Behavior of Shear Strength of Coarse Grained Materials Based on Large Scale Direct Shear Test (I) (대형직접전단시험을 이용한 조립재료의 전단거동 특성 (I))

  • Lee Dae-Soo;Kim Kyoung-Yul;Hong Sung-Yun;Jo Hwa-Kyung;Whang Sung-Chun
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.6
    • /
    • pp.81-91
    • /
    • 2005
  • 'Coarse grained material' refers to crushed stones or gravels, and the behaviour of soil containing coarse grained material is not easily defined using the conventional soil mechanics theory due to the influences of large particles, therefore large scale test is essential to investigate their effects. Previous studies have identified the major factors affecting the properties of coarse grained materials by using large scale shear testing apparatus, such as maximum particle size, water content, density and uniformity coefficients. In this paper, the effect of variation of maximum particle size and water content on shear strength was analyzed from the results of large scale shear test. In addition, the fiction coefficient at critical state per vertical load was estimated using the equation proposed by Wood (1998). The sample for the test was obtained from the local quarry sites. Tests results show that the shear strength for 50.8 m maximum particle size is relatively larger than that of 76.3 m and air-dry sample has larger shear strength than saturated sample. In the meantime, the friction coefficient at critical state shows $1.0\sim1.6$ according to the test conditions.

Wear Behavior of Al/SiC Composites Fabricated by Thermal Spray Process (2) - Effect of Applied Load on Wear Behavior - (용사법에 의해 제조된 Al/SiC 복합재료의 마모거동 (2) - 작용하중의 영향 -)

  • Lee, Kwang Jin;Kim, Kyun Tak;Kim, Yeong Sik
    • Tribology and Lubricants
    • /
    • v.29 no.5
    • /
    • pp.298-303
    • /
    • 2013
  • In this work, the effect of applied load on the wear behavior of Al/SiC composites was studied. Al/SiC composites were fabricated following the thermal spray process. Dry sliding wear tests were performed on these composites under four different applied loads, i.e., 5, 10, 15, and 20 N. The wear behaviors of the composites under these applied loads were investigated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). Under applied loads of up to 15 N, the wear rates of Al/SiC composites decreased with an increase in the applied load because of the formation of an adhesion layer on the worn surface. However in the case of an applied load of 20 N, the wear rate was significantly high because the formation and fracture of the adhesion layer were repeated continuously. These results show that the wear behaviors of the tested composites are significantly influenced owing to the applied loads.

Characteristics of Shear Strength of Coarse Grained Materials Depending on Experimental Densities (시험밀도에 따른 조립재료의 전단강도 특성)

  • Kim, Kyoung-Yul;Lee, Dae-Soo;Hong, Sung-Yun;Oh, Ki-Dae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.854-859
    • /
    • 2006
  • The density of coarse grained materials which is used in rock-fill dam or the piling the ground are used as $1.85\sim2.10g/cm^3$. Hereupon, the effect of variation of density on shear strength of ones was analyzed from the results of large scale shear test. The sample for the test was obtained from the local quarry sites. The test conditions are that density(1.85 versus $2.10g/cm^3$), material size range$(76.3\sim2.0\;mm)$, water content(air dry condition) and uniformity coefficient(5.0) Test result shows that the shear strength of $2.10g/cm^3$ is relatively larger than that of $1.85g/cm^3$.

  • PDF

Experimental Study of Air Side Pressure Drop and Heat Transfer Characteristics of Enhanced Fin-Tube Heat Exchangers (열전달 촉진 핀-관 열교환기의 공기측 압력강화 및 열전달 특성에 관한 실험)

  • Youn, Baek;Kil, Yong Hyun;Park, Hyun Yeon;Kim, Young Saeng
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1555-1563
    • /
    • 1998
  • Heat transfer and pressure drop for ${\phi}10.07$ dry surface fin-tube heat exchanger with wave and wave-slit fins were measured for different fin spacings and number of tube rows. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively, and wave depth of wave fin is 1.5mm. The experiments were performed for 4 different fin spacings, 1.3, 1.5, 1.7 and 2.0mm, and the number of tube rows were 1,2 and 3 rows. The present results were compared with the previous results for the wave depth of 2mm. Also hydrophilic coated and bare fins were tested. Correlations for Colburn j-factor and friction factor were developed.

Effect of Plasma Modification of Woven type Carbon Fibers on the Wear Behavior of Carbon Fiber/Epoxy Composites (평직 탄소섬유의 플라즈마 처리 및 이에 따른 탄소섬유/에폭시 복합재의 마모 특성)

  • Lee, Jae-Seok;Rhee, Kyong-Yop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.12
    • /
    • pp.113-118
    • /
    • 2010
  • For a present study, woven type carbon fibers were surface-modified by oxygen plasma to improve adhesive strength between carbon fibers and epoxy. The change of hydrophilic properties by the plasma modification was investigated through the contact angle measurement and the calculation of surface energy of carbon fiber due to the oxygen plasma modification. FESEM and XPS analyses were performed to study the chemical and physical changes on the surface of carbon fibers due to the oxygen plasma modification. Pin-on-disk wear tests were conducted under dry condition using unmodified and plasma-modified carbon/epoxy composites to investigate the effect of plasma modification on the wear behavior of woven type carbon/epoxy composites. The results showed that the friction coefficient and the wear rate of plasma-modified carbon/epoxy composites were lower than those of unmodified carbon/epoxy composites, respectively. XPS analysis showed that new functional group of a carbonyl type was created on the carbon fibers by the $O_2$ plasma treatment, which enhanced adhesive strength between carbon fibers and epoxy, leading to improve wear properties

Experimental study of air side pressure drop and heat transfer characteristics of wave and wave-slit fin-tube heat exchangers (웨이브 및 웨이브-슬릿 열전달촉진 휜-관 열교환기의 공기측 압력강하 및 열전달 특성에 관한 실험)

  • Yoon, Baek;Gil, Yong-Hyun;Park, Hyun-Yeon;Yoo, Guk-Chul;Kim, Young-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.589-599
    • /
    • 1998
  • Air side heat transfer and pressure drop for fin-tube heat exchanger with wave and wave-slit fins were measured for various fin spacings and number of tube rows. Outer diameter of the tube including fin collar is 10.07mm, and experiments were done with dry surface condition. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively, and wave depth of the wave fin is 2mm. Experiments were conducted for 1, 2 and 3 rows and 3 different fin spacings, 1.3, 1.5 and 1.7mm. An attempt was made to demonstrate advantage of the enhanced fins over the plane fin by introducing the concept of fan power, Effect of the number of tube rows on heat transfer was discussed in connection with general mechanisms of heat transfer enhancement for fin-tube heat exchanger. Also the effect of hydrophilic coating was investigated. Lastly, correlations for Colburn j-factor and friction factor were developed.

  • PDF

Changes of Flame Retardant and Physical Properties of Cotton Knitted Fabrics after Flame Resistant Treatment (면편성물의 방염처리에 의한 방염성과 물성변화)

  • Jee, Ju-Won;Song, Kyung-Geun
    • Fashion & Textile Research Journal
    • /
    • v.5 no.3
    • /
    • pp.273-282
    • /
    • 2003
  • Effect of fixation methods and relaxation treatment on the flame retardant(FR) and physical properties of MDPP/HMM treated cotton weft-knitted fabrics were studied. Combination of four different fixation methods - relaxation, swelling agent treatment, pad dry cure fixation, and wet fixation - were applied to flame retardant finish of cotton weft-knitted fabric with MDPP/HMM. As the results, 1. Swelling agent and wet fixation method helps FR agent penetrate the fiber efficiently. Interlock showed relatively higher values of LOI than single jersey. 2. Interlock showed relatively higher values of bending rigidity(B), shear rigidity(G) and coefficient of friction(MIU) than those of single jersey before and after flame resistant treatment. 3. An increase in internal volume of cotton fiber by relaxation treatment increased the bending rigidity(B), shear rigidity(G) and compressional energy(WC). 4. The cotton weft-knitted fabric treated wet fixation, which crossliked FR agent efficiently, showed higher bending rigidity, shear rigidity(G) and lower compressional energy(WC). Retention of swelling ability of cotton weft-knitted fabrics treated with MDPP/HMM, which increased the internal volume of cotton weft-knitted fabric, showed lower bending rigidity.

The Characteristics of Wear Resistance of Cu-TiB2 Composites Reinforced by TiB2 Powders (TiB2 분말로 강화된 Cu-TiB2 복합재료의 내마모특성)

  • Lee Tae-Woo;Choi Jong-Un;Kang Kae-Myung
    • Korean Journal of Materials Research
    • /
    • v.15 no.12
    • /
    • pp.824-828
    • /
    • 2005
  • In this study the effect of the content of $TiB_2$ on wear properties was investigated. $Cu-TiB_2$ composites have been fabricated by hot extrusion. Sliding wear tests were peformed by a pin-on-disk type wear test machine under dry condition and loads varied with from 20N to 80N at sliding speed 3.5Hz. The test results showed that the wear losses and the friction coefficients decreased with increasing $Cu-TiB_2$ volume fraction and increasing the size of $Cu-TiB_2$ particle. Wear property of $10{\mu}m,\;5 vol\%\; TiB_2$ specimen was excellent all of the wear specimens. It is thought that the increase of plastic flow resistivity due to uniform distribution of $10{\mu}m,\;5 vol\%\; TiB_2$ wear specimen would improve wear property. The worn surface and wear debris were examined by optical microscope and scanning electron microscope.

Wear Behavior of Al/SiC Composites Fabricated by Thermal Spray Process (1) - Effect of Sliding Speed on Wear Behavior - (용사법에 의해 제조된 Al/SiC 복합재료의 마모거동 (1) - 미끄럼 속도의 영향 -)

  • Lee, Kwang-Jin;Kim, Kyun-Tak;Kim, Yeong-Sik
    • Tribology and Lubricants
    • /
    • v.27 no.6
    • /
    • pp.351-355
    • /
    • 2011
  • Al/SiC composites were fabricated by thermal spray process, and the dry sliding wear tests were performed using the various sliding speed of 10, 30, 60 and 90 RPM through 1000 cycles. The applied load was 10 N and radius of wear track was 15 mm. Wear tracks on the Al/SiC composites were investigated using scanning electron microscope(SEM) and energy dispersive X-ray spectroscopy (EDS). In the case of sliding speed of 10 RPM, adhesive wear behavior caused by plastic deformation of composits surface was observed. In the cases of sliding speed of 30, 60, 90 RPM, abrasive wear behavior on the adhered layer formed by debris were observed. Through this study, it was found that the wear behavior of Al/SiC composites was mainly influenced by the sliding speed.

Characteristics of TiAlCrSiN coating to improve mold life for high temperature liquid molding (고온 액상 성형용 금형 수명 향상을 위한 TiAlCrSiN 코팅의 특성)

  • Yeo, Ki-Ho;Park, Eun-Soo;Lee, Han-Chan
    • Journal of Surface Science and Engineering
    • /
    • v.54 no.5
    • /
    • pp.285-293
    • /
    • 2021
  • High-entropy TiAlCrSiN nano-composite coating was designed to improve mold life for high temperature liquid molding. Alloy design, powder fabrication and single alloying target fabrication for the high-entropy nano-composite coating were carried out. Using the single alloying target, an arc ion plating method was applied to prepare a TiAlCrSiN nano-composite coating had a 30 nm TiAlCrSiN layers are deposited layer by layer, and form about 4 ㎛-thickness of multi-layered coating. TiAlCrSiN nano-composite coating had a high hardness of about 39.9 GPa and a low coefficient of friction of less than about 0.47 in a dry environment. In addition, there was no change in the structure of the coating after the dissolution loss test in the molten metal at a temperature of about 1100 degrees.