• Title/Summary/Keyword: dual-rate

Search Result 827, Processing Time 0.026 seconds

Analysis of Smartphone Addiction Status and Risk among Elementary Students (초등학생의 스마트폰 중독 실태 및 위험 분석)

  • Lee, Soojung
    • Journal of The Korean Association of Information Education
    • /
    • v.18 no.2
    • /
    • pp.203-212
    • /
    • 2014
  • With regard to recently emerged problems of smartphone addiction among adults and adolescents, this paper researched upper-grade elementary students depending on various demographic factors that have not been studied thoroughly so far. The survey was conducted on 1570 students in grades 4~6 of schools in Gyeonggi province. Results showed that, first, the average rate of smartphone ownership was about 66%. Second, about 1% of the students belonged to high-risk group, 5.7% to at-risk group, and normal user group was 93.3%. Third, based on the demographic factors, grade and academic achievements each was significantly correlated to the type of addiction group. For example, students with poor academic performance or in higher grade were more likely to be highly addictive. Fourth, both groups of at-risk and of normal-user pertaining to these factors - in urban areas, male students, sixth-grade, in dual income families - showed higher addictiveness score. But they were contrasted in the aspects of household economy and academic performance: at-risk group was more addictive in affluent families or excellent academic performance, whereas normal-user group had higher level of addictiveness in case of poor families or lower academic performance.

4-Channel 3.2/6.4-Gbps Dual-rate Transmitter (채널 3.2/6.4 Gbps 이중 전송률 송신기)

  • Kim, Du-Ho;Choi, Woo-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.37-43
    • /
    • 2010
  • As the speed of A/V streaming, the transmission-speed requirement of serial link is continuously increasing. Consequently, commercial standards, which are released previously, are increasing transmission speed in their newly-updated versions. The flexibility between previous and updated versions is very important requirement, therefore, the transceiver which can operates at more than one data rate is important market demand. This paper demonstrates 4-channel 3.2/ 6.4 Gbps transmitter, which is capable of selecting 1, 1.5, 2, and 3 times of pre-emphasis and 200, 300, 400, and 600 mVdiff,p2p of output swing. The prototype chip was fabricated using $0.13{\mu}m$ CMOS process. Its performances are verified on PCB using COB packaging.

Saturation Headway of Through Movement at Signalized Intersections in Urban Area (도시부 신호교차로에서 직진이동류의 포화차두시간)

  • 이향숙;도철웅
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.5
    • /
    • pp.23-31
    • /
    • 2002
  • The headway of vehicles entering an intersection is closely related with the saturation flow rate and is a basic parameter required for determining the saturation headway and the start-up lost delay. Since such headway value reflects the drivers' behaviors and features of the intersection, all intersections don't have an equal value, but are affected by number and location of their lanes, changing types, local characteristics and time zone. Accordingly, this study attempted to suggest proper values on the basis of data by investigating headway in lanes. Number of exclusive through lanes was divided into single lane, double lanes and triple lanes, the locations of lanes were divided into inside lane, central lane and outside lane. As a result of investigating the headway, single through lane, double through lanes-inside lane, and triple through lane-outside lane showed as 1.73 sec., 1.71 sec. and 1.93sec., respectively. The result of calculating the area factor of business areas by fixing 1.00 for the residental area and applying relation between headway and saturation flow rate was 0.96. In the case of start-up lost delay lead dual left turn and directional separation were 1.41 sec. and 3.27 sec., respectively, showing the great difference. Therefore, different start-up lost delay according to changing type should be applied.

A Study on the Wet Clutch Pattern Design for the Drag Torque Reduction in Wet DCT System (습식 DCT의 드래그 토크 저감을 위한 클러치 패드 유로 설계)

  • Cho, Junghee;Han, Juneyeol;Kim, Woo-Jung;Jang, Siyoul
    • Tribology and Lubricants
    • /
    • v.33 no.2
    • /
    • pp.71-78
    • /
    • 2017
  • The drag torque in the wet clutch system of a dual clutch transmission system is investigated because it is relatively high, up to 10 of the total output torque of the engine, even when the clutch is in the disengagement state with zero torque transfer. Drag torque results from the shear resistance of the DCTF between the friction pad and separator plate. To reduce the drag torque for ensuring fuel economy, the groove pattern of the wet clutch friction pad is designed to have a high flow rate through the pattern groove. In this study, four types of groove patterns on the friction pad are designed. The volume fraction of the DCTF (VOF) and hydrodynamic pressure developments in the gap between the friction pad and separator plate are computed to correlate with the computation of the drag torque. From the computational results, it is found that a high VOF and hydrodynamics increase the drag torque resulting from the shear resistance of the DCTF. Therefore, a patterned groove design should be used for increasing the flow rate to have more air parts in the gap to reduce the drag torque. In this study, ANSYS FLUENT is used to solve the flow analysis.

Enhancement of signal-to-noise ratio for uroflowmetric test regardless of urination situation (요속검사시 배뇨상황에 무관한 신호대잡음비 개선 기법)

  • Kim, Kyung-Ah;Choi, Seong-Su;Lee, Sang-Bong;Kim, Kyoung-Oak;Park, Kyung-Soon;Shin, Eun-Young;Kim, Wun-Jae;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.423-431
    • /
    • 2009
  • Standard uroflowmetry measures the urine weight using single load cell to evaluate the urinary flow rate. Impact noise should be introduced due to gravity when the urine stream falls down into the container upon the load cell. The present study placed three load cells on the three vertices of a regular triangle and the three signals were ensemble averaged to enhance the signal-to-noise ratio(SNR) regardless of how the urination was made. Simulated urination experiment was performed with three different urine collection methods. In all three methods, SNR of the averaged signal was much higher than each load cell signals. With no urine collection device, the present signal averaging technique resulted in SNR values higher by 10~15 dB than when dual funnels or upper funnel were used to guide the urine stream. Therefore, it was demonstrated that the three point measurement followed by with ensemble averaging could enable accurate uroflowmetric test without any specially made urine collection devices.

Simplified Near Optimal Downlink Beamforming Schemes in Multi-Cell Environment (다중 셀 환경에서 적은 복잡도를 갖는 준 최적 하향 빔형성)

  • Yang, Jang-Hoon;Kim, Dong-Ku
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12C
    • /
    • pp.764-773
    • /
    • 2011
  • Despite enormous performance gain with multi-antenna transmission in the single cell environment, its gain diminishes out in the multi-cell environment due to interference. It is also very hard to solve the efficient downlink beamforming with low complexity in multi-cell environment. First, this paper shows that the asymptotically sum rate optimal downlink beamformings at low and high SNR are maximum ratio transmit (MRT) and zero forcing (ZF) beamforming in the multi-cell system, respectively. Secondly, exploiting the asymptotically optimal downlink beamforming, we develop simple two types of near optimal downlink beamforming schemes having the form of minimum mean squared error (MMSE) beamforming obtained from the dual uplink problem. For each type, three different subclasses are also considered depending on the computational complexity. The simulation results show that the proposed near optimum algorithms provide the trade-off between the complexity and the performance.

A Study on the Factors Affecting the Arson (방화 발생에 영향을 미치는 요인에 관한 연구)

  • Kim, Young-Chul;Bak, Woo-Sung;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.69-75
    • /
    • 2014
  • This study derives the factors which affect the occurrence of arson from statistical data (population, economic, and social factors) by multiple regression analysis. Multiple regression analysis applies to 4 forms of functions, linear functions, semi-log functions, inverse log functions, and dual log functions. Also analysis respectively functions by using the stepwise progress which considered selection and deletion of the independent variable factors by each steps. In order to solve a problem of multiple regression analysis, autocorrelation and multicollinearity, Variance Inflation Factor (VIF) and the Durbin-Watson coefficient were considered. Through the analysis, the optimal model was determined by adjusted Rsquared which means statistical significance used determination, Adjusted R-squared of linear function is scored 0.935 (93.5%), the highest of the 4 forms of function, and so linear function is the optimal model in this study. Then interpretation to the optimal model is conducted. As a result of the analysis, the factors affecting the arson were resulted in lines, the incidence of crime (0.829), the general divorce rate (0.151), the financial autonomy rate (0.149), and the consumer price index (0.099).

Expression of Arabidopsis thaliana SIK (Stress Inducible Kinase) Gene in a Potato Cultivar (Solanum tuberosum L. 'Taedong Valley')

  • Yoon Jung-Ha;Fang Yi-Lan;Park Eung-Jun;Kim Hye-Jin;Na Yun-Jeong;Lee Dong-Hee;Yang Deok-Chun;Lim Hak-Tae
    • Plant Resources
    • /
    • v.8 no.3
    • /
    • pp.202-208
    • /
    • 2005
  • Osmotic stress is one of major limiting factors in crop production. In particular, seasonal drought often causes the secondary disease in the field, resulting in severe reduction in both quality and productivity. Recent efforts have revealed that many genes encoding protein kinases play important roles in osmotic stress signal transduction pathways. Previously, the AtSIK (Arabidopsis thaliana Stress Inducible Kinase) mutants have shown to enhance tolerance to abiotic stresses, accompanying with higher expression of abiotic stress-related genes than did the wild-type plants. In this study, we have transformed potato (cv. Taedong Valley) with the AtSIK expression cassette. Both PCR and RT-PCR using AtSIK-specific primers showed stable integration and expression of the AtSIK gene in individual transgenic lines, respectively. Foliar application of herbicide ($Basta^{(R)}$) at commercial application rate (0.3% (v/v)) revealed another evidence of stable gene introduction of T-DNA which includes the bar gene for herbicide resistance. Overexpression of the AtSIK gene under dual CaMV35S promoter increased sensitivity to salt stress (300 mM NaCl), which was demonstrated by the reduction rate of chlorophyll contents in leaves of transgenic potato lines. These results suggest that possible increase of osmotic tolerance in potato plants may be achieved by antisense expression of AtSIK gene.

  • PDF

The Effect of Dielectric Thickness and Barrier Rib Height on Addressing Time of Coplanar ac PDP

  • Lee, Sung-Hyun;Kim, Young-Dae;Shin, Joong-Hong;Cho, Jung-Soo;Park, Chung-Hoo
    • Journal of KIEE
    • /
    • v.11 no.1
    • /
    • pp.41-45
    • /
    • 2001
  • The addressing time should be reduced by modifying cell structure and/or driving method in order to replace the dual scan system by single scan and increase the luminance in large ac plasma display panel(PDP). In this paper, the effects of the dielectric layer thickness and the barrier rib height on the addressing time of ac PDP are investigated. It is found out that the addressing time was decreased with decreasing thickness of dielectric layer on the front glass and thickness of white dielectric layer on the rear glass. The decreasing rate were 160ns/10${\mu}{\textrm}{m}$ and 270nsd/10${\mu}{\textrm}{m}$, respectively. Also in case of decreasing the height of barrier rib, addressing time was decreased at the rate of 550ns/10${\mu}m$.

  • PDF

An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data (Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.