• Title/Summary/Keyword: drug residues

Search Result 346, Processing Time 0.027 seconds

Development of an Official Analytical Method for Determination of Aclonifen in Agricultural Products Using GC-ECD (GC-ECD를 이용한 농산물 중 제초제 aclonifen의 공정분석법 확립)

  • Ko, Ah-Young;Kim, Hee-Jung;Jang, Jin;Lee, Eun-Hyang;Joo, Yoon-Ji;Kwon, Chan-Hyeok;Son, Young-Wook;Chang, Moon-Ik;Rhee, Gyu-Seek
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.388-394
    • /
    • 2014
  • BACKGROUND: Aclonifen is used as a systemic and selective herbicide to control a wide spectrum broad-leaf weeds by inhibition carotenoid biosynthesis, and then its MRLs(Maximum Residue Limits) will be determined in onion and garlic. In this study, a new official method was developed for aclonifen determination in agricultural products to routinely inspect the violation of MRL as well as to evaluate the terminal residue level. METHODS AND RESULTS: Aclonifen was extracted from crop samples with acetone and the extract was partitioned with dichloromethane and then purified by silica solid phase extraction(SPE) cartridge. The purified samples were detected GC using an ECD detector. Limits of detection(LOD) was 0.001 mg/kg and quantification(LOQ) was 0.005 mg/kg, respectively. For validation purposes, recovery studies were carried out at three different concentration levels (LOQ, $10{\times}LOQ$, $50{\times}LOQ$, n=5). The recoveries were ranged from 74.3 to 95.0% with relative standard deviations(RSDs) of less than 8%. All values were consistent with the criteria ranges requested in the Codex guidelines(CAC/GL 40). CONCLUSION: The proposed analytical method was accurate, effective and sensitive for aclonifen determination and it will be used to as an official method in Korea.

Selection and Validation of an Analytical Method for Trifludimoxazin in Agricultural Products with LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Trifludimoxazin의 시험법 선정 및 검증)

  • Sun Young Gu;Su Jung Lee;So eun Lee;Chae Young Park;Jung Mi Lee;Inju Park;Yun Mi Chung;Gui Hyun Jang;Guiim Moon
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.3
    • /
    • pp.79-88
    • /
    • 2023
  • Trifludimoxazin is a triazinone herbicide that inhibits the synthesis of protoporphyrinogen oxidase (PPO). The lack of PPO damages the cell membranes, leading to plant cell death. An official analytical method for the safety management of trifludimoxazin is necessary because it is a newly registered herbicide in Korea. Therefore, this study aimed to develop a residual analysis method to detect trifludimoxazin in five representative agricultural products. The EN method was established as the final extraction method by comparing the recovery test and matrix effect with those of the QuEChERS method. Various sorbent agents were used to establish the clean-up method, and no differences were observed among them. MgSO4 and PSA were selected as the final clean-up conditions. We used LC-MS/MS considering the selectivity and sensitivity of the target pesticide and analyzed the samples in the MRM mode. The recovery test results using the established analysis method and inter-laboratory validation showed a valid range of 73.5-100.7%, with a relative standard deviation and coefficient of variation less than 12.6% and 14.5%, respectively. Therefore, the presence of trifludimoxazin can be analyzed using a modified QuEChERS method, which is widely available in Korea to ensure the safety of residual insecticides.

Development and Validation of an Analytical Method for Fungicide Fluoxastrobin Determination in Agricultural Products (농산물 중 살균제 Fluoxastrobin의 시험법 개발 및 유효성 검증)

  • So Eun, Lee;Su Jung, Lee;Sun Young, Gu;Chae Young, Park;Hye-Sun, Shin;Sung Eun, Kang;Jung Mi, Lee;Yun Mi, Chung;Gui Hyun, Jang;Guiim, Moon
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.6
    • /
    • pp.373-384
    • /
    • 2022
  • Fluoxastrobin a fungicide developed from Strobilurus species mushroom extracts, can be used as an effective pesticide to control fungal diseases. In this study, we optimized the extraction and purification of fluoxastrobin according to its physical and chemical properties using the QuEChERS method and developed an LC-MS/MS-based analysis method. For extraction, we used acetonitrile as the extraction solvent, along with MgSO4 and PSA. The limit of quantitation of fluoxastrobin was 0.01 mg/kg. We used 0.01, 0.1, and 0.5 mg/kg of five representative agricultural products and treated them with fluoxastrobin. The coefficients of determination (R2) of fluoxastrobin and fluoxastrobin Z isomer were > 0.998. The average recovery rates of fluoxastrobin (n=5) and fluoxastrobin Z isomer were 75.5-100.3% and 75.0-103.9%, respectively. The relative standard deviations (RSDs) were < 5.5% and < 4.3% for fluoxastrobin and fluoxastrobin Z isomer, respectively. We also performed an interlaboratory validation at Gwangju Regional Food and Drug Administration and compared the recovery rates and RSDs obtained for fluoxastrobin and fluoxastrobin Z isomer at the external lab with our results to validate our analysis method. In the external lab, the average recovery rates and RSDs of fluoxastrobin and fluoxastrobin Z isomer at each concentration were 79.5-100.5% and 78.8-104.7% and < 18.1% and < 10.2%, respectively. In all treatment groups, the concentrations were less than those described by the 'Codex Alimentarius Commission' and the 'Standard procedure for preparing test methods for food, etc.'. Therefore, fluoxastrobin is safe for use as a pesticide.

Determination and Validation of an Analytical Method for Spiropidion and Its Metabolite Spiropidion-enol (SYN547305) in Agricultural Products with LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Spiropidion 및 대사산물 Spiropidion-enol (SYN547305) 시험법 개발 및 검증)

  • Gu, Sun Young;Lee, Su Jung;Shin, Hye-Sun;Kang, Sung Eun;Chung, Yun Mi;Lee, Jung Mi;Jung, Yong-hyun;Moon, Guiim
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.2
    • /
    • pp.82-94
    • /
    • 2022
  • BACKGROUND: Spiropidion and its metabolite are tetramic acid insecticide and require the establishment of an official analysis method for the safety management because they are newly registered in Korea. Therefore, this study was to determine the analysis method of residual spiropidion and its metabolite for the five representative agricultural products. METHODS AND RESULTS: Three QuEChERS methods (original, AOAC, and EN method) were applied to optimize the extraction method, and the EN method was finally selected by comparing the recovery test and matrix effect results. Various adsorbent agents were applied to establish the clean up method. As a result, the recovery of spiropidion was reduced when using the dispersive-SPE method with MgSO4, primary secondary amine (PSA), graphitized carbon black (GCB) and octadecyl (C18) in soybean. Color interference was minimized by selecting the case including GCB and C18 in addition to MgSO4. This method was established as the final analysis method. LC-MS/MS was used for the analysis by considering the selectivity and sensitivity of the target pesticide and the analysis was performed in MRM mode. The results of the recovery test using the established analysis method and inter laboratory validation showed a valid range of 79.4-108.4%, with relative standard deviation and coefficient of variation were less than 7.2% and 14.4%, respectively. CONCLUSION(S): Spiropidion and its metabolite could be analyzed with a modified QuEChERS method, and the established method would be widely available to ensure the safety of residual insecticides in Korea.

Development of a Method for Analyzing the Nicotine Content in Synthetic Flavoring Substances as Unauthorized E-cigarette Liquid by Using HPLC (전자담배 액상 충진제와 유사한 합성착향료 중 니코틴의 HPLC 분석법 개발)

  • Kim, Jae-Young;Lee, Sang-Mok;Chang, Moon-Ik;Cho, Yoon-Jae;Lee, Han-Jin;Chae, Young-Sik;Rhee, Gyu-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.693-699
    • /
    • 2013
  • A simple, sensitive, and specific method for quantifying the nicotine content of synthetic favoring substances (SFS) was developed using high performance liquid chromatography (HPLC) with a photo-diode array detector (PDA). Nicotine was extracted from SFS samples by using an acid-base liquid-liquid extraction method with dichloromethane and distilled water. The nicotine content was quantified by HPLC/PDA (261.9 nm) with a $C_{18}$ column under a gradient of 10% acetonitrile with 20 mM ammonium formate (ammonia solution adjusted to pH 8.7) to 100% acetonitrile. The calibration curve, analyzed from concentration standards between 0.1 to 2 mg/L, presented linearity with a correlation coefficient ($r^2$)>0.9999. The limit of quantitation (LOQ) of nicotine in SFS was 0.4 mg/kg, and the average recoveries ranged from 76.4% to 96.3%. The repeatability of measurements, expressed as the coefficient of variation (CV%), ranged from 1.74 to 5.12%. This newly developed method for nicotine quantification in SFS can be considered an analytical method with an acceptable level of sensitivity and repeatability.

Procedures in Establishing Residue Limits of Pesticides on Food Crops in Codex Alimentarius Commission and Foreign Countries (국제기구 및 외국에서 농산물중 농약잔류 허용기준의 설정절차)

  • Lee, Mi-Gyung;Hong, Moo-Gi;Park, Kun-Sang;Choi, Dong-Mi;Lim, Moo-Hyuk;Lee, Su-Rae
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • This study was undertaken to find out necessary measures to improve the tolerance setting system of pesticide residues on food crops in Korea which is scientifically reasonable and harmonizable with international standards. Information on tolerance setting systems of pesticide residues by Codex Alimentarius Commission, Joint FAO/WHO Meeting of Experts on Pesticide Residues, USA, EU, Japan and Taiwan was collected and analyzed. On the basis of information in the above countries, necessary actions to be taken by the Korean regulatory authorities were recommended with respect to priority setting, maximum residue limits (MRLs) setting based on field residue data, group MRLs, minor crop problems, quantitation limit and dietary intake assessment.

Application of ELISA for the Detection of Sulfamethazine Residue in Live Cattle

  • Lee, H.J.;Lee, M.H.;Han, In K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.3
    • /
    • pp.378-381
    • /
    • 2001
  • Sulfamethazine has been widely used in swine for prevention or treatment of infections. Recently, the safety of the drug to consumers has been questioned because of carcinogenic effects. To prevent unwanted drug residues entering the human food chain, both government authorities and industries have established extensive control measures. The demands for reliable, simple, sensitive, rapid and low-cost methods for residue analysis of foods are increasing nowadays. In this study, we established a rapid prediction test for the detection of cattle with violative tissue residues of sulfamethazine. The recommended therapeutic dose of sulfamethazine (withdrawal time, 15 days) was administered to each of 10 cattle. Blood was sampled before drug administration and during the withdrawal period. The concentration of sulfamethazine in plasma, determined by a semi-quantitative ELISA, was compared to that of an internal standard (10 ppb). The absorbance ratio of internal standard to sample (B/Bs) was employed as an index to determine whether drug residues in cattle tissues were negative or positive. That is, a B/Bs ratio less than 1 was considered residue positive and if larger than 1 was considered negative. All 10 plasma samples from non-treated cattle showed negative to sulfamethazine. Sulfamethazine was detected in plasmas of treated cattle until Day 7 of withdrawal period. The present study showed that the semi-quantitative ELISA could be easily adapted in predicting residues of sulfamethazine in live cattle.

Investigation on Pesticide Residues in Agricultural Products in Domestic Markets Using LC-MS/MS and GC-MS/MS (LC-MS/MS 및 GC-MS/MS를 이용한 국내 유통 농산물 중 잔류농약 실태조사)

  • Ji-Yeon Bae;Da-Young Yun;Nam Suk Kang;Won Jo Choe;Yong-Hyeon Jeong;Gui Hyun Jang;Guiim Moon
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.3
    • /
    • pp.131-139
    • /
    • 2023
  • In this study, we investigated pesticide residue levels in 535 domestically distributed agricultural products in South Korea using multi-residue analysis. Agricultural products from 13 regions, including Seoul, were pretreated using QuEChERS and d-SPE, and subsequently analyzed using LC-MS/MS and GC-MS/MS. Residual pesticides were detected in 288 (53.8%) out of the 535 samples, including 40 of apples, 40 of peppers, 33 of mandarins, 31 of peaches, and 144 other commodities. Furthermore, one sample of Korean cabbage exceeded the permitted maximum residue limit (MRL), diniconazole (0.18 mg/kg), detected at about twice the MRL. In total, 91 types of residual pesticides were detected, including fungicides (42), insecticides (48), and a nematicide. The most frequently detected pesticides were dinotefuran (91), carbendazim (75), tebuconazole (61), and pyraclostrobin (59). Our results showed that continuous monitoring of agricultural products is necessary.

Study for Residue Analysis of Fluxametamid in Agricultural Commodities

  • Kim, Ji Young;Choi, Yoon Ju;Kim, Jong Soo;Kim, Do Hoon;Do, Jung Ah;Jung, Yong Hyun;Lee, Kang Bong;Kim, Hyochin
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • BACKGROUND: Accurate and simple analytical method determining Fluxametamid residue was necessary in various food matrices. Additionally, fulfilment of the international guideline of Codex (Codex Alimentarius Commission CAC/GL 40) was required for the analytical method. In this study, we developed Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method to determine the Fluxametamid residue in foods. METHODS AND RESULTS: Fluxametamid was extracted with acetonitrile, partitioned and concentrated with dichloromethane. To remove the interferences, silica SPE cartridge was used before LC-MS/MS (Liquid Chromatography-Tandem Mass Spectrometry) analysis with $C_{18}$ column. Five agricultural commodities (mandarin, potato, soybean, hulled rice, and red pepper) were used as a group representative to verify the method. The liner matrix-matched calibration curves were confirmed with coefficient of determination ($r^2$) greater than 0.99 at calibration range of 0.001-0.25 mg/kg. The limits of detection and quantification were 0.001 and 0.005 mg/kg, respectively. Mean average accuracies were shown to be 82.24-115.27%. The precision was also shown to be less than 10% for all five samples. CONCLUSION: The method investigated in this study was suitable to the Codex guideline for the residue analysis. Thus, this method can be useful for determining the residue in various food matrices as routine analysis.

Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, ong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • An analytical method was developed for the determination of oxytetracycline in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After the samples were extracted with methanol, the extracts were adjusted to pH 4 by formic acid and sodium chloride was added to remove water. Dispersive solid phase extraction (d-SPE) cleanup was carried out using $MgSO_4$ (anhydrous magnesium sulfate), PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed with LC-MS/MS using ESI (electrospray ionization) in positive ion MRM (multiple reaction monitoring) mode. The matrix-matched calibration curves were constructed using six levels ($0.001{\sim}0.25{\mu}g/mL$) and coefficient of determination ($r^2$) was above 0.99. Recovery results at three concentrations (LOQ, $10{\times}LOQ$, and $50{\times}LOQ$, n=5) were from 80.0 to 108.2% with relative standard deviations (RSDs) less than of 11.4%. For inter-laboratory validation, the average recovery was in the range of 83.5~103.2% and the coefficient of variation (CV) was below 14.1%. All results satisfied the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for oxytetracycline determination in agricultural commodities. This study could be useful for safety management of oxytetracycline residues in agricultural products.