Correction of Pseudo-Dynamic Test by Equivalent Energy Compensation (등가에너지 보상을 통한 유사동적 실험의 보정)

  • Kim, Nam Sik;Lee, Sang Soon;Chung, Woo Jung;Lee, Dong Guen
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4_1
    • /
    • pp.77-85
    • /
    • 1992
  • The Pseudo-dynamic test is a new experimental technique for simulating the earthquake response of structures or structural components in the time domain. It is especially efficient for testing specimens that are too large, heavy or strong to be tested on a shaking table. But, in general, the responses obtained in the Pseudo-dynamic test can be distorted by the experimental errors inevitably during control and measurement procedures. The studies are to investigate the effects of the experimental errors on the Pseudo-dynamic responses and apply a correction method to the Pseudo-dynamic testing algorithm. It is shown that the corrected responses using the equivalent energy compensation method are in a good correlation with the theoretical ones. Thus, the corrected Pseudo-dynamic responses could be reliable for evaluating the seismic performance of structural systems.

  • PDF

Design of High-resolution Wide-angle Lenz Module, and Image Distortion Compensation for Smart NUX (스마트 NUX용 고해상도 광각렌즈모듈 및 영상왜곡보정 설계)

  • Lee, Jae-Gon;Kang, Min-Goo;Kim, Won-Kyu;Lee, Kyung-Taek
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.5
    • /
    • pp.999-1004
    • /
    • 2012
  • In this paper, camera modules and lens's images were analyzed for the compensation of distortion image by wide angle lens based WDR(Wide Dynamic Range) with high resolution sensor(2-Mega CMOS Image sensor). Due to wide angle ($176^{\circ}$) of designed wide angle camera modules, the compensation result of distorted image was analyzed, and the application of these modules was proposed for smart NUX(Natural User eXprience).

An improved approach to evaluate the compaction compensation grouting efficiency in sandy soils

  • Xu, Xiang-Hua;Xiang, Zhou-Chen;Zou, Jin-Feng;Wang, Feng
    • Geomechanics and Engineering
    • /
    • v.20 no.4
    • /
    • pp.313-322
    • /
    • 2020
  • This study focuses on a prediction approach of compaction compensation grouting efficiency in sandy soil. Based on Darcy's law, assuming that the grouting volume is equal to the volume of the compressed soil, a two-dimensional calculation model of the compaction compensation grouting efficiency was improved to three-dimensional, which established a dynamic relationship between the radius of the grout body and the grouting time. The effectiveness of this approach was verified by finite element analysis. The calculation results show that the grouting efficiency decreases with time and tends to be stable. Meanwhile, it also indicates that the decrease of grouting efficiency mainly occurs in the process of grouting and will continue to decline in a short time after the completion of grouting. The prediction three-dimensional model proposed in this paper effectively complements the dynamic relationship between grouting compaction radius and grouting time, which can more accurately evaluate the grouting efficiency. It is practically significant to ensure construction safety, control grouting process, and reduce the settlement induced by tunnel excavation.

Average Current Mode Control for LLC Series Resonant DC-to-DC Converters

  • Park, Chang Hee;Cho, Sung Ho;Jang, Jinhaeng;Pidaparthy, Syam Kumar;Ahn, Taeyoung;Choi, Byungcho
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.40-47
    • /
    • 2014
  • An average current mode control scheme that consistently offers good dynamic performance for LLC series resonant DC-to-DC converters irrespective of the changes in the operational conditions is presented in this paper. The proposed control scheme employs current feedback from the resonant tank circuit through an integrator-type compensation amplifier to improve the dynamic performance and enhance the noise immunity and reliability of the feedback controller. Design guidelines are provided for both current feedback and voltage feedback compensation. The performance of the new control scheme is demonstrated through an experimental 150 W converter operating with 340 V to 390 V input voltage to provide a 24 V output voltage.

Controller Design for Dynamic Voltage Restorers by use of PQR Power Theory II - Determine The Compensation Voltages (PQR 순시전력이론에 의한 Dynamic Voltage Restorer의 제어기 설계 II -보상전 압의 결정)

  • Kim H.S.;Lee S.J.;Sul S.K.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.404-409
    • /
    • 2003
  • This paper discusses how to generate the reference compensation voltages in Dynamic Voltage Restorers (DVR) by use of PQR power theory Sensed three-phase terminal voltages are transformed to PQR coordinates without time delay. Since the reference voltages in PQR coordinates are do values, the voltage controller for DVRs is simple and easy to design. Proposed control method can be implemented by feedforward controllers or by feedback controllers. This paper verified the theory in the feedforward controller of a DVR by experiments.

  • PDF

A method of dynamic error reduction for a sensor with first order lag using a digital convolution integrator

  • Kubota, Nobuhisa;Mine, Katsutoshi;Doi, Masanori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.530-533
    • /
    • 1993
  • This paper describes a new method of dynamic error compensation, using a digital convolution integrator and two digital low pass filters. In this method, the process of compensation consists of three steps. First, sampling and digitizing of input signal, second, removing the noise in sampled data by the low pass filter and third, making a convolution integral using the output data of low pass filters. This method showed a good experimental result of reducing dynamic error even if there was a slight noise in the input signal. As a result, the detecting time constant of resistance thermo-bulb was improved to about 1/10th.

  • PDF

Characteristics and Dynamic Compensation Modeling of Liquid-Based Tilt Sensor (액체저항경사계의 특성과 동적모델링)

  • Song, Mu-Seok;Ahn, Ja-Il
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.2 s.140
    • /
    • pp.73-79
    • /
    • 2005
  • The characteristics of a tilt sensor utilizing the resistance change of an electrolyte associated with inclination is investigated, and a dynamic compensation modeling is proposed to make the real-time measurement of the absolute slope possible even with sporadically dynamic motion. Although the proposed system is small, economical and accurate for quasi-steady slope measurement, since it contains a freesurface the evolution of the liquid surface that has no direct relation to the real slope must be excluded for any rapid rotations or translations. For various artificial motions the response of the sensor is analyzed and simplified modeling equations are proposed.

Application of Compensation Method of Motion Analysis Error Using Displacement Dependency between Anatomical Landmarks and Skin Markers Due to Soft Tissue Artifact (연조직 변형에 의한 해부학적 지표와 피부마커의 변위 상관성을 이용한 동작분석 오차 보정 방법의 적용)

  • Ryu, Taebeum
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.4
    • /
    • pp.24-32
    • /
    • 2012
  • Of many approaches to reduce motion analysis errors, the compensation method of anatomical landmarks estimates the position of anatomical landmarks during motion. The method models the position of anatomical landmarks with joint angle or skin marker displacement using the data of the so-called dynamic calibration in which anatomical landmark positions are calibrated in ad hoc motions. Then the anatomical landmark positions are calibrated in target motions using the model. This study applies the compensation methods with joint angle and skin marker displacement to three lower extremity motions (walking, sit-to-stand/stand-to-sit, and step up/down) in ten healthy males and compares their performance. To compare the performance of the methods, two sets of kinematic variables were calculated using different two marker clusters, and the difference was obtained. Results showed that the compensation method with skin marker displacement had less differences by 30~60% compared to without compensation. And, it had significantly less difference in some kinematic variables (7 of 18) by 25~40% compared to the compensation method with joint angle. This study supports that compensation with skin marker displacement reduced the motion analysis STA errors more reliably than with joint angle in lower extremity motion analysis.

Dynamic Voltage Restorer (DVR) for 6.6[kV]/60[Hz] Power Distribution System Using Two Quasi Z-Source AC-AC Converters (두 개의 Quasi Z-소스 AC-AC 컨버터에 의한 6.6[kV]/60[Hz] 배전계통의 동적 전압 보상기(DVR))

  • Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.199-208
    • /
    • 2012
  • This paper proposes a quasi Z-source DVR(Dynamic Voltage Restorer) system with a series connection of the output terminals, to compensate the voltage variations in the 6.6[kV]/60[Hz] power distribution system. The conventional DVR using one quasi Z-source AC-AC converter has the advantage which it can compensate the voltage variations without the need for the additional energy storage device such as a battery, but it is impossible to compensate for the 50[%] under voltage sags. To solve this problem, a DVR system using two quasi Z-source AC-AC converters with the series connection of the output terminals is proposed. By controlling the duty ratio D in the buck-boost mode, the proposed system can control the compensation voltage. For case verification of the proposed system, PSIM simulation is achieved. As a result, in case that the voltage sags-swells occur 10[%], 20[%], 60[%] in power distribution system, and, in case that the 50[%] under voltage sags-swells continuously occur, all case could compensate by the proposed system. Especially, the compensated voltage THD was examined under the condition of the 10[%]~50[%] voltage sags and the 20[${\Omega}$]~100[${\Omega}$] load changes. The compensated voltage THD was worse for the higher load resistances and more severe voltage sags. Finally, In case of the voltage swells compensation, the compensation factor has approached nearly 1 regardless of the load resistance changes, while the compensation factor of voltage sags was related to the load variations.

Comparative Study on Transient Stability Improving Capability of Series and Shunt Compensation (비용함수에 의한 직병렬보상장치의 과도안정도 향상 특성 비교)

  • Choi, Kyu-Hyoung;Jeoug, Chang-Yang;Oh, Tae-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.655-657
    • /
    • 1996
  • The objective of this paper is to compare the series and shunt approaches of controlled reactive power compensation to improve power system transient stabilities. Including main circuit considerations of series and shunt compensators, application aspects are thought to have major impacts on efficiency and economy of the installation of the compensators. The concept is studied by means of EMTP simulations on one machine-Infinite Bus Test System which consists of a 612MVA steam turbin generator and transformer and double circuit 345KV transmission line. Idealized dynamic models of Thyristor Controlled Series Compensation and Shunt Compensation are used for the comparative study of the series and shunt compensation approach to damp power system oscillations.