• 제목/요약/키워드: dye visualization

검색결과 61건 처리시간 0.027초

기포탑 유동에서의 기포분율과 혼합정도의 상관관계 (Relationship between void fraction and mixing in bubble column flow)

  • ;이주범;박형민
    • 한국가시화정보학회지
    • /
    • 제15권1호
    • /
    • pp.41-46
    • /
    • 2017
  • Control of mixing and transport processes are the key areas that can be benefited by understanding the hydrodynamics in gas-liquid two-phase flows. In particular, the enhanced bubble-induced liquid-phase mixing is known to be a function of void fraction distribution, gas phase velocity and so on. To further our insight on the characteristics of the liquid-phase mixing induced by the bubbles, in the present study, we experimentally investigate the mixing performance of a rectangular bubble column while changing the void fraction from 0.006 to 0.075%. A shadowgraphy technique is used to measure the gas-phase properties such as void fraction and size/velocity of bubbles. On the other hand, we use dye visualization with low diffusive buoyant dye to directly measure the level of mixing. Finally, we confirm that the time taken for full mixing scales with the inverse of volume void fraction.

High-Fidelity Perforator Visualization for Cadaver Dissection in Surgical Training

  • AllenWei Jiat Wong;Yee Onn Kok;Khong Yik Chew;Bien Keem Tan
    • Archives of Plastic Surgery
    • /
    • 제50권6호
    • /
    • pp.621-626
    • /
    • 2023
  • In the first half of the third century B.C., Herophilus and Erasistratus performed the first systematic dissection of the human body. For subsequent centuries, these cadaveric dissections were key to the advancement of anatomical knowledge and surgical techniques. To this day, despite various instructional methods, cadaver dissection remained the best way for surgical training. To improve the quality of education and research through cadaveric dissection, our institution has developed a unique method of perforator-preserving cadaver injection, allowing us to achieve high-fidelity perforator visualization for dissection studies, at low cost and high efficacy. Ten full body cadavers were sectioned through the base of neck, bilateral shoulder, and hip joints. The key was to dissect multiple perfusing arteries and draining veins for each section, to increase "capture" of vascular territories. The vessels were carefully flushed, insufflated, and then filled with latex dye. Our injection dye comprised of liquid latex, formalin, and acrylic paint in the ratio of 1:2:1. Different endpoints were used to assess adequacy of injection, such as reconstitution of eyeball volume, skin turgor, visible dye in subcutaneous veins, and seepage of dye through stab incisions in digital pulps. Dissections demonstrated the effectiveness of the dye, outlining even the small osseous perforators of the medial femoral condyle flap and subconjunctival plexuses. Our technique emphasized atraumatic preparation, recreation of luminal space through insufflation, and finally careful injection of latex dye with adequate curing. This has allowed high-fidelity perforator visualization for dissection studies.

루버 핀을 지나는 공기의 유동특성에 대한 기초적 연구 (A Basic Study on Air Flow Characteristics in Louvered Fins)

  • 강창수;최태민
    • 대한기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.1276-1293
    • /
    • 1993
  • 본 연구는 위에서 언급된 모델보다 훨씬 폭이 큰 23.5mm 루버 핀형 방열기용 열교환기를 모델로 삼고, 레이놀즈수가 500 이하인 저 레이놀즈수(100, 300, 500), 루버 각(22˚,24˚,28˚) 및 핀 피치 와 루버 피치의 비 Fp /Lp(1.23, 1.5) 등의 변화 에 따른 핀 내부의 유동, 전열 특성 및 압력분포등의 영향을 유한차분법으로 수치해석 하였다. 또한 동일한 루버 핀에대해 13:1 모델을 제작하여 염료주입법에의한 유동의 가시화 실험을 하였으며, 그 결과를 수치해석 결과와 비교 검토하였다.

층류파형 액막의 유동특성에 관한 연구 (A study on the flow characteristics of laminar wavy film)

  • 김진태;이계한
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.628-636
    • /
    • 1997
  • Flow visualization technique incorporating photochromic dye is used to study the flow characteristics of the gravity driven laminar wavy film. The film thickness and wave speed are successfully measured by flow visualization. As the inclination angle increases, the waves have higher peaks and lower substrate thickness. The measured cross stream velocity at the free surface is up to 10% of stream wise velocity, which shows enhanced mixing in the lump of the film. The measured stream wise velocity profiles are close to parabolic profile near the substrate and the peak but show significant velocity defect near the rear side of the wave. The measured wall shear rate distributions show good agreement with the previous workers' numerical results.

Counterion-dye staining method for DNA in agarosegels using indoine blue and methyl orange

  • Hwang, Sun-Young;Jin, Li-Tai;Yoo, Gyurng-Soo;Choi, Jung-Kap
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.142.1-142.1
    • /
    • 2003
  • Sensitive and safe method for visualization of DNA in agarose gels using visible dye is described. To improve the sensitivity, we studied a counterion-dye staining method using methyl orange as a counterion-dye which contributes to reduce excessive background staining by indoine blue. Dye concentrations, PH of staining solution, mixing molar ratio of two dyes, and staining times were optimized for the counterion-dye staining. By the staining with a mixed solution of 0.005% indoine blue and 0.00165% methyl orange in 10% ethanol 0.2M sodium acetate, 8 ng of the 3 kb DNA in an agarose gel was detected within 1hr. (omitted)

  • PDF

마이크로 채널내 구조물 변경에 따른 교반특성 가시화 (Visualization of Stirring Characteristics in a Microchannel with Structures Changed)

  • 허형석;서용권
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.79-80
    • /
    • 2003
  • This paper presents experimental results on stirring characteristics in a microchannel with structures changed. We fabricated a new chaotic micro mixer and made by a RP(Rapid Rrototyping) technology. Flow visualization for the stirring effect was performed by using pure orator in a reservoir and fluorescent dye in the other. Chaotic mixing was achieved by introducing periodic perturbation in the field of the microchannel flow by means of shaped structures. It was found that the stirring is enormously enhanced at larger bock-height.

  • PDF

원형관 내에서 유동가시화 기법을 이용한 선회유동에 관한 연구고찰 (A Review on Swirling Flow by Using Flow Visualization Techniques in the Circular Tubes)

  • 장태현;도덕희;이권수
    • 한국가시화정보학회지
    • /
    • 제8권3호
    • /
    • pp.12-21
    • /
    • 2010
  • Swirling flows are found in very wide range of applications, for examples, cyclone separators, spraying machines, heat exchangers and jet pumps, ect. Relatively, little work has been done on the swirl flow using flow visualization techniques. This study deals with many visualization techniques to study on swirling flow. These techniques are related to oil films methods, smoke, dye liquids, liquid crystal, stroboscope light, smoke wire, white light, naphthalene sublimation, LDV(lase doppler Velocimetry) and PIV(particle image velocimetry). The present work has handled single, annular, carved tube, swirl expansion and swirl wake using several visualization methods in the vertical and horizontal circular tube.

판형-핀 열교환기 분배면의 유동 가시화 연구 (Flow Visualization Study around the Distributor of Plate-fin Heat Exchangers)

  • 정태식;박승하;김창수;김형범
    • 한국가시화정보학회지
    • /
    • 제10권3호
    • /
    • pp.37-41
    • /
    • 2012
  • Plate-fin heat exchanger is a kind of compact heat exchangers with a good performance in heat transfer. It is widely used in various engineering fields such as aerospace, chemical and biomedical industries. Quantitative and qualitative flow visualization study were performed using the water model of commercial plate-fin heat exchanger with header angles of $30^{\circ}$. The Reynolds number was 100. Conventional digital particle image velocimetry was used to measure the instantaneous velocity fields of the header region and the flow visualization using dye injection and hydrogen bubble method were applied to capture the qualitative flow characteristics. The results showed the existence of separation flow region at the junction area and the bottom wall of the exit region.

마이크로 레이저 형광 여기법을 이용한 미세채널 내부에서의 산소 확산에 대한 정량적 가시화 (Quantitative Visualization of Oxygen Transfer in Micro-channel using Micro-LIF Technique)

  • 천쥐안;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제10권1호
    • /
    • pp.34-39
    • /
    • 2012
  • In the present study, oxygen transfer process across gas-liquid interface in a Y-shape micro-channel is quantitatively visualized using the micro laser induced fluorescence (${\mu}$-LIF) technique. Diffusion coefficient of Oxygen ($D_L$) is estimated based on the experimental results and compared to its theoretical value. Tris ruthenium (II) chloride hexahydrate was used as the oxygen quenchable fluorescent dye. A light-emitting diode (LED) with wavelength of 450 nm was used as the light source and phosphorescence images of fluorescent dye were captured by a CMOS high speed camera installed on the microscope system. Water having dissolved oxygen (DO) value of 0% and pure oxygen gas were injected into the Y-shaped microchannel by using a double loading syringe pump. In-situ pixel-by-pixel calibration was carried out to obtain Stern-Volmer plots over whole flow field. Instantaneous DO concentration fields were successfully mapped according to Stern-Volmer plots and DL was calculated as $2.0675{\times}10^{-9}\;m^2/s$.

원형 이중관 내의 선회유동에 관한 실험적 연구 (An Experimental Study on Swirling flow in a Cylindrical Annuli)

  • 장태현;이권수;이해수;강창수
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.89-95
    • /
    • 2002
  • An experimental investigation was performed to study the characteristics of turbulent swirling flow in an axisymmetric annuli. The swirl angle measurements were performed by flow visualization technique using smoke and dye liquid. Using the Particle Image Velocimetry method, this study found the time-mean velocity distribution and turbulent intensity with swirl for Re = 20,000, 30,000, 50,000, and 70,000 along longitudinal sections and the results appear to be physically reasonable.

  • PDF