• Title/Summary/Keyword: dual-core

Search Result 239, Processing Time 0.037 seconds

The Comparison of Output Characteristic by the Electro-magnetic Structure Modification of the Axial Flux Type Permanent Magnet Synchronous Generator (종축 자속형 영구자석 동기 발전기의 전자기적 구조 변경에 따른 출력특성 비교)

  • Jung, Tae-Uk;Bae, Byung-Duk;Kim, Hoe-Cheon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.42-48
    • /
    • 2011
  • Generally, the structure without the stator core Axial Field Permanent Magnet (AFPM) generator was simple and there was nearly no cogging toque. And because it had the wide driving rate area, it had been being mainly used in the small wind power generation system. However, AFPM generator with non-slotted stator can't generate high voltage at low wind speed due to long air-gap. It is the reason of output efficiency drop. Therefore, in this paper, the AFPM synchronous generator with internal rotor and dual slotted stators for the small wind turbine is studied, and deal with a cogging torque minimization through the determination of optimum pole-arc ratio.

Adaptive TCX Windowing Technology for Unified Structure MPEG-D USAC

  • Lee, Tae-Jin;Beack, Seung-Kwon;Kang, Kyeong-Ok;Kim, Whan-Woo
    • ETRI Journal
    • /
    • v.34 no.3
    • /
    • pp.474-477
    • /
    • 2012
  • The MPEG-D unified speech and audio coding (USAC) standardization process was initiated by MPEG to develop an audio codec that is able to provide consistent quality for mixed speech and music contents. The current USAC reference model structure consists of frequency domain (FD) and linear prediction domain (LPD) core modules and is controlled using a signal classifier tool. In this letter, we propose an LPD single-mode USAC structure using an adaptive widowing-based transform-coded excitation module. We tested our system using official test items for all mono-evaluation modes. The results of the experiment show that the objective and subjective performances of the proposed single-mode USAC system are better than those of the FD/LPD dual-mode USAC system.

Design for the Semaphore Interface Function of the Dual Core Embedded Linux System (듀얼코어 임베디드 리눅스 시스템에서 코어간 세마포어 인터페이스 기능 설계)

  • Jung, Ji-Sung;Lee, Jae-Gi
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.10a
    • /
    • pp.97-100
    • /
    • 2018
  • 세마포어 처리문제는 프로세스간 메시지를 전송하거나 공유메모리를 통해 특정 데이터를 공유할 때 발생되는 문제로 공유된 자원에 여러 개의 프로세스가 동시에 접근하면 안되며, 단지 한번에 하나의 프로세서만 접근 가능하도록 하여야 한다. 세마포어 기본정책은 호출되는 코어에 생성되며, 다른 코어에서는 IPI를 통해 존재 여부를 확인한다. 동일 코어에서 접근 시 기존방식으로 사용한다. 본 논문에서는 서로 다른 코어 및 운영체제에서 다른 코어에서 접근할 때에는 IPI를 통해 존재 여부를 확인한 후 더미 세마포어 구조체를 생성하여 관련 정보를 유지하고 해당 요청을 처리해 주는 세마포어 인터페이스 기능 설계 방법을 제안한다. 제안하는 세마포어 인터페이스 기능 설계 방안은 멀티 태스킹 기술 구현으로 기존 코어가 가지고 있는 성능상의 문제를 해결해 준다.

The Study for Supporting IPv6 in GGSN of UMTS/GPRS (UMTS/GPRS의 GGSN에서 IPv6 지원 방안에 대한 연구)

  • Lim, Sun-Hwa;Kim, Yeong-Jin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.04b
    • /
    • pp.1257-1260
    • /
    • 2002
  • 3 세대 이동통신 시스템인 UMTS/GPRS 는 모든 MS(Mobile Station)에게 인터넷 서비스를 항상 제공할 수 있도록 하는 것을 목표로 하고 있다. 그러나 최근 인터넷 사용의 증가로 인해 public IPv4 주소 부족 현상이 발생함에 따라 인터넷에 연결되어 있는 모든 MS 에게 public IPv4 주소를 할당하는데 한계가 있다. 이에 따라 3GPP의 Release 2000 IM CN(IP Multimedia Core Network) 서브 시스템에서는 멀티미디어 서비스 지원을 위해 인터넷에 연결되어 있는 모든 MS 에게 IP 를 할당할 수 있도록 IPv6 지원을 필수로 정의하고 있다. 따라서 UMTS/GPRS 에서 IPv6 를 지원할 경우 이동망과 인터넷망간의 패킷 서비스 전달을 위해 게이트웨이 기능을 수행하는 GGSN 에서 가장 큰 변화가 이루어질 것이다. 그러므로 본 논문에서는 GGSN 이 dual stack 을 지원해야하는지에 대해 살펴본 후 UMTS/GPRS 프로토콜 구조를 제안한다. 그리고 IPv6 지원을 위해 GGSN의 기능을 설계하고 GTP 메시지와 IPv6 주소 할당 방법에 대해 살펴본다.

  • PDF

Some Reactor Kinetics Properties of the $250MW_th$ AMBIDEXTER Circulating Fuel Core (용융염 핵연료 원자로 AMBIDEXTER의 동특성 해석)

  • 김태규;윤정선;원성희;임현진;조재국;오세기
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.119-126
    • /
    • 1999
  • 농축우라늄 고체핵연료를 사용하는 기존의 발전용 원자로 개념에서는 냉각기능의 상실 또는 반응도 상실사고와 같은 극심한 열적 불균형에 의해 핵연료의 온도가 급격히 증가하고, 결과적으로 핵연료의 파손 및 용융으로 발전할 수 있다. 본 연구는 이러한 기존 발전로의 고유 안정성 문제를 획기적으로 해결할 수 있는 혁신형으로서 Th/$^{233}$ U 용융염핵연료주기를 사용하며 원자로계통 전체를 원자로용기에 내장하는 일체형 원자로개념의 AMBIDEXTER (Advanced Molten-salt Break-even Inherently-safe Dual-mission Experimental and TEst Reactor) 원자력 에너지시스템의 동특성을 해석하기 위해 수행되고 있다.(중략)

  • PDF

The Pixel Shading on Multi Core GP-GPU with Dual Phase Architecture (듀얼 페이즈 구조의 멀티 코어 GP-GPU를 이용한 픽셀 셰이딩)

  • Kim, Jun-Seo;Park, Tae-Ryong;Lee, Kwang-Yeob
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.339-342
    • /
    • 2010
  • 최근 프로세서가 클럭 향상의 한계에 부딪힘에 따라, 프로세서의 성능을 향상시키기 위해 멀티 코어 기반의 병렬처리를 이용한 방법들이 제안 되고 있다. 본 논문은 여러개의 연산기를 한 명령어 사이클에 동시에 사용할 수 있는 MIMD(Multiple Instruction, Multiple Data) 구조를 가지며, Scratch Counter를 이용해 멀티 코어와 멀티 스레드의 작업을 할당하는 구조의 GP-GPU(General Purpose - Graphics Processing Unit)를 활용해 멀티 코어, 멀티 스레드 환경에서의 효율적인 픽셀 셰이딩 방법을 설계 하였다. 선형 안개 픽셀 셰이딩의 경우 싱글코어에서 18.3 FPS이며 4개의 멀티코어 GP-GPU에서는 4배가 증가한 73.2 FPS 결과를 얻었다.

  • PDF

A summary of KEPCO's 765kV substation design (한전 765kV 변전소의 기본설계 개요)

  • Kim, M.D.;Jung, S.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2139-2142
    • /
    • 1999
  • 765kV substations which will be the core installation of the bulk power transmission system in Korea for the upcoming $21^{st}$ century, were designed of outdoor full GIS type to minimize required area. As principal equipment, main transformers of 2,000 MVA per bank and 50kA 8,000A gas insulated switchgears of up-to-date technology were adopted in designing substations to transmit bulk power of 10GW. Dual digital protective relay systems and distributed indication and control systems with fiber optic LAN were used.

  • PDF

Microleakage of endodontically treated teeth restored with three different esthetic post and cores (심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구)

  • Park, Ji-Geun;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Statement of problem: At present, as the esthetic demands are on the increase, there are many ongoing studies for tooth-colored post and cores. Most of them are about fiber post and prefabricated zirconia post, but few about one-piece milled zirconia post and core using CAD/CAM (computer-aided design/computer-aided manufacturing) technique. Purpose: The objective of this study was to compare microleakage of endodontically treated teeth restored with three different tooth-colored post and cores. Material and methods: Extracted 27 human maxillary incisors were cut at the cementoenamel junction, and the teeth were endodontically treated. Teeth were divided into 3 groups (n=9); restored with fiber post and resin core, prefabricated zirconia post and heat-pressed ceramic core, and CAD/CAM milled zirconia post and core. After the preparation of post space, each post was cemented with dual-polymerized resin cement (Variolink II). Teeth were thermocycled for 1000 cycles between $5-55^{\circ}C$ and dyed in 2% methylene blue at $37^{\circ}C$ for 24 hours. Teeth were sectioned (bucco-lingual), kept the record of microleakage and then image-analyzed using a microscope and computer program. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: All groups showed microleakage and there were no significant differences among the groups (P>.05). Prefabricated zirconia post and heat-pressed ceramic core showed more leakage in dye penetration at the post-tooth margin, but there was little microleakage at the end of the post. Fiber post and resin core group and CAD/CAM milled zirconia post and core group indicated similar microleakage score in each stage. Conclusion: Prefabricated zirconia post and heat-pressed ceramic core group demonstrated better resistance to leakage, and fiber post and resin core group and CAD/CAM milled zirconia post and core group showed the similar patterns. The ANOVA test didn't indicate significant differences in microleakage among test groups. (P>.05)

Characteristics of Open-Loop Current Sensor with Temperature Compensation Circuit (온도보상회로를 부착한 개방형 전류측정기의 특성)

  • Ku, Myung-Hwan;Park, Ju-Gyeong;Cha, Guee-Soo;Kim, Dong-Hui;Choi, Jong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8306-8313
    • /
    • 2015
  • Open-type current sensors have been commonly used for DC motor controller, AC variable controller and Uninterruptible Power Supply. Recently they have begun to be used more widely, as the growth of renewable energy and smart-grid in power system. Considering most of the open-type current sensors are imported, developing the core technology needed to produce open-type current sensors is required. This paper describes the development and test results of open-type current sensors. Design of C type magnetic core, selection and test of a Hall sensor, design of current source circuit and signal conditioning circuit are described. 100A class DIP(Dual In-line Package) type and SMD(Surface Mount Devide) type open-type current sensors was made and tested. Test results show that the developed open-type current sensor satisfies the accuracy requirement of 2% and linearity requirement of 2% at 100 A of DC and AC current of 60Hz. Temperature compensation was carried out by using a temperature compensation circuit with NTC(Negative Temperature Coefficient) thermistor and the effect of the temperature compensation are described.

Current Limiting and Recovery Characteristics of Two Magnetically Coupled Type SFCL with Two Coils Connected in Parallel Using Dual Iron Cores (이중철심을 이용한 병렬연결된 자기결합형 초전도한류기의 전류제한 및 회복특성)

  • Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.717-722
    • /
    • 2016
  • In this paper, in order to support the peak current limiting function depending on the intensity of the fault current at the early stage of failure, a two magnetically coupled type superconducting fault current limiter (SFCL) is proposed, which includes high-Tc superconducting (HTSC) element 1, where the existing primary and secondary coils are connected to one iron core in parallel, and HTSC element 2, which is connected to the tertiary winding using an additional iron core. The results of the experiments in this study confirmed that the two magnetic coupling type SFCL having coil 1 and coil 2 connected in parallel using dual iron cores is capable of having only HTSC element 1 support the burden of the peak current when a failure occurs. The reason for this is that although HTSC element 1 was quenched and malfunctioned because the instantaneous factor of the initial fault current was large, the current flowing to coil 3 did not exceed the critical current, which would otherwise cause HTSC element 2 to be quenched and not function. In order to limit the peak current upon fault through the sequential HTSC elements, the design should allow it to have the same value as the low value of coil 1 while having coil 3 possess a higher self-inductance value than coil 2. In addition, a short-circuit simulation experiment was conducted to examine and validate the current limiting and recovery characteristics of the SFCL when the winding ratio between coil 1 and coil 2 was 0.25. Through the analysis of the short-circuit tests, the current limiting and recovery characteristics in the case of the additive polarity winding was confirmed to be superior to that of the subtractive polarity winding.