• 제목/요약/키워드: dynamic degradation

검색결과 392건 처리시간 0.022초

포화사질토의 동적거동규명을 위한 수정 교란상태개념 (Modified Disturbed State Concept for Dynamic Behaviors of Fully Saturated Sands)

  • 최재순;김수일
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.107-114
    • /
    • 2003
  • There are many problems in the prediction of dynamic behaviors of saturated soils because undrained excess pore water pressure builds up and then the strain softening behavior is occurred simultaneously. A few analytical constitutive models based on the effective stress concept have been proposed but most models hardly predict the excess pore water pressure and strain softening behaviors correctly In this study, the disturbed state concept (DSC) model proposed by Dr, Desai was modified to predict the saturated soil behaviors under the dynamic loads. Also, back-prediction program was developed for verification of modified DSC model. Cyclic triaxial tests were carried out to determine DSC parameters and test result was compared with the result of back-prediction. Through this research, it is proved that the proposed model based on the modified disturbed state concept can predict the realistic soil dynamic characteristics such as stress degradation and strain softening behavior according to dynamic process of excess pore water pressure.

  • PDF

교량거동에 미치는 기초의 회전 및 병진운동의 영향 (Effects of Foundation Motions on Dynamic Behaviors of a Bridge under Seismic Excitations)

  • 김상효;마호성;함형진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.216-222
    • /
    • 1998
  • Effects of translational and rotational motions of the foundation on the dynamic behaviors of a bridge under seismic excitations are examined by utilizing a simplified 3 degree-of-freedom of system. To consider the nonlinear characteristics of the RC pier, a hysteresis model is adapted, which can simulate the inelastic motion of the pier with the stiffness degradation. From results, the portion of the total displacement due to rotational motion of the foundation becomes larger as applied seismic excitation increases.

  • PDF

ServerNet and ATM Interconnects: Comparison for Compressed Video Transmission

  • Ashfaq Hossain;Kang, Sung-Mo;Robert Horst
    • Journal of Communications and Networks
    • /
    • 제1권2호
    • /
    • pp.134-142
    • /
    • 1999
  • We have developed fully functional Video Server and Client applications which can transmit, receive, decompress and display compressed video over various networks. Our video trans-port allows dynamic rate control feedback, loss detection, and repair requests from Clients to the Server. Our experiments show how feedvack-before-degradation scheme for rate adaptation maintains good display frame-rate for video playback. We show how the playback degradation(reduction in display frame-rate) oc-curs and what happens if corrective measures are not taken to im-prove the situation. The degradation is attributed to the increased internal kernel buffering which consumes scarce CPU resources. We demontrate with our experimental results that ServerNet, with improved hardware delivery guarantees, can significantly reduce host CPU resource consumption while serving video streams. We present the maximum number of streams which can be served for each of ATM and ServerNet interconnects. The appropriate user-level packet size for the video server are also determined for each case.

  • PDF

외부 후긴장 공법 적용에 따른 무도상 판형교의 동적거동 분석 (A Study on Dynamic Behaviors of Steel Plate Girder bridge with Applying External Post-Tensioning Method)

  • 최동호;최정열;최준혁;박용걸
    • 한국철도학회논문집
    • /
    • 제9권2호
    • /
    • pp.160-168
    • /
    • 2006
  • The major objective of this study is to investigate the effects and application of external post-tensioning method far steel plate girder bridge. It analyzed the mechanical behaviors of steel plate girder bridge with applying external post-tensioning on the finite element analysis, field test and laboratory test fur the lateral dynamic characteristics. As a result, the reinforcement of steel plate girder bridge the external post-tensioning method are obviously effective for the lateral dynamic response which is non-reinforced. The analytical and experimental study are carried out to investigate the post-tension force decrease lateral acceleration and deflection on steel plate girder bridge for serviceability. And the external post-tensioning method reduce dynamic maximum displacement(about $10{\sim}24%$), the increase of dynamic safety is predicted by adopting external post-tensioning method. From the dynamic test results of the servicing steel plate girder bridge, it is investigated that the change degree of natural frequency is very low with applying the external post-tensioning method The servicing steel plate girder bridge with external post-tensioning has need of the reasonable reinforcement measures which could be reducing the effect of lateral dynamic behavior that degradation phenomenon of structure by an unusual response characteristic and a drop durability.

동적 형상 변경 관리를 지원하는 통합 애플리케이션 프레임워크의 설계 및 구현 (Design and Implementation of Integration Application Framework Supporting Dynamic Configuration)

  • 이용환;민덕기
    • 한국IT서비스학회지
    • /
    • 제4권1호
    • /
    • pp.117-128
    • /
    • 2005
  • When we conduct development of a large-size SI project, it is highly necessary to utilize an appropriate application framework which helps to build a qualified software with high productivity in a short period of time. In this paper, we propose the architecture of a dynamically reconfigurable CBD application integration framework that has been used for developing large-scale e-business applications to achieve high development productivity and maintainability. This Integration framework can easily extend its functionalities, and dynamically change its configuration during run time according to the business category, such as applying interaction patterns among main components in software architecture, rules, policies, and environmental parameters. Dynamic reconfiguration has the feature to make applications be easily customized for changeable requirements. Through our application integration framework, huge sizes of contents can be managed according to the business category as well, by keeping configuration informations and huge volumes of source codes. In order to evaluate out application integration framework in terms of performance criteria, we present experimental results of throughputs from the framework by yielding dynamic configuration without any performance degradation.

Reliability analysis of repairable k-out-n system from time response under several times stochastic shocks

  • Fang, Yongfeng;Tao, Wenliang;Tee, Kong Fah
    • Smart Structures and Systems
    • /
    • 제14권4호
    • /
    • pp.559-567
    • /
    • 2014
  • The model of unit dynamic reliability of repairable k/n (G) system with unit strength degradation under repeated random shocks has been developed according to the stress-strength interference theory. The unit failure number is obtained based on the unit failure probability which can be computed from the unit dynamic reliability. Then, the transfer probability function of the repairable k/n (G) system is given by its Markov property. Once the transfer probability function has been obtained, the probability density matrix and the steady-state probabilities of the system can be retrieved. Finally, the dynamic reliability of the repairable k/n (G) system is obtained by solving the differential equations. It is illustrated that the proposed method is practicable, feasible and gives reasonable prediction which conforms to the engineering practice.

Analysis of structural dynamic reliability based on the probability density evolution method

  • Fang, Yongfeng;Chen, Jianjun;Tee, Kong Fah
    • Structural Engineering and Mechanics
    • /
    • 제45권2호
    • /
    • pp.201-209
    • /
    • 2013
  • A new dynamic reliability analysis of structure under repeated random loads is proposed in this paper. The proposed method is developed based on the idea that the probability density of several times random loads can be derived from the probability density of single-time random load. The reliability prediction models of structure based on time responses under several times random loads with and without strength degradation are obtained by using the stress-strength interference theory and probability density evolution method. The resulting differential equations in the prediction models can be solved by using the forward finite difference method. Then, the probability density functions of strength redundancy of the structures can be obtained. Finally, the structural dynamic reliability can be calculated using integral method. The efficiency of the proposed method is demonstrated numerically through a speed reducer. The results have shown that the proposed method is practicable, feasible and gives reasonably accurate prediction.

숨쉬는 벽체를 적용한 건물에서의 실내공기질(IAQ) 개선 효과 분석 (IAQ improvement effect analysis in Dynamic Breathing Building(DBB))

  • 박용대;이진숙;강은철;이의준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.748-753
    • /
    • 2008
  • In modern buildings, the air-tightness and insulation for energy saving resulted in degradation of Indoor Air Quality(IAQ). It has brought out new diseases such as New Building Syndrome(NBS) and Sick Building Syndrome(SBS) to the tenants of such buildings. As a result, researches on the Dynamic Breathing Building(DBB) are being undertaken to minimize energy loss as well as to improve IAQ. DBB is a state-of-the-art technology to build channels inside the wall so that air migrates between indoor and outdoor, which improves insulation performance and IAQ. This study attempts to evaluate the improvement of DBB employed in real buildings. As analyzing tools, IAQ improvement and particle degradation while were evaluated while the required indoor ventilation rate was satisfied. DBB were installed in the twin test cells at Korea Institute of Energy Research(KIER). From the test, IAQ was compared with outdoor air base on the concentration of particle matter(PM10). As a results, the concentration of particle dust (PM10) within the breathing walls was reduced by 80% at 0.7 ACH, 67% at 2 ACH, 63% at 3 ACH respectively. As ACH is higher, Dnamic Isulation(DI) and normal wall permit more PM10 particles being infiltrated.

  • PDF

Dynamic experimental study on single and double beam-column joints in steel traditional-style buildings

  • Xue, Jianyang;Qi, Liangjie;Yang, Kun;Wu, Zhanjing
    • Structural Engineering and Mechanics
    • /
    • 제63권5호
    • /
    • pp.617-628
    • /
    • 2017
  • In order to study the failure mode and seismic behavior of the interior-joint in steel traditional-style buildings, a single beam-column joint and a double beam-column joint were produced according to the relevant building criterion of ancient architectural buildings and the engineering instances, and the dynamic horizontal loading test was conducted by controlling the displacement of the column top and the peak acceleration of the actuator. The failure process of the specimens was observed, the bearing capacity, ductility, energy dissipation capacity, strength and stiffness degradation of the specimens were analyzed by the load-displacement hysteresis curve and backbone curve. The results show that the beam end plastic hinge area deformed obviously during the loading process, and tearing fracture of the base metal at top and bottom flange of beam occurred. The hysteresis curves of the specimens are both spindle-shaped and plump. The ultimate loads of the single beam-column joint and double beam-column joint are 48.65 kN and 70.60 kN respectively, and the equivalent viscous damping coefficients are more than 0.2 when destroyed, which shows the two specimens have great energy dissipation capacity. In addition, the stiffness, bearing capacity and energy dissipation capacity of the double beam-column joint are significantly better than that of the single beam-column joint. The ductility coefficients of the single beam-column joint and double beam-column joint are 1.81 and 1.92, respectively. The cracks grow fast when subjected to dynamic loading, and the strength and stiffness degradation is also degenerated quickly.

Fatigue performance evaluation of reinforced concrete element: Efficient numerical and SWOT analysis

  • Saiful Islam, A.B.M.
    • Computers and Concrete
    • /
    • 제30권4호
    • /
    • pp.277-287
    • /
    • 2022
  • Due to the scarcity of extortionate experimental data, fatigue failure of the reinforced concrete (RC) element might be achieved economically adopting nonlinear finite element (FE) analysis as an alternative approach. However, conventional implicit dynamic analysis is expensive, quasi-static method overlooks interaction effects and inertia, direct cyclic analysis computes stabilized responses. Apart from this, explicit dynamic analysis may provide a numerical operating system for factual long-term responses. The study explores the fatigue behavior based on a simplified explicit dynamic solution employing nonlinear time domain analysis. Among fourteen RC beams, one beam is selected to validate under static loading, one under fatigue with the experimental study and other twelve to check the detail fatigue behavior. The SWOT (Strength, Weakness, Opportunities, Threats) analysis has been carried out to pinpoint the detail scenario in the adoption of numerical approach as an alternative to the experimental study. Excellent agreement of FE and experimental results is seen. The 3D nonlinear RC beam model at service fatigue limits is truthful to be used as an expedient contrivance to envisage the precise fatigue behavior. The simplified analysis approach for RC beam under fatigue offers savings in computation to predict responses providing acceptable accuracy rather than the complicated laboratory investigation. At higher frequency, the flexural failure occurs a bit earlier gradually compared to the repeated loading case of lower frequency. The deflection increases by 6%-10% at the end of first cycle for beams with increasing frequency of cyclic loading. However, at the end of fatigue loading, greater deflection occur earlier for higher load range because of more rapid stiffness degradation. For higher frequency, a slight boost in concrete compressive strains at an initial stage of loading has been seen indicating somewhat stepper increment. Stiffness degradation in larger loading cycle at same duration escalates the upsurge of the rate of strain in case of higher frequency.