• Title/Summary/Keyword: dual coverage

Search Result 61, Processing Time 0.021 seconds

PAGAN II: THE EVOLUTION OF AGN JETS ON SUB-PARSEC SCALES

  • OH, JUNGHWAN;TRIPPE, SASCHA;KANG, SINCHEOL;KIM, JAE-YOUNG;PARK, JONG-HO;LEE, TAESEOK;KIM, DAEWON;KINO, MOTOKI;LEE, SANG-SUNG;SOHN, BONG WON
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.5
    • /
    • pp.299-311
    • /
    • 2015
  • We report first results from KVN and VERA Array (KaVA) VLBI observations obtained in the frame of our Plasma-physics of Active Galactic Nuclei (PAGaN) project. We observed eight selected AGN at 22 and 43 GHz in single polarization (LCP) between March 2014 and April 2015. Each source was observed for 6 to 8 hours per observing run to maximize the uv coverage. We obtained a total of 15 deep high-resolution images permitting the identification of individual circular Gaussian jet components and three spectral index maps of BL Lac, 3C 111 and 3C 345 from simultaneous dual-frequency observations. The spectral index maps show trends in agreement with general expectations – flat core and steep jets – while the actual value of the spectral index for jets shows indications for a dependence on AGN type. We analyzed the kinematics of jet components of BL Lac and 3C 111, detecting superluminal proper motions with maximum apparent speeds of about 5c. This constrains the lower limits of the intrinsic component velocities to ~ 0.98c and the upper limits of the angle between jet and line of sight to ~20°. In agreement with global jet expansion, jet components show systematically larger diameters d at larger core distances r, following the global relation d ≈ 0.2r, albeit within substantial scatter.

Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns

  • Choi, Jae-Won;Bae, Ik-Hyun;Noh, Tae-Hwan;Ju, Sung-Won;Lee, Tae-Kyoung;Ahn, Jin-Soo;Jeong, Tae-Sung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.43-52
    • /
    • 2016
  • PURPOSE. This study was conducted to evaluate the effects of full-coverage all-ceramic zirconia, lithium disilicate glass-ceramic, leucite glass-ceramic, or stainless steel crowns on antagonistic primary tooth wear. MATERIALS AND METHODS. There were four study groups: the stainless steel (Steel) group, the leucite glass-ceramic (Leucite) group, the lithium disilicate glass-ceramic (Lithium) group, and the monolithic zirconia (Zirconia) group. Ten flat crown specimens were prepared per group; opposing teeth were prepared using primary canines. A wear test was conducted over 100,000 chewing cycles using a dual-axis chewing simulator and a 50 N masticating force, and wear losses of antagonistic teeth and restorative materials were calculated using a three-dimensional profiling system and an electronic scale, respectively. Statistical significance was determined using One-way ANOVA and Tukey's test (P<.05). RESULTS. The Leucite group ($2.670{\pm}1.471mm^3$) showed the greatest amount of antagonist tooth wear, followed by in decreasing order by the Lithium ($2.042{\pm}0.696mm^3$), Zirconia ($1.426{\pm}0.477mm^3$), and Steel groups ($0.397{\pm}0.192mm^3$). Mean volume losses in the Leucite and Lithium groups were significantly greater than in the Steel group (P<.05). No significant difference was observed between mean volume losses in the Zirconia and Steel groups (P>.05). CONCLUSION. Leucite glass-ceramic and lithium disilicate glass-ceramic cause more primary tooth wear than stainless steel or zirconia.

Development of the High Reliable Safety PLC for the Nuclear Power Plants (고신뢰도 안전등급 제어기기 개발)

  • Son, Kwang-Seop;Kim, Dong-Hoon;Son, Choul-Woong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.109-119
    • /
    • 2013
  • This paper presents the design of the Safety Programmable Logic Controller (SPLC) used in the Nuclear Power Plants, an analysis of a reliability for the SPLC using a markov model. The architecture of the SPLC is designed to have the multiple modular redundancy composed of the Dual Modular Redundancy(DMR) and the Triple Modular Redundancy(TMR). The operating system of the SPLC is designed to have the non-preemptive state based scheduler and the supervisory task managing the sequential scheduling, timing of tasks, diagnostic and security. The data communication of the SPLC is designed to have the deterministic state based protocol, and is designed to satisfy the effective transmission capacity of 20Mbps. Using Markov model, the reliability of SPLC is analyzed, and assessed. To have the reasonable reliability such as the mean time to failure (MTTF) more than 10,000 hours, the failure rate of each SPLC module should be less than $2{\times}10^{-5}$/hour. When the fault coverage factor (FCF) is increased by 0.1, the MTTF is improved by about 4 months, thus to enhance the MTTF effectively, it is needed that the diagnostic ability of each SPLC module should be strengthened. Also as the result of comparison the SPLC and the existing safety grade PLCs, the reliability and MTTF of SPLC is up to 1.6-times and up to 22,000 hours better than the existing PLCs.

Design of Antenna for Beam Scanning for Dual-Band base station (이중대역 기지국용 빔 스캔 안테나 설계)

  • Ko Jin-Hyun;Jang Jae-Su;Ha Jae-Kwon;Park Sae-Houn
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.632-636
    • /
    • 2006
  • It is needed to use the beam scanning to control the cell coverage of the base station considering operation conditions, season, time period, radiation character and mobility of customers and vehicles for varied wireless communication service and quality improvement. This paper proposes a mobile antenna system which can obtain the characteristics of the beam scanning by controlling the directivity depending on the operation condition. Radiation block is made of 2 sub-array of $1\times3$ patched antennas for ITS of 5.8GHZ bandwidth with the gain of 13dBi, and of 2 sub-array of single patched antenna for WiBro of 2.3GHZ bandwidth with the gain of 12dBi. RF module is made of a switch, an amplifier, a PAD, a 3-Bit phase shifter, and a power divider. The system is able to control the beam tilting with electronic methode by using 3-bit phase shifter$(45^{\circ},\;90^{\circ},\;180^{\circ})$.

  • PDF

Relay Network using UAV: Survey of Physical Layer and Performance Enhancement Issue (무인항공기를 이용한 중계네트워크: 물리계층 동향분석 및 성능향상 이슈)

  • Cho, Woong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.901-906
    • /
    • 2019
  • UAV (Unmanned Aerial Vehicle) is widely used in various areas such as civil and military applications including entertainment industries. Among them, UAV based communication system is also one of the important application areas. Relays have been received much attention in communication system due to its benefits of performance enhancement and coverage extension. In this paper, we investigate UAVs as relays especially focusing on physical layer. First, we introduce the research on UAV application for the relays, then the basic performance of relay networks in dual-hop communication system is analyzed by adopting decode-and-forward (DF) relaying protocol. The performance is represented using symbol error rate (SER) and UAV channels are applied by assuming asymmetric environments. Based on the performance analysis, we discuss performance enhancement issues by considering physical layer.

A Study on Increasing Security Following Mutual Interaction and Integration of Dualized Security Category between Information Security and Personal Information Protection (정보보안과 개인정보보호 간의 이원화 보안범주의 상호연계 및 통합에 따른 보안성 증대에 대한 연구)

  • Seo, Woo-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.3
    • /
    • pp.601-608
    • /
    • 2018
  • While the legislation on the protection of personal information in public institutions was enacted and amended, the guidelines and laws on information security were focused, contracted and realized with focus on specific institutions. Mutual laws and guidelines have been applied and realized for the dual purpose of securing both the asset of macroscopic information and the asset of personally identification information, which are mutually different media information. However, in a bid to present the definition and direction of the fourth industrial revolution in 2017, a variety of products and solutions for security designed to ensure the best safety line of the 21st century, and the third technology with the comprehensive coverage for all these fields, a number of solutions and technologies, including IOT(: Internet of Things), ICT Internet of Things(: ICT), ICT Cloud, and AI (: Artificial Intelligence) are pouring into the security market as if plastic doll toys were manufactured in massive scale into the market. With the rising need for guaranteeing the interrelation for securities with dualistic physical, administrative, logical and psychological differences, that is, information security and personal information security that are classified into two main categories and for the enhanced security for integrated management and technical application, the study aims to acquire the optimal security by analyzing the interrelationship between the two cases and applying it to the study results.

Anemia and Iron Deficiency according to Feeding Practices in Infants Aged 6 to 24 Months

  • 김순기
    • Journal of Nutrition and Health
    • /
    • v.31 no.1
    • /
    • pp.96-101
    • /
    • 1998
  • The prevalence of iron deficiency in later infancy and the toddler years(25% to 40% at 1 year of age) has not decreased remarkably , except in Western countries. The purpose of this study was to 1) determine the relationship between current feeding practices and iron status, and 2) assess compliance to infant feeding instructions. Two groupsof infants were examined. The first group of 302 infants aged 6 to 24months was seen at a well baby clinic while the second group of 135 infants of the same age group was assessed by venipuncture. Cutoff values for laboratory tests were as follows ; hemoglobin<11g/dL, mean corpuscular volume (MCV) <72fl ; red cell distribution width(RDW)>15% ; serum ferritin level<10ng/ml ; and transferrin saturation (serum iron(TIBC)<10%. The diagnosis of iron deficiency anemia (IDA) was made when a low hemoglobin level was associated with either low ferritin orlow transferrin saturation . Of the 302 children brought to the well baby clinic , 12.3%(n=37) were found to have anemia (hemoglobin<11.0/dL). In terms of children grouped according to feeding practices, it was found that children with anemial comprised 32.0% (24/75) of the prolonged breast-fed group (Group A), significantly more than the 4.0%(7/176) of the artificial milk feeding group(Group B). and 3.9%(2/51) of the switched from breast milk to iron -fortified weaning foods group(Group C).Among the 107 children with IDA , iron deficiency in 105 children(98.1%) was suggested by their dietary histories ; exclusive or prolonged breast-feeding for more than 6 months without iron fortification in 98 infants ; cow's milk consumption> 500ml/day without iron fortification during infancy(n=12), or >800ml without iron-fortified foods after infancy(n=15) ; and the use of unfortified forumula or unbalanced diets, mainly limited to rice gruel. Despite the relatively high (79.6%) motivation on the part of the infants mothers and supervison by professional personnel, the poor results in the infants receiving iron fortified foods were due to poor compliance(85.75). Among the mothers of 98 IDA patients who were contacted by telephone , it was revealed that 29% did not give the oral iron preparation for more than 2 months. Furthermore, negligence or disregard by the parents occurred in 14% of the case , discontinuance of the oral iron preparation by the parents due to side effects occurred in 6%, and the children's refusal or poor oral intake and no further trial occurred in 6%. The dietary history of a large group of infants was highly predictive of their risk for anemia . Continued consumption of breast milk until the age of 1 year is not warranted unless iron-fortified foods are given concomitantly. Because there is a problem with compliance, more successful and safe strategies for preventing iron deficiency woold included dual coverage in the from of therapeutic iron supplementation as well use of iron-fortified foods for teddlers who are at risk of iron deficiency.

  • PDF

Integrating Portable Internet with cdma2000 Mobile Communication Networks for Seamless Service (연속적인 서비스를 위한 휴대 인터넷과 cdma2000 이동통신망의 연동 방안)

  • Cho Jinsung;Kim Jeong Gem
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.11B
    • /
    • pp.920-929
    • /
    • 2004
  • Nowadays, wireless packet data services are provided over cdma2000 1x/1xEV-DO mobile communication network and Portable Internet are being standardized for users demanding higher data rate services. Portable Internet can provide high data rate services, but its service coverage is relatively small. If Portable Internet may be integrated with cdma2000 mobile networks, users are able to choose the best service according to service areas and get seamless services while they are moving around. At the same time, it is cost-effective for operators to construct and maintain the integrated network. For the purpose of effectively integrating Portable Internet into cdma2000 networks, we propose an integration scheme including network architecture, protocol architecture, functions in network elements, interfaces between them, and call-flow procedures. The integration scheme proposed in this paper adopts a tightly-coupled architecture for unified authentication/accounting and seamless services. In addition, the scheme can be implemented without modifying the existing cdma2000 mobile communication networks. It is also simple to develop the dual-mode mobile station. Through the simulation results based on the performance model for handoffs between cdma2000 and Portable Internet, it has teen validated that the proposed scheme diminishes packet losses compared with the loosely-coupled architecture.

Wear and corrosion coatings by MO-PACVD and dual plasma processes (MO-PACVD 및 복합 플라즈마 공정에 의한 내마모 내식성 코팅)

  • 김선규
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.3-4
    • /
    • 1999
  • 최근 산업이 고속도화, 고능률화 및 고정멸화의 추세로 발전함에 따라 우수한 내마모성, 인성, 고온 안정성 및 내구성을 갖는 공구 및 금형을 요구하게 되었다. 그러나 이와같은 성질들은 어떤 단일 재료에서는 얻을 수 없으며 적당한 기판공구나 금혈위에 내마모성 보호피막을 coating함으로 비교적 저렴하게 얻을 수 있다. 화학증착법으로 TiC, TiN등을 증착시킬때에는 $1000^{\circ}C$정도의 반응온도가 필요하며 이러한 증착온도는 모재가 초경합금일때는 문제가 안되나 강재일 경우 모재의 연화와 칫수변화의 문제를 야기시킨다. 최근에는 플라즈마를 사용하여 증착반응온도를 $550^{\circ}C$ 이하로 낮추는 플라즈마 화학 증착볍(PACVD)이 대두되고 있다. 그러나 이 방법어서 는 뚱착하려는 금속원소가 TiCl4의 형태로 공급되고 있으므로 생성된 층이 염소를 포함하고 있다. 이 층에 잔존하는 염소는 층의 기계적 성질을 저하시키고 층내의 stress를 유발시킨다. 또한 HCI개스의 생성으로 인하여 펌프 및 장비의 부식이 촉진 된다 이러한 결점을 극복하기 위하여 금속유기화합물 전구체(metallo-organic precursor)로 $TiCl_4$를 대체하고자 하는 연구가 활발하게 진행되고 있으며 본 연구실에서 이에 대하여 연구한 결과를 소개하고자 한다. diethylamino titanium을 전구체로 사용하여 $H_2,\;N_2,\;Ar$분위기하에서 pulsed d.c.를 사용하는 MO-PACVD에 의하여 $150~250^{\circ}C$의 저온에서 Al 2024 기판에 TiCN층 형 성을 하였다. 전구체 증발온도는 $74~78^{\circ}C$의 온도범위어야 하며 고경도의 코탱층은 54% duty, 14.2kHz, 450V의 조건에서 얻어졌으며 duty, 주파수, 전압이 증가함에 따라 경도는 저하되었다. 이때의 표면 morphology를 SEM으로 조사한바 dome structure가 크게 발달되었음을 알 수 있었다. 본 실험의 온도 범위내에서 얻은 TiCN 증착반응의 활성화에너지는 7.5Kcal/mol이었다. 증착된 TiCN층은 우수한 내마모섣을 나타내었으며 스크래치테스트 결과 17N의 엄계하중을 나타내었다. 본 연구에서 변화 시킨 duty, 주파수, 전압의 범위에서는 층의 밀착력은 크게 변화하지 않았다. titanium isopropoxide를 전구체로 사용하여 Hz, Nz 분위기하에서 d.c.를 사용하는 MO-PACVD에 의하여 Ti(NCO) 코팅층을 SKDll, SKD61, SKH9 공구강에 형성시키는 공정을 개발하였다. 최적의 Ti(NCO) 코탱층을 얻기 위해 유입전구체 부피%의 양은 향착압력의 5%를 넘지 않아야 되고 수소와 젤소 가스비가 1:1일 때 가장 높은 코팅층의 경도값을 나타내었다. 수소와 질소 가스비가 3:7일 때 TiFeCr(NCO)의 복화합물 코팅층이 형성됨을 알 수 있었고 500t의 증착온도에서 얻은 Ti(NCO) 코팅층이 높은 경도값과 좋은 내식성을 나타내었다. 또한 이와같은 Ti(NCO) 코팅공정과 본 실험실에서 개발한 확산층만 형성시키는 plsma nitriding 공정을 결합하여 복합코탱층을 형성하였는데 이 복합코팅층은 고경도와 우수한 내마모성, 내식성 뿐만 아니라 10)N 이상의 뛰어난 밀착력을 나타내었다. 현재 많이 사용되고 있는 PVD법은 step coverage가 좋지 않은 점과 cost intensive p process라는 단점이 있다. MO-PACVD법은 이러한 문제를 해결할 수 있는 방법으로서 앞으로 지속적인 도전이 요구되는 분야이다.

  • PDF

Performance of Occupational Health Services by Type of Service : Cost Benefit Analysis (사업장 보건관리 사업의 형태별 수행성과 분석 -비용편익 분석을 중심으로-)

  • Cho, Tong Ran;Kim, Hwa Joong
    • Korean Journal of Occupational Health Nursing
    • /
    • v.4
    • /
    • pp.5-29
    • /
    • 1995
  • Occupational health services in Korea have been operated as dual types : one is operated by occupational health care manager and the other is health care agency without their own personnel. The performance of occupational health service should be different due to the variety of characteristics of health care manager and workplace, qualification of health care manager. This study is to analyze performance of occupational health care services with a particular consideration of job performance shape and efficiency, based on comparing those two types of health care management to show on the basic data for the settlement of more qualitative health care management system at workplace. For this study, total 391 places in Seoul and Inchon city area ; 154 places (39.4%) managed by designated health care manager and 237 places (60.6%) by the agency with their commission are selected as research samples. Tools for data collection are questionnares that have been investigated during the period of 20 September 1993-20 December 1993. Those data are compared with percentiles, mean, standard deviation and B/C ratio using SPSS PC program. Conclusions observed from the tests and each comparison could be summerized as follows : 1. Occupational health care have been accomplished at workplaces with designated people than with agencies people, and coverage rate of the occupational health care services has differences, due to management types. The reason of these results is due to visit only one or two times monthly by the agencies, while their own health care manager obsess, at the workplaces all the times. 2. Most of the expense for environmental control of all health care services expenditures shows that there is almost no fundamental improvement because more expenses are needed for procuring personal protective equipment and measuring work environment instead of environmental improvement. 3. It is investigated how much the cost of occupational health care services needs per worker, and calculated how much the cost needs per service hour per worker. The results from this show that the cost of occupational health services at workplaces with their own managers used less than the cost of health care agencies, eventually the former gives better services with less cost than the latter. 4. Benefit/Cost ratio is also produced by total benefit/total cost. The result from the above way reads 4.57 as a whole, while their own manager having workplaces reads 4.82 and the agencies do l.56. Even if their own manager performing workplaces spent more cost, this system produces more benefit than the agencies management. 5. The B/C ratio for medical organization such as local clinic, health care center and pharmacy shows more than or equal to at the workplaces controlled by the agencies. It is inferred that benefit would be much less than the cost used, with so being inefficient. 6. It is assumed that the efficiency ratio of health education is equal to reduction rate of workers medical organization visit. Estimated reduction rate 5%, 10%, 15%, show that the efficiency ratio of health education have an effect on producing benefits. It is estimated that more benefit can be produced if more qualitative education will be provided for enhancing health care efficiency. 7. Results of this study cannot be generalized because there are large scale of deviation in case of workplaces with less than 300 full time workers, but B/C ratio reads 2.69 as a whole and 3.25 at workplaces with their own health care manager are higher than 1.63 at the workplaces manged by the agencies. Finally, all the benefit concerning health care services could not be quantified, measured and shown on the value of money. This is a reason that a considerable part of benefits are so underestimated. This is also thought that measurement tools should be developed for measuring benefits of health care services with a comprehensive quantification. in the future. It is also expected that efficiency of occupational health care services should be investigated using cost-effectiveness analysis.

  • PDF