A Study on the Effect of Compaction Energy on Soil Compaction (흙의 다짐에너지가 다짐효과(效果)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kim, Sang Mok;Kang, Yea Mook
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.1
    • /
    • pp.97-109
    • /
    • 1983
  • In this study, the effects on the soil compaction were investigated through the various testing method by changing the number of layers, the number of blows per layer and drop height. The results obtained in this study were summarized as follows. 1. Soil compaction was largely influenced by maximum grain size of soil in case of small testing mold diameter. 2. The compaction effect showed best in the well graded soil. In this test, compaction effect showed the best value in the soil which contained about 30~40% of particles finer than No. 200 sieves although it would vary according to the content of coarse grained soil. 3. Though the compaction method was changed at the level of compaction energy fixed, the effect of soil compaction showed little. 4. The increment of compaction energy increased the effect of soil compaction, but over a certain limit the soil compaction showed little on the effect. 5. In the method to increase the compaction energy for the purpose of the most reasonable effect, the soil compaction effect was differently shown according to the grain size distribution of the soil.

  • PDF

Evaluating Physical Characteristics of Raindrop in Anseong, Gyeonggi Province (강우입자의 물리적 특성평가: 경기도 안성시 지역을 사례로)

  • KIM, Jin Kwan;YANG, Dong Yoon;KIM, Min Seok
    • Journal of The Geomorphological Association of Korea
    • /
    • v.17 no.1
    • /
    • pp.49-57
    • /
    • 2010
  • To evaluate physical characteristics of open rainfall in Korea, terminal velocity of raindrop and drop size distributions (DSD) were continuously measured using by laser-optical disdrometer around Gosam reservoir, Anseong-si, Gyeonggi-do during three rainfall events from 2008 to 2009. The relationships between kinetic energies (KE, Jm-2mm-1; KER, Jm-2h-1) and rainfall intensity were obtained, respectively. Moreover, we compared the rainfall intensity from a disdrometer with the rainfall intensity from a tipping bucket raingauge to transform the kinetic energy of rainfall using the data from a tipping bucket raingauge. Therefore, the established relationships between kinetic energies (KE and KER) and rainfall intensity could be a useful model to consider the kinetic energy of raindrop using the rainfall intensity below 40mmh-1 of max 5-min rainfall intensity in the middle of South Korea. However, to better examine the relationship between kinetic energy and rainfall intensity, further measurement will be required.

Study on the channel of bipolar plate for PEM fuel cell (고분자 전해질 연료전지용 바이폴라 플레이트의 유로 연구)

  • Ahn Bum Jong;Ko Jae-Churl;Jo Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.15-27
    • /
    • 2004
  • The purpose of this paper is to improve the performance of Polymer electrolyte fuel cell(PEMFC) by studying the channel dimension of bipolar plates using commercial CFD program 'Fluent'. Simulations are done ranging from 0.5 to 3.0mm for different size in order to find the channel size which shoves the highst hydrogen consumption. The results showed that the smaller channel width, land width, channel depth, the higher hydrogen consumption in anode. When channel width is increased, the pressure drop in channel is decreased because total channel length Is decreased, and when land width is increased, the net hydrogen consumption is decreased because hydrogen is diffused under the land width. It is also found that the influence of hydrogen consumption is larger at different channel width than it at different land width. The change of hydrogen consumption with different channel depth isn't as large as it with different channel width, but channel depth has to be small as can as it does because it has influence on the volume of bipolar plates. however the hydrogen utilization among the channel sizes more than 1.0mm which can be machined in reality is the most at channel width 1.0, land width 1.0, channel depth 0.5mm and considered as optimum channel size. The fuel cell combined with 2cm${\times}$2cm diagonal or serpentine type flow field and MEA(Membrane Electrode Assembly) is tested using 100W PEMFC test station to confirm that the channel size studied in simulation. The results showed that diagonal and serpentine flow field have similarly high OCV and current density of diagonal (low field is higher($2-40mA/m^2$) than that of serpentine flow field under 0.6 voltage, but the current density of serpentine type has higher performance($5-10mA/m^2$) than that of diagonal flow field under 0.7-0.8 voltage.

  • PDF

Stress in Olive Flounder (Paralichthys olivaceus) and Fat Cod (Hexagrammos otakii) by the Sudden Drop and Rise of Water Temperature (수온의 급하강과 급상승이 넙치 (Paralichthys olivaceus)와 쥐노래미(Hexagrammos otakii)에 미치는 스트레스)

  • CHANG Young Jin;HUR Jun Wook;LIM Han Kyu;LEE Jong Kwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.2
    • /
    • pp.91-97
    • /
    • 2001
  • The effects of sudden changes of water temperature (WT) on the stress response and physiological change of the cultured olive flounder in large (FL) and small (FS) size, and fat cod (FC) were examined by manipulating WT (2 types) in a flow through seawater culture system with 6 tanks (water vol. 270 L/tank). The WT was decreased from $20^{\circ}C$ to $10^{\circ}C$ within 5 hours ($2^{\circ}C/hour$) and maintained at $10^{\circ}C$ for 21 hours (Exp. I), and it was raised from $20^{\circ}C$ to $30^{\circ}C$ within 5 hours and maintained at $30^{\circ}C$ for 21 hours (Exp.II). In Exp. I, the levels of blood hematocrit at 5 hours ($10^{\circ}C$) in FS was significantly decreased from $13.5\pm2.0\%\;to\;11.3\pm2.3\%$, but FC at 2.5 hours ($15^{\circ}C$) ($19.0\pm0.3\%\;to\;23.2\pm3.8\%$) was increased, The blood hemoglobin concentration of all fish in Exp, II was significantly increased until 8 hours after raising WT from $20^{\circ}C$ to $30^{\circ}C$. In Exp. I and II , the levels of plasma cortisol in FL, FS and FC was changed from $5.2\pm8.5ng/mL,\;4.4\pm4.5ng/mL\;and\;2.7\pm0.4ng/mL$, respectively, before sudden drop and rise of WT. The levels of plasma cortisol of in FL ($164.0\pm53.1ng/mL$) and FC ($207.9\pm25.4ng/mL$) were significantly increased by the lowering WT sharply during whole experiment. The FL ($12.6\pm2.0ng/mL$) and FS ($4.0\pm3.9ng/mL$) showed no significant differences in cortisol level according to sudden rise of WT (5 hours). But it in FC ($44.7\pm18.2ng/mL$) was increased. In Exp. I, the plasma glucose levels of all fish groups were decreased after 5 hours ($10^{\circ}C$), The plasma lactic acid concentration of FL and FS showed no significant differences until 5 hours after raising WT from $20^{\circ}C$ to $30^{\circ}C$, But it in FC was significantly increased with WT raise.

  • PDF

Rootzone Profile, Trickle Irrigation System and Turfgrass Species for Roof Turf Garden (옥상녹화에 적합한 지반, 점적 관수 및 잔디 선정)

  • 이재필;한인송;주영규;윤원종;정종일;장진혁;김두환
    • Asian Journal of Turfgrass Science
    • /
    • v.17 no.4
    • /
    • pp.155-163
    • /
    • 2003
  • This study was conducted to find out suitable rootzone profile, irrigation system, and turfgrass species for roof turf garden. Treatments of profile with soil amendment were Mixture I: Perlite(PL)60%+Vermiculite(VC)20%+Peatmoss(PM)20%, Mixture II: PL60%+VC 10%+PM20%+Sand(SD)10%, Mixture III: PL60%+VC20%+PM20% and Mixture IV: PL60%+VC10%+PM20%+SD10%+Styrofoam 5cm as a drain layer. To test trickle irrigation for roof garden, intervals of main pipe spacing(50cm, 100cm) and drop hole distance(15, 20, 30, 50 and 100cm)were treated, To select most suitable turfgrass species or mixture, Bermudagrass 'Konwoo', Zoysiagrass 'Konhee' and cool-season grass(Kentucky Bluegrass 80% + Perennial Ryegrass 20%, Tall Fescue 30% + KB50% + PR 20%)were tested. In particle size analysis, the soil amendments Perlite and vermiculite showed very even distribution, however, peatmoss contained mostly coarse particles with fiber over $\Phi$ 4.75mm. Under field moisture condition, vermiculite and peatmoss showed 350% water holding capacity, on the other hand, sand or Perlite showed 115% and 166%, respectively. Total weight of soil profile was 139.2kg/$m^2$ with Styrofoam drain layer without sand, which showed most lightest among treatments. Turf quality also resulted positve with Styrofoam drain layer installation. On trickle irrigation system, the proper interval of main drain pipe spacing and drop hole distance were 50cm and 50cm, respectively, In irrigation frequency, once per a day for 15 minute irrigation with 2 1/hr showed the best results on turf quality. Among turfgrass species or cool season grass mixture, warm season turfgrass fine leaf type zoysiagrass 'Konhee' and Bermudagrass 'Konwoo' showed very acceptable result on all over the treatments of rootzone and irrigation system. To apply cool season grasses for the roof garden, advanced researches may be needed to establish the proper soil amendment, rootzone profile, and irrigation system, Application of Bermudagrass 'Konwoo' for roof turf garden also needs successive tests to overcome winter injuries.

A Quantification Method for the Cold Pool Effect on Nocturnal Temperature in a Closed Catchment (폐쇄집수역의 냉기호 모의를 통한 일 최저기온 분포 추정)

  • Kim, Soo-Ock;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.4
    • /
    • pp.176-184
    • /
    • 2011
  • Cold air on sloping surfaces flows down to the valley bottom in mountainous terrain at calm and clear nights. Based on the assumption that the cold air flow may be the same as the water flow, current models estimate temperature drop by regarding the cold air accumulation at a given location as the water-like free drainage. At a closed catchment whose outlet is blocked by man-made obstacles such as banks and roads, however, the water-like free drainage assumption is no longer valid because the cold air accumulates from the bottom first. We developed an empirical model to estimate quantitatively the effect of cold pool on nocturnal temperature in a closed catchment. In our model, a closed catchment is treated like a "vessel", and a digital elevation model (DEM) was used to calculate the maximum capacity of the cold pool formed in a closed catchment. We introduce a topographical variable named "shape factor", which is the ratio of the cold air accumulation potential across the whole catchment area to the maximum capacity of the cold pool to describe the relative size of temperature drop at a wider range of catchment shapes. The shape factor is then used to simulate the density profile of cold pool formed in a given catchment based on a hypsometric equation. The cold lake module was incorporated with the existing model (i.e., Chung et al., 2006), generating a new model and predicting distribution of minimum temperature over closed catchments. We applied this model to Akyang valley (i.e., a typical closed catchment of 53 $km^2$ area) in the southern skirt of Mt. Jiri National Park where 12 automated weather stations (AWS) are operational. The performance of the model was evaluated based on the feasibility of delineating the temperature pattern accurately at cold pool forming at night. Overall, the model's ability of simulating the spatial pattern of lower temperature were improved especially at the valley bottom, showing a similar pattern of the estimated temperature with that of thermal images obtained across the valley at dawn (0520 to 0600 local standard time) of 17 May 2011. Error in temperature estimation, calculated with the root mean square error using the 10 low-lying AWSs, was substantially decreased from $1.30^{\circ}C$ with the existing model to $0.71^{\circ}C$ with the new model. These results suggest the feasibility of the new method in predicting the site-specific freeze and frost warning at a closed catchment.

Characteristic of Raindrop Size Distribution Using Two-dimensional Video Disdrometer Data in Daegu, Korea (2차원 광학 우적계 자료를 이용한 대구지역 우적크기분포 특성 분석)

  • Bang, Wonbae;Kwon, Soohyun;Lee, GyuWon
    • Journal of the Korean earth science society
    • /
    • v.38 no.7
    • /
    • pp.511-521
    • /
    • 2017
  • This study analyzes Two-dimensional video disdrometer (2DVD) data while summer 2011-2012 in Daegu region and compares with Marshall and Palmer (MP) distribution to find out statistical characteristics and characteristics variability about drop size distribution (DSD) of Daegu region. As the characterize DSD of Daegu region, this study uses single moment parameters such as rainfall intensity (R), reflectivity factor (Z) and double moment parameters such as generalized characteristics number concentration ($N{_0}^{\prime}$) and generalized characteristics diameter ($D{_m}^{\prime}$). Also, this study makes an assumption that DSD function can be expressed as general gamma distribution. The results of analysis show that DSD of Daegu region has ${\log}_{10}N{_0}^{\prime}=2.37$, $D{_m}^{\prime}=1.04mm$, and c =2.37, ${\mu}=0.39$ on average. When the assumption of MP distribution is used, these figures then end up with the different characteristics; ${\log}_{10}N{_0}^{\prime}=2.27$, $D{_m}^{\prime}=0.9mm$, c =1, ${\mu}=1$ on average. The differences indicate liquid water content (LWC) of Daegu distribution is generally larger than MP distribution at equal Z. Second, DSD shape of Daegu distribution is concave upward. Other important facts are the characteristics of Daegu distribution change when Z changes. DSD shape of Daegu region changes concave downward (c =2.05~2.55, ${\mu}=0.33{\sim}0.77$) to cubic function-like shape (c =3.0, ${\mu}=-0.13{\sim}-0.33$) at Z > 45 dBZ. 35 dBZ ${\leq}$ Z > 45 dBZ group of Daegu distribution has characteristics similar to maritime cluster of diverse climate DSD study. However, Z > 45 dBZ group of Daegu distribution has a difference from the cluster.

Effect of GA3 Treatment on Bud Formation, Fruit Set, and Enlargement in Ardisia pusilla (GA3에 의한 산호수의 화아형성과 착과 및 비대 증진효과)

  • Kil, Mi-Jung;Huh, Yeun-Joo;Kwon, Young-Soon
    • Horticultural Science & Technology
    • /
    • v.29 no.6
    • /
    • pp.555-560
    • /
    • 2011
  • The objective of this study was carried out to investigate the proper plant growth regulator for increasing the number of flower, fruit set, and to enlarge the size of the berries in Ardisia pusilla. Flower bud formation was used rooted cutting, and fruit set, enlargement, and coloration of fruit were used with two years-old. $GA_3$ concentrations were treated with 0, 100, 200, or $400mg{\cdot}L^{-1}$. Flower bud formation was effective in $400mg{\cdot}L^{-1}$ $GA_3$ and it was 1.8 times greater than control. Plant growth regulators were applied by foliar spray at full bloom stage to increase the fruit set. As a result, $GA_3$ was the most effective for increasing fruit set. Also, auxins of 4-CPA (Tomatotone, Donbu hitech Co., Korea) and dichloprop triethanol amine (Antifall, Bayer Crop Science Co., Ltd., Korea) were effective. When $GA_3$ concentrations of 0.5 and $1.0mg{\cdot}L^{-1}$ were used, fruit set (%) reached to 70% and 77%, respectively. Effectiveness of $GA_3$ was 1.8 times greater than control. Also, auxins, dichloprop triethanol amine increased to about 7-12% during fruit setting, but cytokinin and anti-gibberellin were ineffective. To investigate the fruit enlargement and coloration, $GA_3$ was treated with 0.3, 0.6, and $1.2mg{\cdot}L^{-1}$. Fruit enlargement was achieved to about 15% by $GA_3$ $0.6mg{\cdot}L^{-1}$ when $GA_3$ was treated 3 times at the interval of 1 month per treatment when fruit size was about 2-3mm (after full-blooming two months). But anthocyanin contents for coloration of fruit skin were not significant according to $GA_3$ concentration. The results showed that $GA_3$ enhanced bud formation, fruit set and enlargement of fruit size in Ardisia pusilla.

CPFD Simulation of Bubble Flow in a Bubbling Fluidized Bed with Shroud Nozzle Distributor and Vertical Internal (CPFD 시뮬레이션을 통한 Shroud 노즐 및 수직 구조물이 설치된 기포 유동층 반응기 내에서의 기포 흐름 해석)

  • Lim, Jong Hun;Bae, Keon;Shin, Jea Ho;Lee, Dong Ho;Han, Joo Hee;Lee, Dong Hyun
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.678-686
    • /
    • 2016
  • The effect of internal and shroud nozzle distributor to bubbling fluidized beds which has the size of $0.3m-ID{\times}2.4m-high$ column was modeled by CPFD (Computational Particle-Fluid Dynamics). Metal-grade silicon particles (MG-Si) were used as bed materials which have $d_p=149{\mu}m$, ${\rho}_p=2,325kg/m^3$ and $U_{mf}=0.02m/s$. Total bed inventory and static bed height were 75 kg and 0.8 m, respectively. Effect of vertical internal on the bubble rising velocity was investigated. Bubbles were split by internal when the axial position of the internal from the distributor, z = 0.45 m. Bed pressure drop and axial solid holdup were not affected by internal. However, in the case that axial distance of internal from distributor was too close to jet penetration length, bubbles were not separated and bypassed internal, and faster than without internal or z = 0.45 m.

Improvement Effect and Field Application of Dynamic Replacement Using Crushed Rock (암버력 매립층의 동치환공법 현장 적용성 및 개량효과에 관한 연구)

  • Lee, In-Hwan;Lee, Chul-Hee;Shin, Eun Chul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.1-13
    • /
    • 2019
  • The purpose of this study is to examine the effect of soft ground improvement by dynamic replacement with utilizing crushed rock. In order to understand the ground improvement effect when applying dynamic replacement method with crushed rock, the laboratory test and field test were performed. The internal friction angle and apparent cohesion were derived through direct shear test. The dynamic replacement characteristics were identified by analyzing the weight, drop, and number of blows needed for dynamic replacement. Through the field plate bearing test and density test, the bearing capacity and settlement of the improved ground were measured, and the numerical analysis were conducted to analyze the behavior of the improved ground. In this study, it proposes modified soil experimental coefficient(CDR) to 0.3~0.5 in the dynamic replacement method with crushed rock. Also when applying the dynamic replacement method using crushed rock, the particle size range is less than 100 mm, D90 is less than 80 mm and D15 is more than 30 mm.