• Title/Summary/Keyword: drug use evaluation

Search Result 259, Processing Time 0.026 seconds

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF

Comparative analysis of Glomerular Filtration Rate measurement and estimated glomerular filtration rate using 99mTc-DTPA in kidney transplant donors. (신장이식 공여자에서 99mTc-DTPA를 이용한 Glomerular Filtration Rate 측정과 추정사구체여과율의 비교분석)

  • Cheon, Jun Hong;Yoo, Nam Ho;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.35-40
    • /
    • 2021
  • Purpose Glomerular filtration rate(GFR) is an important indicator for the diagnosis, treatment, and follow-up of kidney disease and is also used by healthy individuals for drug use and evaluating kidney function in donors. The gold standard method of the GFR test is to measure by continuously injecting the inulin which is extrinsic marker, but it takes a long time and the test method is complicated. so, the method of measuring the serum concentration of creatinine is used. Estimated glomerular filtration rate (eGFR) is used instead. However, creatinine is known to be affected by age, gender, muscle mass, etc. eGFR formulas that are currently used include the Cockroft-Gault formula, the modification of diet in renal disease (MDRD) formula, and the chronic kidney disease epidemilogy collaboration (CKD-EPI) formula for adults. For children, the Schwartz formula is used. Measurement of GFR using 51Cr-EDTA (diethylenetriamine tetraacetic acid), 99mTc-DTPA (diethylenetriamine pentaacetic acid) can replace inulin and is currently in use. Therefore, We compared the GFR measured using 99mTc-DTPA with the eGFR using CKD-EPI formula. Materials and Methods For 200 kidney transplant donors who visited Asan medical center.(96 males, 104 females, 47.3 years ± 12.7 years old) GFR was measured using plasma(Two-plasma-sample-method, TPSM) obtained by intravenous administration of 99mTc-DTPA(0.5mCi, 18.5 MBq). eGFR was derived using CKD-EPI formula based on serum creatinine concentration. Results GFR average measured using 99mTc-DTPA for 200 kidney transplant donors is 97.27±19.46(ml/min/1.73m2), and the eGFR average value using the CKD-EPI formula is 96.84±17.74(ml/min/1.73m2), The concentration of serum creatinine is 0.84±0.39(mg/dL). Regression formula of 99mTc-DTPA GFR for serum creatinine-based eGFR was Y = 0.5073X + 48.186, and the correlation coefficient was 0.698 (P<0.01). Difference (%) was 1.52±18.28. Conclusion The correlation coefficient between the 99mTc-DTPA and the eGFR derived on serum creatinine concentration was confirmed to be moderate. This is estimated that eGFR is affected by external factors such as age, gender, and muscle mass and use of formulas made for kidney disease patients. By using 99mTc-DTPA, we can provide reliable GFR results, which is used for diagnosis, treatment and observation of kidney disease, and kidney evaluation of kidney transplant patients.

AN OBSERVATIONAL MULTI-CENTER STUDY FOR EVALUATION OF EFFICACY, SAFETY AND PARENTAL SATISFACTION OF METHYLPHENIDATE-OROS IN CHILDREN WITH ADHD (주의력결핍과잉운동장애 아동에게 Methylphenidate-OROS 투여시 효용성과 안전성 및 부모 만족도를 평가하기 위한 다기관관찰연구)

  • Kim, Bong-Seog;Park, Eun-Jin
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.16 no.2
    • /
    • pp.279-285
    • /
    • 2005
  • Objectives : This study was performed to evaluate the efficacy and safety of MPH-OROS and parental satisfaction for treatment of children with ADHD Method : The 569 participants were clinically diagnosed for ADHD using DSM-IV criteria. We switched current medication to MPH-OROS or introduced MPH-OROS for treatment of ADHD. We assessed the clinical global impression severity of illness (CGI-S), the clinical global impression severity of improvement(CGI-I). And the parents of participants measured the Korean version of Conners rating scale at baseline, the 1 st week and the 3rd week after MPH-OROS trial. At the 3rd week, the parents measured the parent satisfaction questionnaire. Results : $13\%$ of participants dropped out because of several causes including side effects. The change of CGI-S was significantly decreased. Using CGI-I, the improvement was $72.3\%$ at the 1st week and $87.4\%$ at the 3rd week. The total score of the Korean version of Conners parent rating scale was significantly decreased. The participants complaining one or more of side effects were 119$(20.7\%)$, and the most common side effect was anorexia. The $94\%$ of parents replied that they were overall satisfied with MPH-OROS trial. Also the advantages of MPH-OROS of parental report were the long duration of the drug, the improvement of schoolwork and attitude, the improvement of home behavior and homework and the improvement of overactivity. Conclusion : MPH-OROS is effective and well-tolerated in actual clinical use for ADHD.

  • PDF

Reproducibility of the Assessment of Myocardial Function Using Gated Tc-99m-MIBI SPECT and Quantitative Software (게이트 Tc-99m-MIBI SPECT와 Cedars 소프트웨어를 이용한 심근 기능 측정의 재현성)

  • Lee, Dong-Soo;Cheon, Gi-Jeong;Ahn, Ji-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.403-413
    • /
    • 1998
  • Purpose: We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. Materials and Methods: We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Results: Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/- 42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml +/- 39 ml), and EF from 20% to 65% (51% +/- 14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. Conclusion: We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m-MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect.

  • PDF

The Comparison and Distribution of Temperatures Established in Display Stands and Food Surfaces for Cold and Frozen Foods in large Discount Stores in Korea (대형할인매장에서의 냉장.냉동식품 판매대의 설정온도와 판매식품 표면온도 비교 및 온도분포 분석)

  • Choi, Moon-Sil;Choi, Jeong-Ae;Kim, Mee-Hye;Bahk, Gyung-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.308-314
    • /
    • 2011
  • This study surveyed and compared the temperatures established in display stands and food surfaces for cold and frozen foods in large discount stores in Korea. The temperatures established in display stands for cold food ranged with $3.5{\pm}1.8^{\circ}C$ as mean, minimum and maximum were $0^{\circ}C$ and $7^{\circ}C$. However, the surface temperatures of cold food on sale ranged with $10.7{\pm}2.9^{\circ}C$ as a mean, minimum $4.6^{\circ}C$ and maximum $18.4^{\circ}C$. Totally, the surface temperature of cold food on sale was $7.2^{\circ}C$, as a mean, higher than established in display stands for cold food in large discount stores in Korea. 53% of the surveyed cold foods were more than $10^{\circ}C$ in surface temperature and only 47% was less than $10^{\circ}C$. The differences between temperatures were lowest in fruits, salads and vegetables, but highest in milk products. On the other hand, the temperatures established in display stands for frozen food showed a range with $-20.7{\pm}1^{\circ}C$ as a mean. However, the surface temperatures of frozen food on sale showed a range with $-15.4{\pm}5^{\circ}C$ as a mean, minimum $-28^{\circ}C$ and maximum $-4.6^{\circ}C$ (included defrosting). The surface temperatures of frozen food, frozen meats, frozen processed foods and ice creams were $-13.8^{\circ}C$, $-15.9^{\circ}C$, and $-16.8^{\circ}C$, respectively. Only 32.3% of surveyed frozen foods showed less than $-18^{\circ}C$ in surface temperature. In conclusion, the temperatures established on cold and frozen food display stands were less than those of cold and frozen food surfaces on sale. There was also much variation in food surface temperatures during cold and frozen food storage and sales. Therefore, a temperature management system technology use at the distribution level for cold and frozen foods will be developed.

Residual Characteristics of Bistrifluron and Chlorantraniliprole in Strawberry (Fragaria ananassa Duch.) for Establishing Pre-Harvest Residue Limit (생산단계 잔류허용기준 설정을 위한 딸기 중 bistrifluron과 chlorantraniliprole의 잔류 특성 연구)

  • Lee, Jae Won;Kim, Ji Yoon;Kim, Hee gon;Hur, Kyung Jin;Kwon, Chan Hyeok;Hur, Jang Hyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • BACKGROUND: Pesticide residue analysis is essentially required for safety evaluation of agricultural products. Bistrifluron and chlorantraniliprole have been currently considered as potentials to deeply evaluate their residues in agricultural products because they are frequently found in strawberry. This work was performed to investigate the residual patterns of bistrifluron and chlorantraniliprole in strawberry after harvest. METHODS AND RESULTS: Strawberry was treated with bistrifluron and chlorantraniliprole 0, 1, 2, 3, 5, 7 and 10 days before harvest under greenhouse conditions. The strawberry samples were subjected to solvent and solid phase extractions followed by LC-MS/MS analysis. There covery percentages of bistrifluron and chlorantraniliprole for tified in the control samples ranged from approximately 82 to 103% with the method limit of 0.005 mg/kg. The concentrations of bistrifluron and chlorantraniliprole in strawberry samples decreased significantly in 10 days after treatment, giving the safety levels of 0.04 to 0.06 mg/kg at 10 days after application, as considered maximum residue limit. The half-lives of bistrifluron and chlorantraniliprole based on first order kinetics were determined to 6.3 days and 6.4 days, respectively. CONCLUSION: Bistrifluron and chlorantraniliprole are suggested to use in strawberry 10 days before harvest to reach residual safety levels.

Quality Characteristics of Jocheong Containing Various Level of Letinus edodes Extracts (표고버섯 추출액을 이용한 조청의 품질특성)

  • Park, Jung-Suk;Na, Hwan-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.7
    • /
    • pp.1082-1090
    • /
    • 2005
  • Jocheong was prepared by adding Lentinus edodes extract to improve its quality and to give some functional properties. Contents of crude protein, ash and crude lipid were similar to those of control, while carbohydrate content was decreased. Total mineral content were $1,916.03\~2,674.24mg/kg$ that was no difference between test samples. From HPLC determination of free sugars, Jocheong was found to contain maltose as the highest sugar, followed by glucose and fructose. In amino acid analysis, seventeen amino acid were identified and quantified. Glutamic acid in Jocheong was major amino acid. The major fatty acids in Jocheong $(0\%,\;control)$ were linoleic acid, palmitic acid, oleic acid, myristic acid and caproic acid. There was no significant differences in fatty acid composition, pH and reducing sugar content among the Jocheong samples. The viscosity and solid contents tended to decrease with the addition of Lentinus edodes extract. Increasing the ratio of mushroom extract in Jocheong tended to decrease the lightness, yellowness and redness in Hunter's color value. Although sensory value decreased with increasing Lentinus edodes extracts, use of mushroom extracts (7: 3; saccharification liquids: Lentinus edodes extracts) is recommended for making Jocheong.

Quantitative Assessment of Coronary Artery Diameter in Patients with Atrial Fibrillation and Normal Sinus Rhythm (심방세동 환자와 정상 심전도 환자의 관상동맥 직경 정량적 평가)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.567-574
    • /
    • 2022
  • Coronary artery disease (CAD) and atrial fibrillation (AF) are known to share many risk factors. In particular, in the case of acute coronary syndrome, it may be difficult to clearly determine the diameter of the vessel due to complete occlusion of the vessel and thrombus. Thus, the relationship between the diameter of the coronary arteries was evaluated to be used as a reference data before the treatment of coronary arteries and drug selection in patients with AF. From January 2020 to August 2022, images of coronary angiography (CAG) with AF and normal sinus rhythm (NSR) on electrocardiography were target. In both subjects, images of normal coronary artery without lesions as a result of CAG were used. For all vessels, the diameters of the vessels were measured by dividing them into proximal, middle, and distal parts, and the measured diameters were divided by the average for evaluation. As a result of analyzing the left anterior descending artery diameter, the vessel diameter of the AF patient was 2.24±0.26 mm, which was smaller than that of the NSR patient, 2.86±0.38 mm, and was statistically significant. (p<0.001) As a result of analyzing the left circumflex artery diameter, the vessel diameter of the AF patient was 2.34±0.28 mm, which was smaller than the vessel diameter of the NSR patient, 2.87±0.29 mm, and was statistically significant. (p<0.001) As a result of analyzing the diameter of the right coronary artery, the vessel diameter of the AF patient was 2.68±0.5 mm, which was smaller than the vessel diameter of the NSR patient, 3.35±0.4 mm, and was statistically significant. (p<0.001) Considering that the coronary artery size of AF patients is significantly smaller than the coronary vessel size of NSR patients, it is considered as a useful study to be used as a reference for evaluating coronary artery diameter when the arrhythmia is AF. In particular, it is considered to be a study that can be helpful in diagnosing lesions, using drugs before and after surgery, and choosing to use auxiliary devices such as intravascular ultrasound.

Evaluation of Microbial Contamination in the Manufacturing Process of Non-Heated Frozen Rice Cakes (비가열 냉동떡의 제조공정에 대한 미생물 오염도 평가)

  • Yong-Sik, Yoon;Eun-In, Yang;Young-Soo, Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.6
    • /
    • pp.400-410
    • /
    • 2022
  • This study was performed to analyze the microbial contamination levels of three non-heated rice cake manufacturers in terms of seasonal manufacturing process and to investigate the effects of summertime soaking on contamination levels and temperature-controlled soaking in water on reduction in microbial levels. The total aerobic bacteria (TAB) ranged from 2.69 log CFU/g to 5.08 log CFU/g in the produce, but the microbial contamination increased sharply during soaking. The levels of TAB and coliforms during summer soaking were 7.01 and 3.96 log CFU/g, respectively, and this was significantly higher than those in other seasons. The contamination level was high in the subsequent freezing, with the TAB level (6.24 log CFU/g) exceeding the legal standard. The temperature of soaking water in summer increased from 19.1℃ to 26.8℃ after 12 h of soaking. The microbial contamination was significantly high commensurate with increased soaking time, and the TAB level in the frozen process exceeded the legal standard from 9 h of soaking. The use of ice packs to prevent the increase in temperature of the soaking water in summer resulted in maintenance of temperature at 20.1℃ for up to 12 h. The average TAB value in the freezing process was 4.42 log CFU/g after 12 h of soaking, and this is 1.77 log CFU/g lower than that before. Based on these results, it was determined that controlling the soaking time and water temperature are essential for the production of a safe unheated frozen rice cake. The safety of the HACCP system could be established by applying these preventive management standards.