• Title/Summary/Keyword: dynamic characterization

Search Result 299, Processing Time 0.028 seconds

Integrated reservoir characterization for fractured reservoir using static and dynamic data

  • Park Jae-Hyun;Lee Ho-Seop;Nam Sang-Ho;Sung Won-Mo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.716-718
    • /
    • 2003
  • For the successful characterization of the fractured reservoir, it is inevitable to describe fracture properties more precisely. Although the deterministic features, of mega-trend faults can be relatively definite, the background features of minor fractures are not easily analysed in spite of the various data of these features. In this study, two different methods, statistical and fractal methods, are used to construct the minor fracture system over the entire field. After completing these tasks, with the identified deterministic features and background features, total fracture system for fractured reservoir is constructed and updated with the aid of dynamic data obtained from well test.

  • PDF

Design and Characterization of Fiber Optical Coupler for Acoustic and Vibration Measurements (음향/진동 측정을 위한 광섬유 결합기의 설계 및 특성실험)

  • Kwon, Hyu-Sang;Kim, Kyong-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.9 s.114
    • /
    • pp.971-981
    • /
    • 2006
  • This paper presents the design and characterization of a novel fiber optical coupler for intensity modulated fiber optical microphone. Theoretical equations for the optical power coupling are presented in detail including optical path analysis and misalignment. Various optical couplers are simulated and manufactured. A multi-mode to multi-mode coupler is characterized by static and dynamic movements of mirror on a well designed experimental stage.

A Dynamic Characterization of Long Span Bridge Using Mean FRF (평균FRF를 이용한 장대교량의 동특성)

  • Heo, Gwang-Hee;Choi, Man-Yong;An, Byung-lk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.1
    • /
    • pp.77-83
    • /
    • 2000
  • 구조물의 동특성은 대형구조물을 상시감시 할 수 있는 장점으로 인하여 널리 활용된다. 상시감시를 위해 계측된 랜덤 데이터는 FFT를 통한 구조물의 동적 고유특성을 분석함으로써 이루어진다. 이 과정에서 Input Data와 Response Data사이에서 FFT Analyzer를 통하여 FRF가 측정된다. 특히 랜덤 데이터의 계측은 여건과 환경에 따라 발생하는 Noise로부터 가능한 정확한 FRF를 계측해야만 성공적인 구조물의 고유의 동적특성을 파악하게 된다. 랜덤 데이터에서 발생할 가능성이 높은 입력, 출력 Noise를 동시에 최소화 할 수 있는 새로운 개념의 FRF측정 알고리즘을 제안한다. 이 알고리즘에 의하여 장대형 모형교량으로부터 Modal 실험을 수행하여 계측된 동특성을 FE 해석 결과와 비교 평가하여 유용성을 제시한다.

  • PDF

Characterization of Primary Dynamic Resistance in Resistance Spot Welding (저항 점 용접의 1차 동저항 특성에 관한 연구)

  • 조용준;이세헌;신현일;배경민
    • Journal of Welding and Joining
    • /
    • v.17 no.2
    • /
    • pp.97-103
    • /
    • 1999
  • The dynamic resistance monitoring in primary circuit is one of the important issues. Because in-process and real time quality assurance of resistance spot weld is needed to increase the product reliability. In this study, new dynamic resistance detecting method is proposed as a practical manner of weld quality assurance using instantaneous current and voltage measured at the primary circuit. and also, various patterns of primary dynamic resistance curve are characterized with the macro photograph and the weldability lobe curve. It is found that the primary dynamic resistance patterns are basically similar to those of the secondary, but there is evident advantage such as no extra devices are needed to obtain the quality information and eventually real time feedback control will be possible.

  • PDF

Seismic Response Characterization of Shear Wall in Auxiliary Building of Nuclear Power Plant (지진에 의한 원전 보조건물 전단벽의동적 응답 특성 추정)

  • Rahman, Md Motiur;Nahar, Tahmina Tasnim;Baek, Geonhwi;Kim, Dookie
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.93-102
    • /
    • 2021
  • The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.

The Role of Dynamic CT for the Differential Diagnosis of Solitary Pulmonary Nodule (고립성 폐결절의 감별진단에서 Dynamic CT의 역할)

  • Chung, Jin-Hong;Park, Won-Jong;Cho, Ihn-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.2
    • /
    • pp.102-107
    • /
    • 2008
  • Background : Malignant pulmonary nodules account for 30 to 40 percent of all solitary pulmonary nodules (SPNs). Therefore, characterization of SPNs is very important for treatment. Recently, dynamic CT has been widely used for tissue characterization and formation of differential diagnoses. The purpose of this study was to evaluate the ability of dynamic CT to formulate the differential diagnosis of SPNs. Materials and Methods : Nineteen patients with SPNs underwent dynamic CT (unenhanced scans, followed by a series of images at 20, 40, 60, 80, 100, 120, 140, 160, and 180 sec after intravenous injection of contrast medium). Diagnosis of SPN was performed based on pathologic findings in needle biopsy samples. Peak enhancement, net enhancement, slope of enhancement, and maximum relative enhancement ratio of the SPN were measured on dynamic CT, and Levene's test was performed to assess benignancy and malignancy. Results : Twelve SPNs were confirmed to have malignant pathology. There were no significant differences between benign and malignant nodules with respect to peak enhancement (p=0.787), net enhancement (p=0.135), or slope of enhancement (p=0.698). The maximal enhancement ratio was increased in malignancy compared to benignancy, but the difference was not statistically significant (p=0.094). Conclusion : In our study, the hemodynamic characteristics of dynamic CT were not significantly different between benign and malignant nodules. Therefore, long-term studies of larger patient samples are required to confirm our findings.

  • PDF

Hot Workability Characterization of Ti Alloys Using Dynamic Material Model (동적재료모델을 활용한 티타늄합금의 고온성형성 고찰)

  • Yeom J. T.;Hyun Y. T.;Na Y. S.;Park N. K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.301-304
    • /
    • 2001
  • Hot-compression tests were carried out to investigate the hot workability of Ti64 and Ti6246 alloys at different temperatures and strain rates. Processing maps were developed on the basis of the dynamic material model unifying the relationship among constitutive behavior, hot workability and microstructure development. Stable regions, defined on the basis of four stability criteria 0${\delta}log(m)/\frac{\bot}{\varepsilon})<0$, s<1 and ${\delta}log(s)/\frac{\bot}{\varepsilon})<0$, were found to be associated with dynamic recovery and recrystallization.

  • PDF

Advanced Methods in Dynamic Contrast Enhanced Arterial Phase Imaging of the Liver

  • Kim, Yoon-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.1-16
    • /
    • 2019
  • Dynamic contrast enhanced (DCE) magnetic resonance (MR) imaging plays an important role in non-invasive detection and characterization of primary and metastatic lesions in the liver. Recently, efforts have been made to improve spatial and temporal resolution of DCE liver MRI for arterial phase imaging. Review of recent publications related to arterial phase imaging of the liver indicates that there exist primarily two approaches: breath-hold and free-breathing. For breath-hold imaging, acquiring multiple arterial phase images in a breath-hold is the preferred approach over conventional single-phase imaging. For free-breathing imaging, a combination of three-dimensional (3D) stack-of-stars golden-angle sampling and compressed sensing parallel imaging reconstruction is one of emerging techniques. Self-gating can be used to decrease respiratory motion artifact. This article introduces recent MRI technologies relevant to hepatic arterial phase imaging, including differential subsampling with Cartesian ordering (DISCO), golden-angle radial sparse parallel (GRASP), and X-D GRASP. This article also describes techniques related to dynamic 3D image reconstruction of the liver from golden-angle stack-of-stars data.

Dynamic Characterization of Passive Flow-Rate Regulator Using Pressure-Dependent Autonomous Deflection of Parallel Membrane Valves (압력에 따른 평행박막 밸브의 자율 변형을 이용한 수동형 유량 제어기의 동적특성 평가)

  • Doh, Il;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.825-829
    • /
    • 2011
  • We performed a dynamic characterization of passive flow-rate regulators, which compensate for inlet pressure variation and maintain a constant flow rate for precise liquid control in microfluidic systems. To measure the flow rate for a short time, much less than the period of the dynamic inlet pressure, we use the particle image velocimetry (PIV) method. DI water containing fluorescent beads with a $0.7-{\mu}m$ diameter was supplied to the flow-rate regulators, and two successive images of the particles were taken by a pulse laser and a fluorescent microscope to measure the flow velocity. For a dynamic inlet pressure of frequency 60 Hz, the flow velocity was constant with an average of 0.194 ${\pm}$ 0.014 m/s as the inlet pressure varied between 20 kPa to 50 kPa. The flow-rate regulators provided a constant flow rate of $5.82{\pm}0.29\;{\mu}l/s$ in the frequency range of the inlet pressure from 1 Hz to 60 Hz.

Dynamic and static structural displacement measurement using backscattering DC coupled radar

  • Guan, Shanyue;Rice, Jennifer A.;Li, Changzhi;Li, Yiran;Wang, Guochao
    • Smart Structures and Systems
    • /
    • v.16 no.3
    • /
    • pp.521-535
    • /
    • 2015
  • Vibration-based monitoring is one approach used to perform structural condition assessment. By measuring structural response, such as displacement, dynamic characteristics of a structure may be estimated. Often, the primary dynamic responses in civil structures are below 5 Hz, making accurate low frequency measurement critical for successful dynamic characterization. In addition, static deflection measurements are useful for structural capacity and load rating assessments. This paper presents a DC coupled continuous wave radar to accurately detect both dynamic and static displacement. This low-cost radar sensor provides displacement measurements within a compact, wireless unit appropriate for a range of structural monitoring applications. The hardware components and operating mechanism of the radar are introduced and a series of laboratory experiments are presented to assess the performance characteristics of the radar. The laboratory and field experiments investigate the effect of factors such as target distance, motion amplitude, and motion frequency on the radar's measurement accuracy. The results demonstrate that the radar is capable of both static and dynamic displacement measurements with sub-millimeter accuracy, making it a promising technology for structural health monitoring.