• 제목/요약/키워드: drying speed control

검색결과 25건 처리시간 0.021초

접착강화제 도포후 인공타액에 오염된 표면의 처리방법에 따른 복합레진의 번연누출과 전단결합강도 (MARGINAL MICROLEAKAGE AND SHEAR BOND STRENGTH OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF ARTIFICIAL SALIVA-CONTAMINATED SURFACE AFTER PRIMING)

  • 조영곤;고기종;이석종
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.46-55
    • /
    • 2000
  • During bonding procedure of composite resin, the prepared cavity can be contaminated by saliva. In this study, marginal microleakage and shear bond strength of a composite resin to primed enamel and dentin treated with artificial saliva(Taliva$^{(R)}$) were evaluated. For the marginal microleakage test, Class V cavities were prepared in the buccal surfaces of fifty molars. The samples were randomly assigned into 5 groups with 10 samples in each group. Control group was applied with a bonding system (Scotchbond$^{TM}$ Multi-Purpose plus) according to manufacture's directions without saliva contamination. Experimental groups were divided into 4 groups and contaminated with artificial saliva for 30 seconds after priming: Experimental 1 group ; artificial saliva was dried with compressed air only, Experimental 2 group ; artificial saliva was rinsed and dried. Experimental 3 group ; cavities were etched with 35% phosphoric acid for 15 seconds after rinsing and drying artificial saliva. Experimental 4 group ; cavities were etched with 35% phosphoric acid for 15 seconds and primer was reapplied after rinsing and drying artificial saliva. All the cavities were applied a bonding agent and filled with a composite resin (Z-100$^{TM}$). Specimens were immersed in 0.5% basic fuschin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from one specimen. Degree of marginal leakage was scored under stereomicroscope and their scores were averaged from four sections. The data were analyzed by Kruscal-Wallis test and Fisher's LSD. For the shear bond strength test, the buccal or occlusal surfaces of one hundred molar teeth were ground to expose enamel(n=50) or dentin(n=50) using diamond wheel saw and its surface was smoothed with Lapping and Polishing Machine(South Bay Technology Co., U.S.A.). Samples were divided into 5 groups. Treatment of saliva-contaminated enamel and dentin surfaces was same as the marginal microleakage test and composite resin was bonded via a gelatin capsule. All specimens were stored in distilled water for 48 hours. The shear bond strengths were measured by universal testing machine (AGS-1000 4D, Shimaduzu Co., Japan) with a crosshead speed of 5 mm/minute. Failure mode of fracture sites was examined under stereomicroscope. The data were analyzed by ANOVA and Tukey's studentized range test. The results of this study were as follows : 1. Enamel marginal microleakage showed no significant difference among groups. 2. Dentinal marginal microleakages of control, experimental 2 and 4 groups were lower than those of experimental 1 and 3 groups (p<0.05). 3. The shear bond strength to enamel was the highest value in control group (20.03${\pm}$4.47MPa) and the lowest value in experimental 1 group (13.28${\pm}$6.52MPa). There were significant differences between experimental 1 group and other groups (p<0.05). 4. The shear bond strength to dentin was higher in control group (17.87${\pm}$4.02MPa) and experimental 4 group (16.38${\pm}$3.23MPa) than in other groups, its value was low in experimental 1 group (3.95${\pm}$2.51 MPa) and experimental 2 group (6.72${\pm}$2.26MPa)(p<0.05). 5. Failure mode of fractured site on the enamel showed mostly adhesive failures in experimental 1 and 3 groups. 6. Failure mode of fractured site on the dentin did not show adhesive failures in control group, but showed mostly adhesive failure in experimental groups. As a summary of above results, if the primed tooth surface was contaminated with artificial saliva, primer should be reapplied after re-etching it.

  • PDF

지르코니아 코어의 표면처리 방법에 따른 도재 축성의 전단결합강도 (Shear Bond Strength of Veneering Ceramic and Zirconia Core according to the Surface Treatments)

  • 신천호;황성식;한경순
    • 치위생과학회지
    • /
    • 제13권4호
    • /
    • pp.487-492
    • /
    • 2013
  • 본 연구는 지르코니아 코어 표면처리 방법에 따른 코어와 도재와의 결합기전을 파악하여 도재 수복물의 문제점을 개선하고자 도재와 동일한 구조의 코어를 제작한 후 코어 표면의 거칠기 처리와 liner 적용 방법을 각각 달리한 4개 군의 전단결합강도의 차이를 분석한 바 다음과 같은 결론을 얻었다. 1. 코어의 표면 거칠기 처리 여부는 표면조도에 영향을 주었다(p<0.001). 2. 지르코니아 코어 표면을 표면 거칠기와 liner를 도포한 군(SLT군)이 23.19 MPa로 가장 높았고, 표면 거칠기만 적용한 군(ST군)이 21.17 MPa였으며, liner만 적용한 군(LT군)은 20.53 MPa였고, 표면 비처리 군(NT군)이 16.46 MPa으로 가장 낮은 값을 나타내(p=0.176) 표면처리에 따른 전단 결합강도에 차이가 있을 가능성을 나타냈다. 또한 표면 거칠기와 liner를 도포한 군(SLT군)과 표면 비처리 군(NT군)에서 두 군 간의 차이는 통계적으로 유의하였다(p<0.05). 3. 계면상태는 SLT군이 ST군과 LT군, NT군에 비해 도재결합의 응집된 상태를 나타냈다. 코어의 표면처리 특히 거칠기 처리는 지르코니아 코어와 도재의 물리적 결합 즉, 전단결합강도를 높일 수 있는 의미있는 과정임을 확인하였다.

NIRS Analysis of Liquid and Dry Ewe Milk

  • Nunez-Sanchez, Nieves;Varo, Garrido;Serradilla-Manrique, Juan M.;Ares-Cea, Jose L.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1251-1251
    • /
    • 2001
  • The routine analysis of milk chemical components is of major importance both for the management of animals in dairy farms and for quality control in dairy industries. NIRS technology is an analytical technique which greatly simplifies this routine. One of the most critical aspects in NIRS analysis of milk is sample preparation and analysis modes which should be fast and straightforward. An important difficulty when obtaining NIR spectra of milk is the high water content (80 to 90%) of this product, since water absorbs most of the infrared radiation, and, therefore, limits the accuracy of calibrating for other constituents. To avoid this problem, the DESIR system was set up. Other ways of radiation-sample interaction adapted for liquids or semi-liquids exist, which are practically instantaneous and with limited or null necessity of sample preparation: Transmission and Folded Transmission or Transflectance. The objective of the present work is to compare the precision and accuracy of milk calibration equations in two analysis modes: Reflectance (dry milk) and Folded Transmission (liquid milk). A FOSS-NIR Systems 6500 I spectrophotometer (400-2500 nm) provided with a spinning module was used. Two NIR spectroscopic methods for milk analysis were compared: a) folded transmission: liquid milk samples in a 0.1 pathlength sample cell (ref. IH-0345) and b) reflectance: dried milk samples in glass fibre filters placed in a standard ring cell. A set of 101 milk samples was used to develop the calibration equations, for the two NIR analysis modes, to predict casein, protein, fat and dry matter contents, and 48 milk samples to predict Somatic Cell Count (SCC). The calibrations obtained for protein, fat and dry matter have an excellent quantitative prediction power, since they present $r^2$ values higher than 0.9. The $r^2$ values are slightly lower for casein and SCC (0.88 and 0.89 respectively), but they still are sufficiently high. The accuracy of casein, protein and SCC equations is not affected by the analysis modes, since their ETVC values are very similar in reflectance and folded transmission (0.19% vs 0.21%; 0.16% vs 0.19% and 55.57% vs 53.11% respectively), Lower SECV values were obtained for the prediction of fat and dry matter with the folded transmission equations (0.14% and 0.25% respectively) compared to the results with the reflectance ones (0.43% and 0.34% respectively). In terms of accuracy and speed of analytical response, NIRS analysis of liquid milk is recommended (folded transmission), since the drying procedure takes 24 hours. However, both analysis modes offer satisfactory results.

  • PDF

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

적층가공과 절삭가공으로 제작한 의치상과 직접 첨상용 레진 간의 인장결합강도 비교 (Tensile bond strength of chairside reline resin to denture bases fabricated by subtractive and additive manufacturing)

  • 김효성;정지혜;배지명;김정미;김유리
    • 대한치과보철학회지
    • /
    • 제58권3호
    • /
    • pp.177-184
    • /
    • 2020
  • 목적:본 연구의 목적은 절삭가공과 적층가공으로 제작한 의치상과 직접 첨상용 레진과의 인장결합강도를 열중합형 의치상과 직접 첨상용 레진의 인장 결합강도와 비교 및 평가하여 절삭가공과 적층가공으로 제작한 의치상의 직접 첨상을 임상에 활용하고자 하는 것이다. 재료 및 방법:열중합형 의치상 레진(Lucitone 199), 절삭가공용 의치상 레진(VITA VIONIC BASE), 적층가공용 의치상 레진(NextDent Base)을 이용해 가로 25 mm × 세로 25 mm × 높이 3 mm의 직육면체 형태로 제작하였다. 제작한 의치상 레진 시편을 30일간 37℃ 증류수에 보관한 뒤, 건조하여 자가중합형 polyethyl methacrylate (PEMA) 직접 첨상용 레진(REBASE II Normal)을 사용해 결합하였다. 절삭가공과 적층가공용 의치상 레진을 실험군으로, 열중합형 의치상 레진을 대조군으로 설정하고 각 군 당 10개의 시편을 제작하였다. 모든 시편을 24시간 동안 37℃ 증류수에 보관한 뒤 꺼내어 만능시험기를 이용해 10 mm/min의 cross head speed로 인장결합강도를 측정하였고, 파절 양상을 관찰하여 접착 파절, 응집 파절, 혼합 파절로 분류하였다. 의치상의 제작 방법에 따른 직접 첨상용 레진과의 인장결합강도를 일원배치 분산분석으로 분석하였고 사후검정(Bonferroni's method)을 시행하였다 (α= .05). 결과:절삭가공용 의치상 레진과 직접 첨상용 레진과의 인장결합강도(2.33 ± 0.39 MPa)는 열중합형 의치상과 직접 첨상용 레진과의 인장결합강도(2.45 ± 0.39 MPa)와 통계적으로 유의성 있는 차이가 없었다 (P > .999). 적층가공한 의치상 레진과 직접 첨상용 레진과의 인장결합강도(1.23 ± 0.36 MPa)는 나머지 두 군보다 유의성 있게 낮았다 (P < .001). 열중합형과 절삭가공한 의치상에서는 혼합 파절이 가장 많이 나타났으며, 적층가공한 의치상에서는 혼합 파절과 접착 파절이 동일한 빈도로 나타났다. 결론:직접 첨상용 레진과 다양한 방법으로 제작한 의치상의 인장결합강도를 비교하였을 때 적층가공으로 제작한 의치상은 절삭가공으로 제작한 의치상, 열중합형 의치상보다 유의하게 낮은 인장결합강도를 보였다.