• Title/Summary/Keyword: dynamic control

Search Result 7,935, Processing Time 0.035 seconds

Physical Characteristic and In vitro Transdermal Delivery of PCL-b-PEG Micelles Containing Quercetin and Rutin (Quercetin과 Rutin을 함유하는 PCL-b-PEG 고분자 미셀의 특성 및 피부 흡수에 관한 In vitro 연구)

  • Lim, Gyu-Nam;Kim, Sun-Young;Kim, Min-Ji;Park, Soo-Nam
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.420-426
    • /
    • 2012
  • In this study, we prepared polymer micelles containing quercetin and rutin, known as antioxidants, using poly(${\varepsilon}$-caprolactone)-b-poly(ethylene glycol), and evaluated in vitro skin permeation of the active materials. Quercetin and rutin loaded micelles were characterized by DSC (differential scanning calorimetry), HPLC (high performance liquid chromatography) and DLS (dynamic light scattering) measurements. The particle size of the polymer micelles increased in a concentration dependent manner (0.5~2.0% PCL-b-PEG). The Zeta potential of quercetin and rutin loaded micelles remained constant. To evaluate the skin penetration of PCL-b-PEG micelles, Franz diffusion cell experiment was performed. The aqueous solutions of quercetin and rutin were used as the control groups. Quercetin and rutin loaded PCL-b-PEG micelles showed more efficient skin permeation than the control groups. Safety assessment (patch test) of quercetin and rutin loaded PCL-b-PEG micelles on skin was performed to test application possibility of the polymer micelles to cosmetics. Any adverse symptoms were not observed.

Simulation Implementation of Fossil Power Plant Condensate Pumps' Rotation Operation Logic Using MATLAB/Simulink (MATLAB/Simulink를 이용한 화력발전소 복수펌프 순환기동로직 시뮬레이션 구현)

  • Yoon, Chang-Sun;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.693-699
    • /
    • 2016
  • The simulators for pump operation developed by domestic or overseas research have been developed for dynamic analysis or operator training purposes. However, previous developed simulators focused on the operators so they are unsuitable for logic designers or commissioning engineers who need to change the operation conditions or logics arbitrarily. In addition, the simulator for two or more condensate pumps' operation, which can be used easily by plant designers or operators, has not been developed. Accordingly, this paper suggests a simulation method that can be used easily for plant designers or operators using MATLAB Simulink. This suggestion helps users who can use MATLAB to implement ANSI/ISA S5.2, which is applied mainly for DCS (Distributed Control System). In addition, to implement the logics specified in the CODE, Sub-Systems were created for the block and evaluated to determine if they can be used in the simulator. In the working level stage using the suggested method, all error possibilities that might occur during the three pumps' rotation operation could be verified with the suggested simulator during the design stage or before operation.

Trial Manufacture and Disinfection Evaluation of Anoxic Chamber System for Museum Insects (저산소 농도 살충 챔버 시스템 시제작 및 박물관 해충 살충 성능 평가)

  • Oh, Joonsuk;Choi, Jungeun;Lee, Jangmook
    • Journal of Conservation Science
    • /
    • v.28 no.4
    • /
    • pp.377-385
    • /
    • 2012
  • Anoxic treatments using argon and nitrogen gas in controlled atmospheres have been used as a alternative to methyl bromide for insect disinfection in museums. Anoxic chamber system was manufactured and installed at The National Folk Museum of Korea for the first time in Korea. The internal capacity of anoxic chamber is 0.5m3 in which is able to use argon, nitrogen and carbon dioxide gas. This system is equipped with oxygen concentration, temperature and ralative humidity control devices and automatically controlled oxygen concentration from 0.01 to 20%, temperature from 10 to $50^{\circ}C$ and relative humidity 30 to 80%. To control the oxygen concentration, anoxic chamber system is adopted semi-dynamic method which supplies mixture of humidified gas and dry gas whenever oxygen concentration in chamber becomes higher than setting value. It has kept regularly oxygen concentration, temperature and relative humidity for 20 days using argon gas. To evaluate the disinfection of cigarette beetle larvae and adults and varied carpet beetle larvae, the anoxic chamber system maintained 0.01% of oxygen concentration, $25^{\circ}C$ in temperature and 50% in relative humidity for 30 days. Cigarette beetle larvae were killed in 7 days and adults in 3~5 days. And varied carpet beetle larvae were killed in 3 days. It reaches the conclusion form the evaluation this anoxic chamber system can be used to develop anoxic treatment as an alternative of methyl bromide for insect disinfection of infested cultural properties in museums.

RF performance Analysis for Galileo Receiver Design (갈릴레오 수신기 설계를 위한 RF 성능 분석에 관한 연구)

  • Chang, Sang-Hyun;Lee, Il-Kyoo;Park, Dong-Pil;Lee, Sang-Wook
    • Journal of Satellite, Information and Communications
    • /
    • v.5 no.1
    • /
    • pp.58-62
    • /
    • 2010
  • This paper presents the effects of RF performance parameters on the Galileo receiver design via simulation after reviewing the requirements of the Galileo receiver structure. At first, we considered the general requirements, structure and characteristics of the Galileo system. Then we designed the Galileo receiver focused on performance requirement of 16 dB C/N which is equal to 15 % Error Vector Magnitude(EVM) by using Advanced Design System(ADS) simulation program. In order to verify the function of Automatic Gain Control(AGC)), we measured the IF output power level by changing the input power level at the front - end of the receiver. We analyzed the performance degradation due to phase noise variations of Local Oscillator(LO) in the Galileo receiver through EVM when the minimum sensitivity level of -127 dBm is applied at the receiver. We also analyzed the performance degradation according to variable Analog-to-Digital Converter(ADC) bits within the Dynamic range, -92 ~ -139 dBm, which has been defined by gain range (-2.5 ~ +42.5 dB) in the AGC operation. The results clearly show that the performance of the Galileo receiver can be improved by increasing ADC bits and reducing Phase Noise of LO.

A Design Technique of Configurable Framework for Home Network Systems (홈 네트워크 시스템을 위한 재구성 프레임워크 설계 기법)

  • Kim, Chul-Jin;Cho, Eun-Sook;Song, Chee-Yang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1844-1866
    • /
    • 2011
  • In a home network system, each customer electronic device has the control data format chosen by its manufacturing company and there are various types of digital devices and protocols. Besides the mutual operating environments among the various devices are dissimilar. Affected by the characteristics explained above, home network systems can hardly support the crucial functions, such as data compatibility, concurrency control, and dynamic plug-in. Thus, the home network system shows relatively poor reusability. In this paper, we suggest design technique of configurable framework, which can widely support the variability, to increase the reusability of the home network system. We extract the different parts of the home network system as variation points, and define them as the variability types. We design a structure of configurable framework, and suggest customization technique of configurable framework through selection technique and plug-in technique. Also, we prove the reusability by applying the proposed framework and it methods to real-world home network systems and analyzing the measurement results of these case studies using software metrics. We can expect the proposed approach provides better reusability than the existing them by analyzing those measurement results.

A Study on Energy Efficiency Improvement of LDC Recycling Load Tester (LDC 재생형 부하 시험기의 효율 개선에 관한 연구)

  • Lee, Choon-il;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.86-92
    • /
    • 2016
  • A high-capacity battery installed in a hybrid vehicle or electric vehicle is used to power, or as a power supply for, electric sub-assemblies. In order to use a high-capacity battery as a power supply for electric sub-assemblies, such as an electronic control unit or for lighting, radio, and navigation, there is a need for a DC converter that changes a high voltage of 240-400V to a low voltage of 12-14V, which is done with a low-voltage DC-DC converter (LDC). An LDC undergoes long-term aging so as to reduce latent defects in the production process. With regard to the usual aging method, an LDC is a DC-DC converter. So, a DC power supply is connected and used as input, and a programmable DC electronic load is the output. For stable operation, a product having a larger capacity by 10% (compared to an LDC) is used, and has a structure where electric power is dissipated into 100% heat. So, there is a problem with volume, based on the use of two pieces of equipment to test the LDC, and another problem based on the generation of heat in the programmable DC electronic load. Hence, this paper suggests a load test method as a way of recycling, where a significant portion of the electricity dissipated as heat in a load tester is returned as input. The method realizes savings of 80% or more in the electricity dissipated as heat through improvement in the efficiency of the recycling load tester.

Analytical Study on the Seismic Retrofit Method of Irregular Piloti Building Using Knee-Brace (Knee - Brace를 활용한 비정형 필로티 건물의 내진보강방안에 대한 해석적 연구)

  • Yoo, Suk-Hyung;Kim, Dal-Gee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.35-42
    • /
    • 2020
  • Torsional behavior due to the plane irregularities of the piloti building can cause excessive story drift in the torsionally outermost column, which can lead to shear failure of the column. As a seismic retrofit method that can control the torsional behavior of the piloti building, the expansion of RC wall, steel frame or steel brace may be used, but such methods may hinder the openness of the piloti floor. Therefore, in this study, linear dynamic analysis and nonlinear static analysis for piloti buildings retrofitted by knee brace were performed, and seismic performance evaluation and torsion control effect of knee brace were analyzed. The results showed that the shear force of the column increased when the piloti building retrofitted by knee brace, but it was effective in controlling the torsional deformation. In case of retrofit between knee brace and column by 30°, the shear force of the column increased less than that of 60°, and the lateral displacement of column was decreased in the order of □, ◯ and H in cross-section.

The effect of tulobuterol patches on the respiratory system after endotracheal intubation

  • Lee, Do-Won;Kim, Eun-Soo;Do, Wang-Seok;Lee, Han-Bit;Kim, Eun-Jung;Kim, Cheul-Hong
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.4
    • /
    • pp.265-270
    • /
    • 2017
  • Background: Endotracheal intubation during anesthesia induction may increase airway resistance ($R_{aw}$) and decrease dynamic lung compliance ($C_{dyn}$). We hypothesized that prophylactic treatment with a transdermal ${\beta}2$-agonist tulobuterol patch (TP) would help to reduce the risk of bronchospasm after placement of the endotracheal tube. Methods: Eighty-two American Society of Anesthesiologists (ASA) category I or II adult patients showing obstructive patterns were divided randomly into a control and a TP group (n = 41 each). The night before surgery, a 2-mg TP was applied to patients in the TP group. Standard monitors were recorded, and target controlled infusion (TCI) with propofol and remifentanil was used for anesthesia induction and maintenance. Simultaneously, end-tidal carbon dioxide, $R_{aw}$, and $C_{dyn}$ were determined at 5, 10, and 15 min intervals after endotracheal intubation. Results: There was no significant difference in demographic data between the two groups. The TP group was associated with a lower $R_{aw}$ and a higher $C_{dyn}$, as compared to the control group. $R_{aw}$ was significantly lower at 10 min (P < 0.05) and 15 min (P < 0.01), and $C_{dyn}$ was significantly higher at 5 min (P < 0.05) and 15 min (P < 0.01) in the TP group. A trend towards a lower $R_{aw}$ was observed showing a statistically significant difference 5 min after endotracheal intubation (P < 0.01) in each group. Conclusions: Prophylactic treatment with TP showed a bronchodilatory effect through suppressing an increase in $R_{aw}$ and a decrease in $C_{dyn}$ after anesthesia induction without severe adverse effects.

Studies on the Characteristics of Rubber Vulcanization Exotherm by Differential Scanning Calorimetry. (Differential Scanning Calorimetry에 의(依)한 고무의 가황발열특성(加黃發熱特性)에 관(關)한 연구(硏究))

  • Choi, Sei-Young;Paik, Nam-Chul
    • Elastomers and Composites
    • /
    • v.19 no.1
    • /
    • pp.13-31
    • /
    • 1984
  • The purposes of this dissertation are to demonstrate that DSC theromoanaytical methods of vulcanization can provide useful informations on the vulcanization characteristics of industrial formulations and also provides the potential basis for a rapid and complete method of sulfur and vulcanizing accelerator analysis for quality control. The influences of those factors such as heating rate, scan temperature, vucanizing accelerator's type and concentration upon vulcanization exotherm in NR and NBR compounds in the presence of vulcanizing accelerators such as TMTD,MBTS,DPG,TMTM,CBS, and MBT were evaluated by means of DSC. In order to examine the credibility in the DSC method, the same samples which were used for DSC method were studied to compare the DSC results with the ODR (Oscillating Disk Rheometer) data. The results obtained were as follows 1. In the DSC dynamic experiments, the observed enthalpy results from vulcanization depends upon the heating rate; In the range of 2 to $20^{\circ}C/min$ of heating rate, as the heating rate was increased the enthalpy change was also increased. However, over the heating rate of $30^{\circ}C/min$ it was observed that the enthalpy change was decreased as the heating rate was further increased. Without regard to the change of enthalpy, tremendous instantaneous heat evolving was observed in the range of high heating rates. 2. For the samples which are added with various vulcanizing accelerators, the activation energies of vulcanization were as follows; 3. Regarding to the influences of vulcanizining accelerator's types upon the characteristics of vulcanization exotherm, NR and NBR compounds in the presence of thiuramsulphide compounds type accelerators such as TMTD, TMTM, were exhibited sharper and higher vulclanization exotherm than others. From the resuts of DSC thermograms which was distributed in even shape in the broad temperature range, it was clearly shown that the guanidine compounds type accelerator such as DPG acts as a delayed acting accelerator. 4. In the comparison of DSC and ODR results, the dependency of temperature in the cure rate and the observed conversions show good agreements between two results. 5. In the same curatives, by the comparison of glass transition temperatures, it was possible to predict relative values of maximum torques. Consequently, from the present studies, it is shown that the DSC thermoanalytical method can provide an alternate new method for rapid and complete quality control analysis of rubber industry.

  • PDF

Seismic Capacity Evaluation of Existing Medium-and low-rise R/C Frame Retrofitted by H-section Steel Frame with Elastic Pad Based on Pseudo-dynamic testing (유사동적실험에 의한 탄성패드 접합 H형 철골프레임공법으로 보강 된 기존 중·저층 R/C 골조의 내진성능 평가)

  • Kim, Jin-Seon;Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.83-91
    • /
    • 2021
  • In this study, to improve the connection performance between the existing reinforced concrete (R/C) frame and the strengthening member, we proposed a new H-section steel frame with elastic pad (HSFEP) system for seismic rehabilitation of existing medium-to-low-rise reinforced concrete (R/C) buildings. This HSFEP strengthening system exhibits an excellent connection performance because an elastic pad is installed between the existing structure and reinforcing frame. The method shows a strength design approach implemented via retrofitting, to easily increase the ultimate lateral load capacity of R/C buildings lacking seismic data, which exhibit shear failure mechanism. Two full-size two-story R/C frame specimens were designed based on an existing R/C building in Korea lacking seismic data, and then strengthened using the HSFEP system; thus, one control specimen and one specimen strengthened with the HSFEP system were used. Pseudodynamic tests were conducted to verify the effects of seismic retrofitting, and the earthquake response behavior with use of the proposed method, in terms of the maximum response strength, response displacement, and degree of earthquake damage compared with the control R/C frame. Test results revealed that the proposed HSFEP strengthening method, internally applied to the R/C frame, effectively increased the lateral ultimate strength, resulting in reduced response displacement of R/C structures under large scale earthquake conditions.