• Title/Summary/Keyword: dye leakage

Search Result 149, Processing Time 0.024 seconds

IN VITRO STUDY ON THE MARGINAL LEAKAGE OF THE CLASS V COMPOSITE RESTORATION WITH DENTAL ADHESIVE (치과용 접착제(Dental adhesive)를 사용한 제5급 복합레진수복물의 변연누출에 관한 실험적 연구)

  • Chung, Gun-Chul;Park, Dong-Soo;Lee, Chan-Young;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.135-144
    • /
    • 1984
  • This study was undertaken to evaluate the degree of the marginal leakage of composite restoration with 3 brands of dental adhesives by means of the dye penetration at the enamel and dentinal margins. 150 cavities of class V were prepared on the buccal and lingual surfaces of 75 extracted anterior and premolar teeth, which were devided into 3 groups. The cavities were filled with composite resin, Silar$^{(R)}$ (3M) and Heliosit$^{(R)}$ (Vivadent) after application of the dental adhesives, specifically Scotchbond$^{(R)}$ (3M) which is essentially composed with halophosphorus ester of Bis-GMA, Dentin Adhesit$^{(R)}$ (Vivadent) which is polyurethane resin, and Enamel Bond$^{(R)}$ (3M) which is a product of Bis-GMA with low viscosity at internal surfaces and margins of the cavities. All specimens were immersed in $37^{\circ}C$, 0.5% methylene blue solution for 24 hours after thermocycling at $4^{\circ}C$ and $60^{\circ}C$, embedded in acrylic resin, and sectioned with diamond disk into two parts. The sectioned specimens observed with the light microscope. The following results were obtained: 1. The group filled with Scotchbond$^{(R)}$-Silar$^{(R)}$ the other two groups at the enamel margins. 2. No significant difference in the degree of the marginal leakage had appeared between Dentin Adhesit$^{(R)}$-Heliosit$^{(R)}$ group an d Enamel Bond$^{(R)}$-Silar$^{(R)}$ group at the enamel margins. 3. Severe marginal leakage with penetration of dye to the floor of cavity had appeared from the all three groups and no significant difference in the degree of marginal leakage existed between the three groups at the dentinal margins.

  • PDF

APICAL SEALING OF THERMAFIL OBTURATORS IN CURVED CANALS (만곡근관에서 Thermafil의 근단폐쇄성에 관한 실험적 연구)

  • Ha, Joo-Hee;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.671-684
    • /
    • 1995
  • The purpose of this study was to compare the apical sealing ability, overfilling and obturation of lateral canals using two gutta-percha techniques: Thermafil obturators and cold lateral condensation. Eighty numbered epoxide blocks with one major and five lateral canals were divided into four experimental groups and obturated according to experimental groups. Four experimental groups were as follows: Group 1 : Filling with Thermafil plastic obturators and sealer(ThermaSeal) Group 2 : Filling with Thermafil plastic obturators only, without sealer(ThermaSeal) Group 3 : Fillng using lateral condensation with sealer(AH-26) Group 4 : Fillng using lateral condensation without sealer(AH-26) All the blocks were stored in 100% relative humidor at room temperature for 7 days. Each block was placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. Apical leakage was measured from the apical foramen to the most coronal level of dye penetration in millimeter under a stereoscope. The length of gutta-percha and sealer in each of the lateral canals was measured, too. The presence or absence of overfilling of gutta-percha and sealer was recorded. The data was analyzed by one-way ANOVA. The obtained results were as follows: l. Apical dye leakage was almost: not occurred in Group Willed with Thermafil and sealer) and Group 3(filled using lateral condensation with sealer), and there was no significant difference in linear leakage between two groups(p>0.01). 2. In both Thermafil and lateral condensation groups, linear leakage of Group I, 3(filled with sealer) was less than that of Group 2, 4(filled without sealer), and there was no significant difference in linear leakage between Group 1, 2, 3(p> 0.01). 3. Overfilling during obturation of Group 1, 2(filled with Thermafil) was more than Group 3, 4(filled using lateral condensation), and there was no significant difference between groups(p> 0.05). 4. Groups filled with Thermafil had significantly more gutta-percha than groups filled using lateral condensation in all lateral canals(p <0.01), the total length of gutta-percha and sealer found in all lateral canals were similar in Group 1 and Group 3.

  • PDF

MICROLEAKAGE OF CLASS V COMPOMER RESTORATIONS (5급 와동의 수복에 있어서 수종의 compomer의 미세 변연 누출에 관한 연구)

  • Yoo, Hyeon-Mee;Park, Dong-Sung;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.41-45
    • /
    • 2000
  • The purpose of this study was to evaluate the microleakage of compomers. In this in vitro study, class V cavities were prepared on buccal and lingual surfaces of thirty extracted human premolars and molars on cementum cervical margin. The experimental teeth were randomly divided into five groups of six samples (12 surfaces) each, Group 1 : Dyract AP, Group 2 : F2000 compomer(non-etch), Group 3 : F2000 compomer(etch), Group 4 : Elan, Group 5 : Compoglass. The bonding agents and compomer were applied for each group following the manufacturer's instructions. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 30 teeth were placed 1% methylene blue dye for 24 hours then rinsed with tab water. The specimens were embedded in clear resin, then sectioned buccolingually through the center of the restoration with a low speed diamond saw. The dye penetration on each of the specimen was observed with a stereomicroscope. The results of study were statistically analyzed using the Student-Newmann-Kaul' s Test. The results were obtained as follows. 1. All compomer restoration systems did not completely prevent marginal leakage. 2. In enamel margin, F2000 compomer(etch) group showed lower leakage value than other systems. Elan and Compoglass groups showed lower leakage value than Dyract AP and F2000 compomer(non-etch) groups (p<0.05). 3. In cementum margin, F2000 compomer(etch) and F2000 compomer (non-etch) groups showed lower leakage value than other systems. Dyract AP and Elan groups showed lower leakage value than Compoglass group (p<0.05).

  • PDF

SPECTROPHOTOMETRIC ANALYSIS ON THE SEALING EFFECT OF ULTRASONIC OBTURATION OF THE ROOT CANAL (초음파(超音波) 근관충진법(根管充眞法)의 폐쇄효과(閉鎖效果)에 관(關)한 분광광도계(分光光度界) 측정(測定))

  • Kim, Yang-Lag
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.46-57
    • /
    • 1990
  • The purpose of this study was to spectrophotometrically investigate the sealing effect of the ultrasonic canal obturation with softened gutta-percha utilizing an endosonic plugger by means of ultrasonic vibrations and heat. The 120 extracted human central and lateral incisors with single root were randomly selected, and the root canals were instrumented up to size #60 file by conventional method. The prepared canals were obtruated with gutta-percha by lateral condensation method, McSpadden technique and ultrasonic condensation method, with or without sealer. All specimens were immersed in 2% methylene blue in an incubator at $37^{\circ}C$ for 10 days. The teeth were then dissolved in 5ml of 60% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data statistically evaluated usint two-way ANOVA and Student's t-test. The results were as follows : No statistically significant difference in leakage was observed between the lateral condensation method and ultrasonic condensation method, with and without sealer. When sealer was used or not, McSpadden technique showed significantly greater leakage than lateral or ultrasonic condensation method. Statistical analysis of the data indicated that the canals obturated in conjunction with sealer demonstrated less dye leakage than the canals obturated without sealer(p<0.01), except McSpadden technique. The ultrasonic condensation method appeared comparable sealing ability to the lateral condensation method.

  • PDF

EFFECTS OF SMEAR LAYER AND DENTIN PRIMERS ON THE SEALING ABILITY OF ROOT CANAL (근관 밀폐도에 미치는 도말층 및 상아질 접착강화제의 영향)

  • Yang, Jin-Suck;Hwang, In-Nam;Kim, Won-Jae;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.527-535
    • /
    • 2000
  • The purpose of this study was to evaluate effects of smear layer and dentin primers on the sealing ability of root canals. 126 extracted human teeth with single, straight canals and mature apices were used. The Samples were first classified into six groups as follows: presence of smear layer; absence of smear layer; Scotchbond Bond Multi-Purpose; All Bond 2; Mac Bond 2; Clearfil Liner Bond 2. A Positive control was also established. All teeth except the control group were then obturated with thermoplasticized gutta-percha and AH26. Electrochemical and dye penetration technique were later used to evaluate the degree of micro leakage through the root canal. Seventy teeth were then immersed in a 1% potassium chloride solution and An external power supply(DC 10 V) was then applied to the circuit for the electrochemical microleakage test. The degree of Microleakage was determined over period of 28 days before being evaluated. In total, 48 teeth were submitted to the dye infiltration technique. All specimen were suspended in 2% methylene blue dye for 1 week before being longitudinally split. The degree of dye infiltration was measured under a stereo microscope at ${\times}10$ magnification and evaluated. The results were as follows: 1. Apical microleakage increased throughout the test period in all group and one group having a smear layer showed a dramatic increase under electrochemical test (p<0.05). In the group having smear layer, the degree of apical microleakage was the highest, and the micro leakage was much higher than in the smear layer removed group in electrochemical test (p<0.05). Scotchbond Multi-Purpose, All Bond 2, Mac Bond 2 and Clearfil Liner Bond 2 showed lower micro leakage than one group having smear layer. The All Bond 2 and Clearfil Liner Bond 2 treated groups showed the lowest microleakage in electrochemical test (p<0.05). 2. There was no significant difference between the experimental groups in dye penetration technique. These results suggested that the removal of the smear layer from root canal and concomitantly the application of dentin primer into root canal could improve the sealing ability of root canal obturation.

  • PDF

A COMPARATIVE STUDY ON THE APICAL LEAKAGE OF VARIOUS RETROFILLING MATERIALS (Retrofilling시 수종충전재료의 변연누출에 관한 연구)

  • Ohn, Yeong-Suck;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.118-125
    • /
    • 1991
  • Eighty - eight recently extracted teeth were used to evaluate the leakage characteristics of the following retrofilling materials; amalgam, zinc oxide eugenol cement, glass - ionomer cement, and cermet glass - ionomer cement. Root canals were prepared with step - back method and obturated with gutta percha and zinc oxide eugenol sealer. Root apex were resected 2 mm from apex and class I cavities were prepared with 2 mm or 4 mm depth. The cavities were filled with above materials. After application of varnish on all surface except resected surface, the roots were placed in 1 % methylene blue solution for 6 days. After longitudinal polishing to expose cental parts of filled materials, penetrated depths of dye were measured. The results were as follws. 1. As retrofilling material, glass ionomer cement filling groups showed less leakage than the other groups except zinc oxide eugenol cement filling group(p<0.01). 2. Amalgam filling groups had greater leakage than zinc oxide eugenol cement filling group(p<0.01). 3. 4 mm depth of retrofilled cavity had no effect on leakage characteristics compared with 2 mm depth cavity(p>0.05). 4. Glass ionomer cement and cermet glass ionomer cement filling groups showed less apical leakage than amalgam filling groups. But there was no statistical significance(p>0.05). 5. There was no difference in apical leakage between glass ionomer cement filling groups and cermet glass ionomer cement filling groups(p>0.05).

  • PDF

COMPARISON OF MARGINAL LEAKAGE OF CLASS 5 GIC RESTORATIONS ACCORDING TO CAVITY DESIGNS (와동 형태에 따른 5급 글라스 아이오노머 시멘트 수복물의 변연누출 비교)

  • Lee, Seon-Hwa;Hur, Bock;Lee, Hee-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.296-303
    • /
    • 1998
  • The purpose of this study was to assess the effects of cavity designs on the marginal leakage of class 5 glass ionomer restorations. The five cavity designs were as follows ; notch shape(A group), notch shape with groove(B group), combined lesion(C group), combined lesion with groove and deep chamfer margin(D group) and combined lesion with groove and shoulder(E group), and each design had 10 cavities. After the cavities were restored with GIC, they were immersed in 0.5% basic fuchsin solution for 6 hours. The specimens were washed thoroughly and sectioned longitudinally in a buccolingual direction through the center of the restorations. The degree of marginal leakage was measured as the extent of dye penetration under the stereoscope. The results of this study were as follows 1. The enamel margins of all groups showed lesser leakage than dentin/cementum margins(p<0.05). 2. The combined lesion(C group) showed more leakage than notch shape(A group), but there was no siginificant difference(p>0.05). 3. In the notch shape, there was no influence on the marginal leakage by the groove preparation. 4. In the combined lesion, marginal leakage was decreased by the groove preparation and marginal modification.

  • PDF

THE COMPARISON OF MICROLEAKAGE OF CLASS V COMPOSITE RESIN RESTORATIONS WITH VARIOUS DENTIN BONDING SYSTEMS (5급 와동에서 수종의 상아질 접착제에 따른 미세누출의 비교)

  • Lim, Yeon-Hee;Lee, Hee-Ju;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.153-161
    • /
    • 2001
  • The purpose of this study was to evaluate microleakage of six current dentin bonding systems. In this in vitro study, class V cavities were prepared on buccal and lingual surfaces of thirty extracted human molars. Each margin was on enamel and dentin/cementum. Experimental teeth were randomly divided into six groups of 5 each. Group 1 : Scotchbond Multi-Purpose; Group 2 : Single Bond; Group 3 : Prime&Bond NT ; Group 4 : Clearfil Liner Bond 2 ; Group 5 : MAC Bond II ; Group 6 : One-up Bond F. The bonding agent and composite resin were applied to class V cavities according to manufacturer's directions. After thermocycling, the specimens were immersed in 0.5% basic fuchsin dye solution for 6 hours and sectioned longitudinally through the center of the restoration with a low speed diamond saw. The degree of microleakage was measured as the extent of dye penetration under the stereomicroscope at $\times$20. The data were analyzed using one way ANOVA. When significant differences found. multiple comparisons were made using Duncan's Multiple Range Test. The results of this study were as follows: 1. In all groups, leakage value seen at the enamel margin was significantly lower than that seen at the dentin margin(P<0.001). 2. At the enamel margin, none of the dentin bonding systems used in this study showed statistically significant difference in leakage values(P<0.05). 3. At the cementum margin, group 3 showed the highest leakage value, and others were decreased as group 5, 6, 4 in that order, and group 1, 2 showed the lowest leakage value. There was statistically significant difference between group 3 and the other groups except for group 5(P<0.05).

  • PDF

EVALUATION OF APICAL MICROLEAKAGE AND ADAPTATION TO THE DENTINAL WALL OF THE GLASS-IONOMER ROOT CANAL CEMENT (근관충전용 글라스 아이오노머 시멘트의 근단 폐쇄성과 치질 적합성에 관한 연구)

  • Kim, Hyeon-A;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.596-608
    • /
    • 1997
  • The purpose of this study was to compare the apical leakage and adaptation to the dentinal wall of a glass ionomer root canal cement(Ketac-Endo) with those of AH-26 and Tubli-Seal. 102 single-rooted teeth were insrumented with step-back technique and randomly divided into four groups according to kinds of root canal cements: Ketac-Endo, AH-26, Tubli-Seal, and no root canal cement. Four experimental groups were as follows; Group 1 : Filling with gutta-percha and Ketac-Endo Group 2 : Filling with gutta-percha and AH-26 Group 3 : Filling with gutta-percha and Tubli-Seal Group 4 : Filling with gutta-percha without root canal cement All the specimens were obturated with lateral condensation technique, and stored in 100% humidity for 4 days. 20 teeth in each group were placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. And they were evaluated for linear dye leakage using a stereoscope and analyzed by one-way ANOVA. 22 teeth were split longitudinally and evaluated the adaptation to the dentinal wall using scanning electron microscope(4 teeth in each group) and stereoscope(2 teeth in 1, 2, 3 group). The obtained results were as follows ; 1. In case of not used root canal cement(Group 4), there was showed much degree of dye penetration comparerd with used root canal cements (Group 1, 2, 3)(P<0.01). 2. In the case of used root canal cements(Group 1, 2, 3), there was no significant difference in linear leakage in groups(P>0.01). 3. In the case of used root canal cements(Group 1, 2, 3), there was showed intimate adaptation to the dentinal wall independent on kinds of root canal cements. 4. Fractured surfaces indicated failure of cohesion in Ketac-Endo, and failure of adhesion to dentine in AH-26 and Tubli-Seal. 5. According to similar apical leakage and adaptability to the dentinal wall to another root canal cements, it is possible to be used glass-ionomer cement as root canal cement.

  • PDF

A COMPARISON OF THE APICAL SEAL PRODUCED BY EASY FILLING SYSTEM AND QUICK OBTURATION SYSTEM (Easy Filling 및 Quick Obturation System을 이용한 열연화 충전법의 치근단 밀폐도 평가)

  • Shin, Jung-In;Kum, Kee-Yeon;Lee, Sung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.202-211
    • /
    • 2000
  • The aim of this study was to compare the apical sealing ability of a new thermoplasticized gutta-percha filling technique, the Easy Filling and the Quick Obturation system with lateral condensation technique and Thermafil system to evaluate their clinical acceptabilities. Fifty-two extracted single-rooted teeth were instrumented to #35 using the .04 taper ProFile system. Four groups of 12 teeth were obturated by lateral condensation technique. Thermafil system and two new thermoplasticized gutta-percha techniques, the Easy Filling system and Quick Obturation system (Meta Dental co. Ltd. Korea), respectively. Four teeth served as controls. After the teeth were immersed in 2% methylene blue dye for 48 hours, they were resected horizontally at 1mm to 5mm level from the anatomical apex using a low-speed microtome. Each section was examined under a stereomicroscope at ${\times40}$ magnification and photographed. After each image was scanned, the leakage area was measured at each level using Brain 3 (Nosdia Tech., Korea) software. Leakage ratio was calculated for each group and was analyzed statistically to come up with the following results: 1. At 1mm level, the Quick Obturation system had the largest amount of apical leakage and it was statistically significant when compared with the lateral condensation group and the Thermafil group (p<0.05). 2. At 2mm and 3mm level, there were no significant difference of apical leakage among all four groups (p>0.05), and from 4mm level, no apical dye penetration was observed in all the groups. In conclusion, the apical seal produced by Easy Filling system and the Quick Obturation system was comparable to lateral condensation technique and Thermafil system except for the 1mm level. More improvement of the apical seal can be expected as the operator becomes skillful with the new techniques.

  • PDF