• Title/Summary/Keyword: drum filter rpm

Search Result 5, Processing Time 0.022 seconds

The development of algae removal system to minimize the damage of algae bloom on freshwater (담수조류의 대량번식에 따른 피해를 최소화하기 위한 녹조제거기 개발)

  • Han J.H.;Park W.S.;Kim J.H.;Lee Y.S.;Rho J.H.;Kim Y.K.;Yoon B.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.1
    • /
    • pp.62-69
    • /
    • 2000
  • The study was performed to apply the algae removal system to coagulation-filtration process for minimize the damage to screen interruption of water treatment plants and died of fish by algae bloom on freshwater. Sample used Nokdong river water and Alkalinity, turbidity, chlorophyll-a and pH measured using Jar test and drum filter for coagulation-filtration process to determine optimum coagulation condition. A jar test apparatus and laboratory reactor were used in this study. The highest removal efficiency was observed when condition of flocculation time, coagulant dosage, drum filter rpm and chlorophyll-a concentration were to be 5min, 5mg/ℓ, 3rpm and 90㎍/ℓ, respectively. The average removal efficiencies measured of chlorophyll-a and turbidity using Alum were 50~60% and 30~50%, respectively. PAC was more effective than Alum in removal chlorophyll-a about 20%.

  • PDF

Development of Automatic Backwashing Treatment System for Ballast Water (자동역세척 여과장치를 이용한 선박 밸러스트수 처리)

  • Park Sang-Ho;Lim Jae-Dong;Kim In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.181-185
    • /
    • 2005
  • The treated ballast water from previous treatment contains microorganisms and pathogenic organisms in an filtration treatment system. The advantage of this process can be filtrated to minimize the demage to screen clogging of drum filter with sweeping the solids off rotating the surface of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. Also the fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage, too. Filter rotation speed at 20rpmis 40.5cmHg and 40rpm is 36.6cmHg. Filter out impurities from ballast water over 60rpm is 35cmHg. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the removal of ballast water.

  • PDF

A study of Ballast water Treatment using a Disk filter (디스크 여과장치를 이용한 선박 밸러스트수 전처리 연구)

  • Park, Sang-Ho;Lim, Jae-Dong;Park, Sun-Jung;Kim, Dong-Geun;Kim, In-Soo
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.149-150
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included in number of ballast that is happened in ship using automatic back washing filter. Reason that remove first contaminant that is included in number of ballast is that heighten processing effect of after processing process. of the filter. Another advantage is to drop oft the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed at 1.0rpm is filter resistance 3.0bar and 3.0rpm is filter resistance 2.8bar. Filter out impurities from ballast water over 6.0rpm is filter resistance 2.6bar and 10rpm is filter resistance 2.5bar. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF

Sea water Treatment using an Automatic Backwashing Filter (자동역세척 여과장치를 이용한 해수처리)

  • Park Sang-Ho;Lim Jae-Dong;Kim In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.30 no.3 s.109
    • /
    • pp.241-245
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included a number of ballast that is happened in ship using automatic back washing filter. Reason that removes first contaminant that is included in number of ballast is that heighten processing effectof after processing processof the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed of filtration filter could be expose by 35mmHg more than 60 rpm and filter consecutively filtration pressure is 40.5mmHg in 20 rpm and 40 rpm are 36.6mmHg. Filtration system removal aquatic organism over $70{\mu}min$ ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

Ballast water Treatment using a Multistage Filter (다단 디스크 여과장치를 이용한 선박 밸러스트수 처리)

  • Park, Sang-Ho;Lim, Jae-Dong;Kim, In-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.79-83
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included in number of ballast that is happened in ship using automatic bade washing filter. Reason that remove first contaminant that is included in number of ballast is that heighten processing effect of after processing process. of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed at 1.0rpm is filter resistance 3.0bar and 3.0rpm is filter resistance 2.8bar. Filter out impurities from ballast water over 6.0rpm is filter resistance 26bar and 10rpm is filter resistance 2.5bar. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF