• Title/Summary/Keyword: dual

Search Result 9,541, Processing Time 0.039 seconds

A Comparative Study of Influencing BMD Factors in Postpartum and General Women in Their Twenties and Thirties ($20{\sim}30$대 여성의 골밀도 영향 인자에 대한 출산 후 여성과 일반여성과의 비교 연구)

  • Kim, Sun-Geun;Oh, Chan-Ho;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.25-32
    • /
    • 2007
  • This study is to evaluate the factors that affect to the bone mineral density(BMD) of postpartum women by comparing BMD between postpartum and general women who are ages from 20 to 39, and to identify correlation between various factors weight, height, body mass index(BMI), hemoglobin(Hb) and BMD. Study subjects were postpartum(n=159) and general(n=180) women. We checked the BMD of femoral neck and lumbar spine by using dual energy X-ray bone densitometry. The mean age was $30.69{\pm}3.32$ in postpartum care group and $31.22{\pm}5.66$ in general women group. In postpartum care group, the mean BMD of femoral neck and lumbar spine were -0.187 and -0.076. In general women group, the mean BMD of femoral neck and lumbar spine were -0.029, and -0.169. According to BMI level, each group was divided into two subgroups. One was 23 or more BMI subgroup, and the other was under 23 BMI subgroup. There was a significant difference in BMD of femoral neck and lumbar spine between two subgroups in general women group, but only a significant difference in BMD of lumbar spine is noted between two subgroups of postpartum group. According to Hb level, each group was divided into two subgroups. One was 11g/dl or more subgroup, and the other was under 11g/dl subgroup. There was not a statistically significant difference of BMD in all subgroups. BMD of femoral neck and lumbar spine showed a significant correlation with weight, height, BMI in both groups. There was a significant correlation between BMD and Hb level in postpartum care group, but a significant correlation was not noted in general women group. The postpartum women showed a significant correlation between BMD and various factors such as weight, height, BMI just like in general women. There was a significant correlation between BMD and Hb in postpartum women, but not in general women.

  • PDF

Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator (CLINAC 1800 선형가속기의 15 MV X-선의 특성)

  • Kim, Kye-Jun;Lee, Jong-Young;Park, Kyung-Ran
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.131-141
    • /
    • 1991
  • A comprehensive set of dosimetric measurements has been made on the Varian Clinac 1800 15 MV photon beam. Beam quality, percentage depth dose, dose in the build up region, output, symmetry and flatness, transmission through iead (Cerrobend), tray attenuation, isodose curves for the open and wedged fields were measured using 3 dimensional water phantom dosimetry system (including film densitometer system) and polystyrene phantoms. These dosimetric measurements sufficiently characterized the beam to permit clinical use. The depth dose characteristics of photon beam is $d_{max}$ of 3.0 cm and percentage depth dose of $76.8\%$ at 10 cm,100 cm source-surface distance, field size of $10\times10\;cm^2$ for 15 MV X-ray beam. The Output factors ranged 0.927 for $4\times4\;cm^2$ field to 1,087 for $35\times35\;cm^2$ field. The build-up level of maximum dose was at 3.0 cm and surface dose was approximately $15.5\%$ for a field size $10\times10\;cm^2$ The stability of output is $within\pm1\%$ and flatness and symmetry are $within\pm3\%$. The half value thickness (HVL) of lead is 13 mm, which corresponds to an attenuation coefficient of $0.053\;mm^{-1}$. These figures compare facorably with the manufacturesr`s specifications.

  • PDF

A STUDY ON THE BOND STRENGTHS BETWEEN GLASS IONOMER CEMENT BASES AND COMPOSITE RESINS (글래스 아이오노머 이장재와 복합레진간의 결합강도에 관한 연구)

  • Kim, Min-Hee;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.520-527
    • /
    • 1999
  • For the purpose of providing some suggestions in selection of filling materials used in 'sandwich technique', the bond strengths between glass ionomer cement bases and composite resins were investigated and compared. For lining materials, 'Vitrebond' and 'Ketac-fil' were used. Using these two as bases, 10 of each following resins were built up on the top ; Z-100 (light curing resin) Clear-fil (chemical curing resin), Bis-core (dual cure resin), Dyract (compomer), therfore 10 specimens of each group and total of 80 specimens were made. After storing specimens in $37^{\circ}C$ deionized water for 24 hours, the shear bond strengths were measured under universal testing machine with 50 kg of full load scale and 1mm/min of cross-head speed and obtained the results as follows : 1. Over Vitrebond base, Z-100 showed the lowest bond strength but the other three did not show any difference in bond strength. 2. Over Ketac-fil base, Clear-fil showed the highest bond strength followed by Dyract, Bis-core, and Z-100 showed the lowest bond strengths. 3. Whereas Clear-fil showed the similar bond strengths on the Vitrebond base as other resins, it showed the highest bond strength on Ketac-fil base, which showed some difference in bond strength by differing GIC bases. 4. The bond strengths between base materials and composite resin showed a stronger resin-dependence tendency in cases with Ketac-fil bases rather than with Vitrebond bases.

  • PDF

Association of Bone Mineral Density with Physiological Characteristics and Lifestyles in Premenopausal Working Women (폐경전 성인직장여성의 골밀도와 생리적 특성 및 생활습관과의 관련성)

  • 임화재
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.2
    • /
    • pp.339-348
    • /
    • 2004
  • This study was peformed to assess the relationships among bone mineral density (BMD), Physiological characteristics and lifestyle factors in 61 premenopausal working women aged 30∼49 y in Busan. The BMDs of the lumbar spines (Ll∼L4), femoral necks (FN), ward's triangles (WT) and trochanters (TC) were measured by dual energy X-ray absorptiometry. Data for physiological characteristics and physical activity was assessed by questionnaire and usual intakes of coffee, green tea, alcohol, Coca cola by food frequency questionnaire. The BMDs of L14, FN, WT and TC were 1.02 g/$\textrm{cm}^2$, 0.76 g/$\textrm{cm}^2$,0.69 g/$\textrm{cm}^2$ and 0.66 g/$\textrm{cm}^2$respectively The BMD of FN was assessed as osteopenia by T-score. The BMD of WT was positively correlated with age of monarch (p<0.05) and the BMD of Ll4 was positively correlated with delivery number (p<0.05). The BMD of Ll4 was positively correlated with hours of outdoor activity per weekend and week (p<0.05, p<0.05). The BMDs of FN and WT (p<0.05, p<0.05) were positively correlated with intake of green tea per month and the BMD of FN (p<0.05) was positively correlated with intake of wine per month. But the BMD of Ll (p<0.05) was negatively correlated with intake of Coca cola per month. So nutritional education for increasing hours of outdoor activity and decreasing intake frequency of beverage contributing to diminishment of bone mineral density is needed for premenopausal working women to prevent osteoporosis.

A study on the origination and Transmission of Yu in Northeast Asia. -from the 4th Century to the 8th Century- (동북(東北)아시아 유의 기원(起源)과 그 교류(交流)에 관(關)한 연구(硏究) -$4{\sim}8$세기(世紀)를 중심(中心)으로-)

  • Cho, Sun-Hee;Park, Kyung-Ja
    • Journal of the Korean Society of Costume
    • /
    • v.17
    • /
    • pp.29-43
    • /
    • 1991
  • Yu was a type of dress worn on the upper part of the body which was commonly used in Northeast Asia. It was originally used by the Northern race for the need of courtesy as well as protecting cold. It was believed that Yu in Northeast Asia, which was called Kaftan, was came from Scythai lived in North Eurasian land around the Black sea. Scythians were the first-formed horse-riding race in the world and their civilization influenced those of far Asiatic sector along the steppe route. As their power expanded, their costume culture transmitted to the East(China, Korea, Japan). The upper garment, Yu, was characterized by the left-sided collars, narrow sleeves belted at the waist to the length of the hip line and the tight trouser on the lower part, which we commonly called HoBok(胡服) style. 1. Yu in Northeast Asia was originated from the Eurasians, Scythian Culture. Being exchanged, active style costumes were widely used among Chinese, Koreans and Japanese throughout centuries' including $4{\sim}8$ century. 2. Chinese Yu had a style of wide-sleeves and right-sided collars. The traditional costumes of Han race are consisted of wide-sleeved Yu on the upper and long-skirt on the lower part of the body. Before the adoptation of HoBok during reign of King Jo Mooryung in 307. B.C., HoBok style had already found in the remains since the Sang period. There were various names among Yu during the Han period. Seup, Sean Eui, Kye, Kyu were one of the styles and several names were meant for collar and sleeves. During $4{\sim}8$ centuries, clothes of right-sided collar were found, superior to that of left-sided and narrow sleeves were widely used both the royal and the humble. Various styles of decoration were seen in Yu around neck, back and sleeves comparing other nations. 3. Yu, in Korea, was typical style of Northern-bound HoBok. Both men and women had similarity in Yu style, narrow sleeves, left-sided collar, belted at the waist and to the length of hip line. Influenced by Han race, in the $4th{\sim}8th$ centuries, dual system of collar was found. But we cannot see major change in Yu and finally was connected to the present. 4. The original design of the Japanese costumes was not similar to that of Northern nomadic hunting race, which was suitable for horse-riding activities. Owing to the climates along the island, we could see various conditions ranging from the cold and to the warm. Influenced by the climates, pulling over the neck(Pancho style) were major design in Japan. As Korea was advanced earlier than Japan, Korean landed Japanese territory showing clothes. So primitive costumes had changes in style. During the $4th{\sim}8th$ period. The Korean mode was found in Haniwa (which was built to make sacrifices to the dead King) and costumes in Jeong Chang Won. Among the costumes in Jeong Chang Won, we put 3 or more costumes to the category of Yu characterizing elements of Korea and Tang period. From the $4th{\sim}8th$ century, China, Korea, Japan fell into the same cultural category, Scythai. Styles in Yu among three nations, we saw little differences, basically along times. Originated from the West Asia, Yu was transmitted to the far East changing Chinese costumes, Koreans melted it into the traditional elements and then influenced Japan.

  • PDF

Reference Values of Functional Parameters in Gated Myocardial Perfusion SPECT : Comparison with $QGS^{\circledR}$ and $4DM^{\circledR}$ Program (게이트 심근 관류 스펙트의 심기능 지표의 정상 참고값 : $QGS^{\circledR}$ 프로그램과 $4DM^{\circledR}$ 프로그램의 비교)

  • Jeong, Young-Jin;Park, Tae-Ho;Cha, Kwang-Soo;Kim, Moo-Hyun;Kim, Young-Dae;Kang, Do-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.430-437
    • /
    • 2005
  • Purpose: The objectives of this study were - First, to determine the normal range of left ventricular end diastolic volume (EDV), end systolic volume (ESV) and election fraction (EF) from gated myocardial perfusion SPECT for Quantitative Gated SPECT (QGS) and 4D-MSPECT (4DM), respectively. Second, to evaluate the relationships between values produced by both software packages. Materials & Methods: Tc-99m MIBI gated myocardial perfusion SPECT were performed for 77 patients (mean age: $49.6{\pm}13.7y$, n=37(M), 40(F)) with a low likelihood (<10%) of coronary artery disease (CAD) using dual head gamma camera (E.CAM, Siemens, USA). Left ventricular EDV, ESV and EF were automatically measured by means of QGS and 4DM, respectively. Results: in QGS, the mean EDV, ESV and EF for all patients were $78.2{\pm}25.2ml,\;27.4{\pm}12.9ml\;and\;66.6{\pm}8.0%$ at stress test respectively, not different from rest test (p>0.05). In 4DM, the mean EDV, ESV and EF for all patients were $89.1{\pm}26.4ml,\;29.1{\pm}12.8ml\;and\;68.5{\pm}6.7%$ at stress test. Most cases in 4DM, there was no significant difference statistically between stress and rest test (p>0.05). But statistically significant difference was found in EF ($68.5{\pm}6.7%$ at stress vs $70.9{\pm}8.0%$ at rest, p<0.05). Correlation coefficients between the methods for EDV, ESV and EF were comparatively high (0.95, 0.93, 0.71 at stress test and 0.95, 0.90, 0.69 at rest test, respectively). However, Bland-Altman plots showed a large range of the limit value of agreement for EDV, ESV and EF between both methods ($-30ml{\sim}10ml,\;-12ml{\sim}8ml,\;-14%{\sim}11%$ at stress test and $-32ml{\sim}5ml,\;-13ml{\sim}13ml,\;-18%{\sim}12%$ at rest test). Conclusion: We found the normal ranges of EDV, ESV and EF for patients with a low likelihood of CAD in both methods. We expect these values will be a good reference to interpret gated myocardial perfusion SPECT. Although good correlation was observed between both methods, they should not be used interchangeably. Therefore, when both programs are used at the same site, it will be important to apply normal limits specific to each method.

Increases in Doxorubicin Sensitivity and Radioiodide Uptake by Transfecting shMDR and Sodium/Iodide Symporter Gene in Cancer Cells Expressing Multidrug Resistance (다약제내성 암세포에서 shMDR과 Sodium/Iodide Symporter 유전자의 이입에 의한 Doxorubicin 감수성과 방사성옥소 섭취의 증가)

  • Ahn, Sohn-Joo;Lee, Yong-Jin;Lee, You-La;Choi, Chang-Ik;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, In-Kyu;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.209-217
    • /
    • 2007
  • Purpose: Multidrug resistance (MDR) of the cancer cells related to mdr1 gene expression can be effectively treated by selective short hairpin RNA for mdr1 gene (shMDR). Sodium/iodide symporter (NIS) gene is well known to have both reporter and therapeutic gene characteristics. We have co-transfected both shMDR and NIS gene into colon cancer cells (HCT15 cell) expressing MDR and Tc-99m sestamibi and I-125 uptake were measured. In addition, cytotoxic effects of doxorubicin and I-131 therapy were also assessed after transfection. Material and Methods: At first, shMDR was transfected with liposome reagent into human embryonic kidney cells (HEK293) and HCT cells. shMDR transfection was confirmed by RT-PCR and western blot analysis. Adenovirus expressing NIS (Ad-NIS) gene and shMDR (Ad-shMDR) were co-transfected with Ad-NIS into HCT15 cells. Forty-eight hours after infection, inhibition of P-gycoprotein (Pgp) function by shMDR was analyzed by a change of Tc-99m sestamibi uptake and doxorubicin cytotoxicity, and functional activity of induced NIS gene expression was assessed with I-125 uptake assay. Results: In HEK293 cells transfected with shMDR, mdr1 mRNA and Pgp protein expressions were down regulated. HCT15 cells infected with 20 MOI of Ad-NIS was higher NIS protein expression than control cells. After transfection of 300 MOI of Ad-shMDR either with or without 10 MOI of Ad-NIS, uptake of Tc-99m sestamibi increased up to 1.5-fold than control cells. HCT15 cells infected with 10 MOI of Ad-NIS showed approximately 25-fold higher I-125 uptake than control cells. Cotransfection of Ad-shMDR and Ad-NIS resulted in enhanced cytotoxic by doxorubicin in HCT15 cells. I-131 treatment on HCT15 cells infected with 20 MOI of Ad-NIS revealed increased cytotoxic effect. Conclusion: Suppression of mdr1 gene expression, retention of Tc-99m sestamibi, enhanced doxorubicin cytotoxicity and increases in I-125 uptake were achieved in MDR expressing cancer cell by co-transfection of shMDR and NIS gene. Dual therapy with doxorubicin and radioiodine after cotransfection shMDR and NIS gene can be used to overcome MDR.

Development of a Modular Clothing System for User-Centered Heart Rate Monitoring based on NFC (NFC 기반 사용자 중심의 모듈형 심박측정 의류 시스템 개발)

  • Cho, Hakyung;Cho, SangWoo;Cho, Kwang Nyun
    • Science of Emotion and Sensibility
    • /
    • v.23 no.2
    • /
    • pp.51-60
    • /
    • 2020
  • This study aimed to develop a modular smart clothing system for heart rate monitoring that reduces the inconvenience caused by battery charging and the large size of measurement devices. The heart rate monitoring system was modularized into a temporary device and a continuous device to enable heart rate monitoring depending on the requirement. The temporary device with near-field communication (NFC) and heart rate sensors was developed as a clothing attachment type that enables heart rate monitoring via smart phone tagging when required. The continuous device is based on Bluetooth Low Energy (BLE) communication and batteries and was developed to enable continuous heart rate measurement via a direct connection to the temporary device. Furthermore, the temporary device was configured to connect with a textile electrode made of a silver-based knitted fabric designed to be located below the pectoralis major muscle for heart rate measurement. Considering the user-experience factors, key functions, and the ease of use, we developed an application to automatically log through smart phone tagging to improve usability. To evaluate the accuracy of the heart rate measurement, we recorded the heart rate of 10 healthy male subjects with a modular smart clothing system and compared the results with the heart rate values measured by the Polar RS800. Consequently, the average heart rate value measured by the temporary system was 85.37, while that measured by the reference device was 87.03, corresponding to an accuracy of 96.73%. No significant difference was found in comparison with the reference device (T value = -1.892, p = .091). Similarly, the average heart rate measured by the continuous system was 86.00, while that measured by the reference device was 86.97, corresponding to an accuracy of 97.16%. No significant difference was found in terms of the heart rate value between the two signals (T value = 1.089, p = .304). The significance of this study is to develop and validate a modular clothing system that can measure heart rates according to the purpose of the user. The developed modular smart clothing system for heart rate monitoring enables dual product planning by reducing the price increase due to unnecessary functions.

The Comparison of Glomerular Filteration Rate by Kidney Depth in Dynamic kidney Scan (동적신장검사에서 신장깊이에 따른 사구체여과율 비교)

  • Hwang, Ju-Won;Lim, Young-Hyen;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Mu-Seok;Jung, Ji-Uk;Park, Se-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.73-77
    • /
    • 2014
  • Purpose Find out about the significance of the GFR values calculated by the kidney depth is measured by comparing the values obtained for kidney depth was measured GFR in the CT image kidney depth and is calculated by Tonnesen law in $^{99m}Tc$-DTPA dynamic kidney scan with each applies. Materials and Methods Among patients with normal value (75~120 mL/min) computed GFR conducted of dynamic renal scan to visit from February 2013 to February 2014 and donor GFR values in patients with normal value. The mean age was 46.9 years with 14 men 13 females. We used abdomen CT image which checked before conducting dynamic Kidney scan for measuring the depth of kidney. We only used CT image that contains renal hilum and measured outermost front of the kidney from the skin surface (a) and the final surface (b) caculated the average depth of [(a + b) / 2] respectively. Using the same ROI in order to limit the change in GFR values by the other additional element was set before and after the depth value was excluded from the GFR falls kidney disease. Results Using Tonnesen law the average value was caculated 5.94 cm from the right kidney 5.90 cm from the left kidney. It was 6.83 cm, 8.71 cm in the left kidney and the right kidney average value of the depth measured on the basis of the CT image. The respective increase in left kidney 0.93 cm and right kidney 2.77 cm calculated on the basis of CT image actually measured values. GFR was calculated as the average depth of the subject calculated by the method Tonnesen $83.3{\pm}9.79mL/min$. $98.6{\pm}14.07mL/min$ GFR was applied to calculate the average depth of the subjects using the CT image, is the difference appears 15.26 mL/min was increased after seting up depth value, P value was less than 0.01 which is significant. Conclusion The difference between GFR before-after setting up depth value cause that the different of depth value. Is a measured depth of the extension value of the calculated estimates Whereas Tonnesen kidney depth method is to use in calculating the value of GFR in a typical dynamic elongation test depth derived using the CT image depth. Is thought to be able to calculate more accurately the GFR value by the distance to the center of kidney more accurately measured in the skin thereby.

  • PDF

A Pilot Study of Evaluating the Reliability and Validity of Pattern Identification Tool for Insomnia and Analyzing Correlation with Psychological Tests (불면증 변증도구 신뢰도와 타당도 평가 및 심리검사와의 상관성에 대한 초기연구)

  • Jeong, Jin-Hyung;Lee, Ji-Yoon;Kim, Ju-Yeon;Kim, Si-Yeon;Kang, Wee-Chang;Lim, Jung Hwa;Kim, Bo Kyung;Jung, In Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.31 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • Objectives: The purpose of this study was to evaluate the reliability and validity of the instrument on pattern identification for insomnia (PIT-Insomnia) and verify the correlation between PIT-Insomnia and psychological tests. Methods: Two evaluators examined the pattern identification of the participants who met insomnia disorder diagnostic criteria of the Diagnostic and Statistical Manual of Mental Disorder, Fifth Edition (DSM-5) and took the Insomnia Severity Index (ISI) score over 15 once manually and twice using the PIT-Insomnia to measure the inter-rater and test-retest reliability. We also conducted the following surveys: the Pittsburgh Sleep Quality Index (PSQI), the Korean version of Beck's depression inventory (K-BDI), the Korean version of the State-Trait Anxiety Inventory (STAI-K), the Korean Symptom checklist-95 (KSCL-95), and the EuroQol-5 dimension (EQ-5D), to measure concurrent validity and correlation between the PTI-Insomnia and psychological tests. Results: 1. The test-retest reliability analysis of the pattern identification results showed moderate agreement, and test-retest reliability analysis of each pattern identification score showed agreements from poor to moderate. 2. The inter-rater reliability analysis of the pattern identification results via manual showed slight agreement, when analysis was performed with calibration, the inter-rater reliability analysis of the pattern identification results via manual showed fair agreement. 3. The concordance analysis between results via manual and the PIT-Insomnia showed poor agreement, when the analysis was performed with calibration, concordance analysis showed fair agreement. 4. The concordance analysis between the PIT-Insomnia and the PSQI showed positive linear correlation. 5. The concordance analysis between the PIT-Insomnia and the PSQI, K-BDI, STAI-K, KSCL-95, and EQ-5D showed that non-interaction between the heart and kidney have positive linear correlation with the K-BDI, anxiety item of KSCL-95, dual deficiency of the heart-spleen have positive linear correlation with somatization item of KSCL-95, paranoia item of KSCL-95, heart deficiency with timidity have positive linear correlation with stress vulnerability item of KSCL-95, parania item of KSCL-95, phlegm-fire harassing the heart have positive linear correlation with K-BDI, paranoia item of KSCL-95, depressed liver qi transforming into fire have positive linear correlation with the anxiety item of KSCL-95, parania item of KSCL-95, all pattern identification have negative linear correlation with EQ-5D. Conclusions: The PIT-Insomnia has moderate agreement of reliability and reflects the severity of insomnia since it has some concurrent validity with the PSQI. There are some correlations between the PTI-Insomnia with specific psychological tests, so we could suggest it can be used appropriately in the clinical situation.