• 제목/요약/키워드: drop test

검색결과 1,300건 처리시간 0.029초

고속 전단시험법을 이용한 Sn-37Pb/Cu 와 Sn-37Pb/ENIG 솔더 접합의 기계적신뢰성 평가 (Mechanical Reliability Evaluation of Sn-37Pb Solder/Cu and Sn-37Pb Solder/ENIG Joints Using a High Speed Lap-shear Test)

  • 전성재;현승민;이후정;이학주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.250-255
    • /
    • 2008
  • This study utilized a high speed lap-shear test to evaluate the mechanical behavior of Sn-37Pb/Cu and Sn-37Pb/Electroless Nickel immersion Gold under bump metallization solder joints under high speed loading and hence the drop reliability. The samples were aged for 120 h at different temperatures ($120^{\circ}C,\;150^{\circ}C,\;170^{\circ}C$) and afterward tested at different displacement rates (0.01 mm/s to 500 mm/s) to examine the effects of aging on the drop life reliability. The combination of the stress-strain graphs captured from the shear tests and identifying a fracture mode dominant in the samples for different strain rates leads us to conclude that the drop reliability of solder joints degrades as the aging temperature increases, possibly due to the role of the IMC layer. This study successfully demonstrates that the analysis based on a high speed lap-shear test could be critically used to evaluate the drop reliability of solder joints.

  • PDF

충격시험에 따른 배의 허용낙하높이 추정 (Estimation of Allowable Drop Height for Oriental Pears by Impact Tests)

  • 김만수;정현모;서륜;박일규;황용수
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.461-468
    • /
    • 2001
  • Impact between fruits and other materials is a major cause of product damage in harvesting and handling systems. The oriental pears are more susceptible to bruising than other fruits such as European pears and apples, and are required more careful handling. The interest in the handling of the pears for the processing systems has raised the question of the allowable drop height to which pears can be dropped without causing objectionable damage. Drop tests on pears were conducted using an impact device developed by authors to estimate the allowable drop height without bruising. The impact device was constructed to hold in a selected orientation and to release a fruit by vacuum for dropping on to a force transducer. The drop height was adjustable for zero to 60 cm to achieve the desired distance between the bottom of the fruits and the top of the impact force transducer. The transducer was secured to 150 kg$\sub$f/ concrete block. The transducer signal was sampled every 0.17 ms with a strain gage measurement board in the micro computer where it was digitaly stored for later analysis. The selected sample fruit was Niitaka cultivar of pears which is one of the most promising fruit for export in Korea. The pears were harvested during the 1998 harvest season from an orchard in Daejeon. The sample fruit was selected from two groups which were stored for 3 months and 5 months respectively by the method of current commercial practice. The pears were allowed to stabilize at environmental condition(18$^{\circ}C$, 65% rh) of the experimental room. One hundred fifty six pears were tested from the heights of 5, 7.5. 10 and 12.5 cm while measurement were made of impact peak force, contact time, time to peak force, dwell time, pear diameter and mass. The bioyield strength and modulus of elasticity were measured using UTM immediately after each drop test. The allowable drop height was estimated on the base of bioyield strength of the pears in two ways. One was assumed the peak force during impact test increasing linearly with time, and the other was based on the actual drop test results. The computer program was developed for measuring the impact characteristics of the pears and analyzing the data obtained in the study. The peak force increased while contact times decreased with increasing drop height and contact times of the sample from the hard tissue group. The allowable drop height increased with increasing bioyield strength and contact times, and also varied with Poisson\`s ratio, mass and equilibrium radius of the pears. The allowable drop height calculated by a theoretical method was in the range from 1 to 4 cm, meanwhile, the estimated drop height considering the result of the impact test was in the range from 1 to 6 cm. Since the physical properties of fruits affected significantly the allowable drop height, the physical properties of the fruits should be considered when estimating the allowable drop height.

  • PDF

Effect of Electric Stimulation Training on Walking Ability of Patients with Foot Drop after Stroke

  • Choi, Jongbae;Ma, Sungryoung;Yang, Jongeun
    • 국제물리치료학회지
    • /
    • 제10권4호
    • /
    • pp.1903-1906
    • /
    • 2019
  • Background: Foot drop is a common symptom after stroke and causes walking disorders. Therefore, its proper treatment is important for improving the walking ability of patients with foot drop. Objective: This study aimed to investigate the effects of electrostimulation during walking on the walking ability of patients with foot drop after stroke. Design: Quasi-experial study. Methods: The study enrolled 18 patients with foot drop after stroke. All subjects were assigned to the experimental or control group. The experimental group underwent electric stimulation during walking, while the control group used ankle foot orthoses. Both groups received treatment 20 minutes a day 5 times a week for 4 weeks. Outcome measures were assessed for walking and balance ability using the 10-m walking test (10MWT), 6-min walking test (6MWT), and Timed Up and Go test (TUG) Results: After the intervention, both groups showed significant improvements in 6MWT and TUG results. However, the experimental group showed significantly better improvement on all tests than the control group. Conclusion: The foot drop stimulator effectively improved the walking and balance ability of patients with foot drop after stroke.

ISO 12215-5에 기반 한 레저선박 낙하시험 평가시스템 개발을 위한 기초연구 (The Fundamental Study on the Development of Leisure Boat's Drop Test Management System based on ISO 12215-5)

  • 강남선;박충환
    • 해양환경안전학회지
    • /
    • 제18권4호
    • /
    • pp.365-370
    • /
    • 2012
  • 최근 소형선박 국제표준규격(ISO-12215)이 제정되면서 소형선박-선체구조 및 치수-제5장 부속서 B에 의하여 길이 2.5미터 이상 6미터 미만 소형선박의 낙하시험에 의한 강도시험 기준을 적용할 수 있게 되었으나, 육안검사로 실시되는 현재의 방법으로는 선체 강도 평가의 객관적인 평가가 어려운 문제점이 있다. 본 연구에서는 레저선박의 낙하시험의 정량적 평가가 가능한 평가시스템을 개발하기 위하여 레저선박의 낙하시험에 대한 국내 외 규정을 기반으로 한 낙하시험 평가시스템을 설계하였으며, 5미터급 알루미늄선박의 낙하시험을 통하여 시스템의 적용가능성을 검토하고 낙하 시 선박의 상태 및 낙하자세에 따라 발생되는 문제점을 확인하였다.

Influence of design modification of control rod assembly for Prototype Generation IV Sodium-cooled Fast Reactor on drop performance

  • Son, Jin Gwan;Lee, Jae Han;Kim, Hoe Woong;Kim, Sung Kyun;Kim, Jong Bum
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.922-929
    • /
    • 2019
  • This paper presents the drop performance test of the control rod assembly which is one of the main components strongly related to the safety of the prototype generation IV sodium-cooled fast reactor. To investigate the drop performance, a real-sized control rod assembly that was recently modified based on the drop analysis results was newly fabricated, and several free drop tests under different flow rate conditions were carried out. Then the results were compared with those obtained from the previous tests conducted on the conceptually designed control rod assembly to demonstrate the improvement in performance. Moreover, the drop performance tests under several types and magnitudes of seismic loadings were also conducted to investigate the effect of the seismic loading on the drop performance of the modified control rod assembly. The results showed that the effects of the type and magnitude of the seismic loading on the drop performance of the modified control rod assembly were not significant. Also, the drop time requirement was successfully satisfied, even under the seismic loading conditions.

수평관내 이산화탄소의 증발 압력강하 (Evaporation pressure drop of $CO_2$ in a horizontal tube)

  • 이동건;손창효;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.552-559
    • /
    • 2005
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor qualify, heat flux and saturation temperature. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations. the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

진동대 실험을 통한 보행진동과 뒷꿈치 충격진동의 인지수준 비교 (Investigation on Human Perception Level under Walking and Heel Drop Vibrations Using Shaking Table Test)

  • 한상환;이상욱
    • 한국소음진동공학회논문집
    • /
    • 제13권3호
    • /
    • pp.186-193
    • /
    • 2003
  • Floor vibrations in residence and office buildings are typically induced by heel drop and walking movement of occupants. The criteria of most vibration provisions have been developed based on the vibration caused by heel drop impact rather than walking. There may be considerable differences between the vibration characteristics induced by walking and heel drop. The effect of walking vibration was not well reflected on current provisions. In this paper, shaking table test was performed to investigate the human perception level against the vibrations due to walking and heel drop. This study attempts to compare the human Perception level of two different vibration sources. Also, this study investigates the effect of damping on a Perception level under heel drop and walking vibration.

볼트체결방식의 IP-2형 운반용기의 낙하예비시험 (A Preliminary Drop Test of a Type IP-2 Transport Package with a Bolted Lid Type)

  • 김동학;서기석;박홍윤;이경호;윤정현;이흥영
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 추계 학술대회 논문집
    • /
    • pp.339-347
    • /
    • 2005
  • IP-2형 운반용기는 정상운반조건의 낙하시험을 거친 후에 방사성내용물의 유실 또는 분산이 없고 외부표면에서의 방사선량률이 $20\%$ 이상 증가할 수 있는 차폐능력의 상실이 없어야 한다. 차폐체의 두께가 큰 경우에는, 볼트체결방식을 사용하면 IP형 운반용기로 많이 사용되고 있는 ISO 컨테이너에서의 문을 사용하는 경우보다 방사성내용물의 유실 또는 분산이 일어나지 않을 것이다. 본 연구에서는 볼트체결방식의 IP-2형 운반용기에 대한 낙하시험을 실시하기 전에, 낙하방향에 따른 볼트인장력과 볼트체결력을 시험으로 평가하는 방법을 알아보기 위하여 예비시험모델을 제작하여 시험 및 평가하였다. 바닥과 뚜껑방향의 수직낙하, 수평낙하, 4방향의 경사낙하 등 총 7가지 낙하방향으로 자유낙하를 실시하였다. 낙하충격에 의한 볼트인장력은 힘센서를 이용하여 측정하였고, 볼트체결력은 낙하시험 전의 체결토르크에서 낙하충격 이후의 풀림토르크의 변화를 이용하여 알아보았다.

  • PDF

환형소결체 하나로 조사시험용 무계장 리그의 차압 및 유동유발 진동시험 (Pressure Drop and Flow-Induced Vibration Test for the HANARO Non-instrumented Irradiation Test Rig of Annular Fuel Pellet)

  • 이강희;김대호;방제건
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.281-286
    • /
    • 2007
  • Needs of fuel's performance evaluation for the dual-cooled fuel pellet (annular shape) necessitate the irradiation test in the test reactor. Irradiation test rig for the HARARO reactor, which is a special-purposed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this paper, pressure drop and flow-induced vibration test for the newly developed non-instrumented test rig were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin. The spectral response characteristics of the flow-induced vibration of the test rid were also discussed.

  • PDF

CD-RW Drive의 낙하충격 손상평가 (Damage Evaluation of CD-RW Drive by Drop Test and Simulation)

  • 우재철;윤기원;석기영;김헌영;김상범
    • 대한기계학회논문집A
    • /
    • 제29권1호
    • /
    • pp.81-87
    • /
    • 2005
  • A fracture of hand held device, such as radio, TV and CD-RW drive, mainly occurs due to drop situation. For CD-RW drive, the need of high reading/writing speed in conjunction with low price accelerates the fracture of the device. Computer simulation can reduce the period of development and enhance impact characteristic of device. In this study, the detailed finite element model of CD-RW drive was developed to predict the damage under drop conditions. Material property for shock absorbing damper was obtained from tensile test of raw material. A MOONEY-RIVLIN type rubber in LS-DYNA was used as the material model of damper. To assess the reliability of the developed model, drop test at 200G-2msec and 150G-10msec condition was conducted and acceleration at pick-up was compared.