The Performance of Shear Strengthened Reinforced Concrete Columns with Carbon Fiber Sheets (탄소섬유시트로 전단 보강된 철근콘크리트 기둥의 성능 평가)

  • 강경원;하상수;나정민;이용택;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.733-736
    • /
    • 1999
  • R/C columns, one of the main structural members of reinforced concrete structures, usually sustain the axial forces of combined dead loads and live loads. When subjected to lateral loads, however, they are repeatedly subjected to bending moment, shearing forces and brittle failure such as shear failure can occur. This failure mode is not desirable and extra reinforcement is usually needed to induce a ductile failure. The design equation which is used to evaluate the maximum shear strength of a R/C column is still unsatisfactory. The objective of this study was, therefore, to evaluate the hysteretic strengthening effect and the maximum shear strength of R/C columns strengthened using carbon fibers on the seismic performance of the R/C columns under anti-symmetrical by acting moment. According to this study, it may be suggested that the shear of the strengthened R/C column were adequate to induce ductile failures.

  • PDF

Seismic Behavior of Non Ductile Reinforced Concrete Frame Retrofitted With Cast-In Place Infilled Shear Wall (현장타설 끼움 벽으로 보강된 비내진 상세를 갖는 철근콘크리트 골조의 내진거동)

  • Lee, Hye-Yeon;Kim, Sun-Woo;Han, Byung-Chan;Yun, Hyun-Do;Choi, Chang-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.453-456
    • /
    • 2004
  • RC frames built prior to the advent of the philosophy of ductile concrete is one type of existing construction susceptible to damage. Strengthening and stiffening of such frames has been accomplished by infilled frames with cast-in-place, reinforced concrete walls. Placement of CIP shear walls within strategic bays of a structure appears to be a logical and economical method to strengthen a reinforced concrete frame and to stiffen a building in order to reduce architectural and mechanical damage. This study investigates the seismic performance of cast-in place infilled shear wall within existing frames. The object of this study is to clarify the seismic capacity and characteristics in the hysteretic behavior of bare frame, CIP infilled shear wall and CIP infilled wall reinforced diagonal bars.

  • PDF

Bond and Flexural Behavior of RC Beams Strengthened Using Ductile PET (고연성 PET 섬유로 보강된 철근콘크리트 보의 부착 및 휨 거동)

  • Park, Hye-Sun;Kim, So-Young;Lim, Myung-Kwan;Choi, Donguk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.30-39
    • /
    • 2016
  • An experimental study was performed to investigate flexural performance and bond characteristics of RC beams strengthened using ductile polyethylene terephthalate(PET) with low elastic modulus. Bond tests were planned and completed following CSA S806. Test variables were fiber type and fiber amount. Also, total of 8 RC beams was tested. Major test variables of the beam tests included section ductility(${\mu}=3.4$, 7.0), fiber type(CF, GF, PET) and amount of fiber strengthening. Moment-curvature analyses of the beam sections were also performed. In bond tests, the bond stress distribution as well as the maximum bond stress increased with increasing amount of PET. In case of 10 layers of PET, the effective bond length was 60 mm with the maximum and the average bond stress of 2.33 and 2.10 MPa, respectively. RC beam test results revealed that the moment capacity of the RC beams strengthened using PET 10 and 20 layers increased over the control beam with little reduction in ductility by fiber strengthening. All beams strengthened using PET resulted in ductile flexural failure without any sign of fiber debonding or fiber rupture. It was important to include the mechanical properties of adhesive in the moment-curvature analysis of PET-strengthened beam sections.

A study of open cut box curvert tunnel strengthening systems in domestic underground railway (도시철도 개착식 터널의 내진성능보강시스템 개발에 대한 연구)

  • Kim, Ki-Hong;Kwon, Min-Ho;Kim, Jin-Ho;Hur, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1132-1137
    • /
    • 2010
  • There are execute of new laws about prevent of earthquake diaster in nation because of some increments of big earthquake occurence frequency. Now develope new composit plate by ductile fiber with strong mechanic materials, which compose of strengthening systems for the underground structures subject to forced displacements. This study is to focus to develop the retrofitting system for the cut and cuver tunnels built without earthquake type load scenario, so that it can provide the safety of existing urban subway system against earthquakes.

  • PDF

A Study on the Maximum Load of R/C Beams Strengthened by Carbon Fiber Sheets (탄소섬유시트로 보강된 R/C 보의 최대내력에 관한 연구)

  • Choi, Chang-Sik;Kim, Yong-Chae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.199-204
    • /
    • 2001
  • Recently, strengthening of structural members by adhesion of steel plate or fiber sheets is generally used. Particularly, the Carbon Fiber Sheets (CFS) is widely used. Rut, the strengthening effect of the CFS is not clearly define yet. Therefore, this paper is designed to evaluate the effectiveness of CFS methods by analyzing previous studies in statistics. According to the results, the maximum load carrying capacity is increased up to 0.16 times when the reinforced concrete beams were strengthened by CFS which is standard specimens. The number of sheets made some effect on the strength while, the other parameters influenced the ductile capacity.

  • PDF

Experimental investigation of retrofitted shear walls reinforced with welded wire mesh fabric

  • Yuksel, Suleyman B.
    • Structural Engineering and Mechanics
    • /
    • v.70 no.2
    • /
    • pp.133-141
    • /
    • 2019
  • The aim of the present paper is to present the cyclic behavior of strengthened reinforced concrete shear wall test specimen, which was reinforced with cold drawn welded wire mesh fabric. Two reinforced concrete shear wall specimens have been tested in the present study. The walls were tested under reversed cyclic loading with loading applied near the tip of the walls. The control wall is tested in its original state to serve as a baseline for the evaluation of the repair and strengthening techniques. The two test specimens include a control wall and a repaired wall. The control wall test specimen was designed and detailed to simulate non-ductile reinforced concrete shear walls that do not meet the modern seismic provisions. The response of the original wall was associated with the brittle failure. The control shear wall was repaired by addition of the reinforcements and the concrete and then it was reloaded. The effectiveness of the repair technique was investigated. Test results indicate that there can be a near full restoration of the walls' strength. The data from this test, augmenting other data available in the literature, will be useful in calibrating improved analytical methods as they are developed.

Pseudo-Ductile Hybrid FRP Sheet for Strengthening Reinforced Concrete Beams (유사연성 하이브리드 FRP 시트를 이용한 RC 보의 휨 보강)

  • Ha, Sang-Su;Choi, Dong-Uk;Lee, Chin-Yong;Kim, Kil-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.239-247
    • /
    • 2008
  • Use of both carbon fiber (CF) and glass fiber (GF) at the same time to strengthen existing flexural members was exploited. Using a proper volumetric GF / CF ratio, the CF can rupture first followed by subsequent rupture of GF at higher stress and strain showing a pseudo-ductile behavior. A theoretical study indicated that the ratio is 4.62 : 1 and higher where the pseudoductile effect can be shown. Flexural tests of plain concrete beams strengthened using fibers were first carried out. Hybrid FRP sheet using 8.8 : 1 ratio was then fabricated and the sheet was used to strengthen reinforced concrete beams. The RC beams strengthened using 1-ply and 2-ply hybrid sheets both revealed increased strength over a non-strengthened beam and ductile flexural behavior. A comparable beam strengthened using CF also showed increased strength but with limited ductility.

A Experimental Study on the Flexural Characteristics (GFRP로 보강된 RC보의 휨특성에 관한 실험적 연구)

  • 심종성;김규선;이석무;김경민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.559-565
    • /
    • 1998
  • Flexural tests on 2.4m long reinforced concrete beams with epoxy-bonded GFRP plates are reported in these tests. The selected experimental variables are strengthening plate length, plate thickness, plate width and the method of anchoring the plate ends. The effects of these variables in overall behavior are discussed. The results generally indicate that the flexural strength of strengthened beams is increased. The ductile behavior of tested beams in inversely proportional to the plate thickness, plate width. The use of an U-jacket plate provided a proper anchorage system and improved the ductility of beams.

  • PDF

Seismic Performance of Non-ductile Reinforced Concrete Frames with Precast ECC Wall Panels (프리캐스트 ECC 벽판으로 보강된 비내진 상세를 갖는 철근콘크리트 골조의 내진성능)

  • Kim, Ji-Hyeon;Jo, Seong-Pill;Seo, Soo-Yeon;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.105-112
    • /
    • 2019
  • This study was conducted to examine experimentally the seismic performance of non-ductile reinforced concrete (RC) frames retrofitted with precast(PC) engineered cementitious composite (ECC) wall panels. The seismic performance was investigated through cyclic load tests on RC frame with different aspect ratio (hw/lw = 2 and 3) and installation position (center and both side of RC frame) of the PC ECC wall panels. Test results indicated that the seismic strengthening method using PC ECC wall panels is effective to improve significantly the strength, stiffness and energy dissipation capacity of non-ductile RC frame. Based on test results, it can be recommended to install PC ECC wall panel at the center of RC frame for improving the strength and to install slender wall panels at both side of RC frame for increasing ductility.

Strengthening of reinforced concrete beams using external steel members

  • Demir, Ali;Ercan, Emre;Demir, Duygu Donmez
    • Steel and Composite Structures
    • /
    • v.27 no.4
    • /
    • pp.453-464
    • /
    • 2018
  • The objective of this study is to devise an alternative strengthening method to the ones available in the literature. So, external steel members were used to enhance both flexural and shear capacities of reinforced concrete (RC) beams having insufficient shear capacity. Two types of RC beams, one without stirrups and one with lacking stirrups, were prepared in the study. These beams were strengthened with external steel clamps devised by the authors and with external longitudinal reinforcements. Although the use of clamps alone didn't have a significant effect on the load carrying capacity of the tested beams, the ductility increased approximately tenfold and the failure behavior changed from brittle to ductile. Although the use of clamps and longitudinal reinforcements together did not significantly increase the ductility of the beams, it approximately doubled their load capacities. The results of the experimental study were compared to the ones obtained from nonlinear finite element analysis (NLFEA) and it was observed that they were compatible. Finally, it can be concluded that the devised method could be applied to structural members as an alternative to methods in application due to lightness, low-cost, easy applicable and reliable.