• Title/Summary/Keyword: drinking groundwater

Search Result 239, Processing Time 0.021 seconds

Cognition on Quality and Cost of Small Drinking Water Plants in Gyungbuk Region (경북지역 소규모수도시설 이용자의 수질.비용에 대한 인식)

  • Kang, Mee-A;Yang, Myeong-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.675-682
    • /
    • 2010
  • Groundwater is an essential drinking water source in Gyungbuk, South Korea. The primary source of nitrate in groundwater is from nitrogen fertilizers. Efficient management of a small drinking water plant requires a good understanding of its status such as the objective and the cognition of users. The objective of this study is to understand user situation and produce useful user-friendly policy based on user cognition. Most people who participated in this study, should take their groundwater from a good quality source. Even though they would like to have a good facility for getting safe water, they were reluctant to do it due to the cost used. It means that people who drink groundwater have no idea that health safety is affected by groundwater quality. The volume used depended upon personal activities such as agriculture and stockbreeding. We can easily find groundwater with nitrate that exceeds drinking water standards. Therefore, we have to carry out groundwater management with two categories ; 1) drinking water only and 2) others according to objectives in small drinking water systems.

A Study on the Characteristics of Water Quality for Groundwater and Purified Water of Several Schools in Gyeongsangbukdo Province (경상북도지역 학교지하수 및 정수기통과수의 수질특성에 관한 연구)

  • Kim, Suk-Chan;Bae, Hun-Kyun
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.575-580
    • /
    • 2011
  • This study characterized water quality of groundwater and purified water used for drinking water in 30 schools in Gyeongsangbukdo Province. The results of the study showed that 43% of groundwater and 45% of purified water were not suitable for drinking. Among them, microbial contaminations were the most serious problem. In raw groundwater, the exceeding rates of total colony counts was the highest in August (53.6%). Purified water samples showed higher rate of exceeding drinking water standard for total colony counts while showing lower rate of exceeding drinking water standard for total coliforms and fecal coliforms in March and August. Overall, proper managements for microbial contaminations are required for both groundwater and purified water. Furthermore, special attention should toward students not to drink water when groundwater or purified water exceeds the drinking water quality standard.

The characteristics of the Groundwater Quality in Seoul (서울시 지하수 수질특성에 관한 연구)

  • 김익수;엄석원;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.225-228
    • /
    • 2003
  • For the purpose of finding out the distributions of groundwater uses, the effect of facilities on the parameter and the correlations among measurements, various statistical analysis were carried out with the data of groundwater quality measurements from January to December in 2002. 1. The rates of groundwater for drinking water were 10.5% in Yangcheon-Gu, 10.2% in Kangdong-Gu, and 9.9% in Eunpyung-Gu. The rates of other uses of groundwater were shown to be 58.1%(786 wells) for civil defense emergency, 22.1%(299 wells) for contamination-concerning, 9.8%(133 wells) for water quality monitoring, consisting of 90% of all groundwater. 2. The 52.6% of groundwater for drinking were demonstrated to be appropriate while 91.9% for tither uses-domestic, industrial, agricultural uses- were shown to be proper. 3. For drinking water, the average values of colar, turbidity, NH3-N, F, and Fe were 11.216 degree, 2.138 NTU, 2.458mg/l, 0.212mg/1 and 0.507mg/1 respectively. 4. In cases of drinking water wells for emergency, the results of statistical analysis showed that building year of the wells, depth and pumping rate didn't affect on whether it was proper for that use or not. It were shown that there were linear correlations between depth and NO$_3$-N(-0.171) and F ̄(0.332) while the correlation coefficients were 0.381 and -0.169 between the building year of well and depth and pumping rate respectively.

  • PDF

Assessment of drinking water quality and its health impact on local community in coastal belt Karachi

  • Samo, Saleem Raza;Channa, Raja Siraj Ahmed;Mukwana, Kishan Chand
    • Advances in environmental research
    • /
    • v.6 no.3
    • /
    • pp.203-216
    • /
    • 2017
  • For survival of human beings clean water is an essential commodity whereas contamination in drinking water threatens to mankind. The main cause of water contamination is social and development activities of human being along with increasing population. The community in the study area has acute shortage of drinking water along with about 40 to 60% has no access to safe drinking water. This study indicates drinking water quality of two major sources of coastal belt of Karachi one is supplied by Karachi Water & Sewerage Board (KWSB) as tap water and the other through groundwater. The physicochemical analysis was carried out by following the standard methods for checking the quality of drinking water. The analyzed results showed that the quality of groundwater was unfit as potable water. The most critical situation was observed as high level of contamination followed by high turbidity and increased salinity levels. TDS in surface water were found 12% above and TDS in groundwater was 20% below the National Drinking Water Quality Standards (NDWQS) of Pakistan as well as the permissible WHO drinking water quality guidelines.

The Genetic Diversity of Bacterial Communities in the Groundwater (지하수 세균 군집의 유전적 다양성)

  • 김여원;민병례;최영길
    • Korean Journal of Environmental Biology
    • /
    • v.18 no.1
    • /
    • pp.53-61
    • /
    • 2000
  • In order to characterize the genetic diversity of bacterial community in groundwater, samples were collected from used for drinking water and polluted with heavy metal wastewater in Seoul city and natural cave of Kangwondo. The DNA was amplified with 165 rDNA-based primers by use of the PCR, and then analysed ARDRA (amplified ribosomal DNA restriction analysis). Restriction endonuclease analysis patterns of amplified 165 rDNA in drinking water and wastewater relatively showed high genetic diversity in situ and drinking groundwater. The number of DNA fragments varied with in situ and drinking water. This method of ARDRA of bacterial communities in groundwater could be used for a quick assessment of genotypic changes between different locations reflecting different environmental conditions and the diversity reflected pollution of groundwater (natural cave water>drinking water>waste water, as in order of grade). [Genetic diversity, Groundwater, 165 rDNA, PCR, ARDRA].

  • PDF

Chemical Ranking and Scoring Methodology for the Drinking and non-drinking Groundwater pollutants: CROWN (Chemical Ranking of Groundwater PollutaNts) (음용 및 비음용 지하수 우선관리대상 항목 선정기법: CROWN (Chemical Ranking of Groundwater PollutaNts))

  • An, Youn-Joo;Lee, Woo-Mi;Jeong, Seung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.16-25
    • /
    • 2013
  • The Korean groundwater law regulates 20 groundwater contamination parameters, including 14 specific harmful substances. Expanding the number of groundwater quality standards are needed to cope with recent groundwater quality deterioration due to the use of various chemicals. Chemical ranking and scoring system (CRS) is a scientific tool to sort priority chemicals by considering exposure and toxicity potentials. In this study, we developed a CRS for scoring and ranking of possible groundwater pollutants and screened priority substances to be later considered in the Korean standard expansion. Chemical Ranking Of groundWater pollutaNts (CROWN) incorporates important parameters consisting of exposure potential, human and water ecotoxicity, interests, and certainty. Furthermore, CROWN additionally evaluated existence of other media standards to consider impacts by contamination of other media. The 197 substances that were common to 9 countries were selected first. CROWN evaluated and ranked each chemical, and finally suggested priority substances. Suggested priority substances were classified into two groups according to the groundwater use purposes: drinking and non-drinking. The priority substances were further classified into $1^{st}$ and $2^{nd}$ group priorities. The $1^{st}$ group consists of 75 substances, including the all the Korean groundwater standard parameters. CROWN will be used in selecting groundwater pollutants for possible inclusion in the Korean standard expansion.

Establishment of Non-drinking Groundwater Quality Standards: General Contamination Substances (비음용 지하수 오염물질 기준설정체계 구축 연구: (2) 일반오염물질)

  • An, Youn-Joo;Nam, Sun-Hwa;Jeong, Seung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.24-29
    • /
    • 2014
  • To data, there was no systematic basis for establishing the content and allowed levels of general contamination substances in the Korean groundwater quality standards for non-drinking water. Recently, use of specific procedures for deriving valid groundwater quality standards have become mandatory. This study first investigated the methodology for deriving groundwater quality standards in the European Commission (EC), considering background groundwater quality and domestic and international standards related to water quality. Furthermore, this study investigated the existing specified procedure of standards related to water quality (e.g. surface water, drinking water, and wastewater). Our findings showed that EC and Member States presented the methods for deriving groundwater threshold values for general chemicals. Finally, we have proposed the following procedures of deriving Korean groundwater quality: (1) Selection of groundwater pollutant population, (2) selection and monitoring of priority substances, (3) monitoring, (4) selection of groundwater quality standard candidates, (5) selection of new substances and values for groundwater quality standards.

The Characteristics of Drinking Groundwater Quality in Chung Cheong Nam Do (충청남도 음용지하수 수질의 특성)

  • 김흥락;한운수;박혜숙
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.721-727
    • /
    • 2002
  • The characteristics of drinking groundwater quality at Chung Cheong Nam Do was analyzed by investigating the 3,086 groundwater data which were carried out the water quality inspection from Jan. 1998 to Dec. 1998. It was found that all the mean concentration of items was not over the drinking water quality standard except Zn at Yeongee area. The highest mean concentration of nitrate was $8.2 mg/{\ell}$ at Hongsung area. And the mean concentrations of nitrate and ammonium at Sucheon, Yesan, Yeongee were relatively higher. It was considered that the groundwater of that area was contaminated by breeding livestock as farm pollutants. The mean concentrations of chloride, hardness and evaporation residual at coastal regions were higher than inland regions. Especially the mean concentration of chloride was 2.5 times higher. It was considered that the groundwater at coastal regions was affected by seawater. It was found that the correlation between Fe and Mn was relatively high(r=0.776) and the correlation between hardness and evaporation residual was very high(r=0.983). The rainfall series and detection rate of E-coli had the hydrologic persistence. The correlation between the detection rate and rainfall series over 150 mm was very high (r=0.9146). Therefore it is surely required to control the groundwater sanitation in the rainy season.

Contamination status of groundwater used as livestock drinking in beef and dairy cattle farms, Korea (국내 소사육농가의 자가용 가축음용수 오염실태 평가조사)

  • Jang, Yangho;Lee, Soojin;Kim, Hyobi;Lee, Jeonghak;Lee, Manho;Gil, Hyekyoung;Choe, Nonghoon
    • Korean Journal of Veterinary Research
    • /
    • v.51 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • In Korea, groundwater is main water source in livestock farms. Most dairy and cattle farms have constructed their own wells for human drinking and livestock farming. However, these private residential wells have not been controlled by government and also there was scant study about livestock drinking water quality. Therefore this study was to monitor of the livestock farms' groundwater quality in Korea. Water samples were collected at 123 dairy and cattle farms and were analysed forty six substances with quality standard for drinking water approved by the Minister of Environment. Seventy eight (63.4%) of 123 samples failed to drinking water stand a test. The most frequent contaminants were nitrate-nitrogen and microbial. 22.8% (n=28) of samples showed nitrate-N concentration of higher than 10 mg/L meant that can't be used drinking water for human and the Nitrate-N concentration analysed in the range of 0.2 to 61.2 mg/L. All of 78 failed to drinking samples had microbial problems, especially 5.7% (n=7) of samples indicated water could be contaminated by feces. Other contaminants detected were zinc and evaporation residue. Especially detected zinc concentration (32 mg/L) was about ten times higher than standard of zinc (3 mg/L). Regression analysis indicated that groundwater pH did not influence to nitrate-N concentration but the hardness and chloride could affect to nitrate-N concentration in the groundwater. Most livestock farms were adjacent to crop farmland in Korea. This could cause contamination of groundwater with nitrate-N and pesticide that could accumulate livestock product. Moreover Heavy metal such as zinc and copper could be released from a corrosive plated water pipe in livestock farm. Put together, Korea livestock system is indoor, not pasture-based, hence livestock could be exposed to potential contaminated water consistently. Therefore on the basis of these data, appropriate livestock drinking water quality standards should be prepared to keep livestock healthy and their product safe. Further, livestock drinking water quality should be monitored continuously in suitable livestock drinking water standards.

Abundances of Uranium and Radon in Groundwater of Taejeon Area (대전지역 지하수에 함유된 우라늄 및 라돈의 함량)

  • Han, Jeong-Hee;Park, Kye-Hun
    • Economic and Environmental Geology
    • /
    • v.29 no.5
    • /
    • pp.589-595
    • /
    • 1996
  • The concentration of radioactive elements was measured from the groundwater samples of Taejeon Area. U and Rn concentrations of very high level were detected from many places, especially around Yusung. These levels are much higher than the concentration standards for the drinking water proposed by the United States Environmental Protection Agency. However, in Korea, there are no standard levels for the radioactive elements in drinking water yet. We think that it is necessary to provide such standards as soon as possible, and that the determination of radioactive elements in groundwater should be included in the routine analysis items for the drinking water quality, because many people currently use such relatively high level radioactive groundwater as their drinking water, especially around Yusung area.

  • PDF