• Title/Summary/Keyword: dynamic earthquake loads

Search Result 216, Processing Time 0.025 seconds

Distributed plasticity approach for the nonlinear structural assessment of offshore wind turbine

  • Tran, Thanh-Tuan;Hussan, Mosaruf;Kim, Dookie;Nguyen, Phu-Cuong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.743-754
    • /
    • 2020
  • This study provides an insight of the nonlinear behavior of the Offshore Wind Turbine (OWT) structure using the distributed plasticity approach. The fiber section beam-column element is applied to construct the finite element model. The accuracy of the proposed model is verified using linear analysis via the comparison of the dynamic characteristics. For collapse risk assessment of OWT, the nonlinear effects considering the earthquake Incident Angle (IA) have been evaluated first. Then, the Incremental Dynamic Analysis (IDA) has been executed using a set of 20 near-fault records. Lastly, fragility curves are developed to evaluate the vulnerability of structures for different limit states. Attained results justify the accuracy of the proposed approach for the structural response against the ground motions and other environmental loads. It indicates that effects of static wind and wave loads along with the earthquake loads should be considered during the risk assessment of the OWT structure.

Reducing Effect Analysis on Earthquake Response of 100m Spanned Single-Layered Lattice Domes With LRB Seismic Isolation System (LRB 면진 장치를 갖는 100m 단층 래티스 돔의 지진 응답에 대한 감소 효과 분석)

  • Park, Kang-Geun;Lee, Dong-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.1
    • /
    • pp.53-64
    • /
    • 2019
  • The objective of this study is to investigate the earthquake response for the design of 100m spanned single-layer lattice dome. The plastic hinge analysis and eigenvalue buckling analysis are performed to estimate the ultimate load of single-layered lattice domes under vertical loads. In order to ensure the stability of lattice domes, it is investigated for the plastic hinge progressive status by the pushover increment analysis considering the elasto-plastic connection. One of the most effective methods to reduce the earthquake response of large span domes is to install the LRB isolation system of a dome. The authors discuss the reducing effect for the earthquake dynamic response of 100m spanned single-layered lattice domes. The LRB seismic isolation system can greatly reduce the dynamic response of lattice domes for the horizontal and vertical earthquake ground motion.

Performance Evaluation of Multi-Hazard Adaptive Smart Control Technique Based on Connective Control System (연결 제어 시스템 기반의 멀티해저드 적응형 스마트 제어 기술 성능 평가)

  • Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.97-104
    • /
    • 2018
  • A connected control method for the adjacent buildings has been studied to reduce dynamic responses. In these studies, seismic loads were generally used as an excitation. Recently, multi-hazards loads including earthquake and strong wind loads are employed to investigate control performance of various control systems. Accordingly, strong wind load as well as earthquake load was adopted to evaluate control performance of adaptive smart coupling control system against multi-hazard. To this end, an artificial seismic load in the region of strong seismicity and an artificial wind load in the region of strong winds were generated for control performance evaluation of the coupling control system. Artificial seismic and wind excitations were made by SIMQKE and Kaimal spectrum based on ASCE 7-10. As example buildings, two 20-story and 12-story adjacent buildings were used. An MR (magnetorheological) damper was used as an adaptive smart control device to connect adjacent two buildings. In oder to present nonlinear dynamic behavior of MR damper, Bouc-Wen model was employed in this study. After parametric studies on MR damper capacity, optimal command voltages for MR damper on each seismic and wind loads were investigated. Based on numerical analyses, it was shown that the adaptive smart coupling control system proposed in this study can provide very good control performance for Multi-hazards.

SIMPLE AND EFFICIENT METHODS FOR THE RESPONSE ESTIMATION BY GROUP WALKING LOADS (무리보행하중이 작용하는 건축물의 간편한 응답추정)

  • 김태호;민경원;이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.117-124
    • /
    • 2003
  • Long span structures with low natural frequencies such as shopping malls, large offices, and assembly rooms may experience signification dynamic responses due to human activities. In this study, equations to estimate the magnitudes of group walking loads are derived and a simple procedure to estimate and evaluate the corresponding response of the existing and new building structures subjected to human loads is proposed. The effectiveness of the proposed method is verified analytically using a simple floor and experimentally on a footbridge measuring the structural response induced by group pedestrians. Results indicate that the amplitudes of group walking loads can be easily estimated if the mode shapes are available, and that the corresponding structural responses can be estimated easily by the simple response measurement using the proposed method.

  • PDF

Dynamic Nonlinear Analysis Model for Reinforced Concrete Elements considering Strain Rate Effects under Repeated Loads (변형율속도를 고려한 반복하중을 받는 철근콘크리트 부재의 동적 비선형 해석모델)

  • 심종성;문일환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.04a
    • /
    • pp.78-83
    • /
    • 1990
  • The current analytical techniques for R/C elements under severe dynamic repeated loads, like earthquake or impact, has two major problems; one is that the effects of strain rate are not considered and the other one is the current model was developed based on flexural behavior only. Thus, this study develops a computer software that can idealize the flexural and shear behavior of R/C elements using several parameters and also can consider the effects of strain rate. The analytical results using the developed analytical technique were compared with several experimental results and were generally satisfied.

  • PDF

Performance assessment of multi-hazard resistance of Smart Outrigger Damper System (스마트 아웃리거 댐퍼시스템의 멀티해저드 저항성능평가)

  • Kim, Hyun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.139-145
    • /
    • 2018
  • An outrigger system is used widely to increase the lateral stiffness of high-rise buildings, resulting in reduced dynamic responses to seismic or wind loads. Because the dynamic characteristics of earthquake or wind loads are quite different, a smart vibration control system associated with an outrigger system can be used effectively for both seismic and wind excitation. In this study, an adaptive smart structural control system based on an outrigger damper system was investigated for the response reduction of multi-hazards, including seismic and wind loads. A MR damper was employed to develop the smart outrigger damper system. Three cities in the U.S., L.A., Charleston, and Anchorage, were used to generate multi-hazard earthquake and wind loads. Parametric studies on the MR damper capacity were performed to investigate the optimal design of the smart outrigger damper system. A smart control algorithm was developed using a fuzzy controller optimized by a genetic algorithm. The analytical results showed that an adaptive smart structural control system based on an outrigger damper system can provide good control performance for multi-hazards of earthquake and wind loads.

Dynamic Behavior Characteristics According to Arch Types of Arched Stone Bridge Subjected to Seismic Load (지진 하중을 받는 홍예교의 아치 형태에 따른 동적 거동 특성)

  • Kim, Ho-Soo;Lee, Seung-Hee;Jeon, Gun-Woo;Bang, Hyeok-Kyu
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.45-55
    • /
    • 2018
  • The arched stone bridge has been continuously deteriorated and damaged by the weathering and corrosion over time, and also natural disaster such as earthquake has added the damage. However, masonry stone bridge has the behavior characteristics as discontinuum structure and is very vulnerable to lateral load such as earthquake. So, it is necessary to analyze the dynamic behavior characteristics according to various design variables of arched stone bridge under seismic loads. To this end, the arched stone bridge can be classified according to arch types, and then the discrete element method is applied for the structural modelling and analysis. In addition, seismic loads according to return periods are generated and the dynamic analysis considering the discontinuity characteristics is carried out. Finally, the dynamic behavior characteristics are evaluated through the structural safety estimation for slip condition.

Seismic behavior of fuel assembly for pressurized water reactor

  • Jhung, Myung J.;Hwang, Won G.
    • Structural Engineering and Mechanics
    • /
    • v.2 no.2
    • /
    • pp.157-171
    • /
    • 1994
  • A general approach to the dynamic time-history analysis of the reactor core is presented in this paper as a part of the fuel assembly qualification program. Several detailed core models are set up to reflect the placement of the fuel assemblies within the core shroud. Peak horizontal responses are obtained for each model for the motions induced form earthquake. The dynamic responses such as fuel assembly deflected shapes and spacer grid impact loads are carefully investigated. Also, the sensitivity responses are obtained for the earthquake motions and the fuel assembly non-linear response characteristics are discussed.

Vibrations of rotationally restrained Timoshenko beam at hinged supports during an earthquake

  • Kim, Yong-Woo;Ryu, Jeong Yeon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1066-1078
    • /
    • 2020
  • The present paper describes an analytic solution procedure for flexural vibration of a rotationally restrained hinged-hinged Timoshenko beam at the supports during an earthquake. Focusing on maximal magnitudes of internal loads such as bending moment and shearing force under wide variations of two parameters, kL/EI and kGAL2/EI, various beams under synchronous and asynchronous support motions are simulated. The simulations under asynchronous support motions show the following facts. The variations of the maximal magnitudes of internal loads of stocky beams due to the variation of kL/EI from zero to infinity show much wider variations than those of slender beams as kGAL2/EI decreases. The maximal magnitudes of internal loads of a beam tend to be governed by their static components as kL/EI increases and kGAL2/EI decreases. When the internal loads are governed by their static components, maximal magnitudes of internal loads of the stocky tend to increase monotonically as the value of kL/EI increases. However, the simulations under synchronous support motions show the static components of the internal loads vanish and the internal loads are governed by dynamic components irrespective of the two parameters.

Research on Coupling Control of Adjacent Buildings under Multiple Hazards (다중재난하중을 받는 인접건물의 연결제어에 대한 연구)

  • Kwag, Shinyoung;Kim, Hyun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.36-41
    • /
    • 2016
  • In this study, numerical analyses were used to investigate the performance of a coupling control method for the dynamic responses of adjacent buildings under multiple hazards. Numerical simulations were done using the earthquake loads of regions with strong seismicity in Los Angeles, California, and the wind loads in regions with strong winds in Charleston, North Carolina. The artificial earthquake and wind loads were made using SIMQKE and Kaimal Spectrum based on ASCE 7-10. Ten-story and twenty-story adjacent buildings were selected as example structures, and nonlinear hysteretic dampers were used to connect them. The Bouc-Wen model was used to model the nonlinear hysteretic dampers. The results show that the proposed control method could effectively reduce the dynamic responses, and the optimal control designs were different for each hazard.