• 제목/요약/키워드: dynamic analysis of tall building

검색결과 84건 처리시간 0.025초

Field Measurements of the New CCTV Tower in Beijing

  • Xu, Y.L.;Zhan, S.;Xia, H.;Xia, Y.;Zhang, N.
    • 국제초고층학회논문집
    • /
    • 제2권3호
    • /
    • pp.171-178
    • /
    • 2013
  • The emergence of a growing number of tall buildings, often with unusual shapes and innovative structural systems, has led to the realization of the need for and the importance of field measurements. The new China Central Television (CCTV) Tower in Beijing is one of tall buildings with a highly unusual shape and a complex structural system, requiring field measurements to identify its dynamic characteristics for the subsequent dynamic analysis of the tower under wind excitation, seismic-induced ground motion and traffic-induced ground motion. The structural system and the finite element model of the CCTV Tower are first introduced in this paper. The computed natural frequencies and mode shapes are then presented as a reference for the field measurement. After introducing the arrangement of the ambient vibration measurement, the field measured natural frequencies and damping ratios of the CCTV Tower are presented and the measured natural frequencies are finally compared with the computed ones. It was found that the structural damping ratios of the CCTV Tower are small and the computed natural frequencies are smaller than the measured ones by about 12~17%.

점탄성 감쇠기가 설치된 고층건물의 효율적인 동적 해석 (Efficient Dynamic Analysis of Tall Buildings with Viscoelastic Dampers)

  • 김상태;홍성일;이동근
    • 한국지진공학회논문집
    • /
    • 제1권3호
    • /
    • pp.11-19
    • /
    • 1997
  • 본 논문은 점탄성 감쇠기가 설치된 고층건물의 효율적인 동적 해석방법에 대한 연구이다. 점탄성 감소기가 건물의 진동을 적절히 제어하기 위하여 사용되고 있으며 이러한 점타성 감쇠기가 설치된 건물의 동적거동을 예측하기 위하여 적절한 해석방법이 필요하다. 해석의 효율성을 높이기 위해서 강막가정과 행렬의 응축기법을 적용할 수 있는데, 점탄성 감쇠가가 설치된 건물은 강막가정을 고려한 행렬의 응축기법을 쉽게 적용할 수 없다. 따라서 제안된 해석방법에 감쇠행렬의 새로운 응축방법을 사용하였다. 그리고 예제 건물의 해석을 통하여 해석방법의 정확한 효율성에 대하여 살펴 보았다.

  • PDF

Study on Integrity Assessment of Pile Foundation Based on Seismic Observation Records

  • KASHIWA, Hisatoshi
    • 국제초고층학회논문집
    • /
    • 제9권4호
    • /
    • pp.369-376
    • /
    • 2020
  • Given the importance of quickly recovering livelihoods and economic activity after an earthquake, the seismic performance of the pile foundation is becoming more critical than before. In order to promote seismic retrofit of the pile foundations, it is necessary to develop a method for evaluating the seismic performance of the pile foundation based on the experimental data. In this paper, we focus on the building that was suffered severe damage to the pile foundation, conduct simulation analyses of the building, and report the results of evaluating the dynamic characteristics when piles are damaged using a system identification method. As a result, an analysis model that can accurately simulate the behavior of the damaged building during an earthquake was constructed, and it was shown that the system identification method could extract dynamic characteristics that may damage piles.

Engineering of Guangzhou International Finance Centre

  • Kwok, Michael;Lee, Alexis
    • 국제초고층학회논문집
    • /
    • 제6권1호
    • /
    • pp.49-72
    • /
    • 2017
  • The Guangzhou International Finance Centre (IFC) is a landmark building that symbolizes the emerging international strength of Guangzhou, China's third largest city. It is also one of the dual iconic towers along the main axis of Guangzhou Zhujiang New Town. Arup adopted a total engineering approach in embracing sustainability and aiming at high efficiency solutions based on performance-based design principles covering structures, building services, fire engineering, vertical transportation, and façade performance to constitute an efficient and cost-effective overall building design. Through dynamic integration of architectural and engineering principles, Guangzhou IFC represents a pioneering supertall building in China. It adopts a diagrid exoskeleton structural form that is clearly expressed through the building's façade and gives the building its distinctive character. The aerodynamic shape of the building not only presents the aesthetic quality of elegant simplicity, but also reduces the effects of wind, thereby reducing the size and weight of the structure. State-of-the-art advanced engineering methods, such as optimization techniques and nonlinear finite element modelling, were applied in parallel with large-scale experimental programs to achieve an efficient and high-performance design taking into account the constructability and cost-effectiveness for a project of this scale.

연속체 모델과 지하구조물 고정단 모델의 비교를 통한 SSI 해석의 타당성 연구 (A validity study on SSI analysis by comparing the complete system model and the underground structure fixed-end model)

  • 유광호;김승진
    • 한국터널지하공간학회 논문집
    • /
    • 제20권5호
    • /
    • pp.757-772
    • /
    • 2018
  • 최근 경주 포항 등 대도시에서 지진이 발생하고 이에 각 분야에서의 내진해석 연구가 활발히 진행되고 있다. 하지만 대부분의 기존 내진해석은 지상구조물과 지반을 따로 다루었기 때문에 지반과 구조물의 완전한 상호 동적거동에 대한 연구가 부족한 실정이다. 따라서 본 연구에서는 건물만 고려하는 지하구조물 고정단 모델과 건물과 지반을 함께 고려하는 연속체 모델을 각각 적용하기 위해 MIDAS GEN 및 MIDAS GTS NX를 이용하여 민감도 분석을 수행하고 SSI를 고려한 동적해석의 타당성을 살펴보았다. 연구 결과, 대부분의 조건에서 지하구조물 고정단 모델이 연속체 모델보다 초고층 건물의 최대 순수 수평변위를 더 작게, 휨응력을 더 크게, 또한, 취약부의 범위는 더 작게 산출하는 것으로 나타났다. 따라서 내진해석 시 지반-구조물 상호작용을 고려한 연속체 모델을 사용하는 것이 보다 타당할 것으로 판단된다.

Simplified finite element modelling of non uniform tall building structures comprising wall and frame assemblies including P-Δ effects

  • Belhadj, Abdesselem Hichem;Meftah, Sid Ahmed
    • Earthquakes and Structures
    • /
    • 제8권1호
    • /
    • pp.253-273
    • /
    • 2015
  • The current investigation has been conducted to examine the effect of gravity loads on the seismic responses of the doubly asymmetric, three-dimensional structures comprising walls and frames. The proposed model includes the P-${\Delta}$ effects induced by the building weight. Based on the variational approach, a 3D finite element with two nodes and six DOF per node including P-${\Delta}$ effects is formulated. Dynamic and static governing equations are derived for dynamic and buckling analyzes of buildings braced by wall-frame systems. The influences of P-${\Delta}$ effects and height of the building on tip displacements under Hachinohe earthquake record are investigated through many structural examples.

국내 고층건물의 RD법에 의한 감쇠율의 진폭의존성 (Amplitude dependent damping ratio of domestic tall building by RD method)

  • 윤성원
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.89-95
    • /
    • 2004
  • The measured damping ratio was analysed to obtain amplitude dependence. Wind-induced vibration of 20 story steel-framed building was measured to investigate amplitude dependence by RD method. Micro-tremo vibrations of 20 RC bearing wall typed buildings were performed to analysis the amplitude dependence by formula proposed by Tamua and ESDU. Amplitude dependent damping in 17 story steel-framed building was showed clearly in the increasing rate of 9%. But Amplitude dependent damping of 17 RC bearing wall typed buildings was very low in the increasing rate of 2.5%. The tendency of dynamic properties of building obtained here are useful for the validation of dynamic properties of buildings in the evaluation of serviceability.

  • PDF

A New Paradigm for Wind Design

  • M. Burton;M. Tatarsky;I. Ashcroft
    • 국제초고층학회논문집
    • /
    • 제11권4호
    • /
    • pp.363-368
    • /
    • 2022
  • For taller buildings with unconventional architecture, refined structural systems or in geographical areas with high wind conditions, performance-based design can be seen as an enhanced design process and is either a supplement to, or alternative to a prescriptive code-based design. The ultimate goal of Performance-Based Wind Design (PBWD) is to result in a building that better addresses key goals of performance over the buildings full life cycle. Major innovations around the use of a PBWD approach include nonlinear dynamic analysis for wind design, limited inelasticity in the main wind force resisting system elements, and system-based performance criteria. This paper discusses potential considerations and benefits made when using a performance-based approach, in addition to the general practicality of use, for the structural design on a few key tall buildings.

The effect of RBS connection on energy absorption in tall buildings with braced tube frame system

  • Shariati, Mahdi;Ghorbani, Mostafa;Naghipour, Morteza;Alinejad, Nasrollah;Toghroli, Ali
    • Steel and Composite Structures
    • /
    • 제34권3호
    • /
    • pp.393-407
    • /
    • 2020
  • The braced tube frame system, a combination of perimeter frame and bracing frame, is one of the systems used in tall buildings. Due to the implementation of this system in tall buildings and the high rigidity resulting from the use of general bracing, providing proper ductility while maintaining the strength of the structure when exposing to lateral forces is essential. Also, the high stress at the connection of the beam to the column may cause a sudden failure in the region before reaching the required ductility. The use of Reduced Beam Section connection (RBS connection) by focusing stress in a region away from beam to column connection is a suitable solution to the problem. Because of the fact that RBS connections are usually used in moment frames and not tested in tall buildings with braced tube frames, they should be investigated. Therefore, in this research, three tall buildings in height ranges of 20, 25 and 30 floors were modeled and designed by SAP2000 software, and then a frame in each building was modeled in PERFORM-3D software under two RBS-free system and RBS-based system. Nonlinear time history dynamic analysis is used for each frame under Manjil, Tabas and Northridge excitations. The results of the Comparison between RBS-free and RBS-based systems show that the RBS connections increased the absorbed energy level by reducing the stiffness and increasing the ductility in the beams and structural system. Also, by increasing the involvement of the beams in absorbing energy, the columns and braces absorb less energy.

Collapse assessment and seismic performance factors in tall tube-in-tube diagrid buildings

  • Khatami, Alireza;Heshmati, Mahdi;Aghakouchak, Ali Akbar
    • Earthquakes and Structures
    • /
    • 제19권3호
    • /
    • pp.197-214
    • /
    • 2020
  • Diagrid structures have been introduced as a fairly modern lateral load-resisting system in the design of high-rise buildings. In this paper, a novel diagrid system called tube-in-tube diagrid building is introduced and assessed through pushover and incremental dynamic analyses. The main objectives of this paper are to find the optimum angle of interior and exterior diagrid tube and evaluate the efficiency of diagrid core on the probability of collapse comparing to the conventional diagrid system. Finally, the seismic performance factors of the proposed system are validated according to the FEMA P695 methodology. To achieve these, 36-story diagrid buildings with various external and internal diagonal angles are designed and then 3-D nonlinear models of these structures developed in PERFORM-3D. The results show that weight of steel material highly depends on diagonal angle of exterior tube. Adding diagrid core generally increases the over-strength factor and collapse margin ratio of tall diagrid buildings confirming high seismic safety margin for tube-in-tube diagrid buildings under severe excitations. Collapse probabilities of both structural systems under MCE records are less than 10%. Finally, response modification factor of 3.0 and over-strength factor of 2.0 and 2.5 are proposed for design of typical diagrid and tube-in-tube diagrid buildings, respectively.