• Title/Summary/Keyword: dual composite

Search Result 217, Processing Time 0.03 seconds

Effects of surrounding and underlying shades on the color adjustment potential of a single-shade composite used in a thin layer

  • Mariana Silva Barros;Paula Fernanda Damasceno Silva;Marcia Luciana Carregosa Santana;Rafaella Mariana Fontes Braganca;Andre Luis Faria-e-Silva
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.7.1-7.10
    • /
    • 2023
  • Objectives: This study aimed to evaluate the surrounding and underlying shades' effect on the color adjustment potential (CAP) of a single-shade composite used in a thin layer. Materials and Methods: Cylinder specimens (1.0 mm thick) were built with the Vittra APS Unique composite, surrounded (dual specimens) or not (simple specimens) by a control composite (shade A1, A2, or A3). Simple specimens were also built only with the control composites. Each specimen's color was measured against white and black backgrounds or the simple control specimens with a spectrophotometer (CIELAB system). The whiteness index for dentistry (WID) and translucency parameters (TP00) were calculated for simple specimens. Differences (ΔE00) in color between the simple/dual specimens and the controls were calculated. The CAP was calculated based on the ratios between data from simple and dual specimens. Results: The Vittra APS Unique composite showed higher WID and TP00 values than the controls. The highest values of ΔE00 were observed among simple specimens. The color measurements of Vittra APS Unique (simple or dual) against the control specimens presented the lowest color differences. Only surrounding the single-shade composite with a shaded composite barely impacted the ΔE00. The highest CAP values were obtained using a shaded composite under simple or dual specimens. Conclusions: The CAP of Vittra APS Unique was strongly affected by the underlying shade, while surrounding this composite with a shaded one barely affected its color adjustment.

Dual-Band Stop Filter Using Metamaterial TLs (Metamaterial 전송선을 이용한 이중 대역 저지 필터)

  • Oh, Hee-Seok;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.2
    • /
    • pp.124-128
    • /
    • 2009
  • This raper proposes a dual-bandstop filter, which is based on a metamaterial transmission line using the composite right/left-handed (CRLH) and dual composite right/left-handed (D-CRLH) structures. The metamaterial structure is used for miniaturization and dual-bandstop operation at the TDMB frequency range (195 MHz) and DVB-T/H frequency range (670 MHz). The size of the proposed filter is $30{\times}15\;mm$, and the -10 dB bandstop fractional bandwidth is approximately 73 % and 50 % at each frequency, respectively.

Homogeneous Dual Composite Right/Left-Handed Metamaterial Using Subwavelength Defected Ground Structure(DGS) (Subwavelength 결함접지구조(defected grounded structure : DGS)를 이용한 Homogeneous Dual Composite Right/Left-Handed 메타물질 구현)

  • Park, Woo-Young;Lim, Sung-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2242-2246
    • /
    • 2009
  • In this paper, a homogeneous dual composite right/left-handed (D-CRLH) transmission line (TL) is proposed by using a defected ground structure (DGS) on the ground plane. In order to satisfy a homogeneity condition of metamaterial, a subwavelength unit cell is designed by way of a spiral DGS and a meander stub. From a dispersion diagram, it is expected that the frequency bands for the left-handed (LH) property is 3.5 - 4.4 GHz. At 3.8 GHz in the LH band, backward propagating phenomenon is observed from full-wave analysis. The experimental results show that the proposed TL has a stop-band in 1.75 - 3.6 GHz.

THE MICROHARDNESS OF RESTORATIVE COMPOSITE AND DUAL-CURED COMPOSITE CEMENT UNDER THE PRECURED COMPOSITE OVERLAY (아르곤레이저를 이용한 레진인레이 하부의 레진 시멘트 및 광중합형 복합레진 중합)

  • Park, Sung-Ho;Lee, Chang-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.109-115
    • /
    • 2000
  • This study was designed to evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay. For restorative materials, Z100 and Tetric Ceram were used. For dual cured composite cements, Variolink II((VL II) of three consistency (low, high, ultra high) were used. To determine the optimal microhardness of Z100, Tetric Ceram and Variolink II, each material was packed into the 1mm thickness teflon mold without composite overlay and light cured for 60 seconds. Then the microhardnesses of each sample were measured, averaged and regarded as optimal hardness of each material. To evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay, the composites were packed into 1mm thickness teflon mold, coverd with celluloid strip, and then precured composite overlay which was made of Targis(Ivoclar/Vivadent, Liechtenstein) was positioned. 2 types of visible light curing machine, the power density of one of which was 400$mW/cm^2$ and the other was 900$mW/cm^2$, and one type of argon laser were used to cure the restorative composite and dual cured cement. For each group, 10 sample were assigned. The light curing tip was positioned over the composite overlay and light cured for 1min., 2min. or 3min with visible light curing machine or 15sec, 30 sec, 45sec, and 60 sec with argon laser. The Vickers hardnesses of upper and lower surface of Z100, Tetric Ceram, and 3 types of VL II cement were measured. When the 900 $mW/cm^2$ curing light was used, 2min. was needed for optimal curing of Z100 and Tetric Ceram. Variolink II did not be cured optimally even though the curing time was extended to 3min. When 400$mW/cm^2$ curing light was used, 3min. was necessary for Z100, whereas 3min. was not enough for Tetric Ceram. Variolink II was not cured optimally even though the curing time was extended to 3min. When argon laser was used, Z100, Tetric Ceram and Variolink II were not cured optimally in 60 seconds.

  • PDF

Cementation technique in indirect tooth colored restoration

  • Park, Sung-Ho
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.595-595
    • /
    • 2001
  • As the interest for esthetic restoration is increasing, the usage of composite resin is increasing. The usage of composite resin is not limited to anterior teeth but is spreading to posterior area using direct & indirect methods. Generally, dual or chemical cure resin cement has been used for setting composite or porcelain inlay restoration. However, chemical cure resin cement has limited working time and it's difficult to remove excess cement from the tooth and the restoration. The dual cured composite is also difficult to remove from the tooth surface.(omitted)

  • PDF

Evaluation of the Color Adjustment Potential of Single-Shade Composite Resin in Primary Teeth (유치에서의 단일 색조 복합레진의 색조 적응력 평가)

  • Yongsoon Kim;Howon Park;Juhyun Lee;Haeni Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.113-120
    • /
    • 2023
  • Restoring composite resins with the optimal shades for all primary teeth is a great challenge for pediatric dentists. A newly developed single-shade composite resin can exhibit a color similar to that of the surrounding tooth structure based on the structural color phenomenon. This study aims to evaluate the color adjustment potential (CAP) of a single-shade composite resin compared to conventional multi-shade composite resins in primary teeth. A single-shade composite resin and two conventional multi-shade composite resins were included in this study. Two types of specimens, a single specimen and a dual specimen, were evaluated. For single specimens, duplications of the primary second molar denture teeth were made using experimental composite resins. For dual specimens, cavities were prepared on the buccal surfaces of extracted primary second molars and restored with experimental composite resins. The L*, a*, and b* values were measured using a colorimeter for the extracted teeth and specimens. The mean ΔEab* values for single and dual specimens and CAP were calculated. Bonferroni post-hoc analysis was performed to confirm the statistical significance between the ΔEab* and CAP values of the experimental resins. Among the single specimens, the single-shade composite resin showed significantly higher ΔESingle compared to other composite resins (p < 0.0167). There was no significant difference between ΔEDual for all experimental resins. The single-shade composite resin showed highest CAP compared to other multi-shade composite resins. A single-shade composite resin exhibited the most prominent color adaptability compared to other conventional multi-shade composite resins for primary second molars. A single-shade composite resin can simplify shade matching and provide esthetic outcomes for the restoration of primary second molars.

Analysis of Strain Distribution According to Change in the Vacancy Shape of the Lightweight Dual-Phase Structure (경량화된 이중상 구조의 중공 형태 변화에 따른 변형률 분포 분석)

  • Lee, J.A.;Kim, Y.J.;Jeong, S.G.;Kim, H.S.
    • Transactions of Materials Processing
    • /
    • v.31 no.5
    • /
    • pp.267-272
    • /
    • 2022
  • A dual-phase structure refers to a material with two different phases of components or crystal structures. In this study, we analyze the stress distributions for harmonic and composite structured materials which are a kind of dual-phase structure materials. The finite element method (FEM) was used to progress compression test to analyze the strain distribution, and rather than constituted of a fully dense material, a dual-phase structure was designed to make a lightweight structure that has different shapes and volumes of vacancy in each case. As a result of each case, the dual-phase structured materials showed different stress distribution patterns and based on this, the cause was identified through the research.

Dual-Wideband Bandpass Filter Using Distributed Composite Right/Left-Handed Transmission Line Quad-Mode Resonators (분산 CRLH 전송선로 4중 모드 공진기를 이용한 이중-광대역 대역통과 여파기 설계)

  • Sung, Gyuje;Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.84-89
    • /
    • 2017
  • This paper presents a dual-wideband bandpass filter (BPF) with high band-to-band isolation and skirt selectivity using distributed composite right/left-handed (CRLH) transmission line (TL) quad-mode resonators (QMRs). The results of the proposed distributed CRLH TL unit cell analysis are used to establish the scattering parameters and the resonance frequencies of the QMR constituting the dual-wideband BPF. A novel dual-wideband bandpass filter is designed and fabricated, using the derived scattering characteristics. The measured results show that the fabricated dual-wideband bandpass filter has an insertion loss of less than 1.08dB in the lower band, and of 2.01dB in the upper band, a bandwidth of 2.8-5.52GHz and 9.68-12.26GHz, and a band-to-band isolation of more than 38dB, from 6.34-8.42GHz.

Study of a Dual-band RF switch using a Composite Right/Left Handed Transmission Line and PIN Diode (Composite Right/Left Handed 전송선과 PIN 다이오드를 이용한 이중대역 RF 스위치 연구)

  • Park, Chang-Hyun;Choi, Byung-Ha;Shin, Dong-Ryul;Seong, Won-Mo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.11
    • /
    • pp.55-60
    • /
    • 2008
  • This paper proposed a dual-band RF switch using a Composite Right/Left Handed transmission line(CRLH TL) and PIN diode. RF switch is usually consist of $\lambda/4$ Right Handed transmission line(RH TL) and PIN diode. The dual band characteristics of RF switch was achieved by using CRLH transmission line instead of RH transmission line. CRLH Open-Stub was designed for resolve to reduction of isolation due to Package Inductance of PIN diode. The proposed RF switch was designed at GSM and DCS frequency-band. The measurement results showed a good agreement with theoretical result.

Design of A Dual Band Branch Line Coupler Using a CRLH Transmission Line Structure (CRLH 전송선로 구조를 이용한 이중대역 브랜치 라인 커플러 설계)

  • Park, Min-Woo;Koo, Ja-Kyung;Lim, Jong-Sik;Jeong, Yong-Chae;Ahn, Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2462-2467
    • /
    • 2009
  • This paper proposes a dual band branch line coupler (BLC) using a composite right/left handed (CRLH) transmission line. The existing dual band BLCs with open stubs require hundreds of line impedance for the open stub as the frequency bands approach to each other, so it has been almost impossible to realize them. However in the proposed BLC, a CRLH transmission line replaces the open stub with an extremely high line impedance so that the BLC circuit may be realized even two frequencies are close to each other. As an example, a dual band BLC operating at 1800MHz and 2300MHz (the frequency ratio is 1:1.28) is designed and measured. Open stubs with $560\Omega$ line impedance are replaced by CRLH transmission lines for realizing the dual band BLC. The measured performances prove that the dual band operation is well acceptable and the proposed design method is successful even the ratio between two frequencies is not around two nor more.