• Title/Summary/Keyword: dry-type electrode

Search Result 23, Processing Time 0.027 seconds

Development and Verification of Digital EEG Signal Transmission Protocol (디지털 뇌파 전송 프로토콜 개발 및 검증)

  • Kim, Do-Hoon;Hwang, Kyu-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.7
    • /
    • pp.623-629
    • /
    • 2013
  • This paper presents the implementation result of the EEG(electroencephalogram) signal transmission protocol and its test platform. EEG measured by a dry-type electrode is directly converted into digital signal by ADC(analog-to-digital converter). Thereafter it is transferred DSP(digital signal processor) platform by $I^2C$(inter-integrated circuit) protocol. DSP conducts the pre-processing of EEG and extracts feature vectors of EEG. In this work, we implement the $I^2C$ protocol with 16 channels by using 10 or 12-bit ADC. In the implementation results, the overhead ratio for the 4 bytes data burst transmission measures 2.16 and the total data rates are 345.6 kbps and 414.72 kbps with 10-bit and 12-bit 1 ksps ADC, respectively. Therefore, in order to support a high speed mode of $I^2C$ for 400 kbps, it is required to use 16:1 and $(8:1){\times}2$ ratios for slave:master in 10-bit ADC and 12-bit ADC, respectively.

Design of Dielectric Detector for FRP Hot Stick in EHV Live line Maintenance

  • Chawporn, Talerngkiat;Sriratana, Witsarut;Trisuwannawat, Thanit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2063-2066
    • /
    • 2005
  • This paper presents an approach to detect the dielectric condition of FRP Hot Stick in EHV high voltage cable whereas shutting down the power system is not necessary. The radio frequency generating method is adopted by transmitting radio wave into the Electrodes. This instrument is small, easy to use and also inexpensive. Furthermore, the impurity level of dirt on high voltage insulator (non-ceramic type) will be analyzed by using the methods based on IEEE Std.978-1984 at 105 kV.DC. /305 mm. and OSHA Regulation 1910.269 Part J - live line tools. The frequency at 10-20 MHz is applied to FRP Hot Stick via Electrode1 and from FRP Hot Stick surface to Electrode 2. After that the results will be evaluated by testing in each condition of FRP Hot Stick, such as dry surface, hot surface, foil winding and conductor inserting. Finally, the watt loss will be examined and compared with the loss from humidity and Carbon tracking. The important components of this system are radio frequency generating unit, frequency stabilizing unit, frequency amplifier, FRP Hot Stick frequency counter, processing unit, and display unit.

  • PDF

Etching characteristics of Al-Nd alloy thin films using magnetized inductively coupled plasma

  • Lee, Y.J.;Han, H.R.;Yeom, G.Y.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.56-56
    • /
    • 1999
  • For advanced TFT-LCD manufacturing processes, dry etching of thin-film layers(a-Si, $SiN_x$, SID & gate electrodes, ITO etc.) is increasingly preferred instead of conventional wet etching processes. To dry etch Al gate electrode which is advantageous for reducing propagation delay time of scan signals, high etch rate, slope angle control, and etch uniformity are required. For the Al gate electrode, some metals such as Ti and Nd are added in Al to prevent hillocks during post-annealing processes in addition to gaining low-resistivity($<10u{\Omega}{\cdot}cm$), high performance to heat tolerance and corrosion tolerance of Al thin films. In the case of AI-Nd alloy films, however, low etch rate and poor selectivity over photoresist are remained as a problem. In this study, to enhance the etch rates together with etch uniformity of AI-Nd alloys, magnetized inductively coupled plasma(MICP) have been used instead of conventional ICP and the effects of various magnets and processes conditions have been studied. MICP was consisted of fourteen pairs of permanent magnets arranged along the inside of chamber wall and also a Helmholtz type axial electromagnets was located outside the chamber. Gas combinations of $Cl_2,{\;}BCl_3$, and HBr were used with pressures between 5mTorr and 30mTorr, rf-bias voltages from -50Vto -200V, and inductive powers from 400W to 800W. In the case of $Cl_2/BCl_3$ plasma chemistry, the etch rate of AI-Nd films and etch selectivity over photoresist increased with $BCl_3$ rich etch chemistries for both with and without the magnets. The highest etch rate of $1,000{\AA}/min$, however, could be obtained with the magnets(both the multi-dipole magnets and the electromagnets). Under an optimized electromagnetic strength, etch uniformity of less than 5% also could be obtained under the above conditions.

  • PDF

Wear and Friction Behavior on the Surface of Swash Plate of Compressor for Air Condition System of Automobile (자동차 에어컨용 압축기 사판의 표면 형태에 따른 마찰 마모 거동)

  • Kwon, Yun-Ki;Lee, Geon-Ho;Lee, Ki-Chun
    • Tribology and Lubricants
    • /
    • v.27 no.2
    • /
    • pp.88-94
    • /
    • 2011
  • The tribological characteristics of the swash plate surface of a compressor which is for automobile were investigated. For surface treatments, PTFE and $MoS_2$ are used as a solid lubricant, together with copper alloy. Test condition is set considering actual driving condition. Wear testing is conducted using pin on disk type tester, and the coefficient of friction and the temperature on friction surface are measured. Also, to determine the wear patterns, cross-section of friction surface is analyzed by SEM(scanning electrode microscope). The $MoS_2$, both at dry and lubricated conditions, friction surface and the coefficient of friction maintained rather stable results. But, the PTFE, at oil less condition, sample resulted in rather unstable condition. In case of copper alloy, quite higher friction coefficients(higher than 0.1) were obtained at dry condition. At the temperature of $125^{\circ}C$, seizure has occurred.

Nanometer Scale Vacuum Lithography using Plasma Processes (플라즈마 공정을 이용한 나노미터 단위의 진공리소그래피)

  • Kim, S.O.;Park, B.K.;Park, J.k.;Lee, K.S.;Lee, J.;Yuk, J.H.;Ra, D.K.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1343-1345
    • /
    • 1998
  • This work was carried out to develop a pattern on the nanometer scale using plasma polymerization and plasma etching. This study is also aimed at developing a resist for the nano process and a vacuum lithography process. The thin films of plasma polymerization were fabricated by the plasma polymerization of inter-electrode capacitively coupled gas flow system. After delineating the pattern at accelerating voltage of 30[kV], ranging the dose of $1-500[{\mu}C/cm^2$], the pattern was developed with dry type and formed by plasma etching.

  • PDF

Design and fabrication of film Bulk Acoustic Resonator for flexible Microsystems (Flexible 마이크로시스템을 위한 압전 박막 공진기의 설계 및 제작)

  • 강유리;김용국;김수원;주병권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1224-1231
    • /
    • 2003
  • This paper reports on the air-gap type thin film bulk acoustic wave resonator(FBAR) using ultra thin wafer with thickness of 50$\mu\textrm{m}$. It was fabricated to realize a small size devices and integrated objects using MEMS technology for flexible microsystems. To reduce a error of experiment, MATLAB simulation was executed using material characteristic coefficient. Fabricated thin FBAR consisted of piezoelectric film sandwiched between metal electrodes. Used piezoelectric film was the aluminum nitride(AlN) and electrode was the molybdenum(Mo). Thin wafer was fabricated by wet etching and dry etching, and then handling wafer was used to prevent damage of FBAR. The series resonance frequency and the parallel frequency measured were 2.447㎓ and 2.487㎓, respectively. Active area is 100${\times}$100$\mu\textrm{m}$$^2$.Q-factor was 996.68 and K$^2$$\_$eff/ was 3.91%.

Performance Evaluation of a Plate-Type Membrane Humidifier for PEMFC (고분자전해질연료전지용 판형막가습기 성능 평가)

  • Kho, Back Kyun;Park, JongCheol;Han, In-Su;Shin, Hyun Khil;Hur, Tae Uk;Cho, Sungbaek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.98.2-98.2
    • /
    • 2011
  • For optimal performance of a proton exchange membrane fuel cell (PEMFC), the membrane electrode assembly (MEA) requires hydration, and the membrane's conductivity depends on water content. A humidifier is required to ensure that the reactant gas, usually hydrogen and air, is hydrated before entering the fuel cell. Dry membrane operation or improper hydration causes performance degradation. Typically, the humidification of a fuel cell is carried out by means of an internal or external humidifier. A membrane humidifier is applied to the external humidification of transportation or residential power generation fuel cell due to its convenience and high performance. In this study, The experiments were constructed with a plate-type membrane humidifier in terms of geometric parameters and operating parameters. The results show that the temperature and pressure, the channel length, the membrane thickness and gas flow rate are critical parameters affecting the performance of the humidifier.

  • PDF

Effect of Influent Gas on Mechanical Acceleration Durability Test of PEMFC Polymer Membrane (PEMFC 고분자막의 기계적 가속 내구 평가 과정에서 유입 가스의 영향)

  • Oh, Sohyeong;Hwang, Byungchan;Jung, Sunggi;Jeong, Jihong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.321-326
    • /
    • 2022
  • As the thickness of the polymer membrane of PEMFC(Proton Exchange Membrane Fuel Cells) is getting thinner for PEMFC performance and price reduction, research on improving durability has become more important. In the durability evaluation of membranes, the mechanical durability evaluation time is more than twice that of the chemical durability evaluation time, so it is necessary to select the durability evaluation conditions well. In this study, we tried to check how much the mechanical durability evaluation time changes when there is a difference in the inflow gas type and flow rate in the mechanical durability evaluation protocol (Wet/Dry). When nitrogen was used at a flow rate of 2,000 mL/min, the evaluation time increased by 1.25 times compared to when air was used. An increase in the degradation rate of the electrode Pt was the main factor when air was used. When the flow rate was reduced to 800 mL/min, the air and nitrogen evaluation times increased by 1.5 times and 1.2 times, respectively.

Optimization for Underwater Welding of Marine Steel Plates (선박용 강판의 수중 용접 최적화에 관한 연구)

  • 오세규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.1
    • /
    • pp.49-59
    • /
    • 1984
  • Optimizing investigation of characteristics of underwater welding by a gravity type arc welding process was experimentally carried out by using six types of domestic coated welding electrodes for welding of domestic marine structural steel plates (KR Grade A-1, SWS41A, SWS41B,) in order to develop the underwater welding techniques in practical use. Main results obtained are summarized as follows: 1. The absorption speed of the coating of domestic coated lime titania type welding-electrode became constant at about 60 minutes in water and it was about 0.18%/min during initial 8 minutes of absorption time. 2. Thus, the immediate welding electrode could be used in underwater welding for such a short time in comparison with the joint strength of in-atmosphere-and on-water-welding by dry-, wet-or immediate-welding-electrode. 3. By bead appearance and X-ray inspection, ilmenite, limetitania and high titanium oxide types of electrodes were found better for underwater-welding of 10 mm KR Grade A-1 steel plates, while proper welding angle, current and electrode diameter were 6$0^{\circ}C$, above 160A and 4mm respectively under 28cm/min of welding speed. 4. The weld metal tensile strength or proof stress of underwater-welded-joints has a quadratic relationship with the heat input, and the optimal heat input zone is about 13 to 15KJ/cm for 10mm SWS41A steel plates, resulting from consideration upon both joint efficiency of above-100% and recovery of impact strength and strain. Meanwhile, the optimal heat input zone resulting from tension-tension fatigue limit above the base metal's of SWS41A plates is 16 to 19KJ/cm. Reliability of all the empirical equations reveals 95% confidence level. 6. The microstructure of the underwater welds of SES41A welded in such a zone has no weld defects such as hydrogen brittleness with supreme high hardness, since the HAZ-bond boundary area adjacent to both surface and base metal has only Hv400 max with the microstructure of fine martensite, bainite, pearlite and small amount of ferrite.

  • PDF

High Sensitivity and Selectivity of Array Gas Sensor through Glancing Angle Deposition Method

  • Kim, Gwang Su;Song, Young Geun;Kang, Chong yun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.407-411
    • /
    • 2020
  • In this study, we propose an array-type gas sensor with high selectivity and response using multiple oxide semiconductors. The sensor array was composed of SnO2 and In2O3, and the detection characteristics were improved by using Pt, Au, and Pd catalysts. All samples were deposited directly on the Pt interdigitated electrode (IDE) through the e-beam evaporator glancing angle deposition (GAD) method. They grew in the form of well-aligned nanorods at off-axis angles. The prepared SnO2 and In2O3 nanorod samples were exposed to CH3COCH3, C7H8, and NO2 gases in a 300℃ dry condition. Au-decorated SnO2, Au-decorated In2O3, and Pd-decorated In2O3 exhibited high selectivity for CH3COCH3, C7H8, and NO2, respectively. They demonstrated a high detection limit of the sub ppb level computationally. In addition, measurements from each sensor were executed in the 40% relative humidity condition. Although there was a slight reduction in detection response, high selectivity and distinguishable detection characteristics were confirmed.