the patient are reduced.