• 제목/요약/키워드: dynamic jaw

검색결과 28건 처리시간 0.025초

3-죠오 척의 동적 파악력에 관한 연구 (Stduy on the Dynamic Gripping Force of a 3-Jaw Chuck)

  • 박태원
    • 한국정밀공학회지
    • /
    • 제8권4호
    • /
    • pp.126-136
    • /
    • 1991
  • In order to reduce the possibilities of personnel injuries and damages to machines and to obtaim higher efficiency and machining accuracy in the manufacturing system, the chucking technology has recentry become important. The chucking technology of work greatly affects both the grometrical accuracy and fonctional performance of the workpiece. In this study, the dynamic gripping force of a 3-jaw power chuck is investigated on the factors of the shape of jaw and the shape of workpiece. From this investigation, the following observations are obtained. 1) The higher stiffness of workpiece is, the higher decrease of dynamic gripping force is. 2) The nearer to the root of jaw is, the higher decrease of dynamic gripping force is. 3) The centrifugal force of affectting the decrease of dynamic gripping force has to be considered in the centrifugal force of affecting jaw.

  • PDF

불확실 동적 환경에서 다각형 부품의 평행-턱 파지 계획 (Parallel-Jaw Grasp Planning of Polygonal Parts in Uncertain Dynamic Environments)

  • 한인환;조정호
    • 한국정밀공학회지
    • /
    • 제14권4호
    • /
    • pp.126-135
    • /
    • 1997
  • A sensorless motion planner which succeeds in grasping a polygonal part firmly into a desired orientation has been developed through the dynamic analysis. The analytical results on the impact process with friction are used for modeling the contact motionduring the parallel-jaw grasp operation, which is com- posed of the pushing and the squeezing process. The developed planner succeeds in grasping a part into a specified orientation in the face of uncertainties of initial position and orientation of the part, motion direction of the finger, and the physical parameters such as the coefficients of friction and restitution. The motion planner has been fully implemented into a viable package on the computer system, and verified experimentally. The motion of parts is recorded using a high-speed video camera, and then compared to the results of the planner and the graphic simulation results that illustrate the simulated motion of the grasp operation.

  • PDF

Coordinative movement of articulators in bilabial stop /p/

  • Son, Minjung
    • 말소리와 음성과학
    • /
    • 제10권4호
    • /
    • pp.77-89
    • /
    • 2018
  • Speech articulators are coordinated for the purpose of segmental constriction in terms of a task. In particular, vertical jaw movements repeatedly contribute to consonantal as well as vocalic constriction. The current study explores vertical jaw movements in conjunction with bilabial constriction in bilabial stop /p/ in the context /a/-to-/a/. Revisiting kinematic data of /p/ collected using the electromagenetic midsagittal articulometer (EMMA) method from seven (four female and three male) speakers of Seoul Korean, we examined maximum vertical jaw position, its relative timing with respect to the upper and lower lips, and lip aperture minima. The results of those dependent variables are recapitulated in terms of linguistic (different word boundaries) and paralinguistic (different speech rates) factors as follows. Firstly, maximum jaw height was lower in the across-word boundary condition (across-word < within-word), but it did not differ as a function of different speech rates (comfortable = fast). Secondly, more reduction in the lip aperture (LA) gesture occurred in fast rate, while word-boundary effects were absent. Thirdly, jaw raising was still in progress after the lips' positional extrema were achieved in the within-word condition, while the former was completed before the latter in the across-word condition. Lastly, relative temporal lags between the jaw and the lips (UL and LL) were more synchronous in fast rate, compared to comfortable rate. When these results are considered together, it is possible to posit that speakers are not tolerant of lenition to the extent that it is potentially realized as a labial approximant in either word-boundary condition while jaw height still manifested lower jaw position in the across-word boundary condition. Early termination of vertical jaw maxima before vertical lower lip maxima across-word condition may be partly responsible for the spatial reduction of jaw raising movements. This may come about as a consequence of an excessive number of factors (e.g., upper lip height (UH), lower lip height (LH), jaw angle (JA)) for the representation of a vector with two degrees of freedom (x, y) engaged in a gesture-based task (e.g., lip aperture (LA)). In the task-dynamic application toolkit, the jaw angle parameter can be assigned numerical values for greater weight in the across-word boundary condition, which in turn gives rise to lower jaw position. Speech rate-dependent spatial reduction in lip aperture may be able to be resolved by means of manipulating activation time of an active tract variable in the gestural score level.

MDO기법에 의한 임프란트설계에서 요구되는 저작시 상.하악골치아사이의 충격력 계산 (Calculation of the Impact Force Applied on the Tooth of Upper and Lower Jaw-Bones in Masticating for the Design of a Dental Implant System.)

  • 권영주
    • 한국CDE학회논문집
    • /
    • 제7권1호
    • /
    • pp.27-33
    • /
    • 2002
  • MDO(Multidisciplinary Design Optimization) methodology is a new technology to solve a complicate design problem with a large number of design variables and constraints. The design of a dental implant system is a typical complicate problem, and so it requires the MDO methodology. Actually, several analyses such as rigid body dynamic analysis and structural stress analysis etc. should be carried out in the MDO methodology application to the design of a dental implant system. In this paper, as a first step of MDO methodology application to the design of a dental implant system, the impact force which is applied on the tooth in masticating is calculated through the rigid body dynamic analysis of upper and lower jaw-bones. This analysis is done using ADAMS. The impact force calculated through the rigid body dynamic analysis can be used for the structural stress analysis of a dental implant system which is needed for the design of a dental implant system. In addition, the rigid body dynamic analysis results also show that the impact time decreases as the impact force increases, the largest impact force occurs on the front tooth, and the impact force is almost normal to the tooth surface with a slight tangential force.

임프란트설계를 위한 저작시 상.하악골치아 사이의 충격력 계산 (Calculation of Impact Force between Teeth of Upper and Lower Jaw-Bones while Masticating for Dental Implant System Design)

  • 권영주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.425-428
    • /
    • 2000
  • In this paper the impact force which occurs on each tooth of jaw-bones while masticating is calculated through the rigid body dynamic analysis. This analysis is done by ADAMS. The impact force calculated in this paper is required for the structural stress analysis of implant system which is needed for the implant system design. The analysis results show that the impact time decreases as the impact force increases, the largest impact force occurs on the front tooth and the impact force is almost normal to the tooth surface together with slight tangential force.

  • PDF

고중량의 원통형 작업대상물 파지용 집게형 그리퍼의 슬립 조건과 이를 반영한 설계 및 해석 (Slip Considered Design and Analysis Pincers-type Gripper for Seizing Heavy-weighted Cylindrical Objects)

  • 최정현;안진웅;이상문;장명언
    • 로봇학회논문지
    • /
    • 제10권4호
    • /
    • pp.193-199
    • /
    • 2015
  • This paper dealt with a pincers-type gripper being able to grip a heavy-weighted cylindrical object having various size with itself. This gripper should be designed to seize the objects without any change of jaw shape. Grasping achieved equilibrium after the object slipped on the jaw while grasping it. To cope with this situation, we suggested the slip considered gripper design procedure based on grasping equilibrium. The obtained slip condition can provide a limit friction coefficient depending on the contact angle when initiating contact between jaw and object. Consequently, the gripping force and the required actuating force can be calculated. In order to verify the proposed slip condition, the simulations were performed using a dynamic software.

토모테라피 Edge 모드를 이용한 임상적 유용성 고찰 (Dosimetric and clinical review on the application of TOMO_edge mode)

  • 김이지
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.177-182
    • /
    • 2014
  • 목 적 : 토모테라피(Tomotherapy)의 두 가지 빔 모드(fixed jaw, dynamic jaw)에 따른 선량 분포 특성과 치료 시간의 차이를 분석하여 dynamic jaw(DJ)를 이용한 Tomo_edge 모드의 임상적 유용성을 고찰하고자 하였다. 대상 및 방법 : 토모테라피를 이용하여 치료받은 환자 7명을 대상으로 임상에서 보편적으로 사용되는 fixed jaw(FJ)를 이용하여 치료 계획을 수립하였다. 각각의 환자에서 모두 동일한 선량계획조건을 부여하였고, 토모테라피의 치료계획 인자인 Modulation Factor(MF), Pitch를 동일하게 유지한 상태에서 1) 동일한 조사면을 적용하고 FJ 와 DJ를 적용한 치료 계획을 비교하였다. 2) FJ를 적용한 치료 계획과 한 단계 큰 조사면과 DJ를 적용한 치료 계획을 비교하였다. 각 실험의 결과는 선량분포의 특성을 확인하기 위하여 종양체적 내 최소값(Dmin)과 선량 조형지수(CI=$V_{95%}$/TV)를 비교하고 표적을 포함한 조사영역 내 체적의 누적선량을 분석하였다. 또한, 임상적 유용성을 확인하기 위하여 빔 조사시간과 MU의 증감을 비교 분석하였다. 결 과 : 동일한 조사면을 적용하고 FJ와 DJ를 적용한 경우, $V_{75%}$은 1.04%, $V_{50%}$은 4.75% 감소하였고, $V_{25%}$은 7.6%, $V_{10%}$은 11.91% 감소하였다. FJ를 적용한 치료계획보다 한 단계 큰 조사면과 DJ를 적용한 경우에 Dmin은 0.72%, CI는 1.25% 줄어들었고, 동일 조사면을 적용한 경우와 마찬가지로 $V_{x%}$는 저선량 영역으로 갈수록 크게 감소하여 $V_{10%}$이 6.13%의 감소 값을 나타냈다. 빔 조사시간과 누적 MU는 동일 조사면 적용 시 각각 3.66%와 3.77%의 값으로 증가하였으나, 한 단계 큰 조사면을 적용한 경우, 빔 조사시간이 31.55%로 누적 MU는 32.28%으로 크게 감소하였음을 보여준다. 결 론 : 동일한 조사면을 사용하면서 DJ를 사용하는 경우, 표적의 선량분포를 거의 변화시키지 않으면서 환자의 용적선량을 효과적으로 감소시킬 수 있었다. 보다 큰 조사면을 사용하는 것과 동시에 DJ를 사용하는 경우는 일부 선량조형성의 저하를 나타내었으나 환자의 용적선량이 감소하고 치료 시간을 감소시킴으로써 Tomo-edge 모드는 임상적으로 유용한 것으로 사료된다.

구강악안면영역에서 초음파영상 진단 (Clinical Usefulness of Ultrasonography in Oral and Maxillofacial Regions)

  • 오송희;최용석
    • 대한치과의사협회지
    • /
    • 제57권11호
    • /
    • pp.690-699
    • /
    • 2019
  • Ultrasound sonography(US) is used to evaluate various diseases of maxillofacial region including salivary glands, soft tissue and jaw lesions because of easy accessibility and no hazard of ionizing radiation. Also, US can offer dynamic study showing real-time images during diagnostic or surgical procedure. US images provide accurate information about the internal features of lesions on the jaw prior to surgical treatment. Doppler images are used to visualize the vascular distribution of the lesions and to provide additional information to enhance diagnostic value. Nevertheless, the clinical application of US imaging is limited in the dental field. This is due to the lack of knowledge about the US image and the image characteristics of the anatomical structures. It is necessary to evaluate the diagnostic value of US and evaluate its usefulness by looking at clinical cases using US images. Therefore, US imaging may be recommended as an assistant image in evaluating jaw lesions. US images provided accurate information about the internal structure of lesions on the jaw prior to surgical treatment, and diagnostic value was enhanced by visualizing the vascular distribution of the lesion using doppler imaging.

  • PDF

선량계측인자에 따른 기능강화동적쐐기와 금속쐐기의 비교 (Comparison of Enhanced Dynamic Wedge with Physical Metal Wedge based on the Basic Dosimetric Parameters)

  • 이정우;홍세미;최경식;정진범;최보영;장홍석;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제16권2호
    • /
    • pp.70-76
    • /
    • 2005
  • 기능강화동적쐐기는 쐐기 형태의 선량 분포를 만드는 방법과 선량 특성적인 면에서 금속쐐기와 상당한 차이를 가지고 있다. 기능강화동적쐐기의 임상적용을 위해서는 금속쐐기와 다른 선량특성을 분석하고 이에 따른 적절한 커미셔닝이 필수적이다. 본 연구의 목적은 기본 선량계측인자에 기초한 기능강화동적래기와 금속쐐기의 선량특성을 분석하는 데 있다 선량 계측학적 특성을 나타내는 심부선량분포, 조사면 주변 선량, 표면선량, 실효 쐐기인자, 쐐기의 선량측면도를 측정, 분석하였다. 또한 열린 조사면과 금속쐐기와의 비교측정을 통해 기능강화동적쐐기가 가지고 있는 고유한 특성을 분석하였다. 기능강화동적쐐기의 선량측면도 측정은 Chamber Array 24 (CP24)를 이용하였으며, Golden Segmented Treatment Table (Golden-577)로 구현한 치료 계획 장치의 계산 값과 비교하였다. 또한 실호쐐기인자 측정은 각각의 X, Y 콜리메이터에 따른 특성을 분석하였다. 심부 선량 백분율측정에서 열린 조사면과 기능강화쐐기의 비교결과, $0.2\~0.5\%$ 이내로 일치하였고, 금속 쐐기인 경우 약 $2\%$의 비교적 큰 차이를 보였다. 조사면 주변선량측정에서는 금속쐐기가 약 $1\%$ 높았다. 표면선량 측정 결과, 금속쐐기가 약 $10\%$ 낮게 평가되었다 기능강화쐐기의 실효쐐기인자는 Y jaw가 커짐에 따라 연속적으로 감소됨을 알 수 있었다. X jaw에 따른 쐐기인자 의존도 측정에서는 X jaw에 따른 의존도는 거의 없는 것으로 평가되었다. 또한 비대칭 조사면의 쐐기 인자측정에서는 비대칭에 상관없이 Y jaw의 크기만 같으면 실효쐐기인자가 같았다. 선량측면도 측정에서는 CA24를 이용해 얻은 실측값과 Golden STT로 Cadplan에서 구현한 계산 값이 $1\%$이내로 일치하였다. 본 연구를 통해 기능강화동적쐐기가 가지고 있는 특성을 분석하였으며, 금속쐐기를 대체할 수 있는 유용한 도구임을 알 수 있었다.

  • PDF

Dynamic Wedge의 조직내 방사선량 분포의 특성 (Dosimetric Characteristics of Dynamic Wedge Technique)

  • 오영택;금기창;추성실;김귀언
    • Radiation Oncology Journal
    • /
    • 제14권4호
    • /
    • pp.323-332
    • /
    • 1996
  • 목적 : 방사선 치료에 있어서 조직내 등선량 분포곡선을 변형시킬 목적으로 쐐기 차폐물이 사용되고 있는데 최근 기존의 고정 쐐기와는 다르게 비대칭적인 콜리메이터인 Independent Jaw에 의해 등선량 분포곡선을 변형시키는 동적 쐐기 기법이 실용화 되고 있으나 아직 그 방사선 물리학적인 특성에 대해서는 잘 알려져 있지 않다. 이에 본 저자는 기존의 고정 쐐기와 비교하여 조직내 방사선량 분포의 특성을 알아보고자 본 연구를 계획하였다. 대상 및 방법 : 물 판톰, 폴리 스타이린 판톰, 평균 유방 모형 판톰을 대상으로 전리함, 필름, TLD 등을 이용하여 동적 쐐기와 고정 쐐기의 선량 분포를 측정하여 비교하였다. 방사선원은 선형 가속기의 6MV x선을 사용하였고 $15{\times}15$ 조사면에서 15, 30, 45도 쐐기를 이용하였다 조직내선량 분포는 전리함과 필름 선량계를 사용하였고, 유방 접선 치료방식에서의 반대편 유방 조사선량은 TLD를 사용하였다. 결과 : 1) 조직내 $\%$심도 선량은 고정 쐐기의 경우 심도 선량 깊이가 깊어지는 방사선의 경화 현상이 뚜렷하였으나 동적 쐐기의 경우에는 발견할 수 없었으며 그 $\%$심도선량은 개방 조사면과 유사하였다. 2) 조직내 등선량 분포 곡선을 보면 동적 쐐기의 경우 고정 쐐기와는 달리 원하는 깊이, 원하는 조사면에서 원하는 쐐기 각도를 얻을 수 있었으며 쐐기 각도를 이루는 등선량 분포 곡선이 고정 쐐기에 비해 더욱 직선적이었다. 3) 산란선량은 동적 쐐기의 경우 개방 조사면과 그 양이 거의 동일하였으며 유방보존술에서의 접선 조사방식의 방사선치료에서 고정 쐐기 대신에 동적 쐐기를 사용함으로써 반대측 유방으로의 피폭선량을 감소시킬 수 있었다. 결론적으로 동적 쫴기 기법은 단순히 고정 쐐기를 대체할 수 있을 뿐만 아니라 고정 쐐기의 단점을 보완해 줄 수 있으며 향후 방사선 치료에 있어서 더 다양한 유용성을 가질 수 있으리라 생각한다.

  • PDF