• Title/Summary/Keyword: drill

Search Result 886, Processing Time 0.027 seconds

Effects of Drill Widths and Nitrogen Application Levels in Early Spring on the Growth Characteristics and Seed Productivity of Orchardgrass (Dactylis glomerata L.) (휴폭 및 이른 봄 질소비료 시용량이 오차드그라스의 생육특성 및 종자생산에 미치는 영향)

  • 최기준;정의수;임용우;임영철;김기용;성병렬;김맹중;박근제
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.23 no.2
    • /
    • pp.107-114
    • /
    • 2003
  • Growth characteristics and seed productivities of orchardgrass "Hwabsung 2 Ho" cultivated for seed production were examined in the NLRI from 2000 to 2002. The experimental design was a split-plot arrangement with three replications. The main-plots were three drill widths of 15, 30 and 45cm, and subplots were four nitrogen application levels of 45, 90, 135 and 180kg/ha in early spring. Lodging was less in 45cm of drill width than in 15 and 30cm and was not severe by 90kg per ha of nitrogen including 45cm of drill width. Number of panicles per $1\m^2$ was tended to be more in 15cm of drill width than in 30 or 45cm. Among 45cm of drill widths. 45kg per ha of nitrogen had most numerous panicles. Panicle length, number of 1st branch, weight of 1,000 grain, and germination of 30 or 45cm of drill width showed better characters than that of 15cm. Seed yield was not statistical different among the treatments but was some more in 30cm of drill width, and was tended not to be different among nitrogen levels. Therefore, considering lodging tolerances, seed yield components, and mechanizations, treatment with 45cm of drill width including 45kg per ha of nitrogen in early spring was better than other treatments for orchardgrass seed production.

PRIMARY STABILITY OF IMPLANTS IN ILIUM OF CADAVER BY THE METHODS OF RECIPIENT SITE PREPARATION (사체의 장골에서 수용부 형성방법에 따른 임플란트 일차 안정성)

  • Sim, Jung-Woo;Cho, Jin-Yong;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.2
    • /
    • pp.180-186
    • /
    • 2008
  • Purpose: This study was performed to evaluate the effect of the implant recipient site preparation methods on primary stability of implants with the instruments of $Osstell^{TM}$ and $Periotest^{(R)}$ in the iliac bone of cadaver. Methods and materials: The 8 iliac bones in 4 cadavers and implants treated with resorbable blasting media (RBM) were used. $Periotest^{(R)}$ (Simens AG, Germany) and $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used to measure primary stability of implants. Implants were inserted into the iliac crest of the cadaver. In control group, the recipient site was prepared according to the manufacturer's recommendation: 1.8 mm guide drill, 2.0 mm initial drill, 2.7 mm pilot drill, 2.7 mm twist drill, 3.0 mm twist drill, 3.3 mm pilot drill, 3.3 mm twist drill, and 3.3 mm countersink drill as well as tapping drill were used in order. In the group 1, implant recipient sites were prepared by sequentially drilling from 1.8 mm guide drill to 3.0 mm twist drill and then inserted implants without countersinking and tapping. In the group 2, implant recipient sites were prepared to 3.0 mm twist drill and countersink drill and then inserted implants without tapping. In the group 3, the sites were prepared to 3.0 mm twist drill and countersink drill as well as tapping drill. In the group 4, the sites were prepared to 3.3 mm twist drill. In the group 5, the sites were prepared to 3.3 mm twist drill and countersink drill. A total of 60 implants were placed (n=10). The stability was measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally and buccolingually. To compare the mean stability of each group statistically, One-way ANOVA was used and correlation of instrument were analyzed using SPSS 12.0. The results obtained were as follows; 1. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ buccolingually showed the highest, and there are significant difference statistically between control group and experimental group 1,2,4 in each instruments respectively (p<0.05). 2. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally showed the highest. There are significant difference statistically between control group and all experimental groups in $Osstell^{TM}$, and between control group and experimental group 1,2,3,4 (p<0.05). 3. There are high correlation between the measurements of $Osstell^{TM}$ and $Periotest^{(R)}$ (p<0.05). Conclusion: These results indicate that the primary stability of implant can be obtained by the recipient sites preparation with smaller diameter drill than that of implant or minimal drilling.

A Study on the Controller of Core-Drill for Concrete-Wall (콘크리트벽 천공용 코어드릴의 제어기에 관한 연구)

  • Kim, J.S.;Lee, H.G.;Nam, S.B.;Ma, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.191-193
    • /
    • 2006
  • We use electric drill for cutting wood. In electric drills, there is the core-drill that bores concrete-wall. The core-drill is used in construction or remodeling areas. Therefore we require safety in working with the core-drill. In this paper, new controller of core-drill for concrete-wall is proposed. Experimental results show the validity of the proposed controller.

  • PDF

A Study on the Detection of the Abnormal Tool State for Neural Network in Drilling (신경망에 의한 공구 이상상태 검출에 관한 연구)

  • Shin, Hyung-Gon;Kim, Tae-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.821-826
    • /
    • 2001
  • Out of all metal-cutting processes, the hole-making process is the most widely used. It is estimated to be more than 30% of the total metal-cutting process. It is therefore desirable to monitor and detect drill wear during the hole-drilling process. One important aspect in controlling the drilling process is monitoring drill wear status. Accordingly, this paper deals with Basic system and Online system. Basic system comprised of spindle rotational speed, feed rates, thrust, torque and flank wear measured tool microscope. Online system comprised of spindle rotational speed, feed rates, AE signal, flank wear area measured computer vision. On-line monitoring system does not need to stop the process to inspect drill wear. Backpropagation neural networks (BPNs) were used for on-line detection of drill wear. This paper deals with an on-line drill wear monitoring system to fit the detection of the abnormal tool state.

  • PDF

Development of a Drill Tool for CFRP Machining and Evaluation of Drilling Processing (탄소섬유 강화 복합재 가공용 드릴 공구 개발 및 홀 가공성 평가)

  • Sa, Min-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.3
    • /
    • pp.8-13
    • /
    • 2020
  • Carbon fiber-reinforced plastics (CFRPs) are extremely strong and light fiber-reinforced plastics containing carbon fibers. CFRPs can be expensive to produce, but are commonly used wherever high strength-to-weight ratio and rigidity are required, such as in the aerospace, automotive, and ship superstructure industries. In CFRP drilling, the tool performance greatly varies depending on the tool shapes, cutting conditions, and diamond coating. This study developed a new type of tungsten carbide drill with multi-blade edges to evaluate the surface quality of CFRP materials according to the coating thickness of diamond-coated drills. Experiments on tool wear, surface roughness, and burr formation were conducted. The bore exit quality of a 12 mμ -coated drill was better than that of a 6 mμ -coated drill. The superior effects of the 12 mμ -coated drill and the good surface quality of CFRP were also demonstrated.

Kinematics and Design of CNC Drill Grinding Machine (CNC 드릴 연삭기 구조 및 설계)

  • 강성균
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.555-559
    • /
    • 1996
  • Based on the general drill grinding mechanism, termed the helical grinding system, the conceptual design of 5 axes CNC drill grinding machine is proposed. Unique determination of the grinding parameters for precise production of the desired flank geometry is discussed by utilizing a mathematical model. Also, different combinations of grinding parameters are mentioned in order to produce various drill geometries (conical, cylindrical, and planar drill) on the single proposed CNC machine. A manual helical grinding machine has been fabricated and consequently helical drills have been ground in order to check the feasibility of the proposed grinding mechanism and its functionality.

  • PDF

Vibration Characteristics and Its Propagation Path Analysis of an Electric Drill (전동드릴의 진동특성 및 전파경로 해석)

  • 조윤수;김도현;최연선
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.9
    • /
    • pp.422-430
    • /
    • 2001
  • An electric drill is a handy tool used in a machine shop, which consists of motor, gear, bearing, shaft, and case, i.e., a gear driving system. Low level vibration and noise of the electric drill can bring the assurance of the quality and reliability of the machine. The vibration sources of the electric drill should be investigated for the reduction of the vibration and noise of the system. Through the experiments in laboratory and the various signal processing procedure for the measured vibration and sound signals, the characteristics of the vibration of the electric drill are investigated. And its propagation path is sought using partial coherence function.

  • PDF

A study on simplified procedure of enhanced designed implant drill (개선된 드릴 디자인을 적용한 간소화된 드릴링 과정에 관한 연구)

  • Yoon, Ji-Hoon;Jeon, Gye Rok;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.5
    • /
    • pp.368-376
    • /
    • 2015
  • Purpose : The objective of this research was to develop a more simplified drilling procedure with an enhanced implant drill. Materials and Methods : The drill enhanced design factors enabled implantation of Dia. 5.0mm fixture with only 2 times drilling which is more simplified drilling procedure. The enhanced drill was designed with 2 flutes, 2-phase or 3-phase formed drill tip and 25 degrees of helix angle. The proposed drilling procedure (2 times) was compared with a general drilling process (4 times) in terms of temperature changes, cutting time and ISQ value. Results : The simplified drilling procedure indicated less heat than a conventional drilling procedure (p<0.05). The enhanced drill showed significantly shorter drilling time than a conventional drill (p<0.05). On the other hand, higher insertion torque and ISQ value were observed on the the suggested drilling procedure than the conventional drilling procedure (p<0.05). Conclusion : A simplified drilling procedure with the newly designed drill could provide higher effectiveness and safety of dental implant operations under properly controlled external conditions, such as irrigation and RPM of drilling.

A Study on Evaluation System Development for Unexpected Scenarios Fire-Fighting Drill (무각본소방훈련 평가시스템 개발에 관한 연구)

  • Kim, Seung-Il;Lim, Jeong-Won;Kim, Jae-Kyeong;Kim, Jun-Woo
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.110-117
    • /
    • 2018
  • This study aims to overcome the problems of existing fire fighting drills and build a practical and effective fire fighting drill system to enhance emergency response capabilities. The unexpected scenarios fire fighting drill is to conduct drills with no scenarios and draw conclusions with quantified outcomes in real time, which provides the object evaluation system. The unexpected scenarios fire fighting drill is based on the IoT sensor-based drill evaluation system to suit individual requirement of drilling spots. This study also includes drill field test conducted to examine the applicability of the evaluation system for quantified outcomes. It is considered that the evaluation system of this paper will contribute to systematization and quantification of fire fighting drill, raise trainees' safety consciousness, and ultimately increase the actual fire fighting response capabilities.

A Study on Process Simulation Analysis of the Water Jet Cleaning Robot System for Micro Drill-bits (마이크로 드릴비트의 워터젯 세척 로봇시스템의 공정 시뮬레이션 분석에 관한 연구)

  • Kuk, Youn-Ho;Park, Sang-Rok;Park, Kee-Jin;Choi, Hyun-Jin
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.3
    • /
    • pp.291-297
    • /
    • 2015
  • A water jet cleaning robot system for micro drill bits is to refurbish micro drill bits used for the PCB manufacturing process. It can refurbish drill bits with the minimum diameter of ${\phi}0.15{\sim}0.075mm$ of which the total quantity have been discarded before. Micro drill bits with the minimum diameter of ${\phi}0.075mm$ can be cleaned by applying the water jet cleaning robot system out of the manual ultrasonic cleaning in the past for the cleaning equipment as the initial process in refurbishing. This study analyzed problems, while applying the apparatus mechanism for the workability such as the robot traces of Transfer Robot I and II, drill bit loading and unloading, and cleaning tasks in the water jet cleaning robot system in an effort to carry out simulations. In addition, the cleaning work process was optimized as the work process was verified in advance and the production quantity was analyzed through simulations.