• Title/Summary/Keyword: ducting

Search Result 29, Processing Time 0.035 seconds

Estimation on the Performance of CB Scheme in Cellular System with Radio Interference (전파간섭이 존재하는 셀룰러 시스템에서의 CB 기법의 성능 평가)

  • 이성수;김종호;박상준;강영훙;이정식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.156-160
    • /
    • 2002
  • In this paper, we have estimated by means of the theoretical analysis and the simulation of FCA(Fixed Channel Assignment) and CB(Channel Borrowing) in order to consider the CB as a technique to meet ducting interference from adjacent countries. Also, we assumed that the receiving power level of ducting interference with time rate can be characterized by the normal distribution due to the previous measured results, and the ducting interferences which are exceeding the reference power level can be regarded as calls. These calls can be processed by CR assignment and by which sharing channels between cells brings to us the method of meeting the ducting interference to use spectrum resources effectively. However, the spectrum frequency reusing and the interference effects between channels should be considered in CB simulation in the future.

  • PDF

Analysis of Radio Interference through Ducting for 2.5 GHz WiMAX Service

  • Son, Ho-Kyung;Kim, Jong-Ho;Kim, Che-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.1
    • /
    • pp.94-100
    • /
    • 2012
  • Radio interference has been occurring in mobile communication services on the southern seashore in Korea. Monitoring the radio interference signal revealed that the main reason for the radio interference was a radio ducting signal coming from the seaside of Japan. In this paper, we have analyzed the effect of interference on WiMAX service using a 2.5 GHz frequency band between Korea and Japan. We focus on the interference scenario from base station to base station and we use the Minimum Coupling Loss (MCL) method for interference analysis and the Advanced Propagation Model (APM) for calculating the propagation loss in ducts. The propagation model is also compared with experimental measurement data. We confirm that the interfering signal strength depends on the antenna height and this result can be applied to deployment planning for each system with an interference impact acceptable to both parties.

A Study on the Measurement and Analysis of Radio Interferences from China (중국으로부터의 전파간섭 측정 및 분석에 관한 연구)

  • 강영흥;백정기;이성수;이형수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.740-746
    • /
    • 2001
  • Radio interferences have been a frequent problem on the TRS service, which has been in operation in the southern coastal area of Korea since 1994. By Korea-Japan joint analysis, the main reasons of the radio interferences are due to the radio ducting signal from the seaside of Japan. As the mobile services become spreading in China as well as Japan, interference problems between Korea and China will occur more frequently in various frequency bands. Therefore, in this paper we propose a method for measurement and analysis of the radio interference signal, and summarize the measurement results of interference from China, which was performed to solve the interference problem between Korea and China.

  • PDF

The Analysis of Radio Interference between Korea and China/japan using Split-step DMFT Algorithm (Sp1it-step DMFT 알고리즘을 이용한 한국과 중국/일본간 전자파 간섭특성 분석)

  • 정남호;손호경;김봉석;백정기;이형수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.2
    • /
    • pp.196-208
    • /
    • 2002
  • Since radio interference has occurred in the TRS frequency band in the south coastal area, Korea from 1994, similar interference has been observed in the mobile-cellular frequency band. Measurement showed that the sources of the radio interference are those from the base stations for digital cellular systems in Japan. This because the receiving frequency of the base stations in Korea is same as the transmitting frequency of the base stations in Japan. Since the distance between Korea and Japan is 240 ~ 300 km, we can conclude that the main reason of the interference is ducting. In this paper a ducting channel is modeled by split-step DMFT algorithm, and simulation results for measured index profile far east coast and west sea area are analyzed.

Statistical Characteristics of Atmospheric Conditions related to Radar Beam Propagation using Radiosonde Data in 2005-2006 (2005-2006년 라디오존데 자료를 이용한 레이더 빔전파와 연관된 대기상태의 통계적 특성)

  • Jung, Sung-Hwa;Lee, Gyu-Won
    • Journal of the Korean earth science society
    • /
    • v.31 no.6
    • /
    • pp.584-599
    • /
    • 2010
  • The variation of atmospheric conditions including subrefraction, normal refraction, superrefraction, and ducting is an important factor that affects the quality of radar data by controling the propagation of radar beams. The occurrence frequency of the conditions is statistically analyzed using the atmospheric soundings from seven radiosonde stations in South Korea over two years. The occurrence of superrefraction and ducting at Baengnyeongdo is significantly higher than the others. Osan and Kwangju show significant variation in time. Among the different duct conditions, the surface duct is dominant at most stations except for Gosan. The elevated duct is dominant at Heuksando and Gosan. Duct is more frequent in summer than in winter at all stations. Baengnyeongdo shows the most frequent duct in spring, fall, and winter while Pohang had the highest frequency in summer. Osan and Kwangju show least duct during all seasons. The difference of variation of monthly duct occurrence between 00 UTC and 12 UTC is insignificant at all stations except for Osan and Kwangju. Kwangju, Heuksando and Gosan show relatively low frequency of duct with the monthly maximum barely reaching 60%. The highest number of elevation angles that are affected by duct was four at Osungsan radar (KSN). The maximum elevation angle is around $1.0^{\circ}$ at all stations and Jindo radar (JNI) shows the maximum value of $1.2^{\circ}$.

Odor Removal Efficiency of Biofilter Ducting Systems in Indoor Pig House (바이오 필터를 이용한 비육돈사 배기덕트 시설의 악취저감 효과)

  • Song, J.I.;Choi, H.L.;Choi, H.C.;Kwon, D.J.;Yoo, Y.H.;Jeon, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.195-200
    • /
    • 2007
  • Management of odors is essential to swine industry in the Republic of Korea. This study was conducted to evaluate the odor removal efficiency of biofilter ducting systems. Rice straw and auto clave concrete(ALC) were used as filter medium. The ventilation fans(5 units, diameter: 500 mm) at the side wall of a growing pig housing were connected to a biofilter using a duct. The size of a biofilter is $2.5{\times}2{\times}1.2(W{\times}L{\times}H)$. The air velocities at the 300 mm above rice straw and ALC were 0.77 and 0.56 m/s, respectively. Ammonia concentration at the outlet of rice straw and ALC media were 2 and 3 ppm, respectively. Dust concentrations were also measured. The dust concentrations of rice straw and ALC were 93, $32\;mg/m^3$, respectively. There was no significant difference between filter mediums in terms of carbon dioxide concentrations(rice straw: 320, ALC: 270 mg/l). The concentration of hydrogen sulfide was stable over the experimentation. The actual concentrations of hydrogen sulfide were 4, 3 and 3 ppm at the days of 7, 21 and 36, respectively. These results suggest that biofilter ducting systems may remove odors from pig house effectively.

  • PDF

A Study on the Waterjet Propulsion in Model Scale (워터제트 추진 모형시험에 대한 연구)

  • 최균일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.5
    • /
    • pp.474-481
    • /
    • 1997
  • Waterjet propulsion generally refers to propulsion of ships by internally mounted pumps with proper ducting. This arrangement of the actuator component of the system leads to the fundamental differences with respects to screw propeller system. In this paper, the basic hydrodynamic characteristics of waterjet propulsion was outlined to clarify the application consideration and proposal for carrying out model self-propulsion tests with waterjet propelled models was presented. The results of model self-propulsion tests carried out in the Hyundai Maritime Research Institute towing tank with catamaran ship were presented.

  • PDF

Soft-$\alpha$ Filter Technology for image enhancement of MPEG-2 Video (MPEG-2 비디오의 화질 향상을 위한 소프트-$\alpha$ 필터 기법)

  • 심비연;박영배
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.04b
    • /
    • pp.109-111
    • /
    • 2002
  • Visual organs play an important role in human information recognition processes. If they are expressed in a way of digital information, it makes much bigger amount of visual information among any other information. For that reason, MPEG-2 has been taken use of to represent information compressing technology in multi-media. Although the imported data would basically contain noises, when original video images are encoded into MPET-2. Accordingly, we propose soft- $\alpha$ filter to improve image quality of digital image received from the actual image and to reduce noises from them. We also propose a method combining vertical/horizontal filter and soft- $\alpha$ filter on MPEG-2 video image. We can get two kinds of effects from the advantages of this kind of combination. Firstly, it will reduce processing time ducting horizontal and vetical filtering process. It will cover time for soft- $\alpha$ filter. Secondly, it will simplify the colors in horizontal and vertical filter. Therefore we can get clearer quality without noises from soft- $\alpha$ filter.

  • PDF

The Microstructures and Mechanical Properties on the GTA Welding conditions of Inconel 617 (Inconel 617 GTA 용접조건에 따른 미세조직 특성 및 기계적성질)

  • Choe, Seong-Bu;Lee, Bong-Geun;Gang, Jeong-Yun
    • Proceedings of the KWS Conference
    • /
    • 2005.11a
    • /
    • pp.171-173
    • /
    • 2005
  • Inconel 617 is a solid solution, nickel-chromium-cobalt-molybdenum alloy with an exceptional combination of high temperature strength and oxidation resistance. The combination of high strenth and oxidation resistance at temperatures over $1800^{\circ}F$ makes Inconel 617 an attractive material for such components as ducting, transition liners in both aircraft and gas turbine. In this study, the weldability and weldment characteristics of Inconel 617 are considered in GTAW associated with the two welding current and with back shielding gas using or not. After GTAW with 120A and 150A current, microstructures and hardness test, bending test, tensile test on room and elevated temperature for the determination of optical welding condition.

  • PDF