• Title/Summary/Keyword: dry mass

Search Result 691, Processing Time 0.028 seconds

Investigation of Hydrodynamic Mass Characteristic for Flow Mixing Header Assembly in SMART (SMART 유동혼합헤더집합체의 동수력 질량 특성 고찰)

  • Lee, Gyu Mahn;Ahn, Kwanghyun;Lee, Kang-Heon;Lee, Jae Seon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.30-36
    • /
    • 2020
  • In SMART, the flow mixing header assembly (FMHA) is used to mix the coolant flowing into the reactor core to maintain a uniform temperature. The FMHA is designed to have enough stiffness so the resonance with reactor internal structures does not occurs during the pipe break and the seismic accidents. Since the gap between the FMHA and the core support barrel assembly is very narrow compared with the diameter of FMHA, the hydrodynamic mass effect acting on the FMHA is not negligible. Therefore the hydrodynamic mass characteristics on the FMHA are investigated to consider the fluid and structure interaction effects. The result of modal analysis for the dry and underwater conditions, the natural frequency of primary vibration mode for the horizontal direction is reduced from 136.67 Hz to 43.76 Hz. Also the result of frequency response spectrum seismic analysis for the dry and underwater conditions, the maximum equivalent stress are increased from 13.89 MPa to 40.23 MPa. Therefore, reactor internal structures located in underwater condition shall consider carefully the hydrodynamic mass effects even though they have sufficient stiffness required for performing its functions under the dry condition.

Effect of Dry Deposition on Water Quality -The comparison of several methodologies for estimating dry deposition flux (수질에 대한 대기건식침적의 영향 - 건식침적량 추정 방법론의 비교를 중심으로)

  • Cheong, Jang-Pyo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.159-168
    • /
    • 2008
  • A special field experiment has been carried out from March 2001 to June 2001 at the Changhowon in Kyunggi to investigate a better methodology for the estimation of dry deposition of pollutions applicable in Korea. In this study, dry deposition plate was used to measure of total and water soluble acidic mass fluxes, and CPRI(Coarse Particle Rotary Impactor), CI(Cascade Impactor) were also used to measure ambient concentrations in various particle size ranges. Sehmel-Hodgson model was used to estimate dry depostion velocity and Weibull probability distribution function was applied to get generalized particle size distribution for the size fractioned concentration data sampled by CPRI and CI. Atmospheric dry deposition fluxes of mass and ionic matters estimated by the various techniques(one-step, multi-step, equi-concentration, subdivision for only the coarse particle range, applying Weibull distribution function, etc.) were compared to flux data sampled by DDP. It was found out that the deposition fluxes estimation methodology calculated by the each particle size range devided by particle size distribution characteristics and the rapidly changed points of deposition velocity using Weibull probability distribution function was the most applicable.

Runoff Characteristics of Refractory Organic Matters from Kyongan River Watershed during Rainfall Event and Dry Season (경안천 유역의 강우 시, 비 강우 시 난분해성 유기물질 유출 특성)

  • Kim, Taewon;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.397-404
    • /
    • 2011
  • This research investigates the runoff characteristics of refractory organic matters from Kyongan river watershed. Samples were taken 27 times during dry season, 4 times during rain events and analyzed into flow rate, Dissolved Organic Carbon (DOC), Particulate Organic Carbon (POC), Refractory Dissolved Organic Carbon (R-DOC), Refractory Particulate Organic Carbon (R-POC). R-DOC during dry season was the lowest in winter and showed a rising tendency in spring and R-POC changes less than R-DOC. The mass loading of Refractory Total Organic Carbon (R-TOC) in summer takes approximately 80% of 1 year mass loading. During rainy season, EMC of R-DOC was similar to R-DOC in dry season. But maximum EMC of R-POC was 12 times higher than that of R-POC in dry season. Results of the survey show that enhanced management of R-DOC in dry season and R-POC in rainy season is needed.

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

Experimental Study for the Identification of the Nascent Product of OH Heterogeneous Reaction with NaCl using Chemical Ionization Mass Spectrometry

  • Park, Jong-Ho;Ivanov, Andrey V.;Molina, Mario J.
    • Mass Spectrometry Letters
    • /
    • v.3 no.4
    • /
    • pp.108-111
    • /
    • 2012
  • An experimental study on the nascent product of the OH heterogeneous reaction with NaCl was performed under dry and wet conditions using a bead-filled flow tube system coupled to a high-pressure chemical ionization mass spectrometer. The ozone concentration in the flow tube for the atomic hydrogen removal was varied in order to control the conversion reaction of molecular chlorine into HCl for the identification of the nascent product. The mass spectrometric observation was that the $O_3$ introduction reduced the concentration HCl, while it increased the concentration of $Cl_2$ and ClO. Based on the experimental results, we suggest that the nascent product of the titled reaction is gaseous $Cl_2$, which is followed by fast conversion into HCl in presence of H. No significant difference in the concentration profile between under dry and wet (RH = 2%) conditions was observed.

Measurement of Atmospheric Dry Deposition and Size Distribution of Particulate PCBs in 1999 at Seoul

  • Park, Seong-Suk;Shin, Hye-Joung;Yi, Seung-Muk;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E1
    • /
    • pp.35-43
    • /
    • 2006
  • Ambient particle size distributions of PCBs and their dry deposition fluxes were measured at a site in Seoul to quantify dry deposition fluxes of PCBs and size characteristics of PCBs in the air, and to estimate ambient concentrations of gaseous PCBs and dry deposition fluxes. The dry deposition plate was used to measure dry deposition fluxes of particulate mass and PCBs and a cascade impactor and rotary impactor were used to measure ambient particle size distributions for small ($D_p<9{\mu}m$) and large ($D_p>9{\mu}m$) particles, respectively. Six sample sets were collected from April to July 1999. The fluxes of particulate total PCBs (the sum of 43 congeners) ranged from 160 to $607ng\;m^{-2}day^{-1}$. The size distribution of total PCBs was bimodal with two peaks in small particle size ($D_p{\sim}0.6\;and\;6{\mu}m$, respectively) and, thus, mass concentration being dominant in small particles. The mean particulate PCBs concentration was $6.9{\mu}g$ PCBs/g. The concentrations of PCB homologues in the gas phase were estimated based on the particle/gas partition coefficient ($K_p$) with the measured values of particulate PCBs in this study and they were comparable to those observed in other previous studies. Dry deposition fluxes were estimated by calculating dry deposition velocities.

Thermal Performance of a Finned-tube Heat Exchanger used in Condensing Gas Boiler

  • Kang, Hie-Chan;Lim, Bok-Bin;Lee, Jung-Man;Kim, Moo-Han
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.61-67
    • /
    • 2009
  • In the present study, an experiment was conducted to investigate the heat and mass transfer performance of heat exchangers used in the condensing gas boiler. Two types of spiral circular fin-tube heat exchangers and a plain tube were tested in the flue gas of propane and dry air. Heat and mass transfer coefficients were measured and compared with the previous correlations. The experimental data for the sensible heat transfer of the plain tube reasonably agreed with the previous correlations for dry air and flue gas. However, the mass transfer coefficient of the plain tube was greater than the previous correlations. The pH, $NO_x$, and $SO_x$ data of condensate were provided.

Nodulation and Fixation in Groundnut by Cowpea Bradyrhizobia (동부류 근류균(根瘤菌)의 땅콩에 대한 근류형성(根瘤形成)과 질소고정(窒素固定))

  • Kim, Moo-Key;Park, Kun-Ho;So, Jae-Don;Choi, Dae-Ung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.25 no.1
    • /
    • pp.89-98
    • /
    • 1992
  • Glasshouse experiments were conducted to evaluate nodulation, and $N_2$ fixation of 73 strains of Bradyrhizobia isolated from nodules of groundnuts and/or cowpeas grown at various location in Korea and 31 strains of cowpea Bradyrhizobia obtained from overseas sources. Of the strains tested 51.9%, 26.4%, and 21.7% were rated fully effective, partially effective, and ineffective, respectively. Eight very effective strains were selected. Nodulation, shoot dry mass, whole plant dry mass, and plant total N content were significantly correlated with each other. The highly significant correlation of total N content and plant dry mass ($r=0.98^{**}$) indicates that plant dry mass can be used as a measure of strain effectiveness in preliminary test.

  • PDF

The effect of dry matter allocation at the early seedling stare on the growth of two grass species (두 초본 종의 생장에 있어서 실생 초기의 물질분해 효과)

  • Park, Young-Mok
    • The Korean Journal of Ecology
    • /
    • v.15 no.3
    • /
    • pp.297-309
    • /
    • 1992
  • The growth of digitaria adscendens and eleusine indica, annual weeds common in japan, was experimentally analyzed under varying untrient conditions. compared with e. indica, d. adscendensshowed a higher the two under high nitrogen availability. Higher net assimilation rate(nar) in d. adscendens than e. india was responsible for high RGR in D. adscendens under the low nitrogen availability. The different of NAR in the two species was induced not by leaf nitrogen content but by nitrogen use efficiency. Under unfertilized conditions nitrogen uptake rate(nur) was greater in d. adscendens than e. indica. Specific absorption rate in two species was similar, but root mass was greater in d. adscendens than e. indica.d. adscendens allocated more dry matter to roots than e. india earlier stage of seedlings. The contributed to higher rot mass and in turn resulted in higher nur in d. adscendens than that in e. india. It is concluuded that the larger allocation of dry matter to roots at early seedling stage in d. adscendens plays an important role in obtaining nitrogen for the continuation of growth under low nitrogen availability.

  • PDF

Morphological and Ginsenoside Differences among North American Ginseng Leaves

  • Proctor, John T.A.;Sullivan, Alan J.;Rupasinghe, Vasantha P.V.;Jackson, Chung-Ja C.
    • Journal of Ginseng Research
    • /
    • v.35 no.2
    • /
    • pp.155-161
    • /
    • 2011
  • Leaf characteristics of mature 2, 3 and 4-year-old North American ginseng (Panax quinquefolius L.) leaves on fruiting and non-fruiting(NF) plants were studied. Leaflets of the 2-year-old plants had the lowest fresh and dry weight, area, volume and internal gas volume. Inflorescence removal in 3-year-old plants did not affect leaf characteristics or ginsenoside concentration but in 4-year-old plants it increased leaf fresh (38.6%) and dry (43.9%) weight, leaf area (29.1%), specific leaf mass (11.4%), leaf volume (43.1%), and leaf thickness (12.1%), and decreased leaf water content (6.2%). Cultivated ginseng, although an understorey plant, had the specific leaf mass, 35.6 g $m^{-2}$ (range, 36 to 39 g $m^{-2}$) and a chlorophyll a/b ratio of 2.40 to 2.61, both suggesting the ability to perform like a sunny habitat plant. Also, specific leaf mass of 35.6 g $m^{-2}$ is similar to that reported for perennial plants, 36.8 g $m^{-2}$, rather than that for annuals, 30.9 g $m^{-2}$.