• Title/Summary/Keyword: drilling force

Search Result 157, Processing Time 0.035 seconds

Cutting force regulation of microdrilling using the sliding mode control (슬라이딩 모드 제어를 이용한 마으크로 드릴의 절삭력 제어)

  • 정만실;조동우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.842-846
    • /
    • 1997
  • Micro-hole drilling (holes less than 0.5 mm in diameter with aspect ratios larger than 10) is gaining increased attention in a wide spectrum of precision production industries. Alternative methods such as EDM, laser drilling, etc. can sometimes replace mechanical micro-hole drilling but are not acceptable in PCB manufacture because they yield inferior hole quality and accuracy. The major difficulties in micro-hold drilling are related to wandering motions during the inlet stage, high aspect ratios, high temperature,etc. However, of all the difficulties, the most undesirable one is the increase of drilling force as the drill penetrates deeper into hold. This is caused mainly by chip related effects. Peck-drilling is thus widely used for deep hole drilling despite the fact that it leads to low productivity. Therefore, in this paper, a method of cutting force regulation is proposed to achieve continuous drilling. A proportional plus derivative (PD) and a sliding modecontrol algorithm will be implemented for controlling the spinle rotational frequeency. Experimental results will show that sliding mode control reduces the nominal cutting force and its variation better than the PD control, resulting in a number of advantages such as an increase in drill life, fast stabilization of the wandering motion, and precise positioning of the hole.

  • PDF

누적외상병 예방을 위한 Drilling 작업 빈도에 관한 연구

  • 김철홍
    • Proceedings of the ESK Conference
    • /
    • 1994.04a
    • /
    • pp.41-48
    • /
    • 1994
  • A laboratory experiment was conducted to examine the effect of varying working conditions on drilling frequendcy for females. Results of ANOVA showed that angle of wrist flexion and force had significant effects on drilling frequency. As angle ofwrist flexion and force increased drilling frequency decreased significantly. A set of 4 regression models were developed to predict maximum acceptable frequency (MAF) for drilling as a function of wrist flexion angle, force, and various physiological measures with could be applied in industrial situations

  • PDF

Diagnosis and Control of Machining States in Micro-Drilling for Productivity Enhancement (미세구멍 가공의 생산성 향상을 위한 상태식별 및 제어)

  • 정만실;조동우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.117-129
    • /
    • 1998
  • Micro-hole drilling (holes less than 0.5 mm in diameter with aspect ratio larger than 10) is recently having more attention in a wide spectrum of precision production industries. Alternative methods such as EDM. laser drilling, etc. can sometimes replace the mechanical micro-hole drilling but are not acceptable in PCB manufacture because of the inferior hole quality and accuracy. The major difficulties in micro-hole drilling are related to small signal to noise ratios, wandering motions of the inlet stage, high aspect ratios, high temperatures and so forth. Of all the difficulties. the most undesirable one is the increase of drilling force as the drill proceeds deeper into the hole. This is caused mainly from the chip effects. Peck-drilling is thus widely used for deep hole drilling despite that it suffers from low productivity. In the paper, a method of cutting force regulation is proposed to achieve continuous drilling. A PD and a sliding mode control algorithms were implemented through controlling the spindle rotating frequency. Experimental results show that the sliding mode control reduces the nominal cutting force and the variation of the cutting force better than the PD control. The advantages of the regulation, such as increase of drill life, fast stabilization of a wandering motion, and the precise positioning of the hole are verified in experiment.

  • PDF

Critical thrust force and feed rate determination in drilling of GFRP laminate with backup plate

  • Heidary, Hossein;Mehrpouya, Mohammad A.;Saghafi, Hamed;Minak, Giangiacomo
    • Structural Engineering and Mechanics
    • /
    • v.73 no.6
    • /
    • pp.631-640
    • /
    • 2020
  • Using backup plate is one of the most commonly used methods to decrease drilling-induced delamination of composite laminates. It has been shown that, the size of the delamination zone is related to the vertical element of cutting force named as thrust force. Also, direct control of thrust force is not a routine task, because, it depends on both drilling parameters and mechanical properties of the composite laminate. In this research, critical feed rate and thrust force are predicted analytically for delamination initiation in drilling of composite laminates with backup plate. Three common theories, linear elastic fracture mechanics, classical laminated plate and mechanics of oblique cutting, are used to model the problem. Based on the proposed analytical model, the effect of drill radius, chisel edge size, and backup plate size on the critical thrust force and feed rate are investigated. Experimental tests were carried out to prove analytical model.

Drilling Characteristics and Modeling of Diamond Core Drilling Processes (다이아몬드 코어드릴 공정의 구멍가공 특성과 모델링)

  • Yoon, Kwan-Woo;Chung, Sung-Chong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.95-103
    • /
    • 2008
  • Diamond core drills are applied to drill difficult-to-cut materials. This paper proposes basic understanding of ceramic drilling mechanics and characteristics of main factors affecting tool life, tool wear, cutting force, and chipping thickness. In contrast to conventional drilling, the core drilling process make deep grooves on the workpiece. One difficulty of it is the evacuation of chips from the drilled groove. As the drilling depth increases, an increased amount of chips tend to cluster together and clog the groove. Eventually severe wear develops and diamond grits are separated from the drill body. To relieve the clogging problem and to evacuate chips from the groove easily, the helical drilling process is applied for the core drilling process. To analyze drilling characteristics and derive optimal drilling conditions, tool life, tool wear, cutting force, and chipping thickness are quantified through the monitoring system and the Taguchi method. Mathematical models for the tool life and chipping thickness are derived from the response surface method. Optimal drilling database has been constructed through the experimental models.

Evaluation of Cutting force and Surface accuracy on Drilling process by Temperature variation (온도 변화에 따른 드릴가공의 절삭력 변화와 가공정밀도 평가)

  • 이상천;정우섭;백인환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.895-898
    • /
    • 1997
  • These days, most of new materials, which is in use widely as cutting process materials have a characteristic in common. That is hard cutting. So, it happens that hardness by cutting temperature. And hardness on cutting process has an effect on tool wear or life shortness of tools. To solve these problems hot-machining is proposed. When a material is heated, organization of material is soften. So cutting process becomes easy. When such a hot-machining method applies on drilling process and then heated material is processed, cutting force is less than usual drilling process cutting force. In this paper, when a material is heated, cutting force on drilling process is measured. It is decided that the best suitable temperature area. And it suggest that the better hot-machining condition as surface accuracy is measured.

  • PDF

A Study on the Characteristics of Deep Hole Drilling Process Using Single Edge Drill with Small Diameters (미소직경의 Single Edge형 드릴을 사용한 심공드릴링 공정의 가공특성에 관한 연구)

  • 최성주;이우영;박원규
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • Applications of the deep hole drilling process can be found in many industries ranging from large aerospace manufacturer to small tool and die shop. Deep hole drilling process with small diameter generally requires high quality and accuracy. But problems which may arise or result from the deep hole drilling process include drill breakage, the generation of a finished part surface which does not satisfy required quality, and process instability. To guaranty the required machining quality and accuracy, it is important to understand and improve the deep hole drilling process. In this study, deep hole drilling experiments using tingle edge drill with small diameter under 2mm have been carried out for difficult to cut materials such as C42CrMo4 and C45pb and the experimental results were analyzed. Feed force and torque versus feed showed linear relationship in both materials. The feed force and torque are decreased as cutting speed is increased but the trends are not uniform in C42CrMo4.

Experimental and numerical FEM of woven GFRP composites during drilling

  • Abd-Elwahed, Mohamed S.;Khashaba, Usama A.;Ahmed, Khaled I.;Eltaher, Mohamed A.;Najjar, Ismael;Melaibari, Ammar;Abdraboh, Azza M.
    • Structural Engineering and Mechanics
    • /
    • v.80 no.5
    • /
    • pp.503-522
    • /
    • 2021
  • This paper investigates experimentally and numerically the influence of drilling process on the mechanical and thermomechanical behaviors of woven glass fiber reinforced polymer (GFRP) composite plate. Through the experimental analysis, a CNC machine with cemented carbide drill (point angles 𝜙=118° and 6 mm diameter) was used to drill a woven GFRP laminated squared plate with a length of 36.6 mm and different thicknesses. A produced temperature during drilling "heat affected zone (HAZ)" was measured by two different procedures using thermal IR camera and thermocouples. A thrust force and cutting torque were measured by a Kistler 9272 dynamometer. The delamination factors were evaluated by the image processing technique. Finite element model (FEM) has been developed by using LS-Dyna to simulate the drilling processing and validate the thrust force and torque with those obtained by experimental technique. It is found that, the present finite element model has the capability to predict the force and torque efficiently at various drilling conditions. Numerical parametric analysis is presented to illustrate the influences of the speeding up, coefficient of friction, element type, and mass scaling effects on the calculated thrust force, torque and calculation's cost. It is found that, the cutting time can be adjusted by drilling parameters (feed, speed, and specimen thickness) to control the induced temperature and thus, the force, torque and delamination factor in drilling GFRP composites. The delamination of woven GFRP is accompanied with edge chipping, spalling, and uncut fibers.

Drilling force and speed for mandibular trabecular bone in oral implant surgery

  • bin Kamisan, Mohammad Aimaduddin Atiq;Yokota, Kenichiro;Ueno, Takayuki;Kinoshita, Hideaki;Homma, Shinya;Yajima, Yasutomo;Abe, Shinichi;Takano, Naoki
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.1
    • /
    • pp.15-26
    • /
    • 2016
  • Based on a survey done recently in Japan, 30 percent of the serious accidents occurred in oral implant surgery were concerned with the mandibular canal and 3/4 of them were related to drilling. One of the reasons lies in the lack of the education system. To overcome this problem, a new educational system focusing on drilling the mandibular trabecular bone has been developed mainly for dental college students in the form of an oral implant surgery training simulator that enables student to sense the reaction force during drilling. On the other hand, the conventional system uses polymeric model. Based on these systems, two approaches were proposed; the evaluation by experienced clinicians using the simulator, and experimental works on the polymeric model. Focusing on the combination of the drilling force sensed and drilling speed obtained through both approaches, the results were compared. It was found that the polymeric models were much softer especially near the mandibular canal. In addition, the study gave us an insight of the understanding in bone quality through tactile sensation of the drilling force and speed. Furthermore, the clinicians positively reviewed the simulator as a valid tool.

Effects of the Point Angle on Drilling Characteristics Carbon Fiber Epoxy Composite Materials Using WC-drill Drilling (초경드릴을 이용한 탄소섬유 에폭시 복합재료의 드릴링 특성에 있어 선단각의 영향)

  • 김형철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.85-91
    • /
    • 1996
  • The drilling experiment of carbon fiber epoxy composite material with WC-drill has been done under the various cutting condition in order to minimize the problems occured in the material when being drilled. It has been comfirmed by a frequencyanalysis of the cutting force signals that the variation of cutting force resulted from the periodic variation of the angle between the rotating drill and the stacking angle of the carbon fiber. The drilling experiment has been done with several drills having different point angles and the drilling characteristics, like the effects such that change in the point angle influences the cutting force and the external surface condition, was evaluated.

  • PDF