• 제목/요약/키워드: drop test

검색결과 1,300건 처리시간 0.028초

흡수식 냉동기용 엘리미네이터의 압력손실 및 액적유입 특성 (Pressure Drop and Refrigerant-Entrainment Characteristics of the Eliminators used in Absorption Chillers)

  • 정시영;류진상;이상수;이정주
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.109-115
    • /
    • 2003
  • The performance of two vertical-blade eliminators (V1, V2) and two horizontal-blade ones (H1, H2) for absorption chillers were tested in terms of pressure drop and refrigerant entrainment. The test was carried out using a wind tunnel with a cross section of 300 mm$\times$300 mm. The pressure drop of four eliminators tested was found to be in the rage of 1.0~2.7mm $H_2O$ at the face velocity of 2m/s. In the refrigerant entrainment test the vertical-blade eliminators showed much better performance than the horizontal-blade ones. The horizontal-blade eliminators showed satisfactory results at the air velocity of 2m/s but exceeded the limit value at 3 m/s. Since the cooling capacity of a machine is lowered by about 2.5% at the pressure drop of 1 m $H_2O$, more researches are required to reduce the pressure drop in the eliminator.

Flow Pattern and Pressure Drop of Pure Refrigerants and Their Mixture in Horizontal Tube

  • Lim, Tae-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권12호
    • /
    • pp.2289-2295
    • /
    • 2005
  • Two-Phase flow pattern and pressure drop data were obtained for pure refrigerants R134a and R123 and their mixtures as test fluids in a horizontal tube. The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section. The flow map of Baker developed for air-water two-phase flow at atmospheric pressure failed to predict the observed flow patterns at the higher value of the mass velocity used in the present study. The map of Kattan et al. predicted the data well over the entire region of mass velocity selected in the present study. The measured pressure drop increased with an increase in vapor quality and mass velocity. A new two-phase multiplier was developed from a dimensional analysis of the frictional pressure drop data measured in the present experiment. This new multiplier was found successfully to correlate the frictional pressure drop.

장기 신뢰성 평가를 위한 태양전지의 열충격 시험 특성에 관한 연구 (The Study on Thermal Shock Test Characteristics of Solar Cell for Long-term Reliability Test)

  • 강민수;김도석;전유재;신영의
    • 에너지공학
    • /
    • 제21권1호
    • /
    • pp.26-32
    • /
    • 2012
  • 본 연구에서는 PV(photovoltaic)모듈에서 경년에 따른 효율 저하의 원인을 분석하기 위해 셀 레벨에서의 열충격 시험을 수행하였다. 열충격 시험의 조건은 $-40^{\circ}C$에서 $85^{\circ}C$로 각각 15분씩 30분을 1사이클로 하였으며, 열충격 시험 500 사이클 동안 100 사이클 간격으로 EL분석 및 I-V분석을 수행하였다. 효율 감소율은 단결정 Bare Cell이 8%, Solar Cell이 9%였으며, 다결정 Bare Cell이 6%, Solar Cell이 13%의 감소율을 보였다. 열충격 시험 후 Solar Cell은 표면 손상으로 인한 효율저하를 확인할 수 있었다. Bare Cell의 경우 표면의 손상이 없었지만, 효율이 저하된 것을 확인할 수 있었다. 이는 Fill Factor 분석에 의해 경년 시 나타나는 누설전류에 의한 소모전력 증가로 효율 저하에 영향을 준 것으로 판단된다. 또한, Bare Cell보다 Solar Cell에서의 효율 감소율이 상대적으로 높게 나타난 결과는 표면 손상 및 소모 전력의 증가로 인해 Solar Cell 효율에 큰 영향을 미치는 것으로 판단된다. 향후 단면 분석법 및 다양한 조건의 시험 기법을 활용하여 PV모듈 뿐 아니라 Cell 레벨에서의 불규칙한 효율 및 Fill Factor의 감소 원인을 검토하고, Solar Cell에서의 효율 저하가 가속되는 원인에 대한 대책 방안 연구가 수행되어야 할 것이다.

드럼 세탁기 포장재 낙하해석 및 완충 특성 (Drop Analysis of a Package and Cushion Performance of Drum Washing Machine)

  • 김창섭;배봉국;성도영
    • 대한기계학회논문집A
    • /
    • 제34권11호
    • /
    • pp.1733-1740
    • /
    • 2010
  • 대형 드럼세탁기의 낙하 충격에 대한 포장재의 동적 거동 분석을 수행하였다. 해석에는 충격 해석에 널리 쓰이고 있는 LS-DYNA를 사용하였으며, 자유 낙하 시의 충격 가속도와 유효 응력, 그리고 고속 카메라를 통한 포장재 압축 변형 비교를 통해 해석 결과의 신뢰성을 검증하였다. 완충 특성 및 포장재 구조 에 대한 파라미터 분석을 통해 기존 포장 구조에 대한 설계 개선안을 도출하였으며, 유통 시험을 통해 유효성을 검증하였다. 본 연구에서 사용한 해석 기법 및 분석 방법 등을 통해, 향후 드럼 세탁기의 완충 성능 및 재료비 개선에 효과적으로 기여할 수 있을 것으로 기대된다.

수평 평활관 및 전열촉진관내 대체 냉매 R-407C의 응축 열전달 특성에 관한 연구 (Heat Transfer Characteristics of R-407C During Condensing Inside Horizontal Smooth and Micro-Fin Tubes)

  • 노건상;오후규
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.210-217
    • /
    • 1999
  • This paper reports the experimental results on heat transfer characteristics of R-22 and R-407C(HFC-32/125/134a 23/25/52 wt%) condensing inside horizontal smooth and finned tubes. The test condensers used In the study are double pipe heat exchangers of 7.5 mm ID, 9.5 mm OD smooth tube, and 60 finned micro-fin tube with 8.53 mm ID, 9.53 mm OD. Each of these tubes was 4 000 mm long tubes connected with an U-bend. These U type two-path test tubes are divided In 8 local test sections for the identification of the local condensing heat transfer characterisitcs and pressure drop, U-bend effects on condensing flows. Inlet quality is maintained 1.0, and refrigerant mass velocity is varied from 102.0 to $301.0kg/m^2{\cdot}s$. From the results, it was found that the pressure drop of the R-407C Increased, and heat transfer coefficient decreased compared to those of R-22. In comparison condensing heat transfer characteristics of micro-fm tube with those of smooth tube, increasing of condensing heat transfer coefficient was found outstanding compared to the increasing ratio of pressure drop. Furthermore, pressure drop In U-bend showed at most a 30 % compared to the total pressure drop in the test section.

수평관내 이산화탄소의 증발 열전달과 압력강하 (Evaporation Heat Transfer and Pressure Drop of Carbon Dioxide In a Horizontal Tube)

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제18권2호
    • /
    • pp.189-196
    • /
    • 2007
  • The evaporation heat transfer coefficient and pressure drop of $CO_2$(R-744) in a horizontal tube was investigated experimentally. The main components of the experimental apparatus are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator(test section). The test section consists of a horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at mass flux of $200{\sim}1000\;kg/m^2s$ saturation temperature of $0{\sim}20^{\circ}C$, and heat flux of $10{\sim}40\;kW/m^2$. The test results showed that the heat transfer coefficient of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much. In comparison with test data and existing correlations, All of the existing correlations for the heat transfer coefficient underestimated the experimental data. However lung et al.'s correlation showed a good agreement with the experimental data. The evaporation pressure drop of $CO_2$ increases with increasing mass flux and decreasing saturation temperature. When comparison between the experimental pressure drop and existing correlations. Existing correlations failed to predict the evaporation pressure drop of $CO_2$.

Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권3호
    • /
    • pp.147-150
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.

저속통제기 외부장착물 분리해석 및 비행시험 (Analysis and Flight Test of XKO-1 Store Separation)

  • 이승수;김상진;김명성
    • 한국항공우주학회지
    • /
    • 제32권5호
    • /
    • pp.24-29
    • /
    • 2004
  • 본 논문에서는 저속통제기로부터 비상 시 분리되는 외부연료탱크 및 LAU-131 로켓발사기의 분리안전성을 보이기 위하여 수행한 자유낙하 풍동시험, MSAP을 이용한 해석과 비행 시험의 연구결과를 종합하였다. 자유낙하형의 bomb rack을 사용하는 비행시험 중의 분리안 전성의 확인과 MSAP의 보정용 자료 생성을 위하여 수행한 아음속풍동을 이용한 자유낙하 시험의 결과에 대하여 기술하였다. 보정된 MSAP으로 자유낙하형과 사출형의 bomb rack 을 사용하였을 때의 분리안전성 해석을 수행하였다. MSAP 해석 결과를 이용한 상관관계 해석을 통하여 자유낙하형의 bomb rack을 사용할 경우의 투하 안전성도 보였다. 또한, 실기 비행시험을 통하여 투하시험을 수행하였으며 이를 해석결과와 비교하였다. 마지막으로, 풍동 시험, 해석결과 및 비행시험의 결과를 종합하여 저속통제기의 안전투하영역을 확정하였다.

모듈타입 충격흡수장치를 위한 재료실험 (Material Tests for Module Type Crash Cushion)

  • 고만기;김기동;성정곤;김진만
    • 한국도로학회논문집
    • /
    • 제10권1호
    • /
    • pp.87-95
    • /
    • 2008
  • 형상이 일정하지 않은 구조에 충돌하는 차량의 탑승자 안전을 확보하기 위해서 그 구조물의 앞에 공간이 허용하는 한도의 깊이만큼 충격을 흡수하는 재료로 만든 모듈을 쌓아두는 방법을 생각할 수 있다. 충격흡수모듈로 사용되기 위해서는 재료가 충분한 에너지 흡수능력을 가져야 하고 동시에 탑승자의 안전을 확보할 수 있어야 한다. 본 논문에서는 에너지 흡수능력과 더불어 탑승자의 안전을 보장하기 위하여 충격흡수재료가 가져야 할 조건을 설명하고 auard-Guard 시스템 모듈, 샌드백, 재활용 타이어, 지오컨테이너, 지오셀 그리고 EPS 블록에 대한 정적압축실험을 실시하여 그 결과를 분석하였다. 이로부터 $30kg/m^{3}$의 밀도를 갖는 EPS 블록이 쿠션모듈로 사용되기 적합한 재료임을 보였다. 한편 시속 35.6km/h까지의 충돌조건으로 Drop Test를 실시하여 EPS블록의 정적특성과 동적특성간 큰 차이가 없음을 보여 주었으며 쿠션모듈로서의 성질을 개선시키기 위한 방안으로 EPS 블록에 공극을 두는 방안을 제안하고 공극이 있는 EPS블록에 대하여 Drop Test를 실시하여 EPS 블록을 이용한 충격흡수시설의 설계에 필요한 재료적 특성치를 제시하였다.

  • PDF

An Experimental Study of Pressure Drop Correlations for Wire-Wrapped Fuel Assemblies

  • Chun, Moon-Hyun;Seo, Kyong-Won;Park, Seok-Ki;Nam, Ho-Yun
    • Journal of Mechanical Science and Technology
    • /
    • 제15권3호
    • /
    • pp.403-409
    • /
    • 2001
  • The main objective of the present study is to perform an experimental evaluation of five existing correlations for the subchannel pressure drop analysis of a wire-wrapped fuel assembly. For this purpose, a series of water experiments have been performed using a helical wire-wrapped 19-pin fuel assembly for various test parameters. Four different test sections with different pitch to rod diameter ratios (P/D) and wire lead length to rod diameter ratios (H/D) have been fabricated. A series of pressure drop measurements were made to obtain friction factors for these four test sections. The new data along with existing data are used to evaluate existing correlations. Both the original and the simplified Cheng and Todreas correlations give the best agreement with experimental data for all flow regions.

  • PDF