• Title/Summary/Keyword: drift direction

Search Result 122, Processing Time 0.015 seconds

A Study on the Required Horsepower of Tugboats at Jeju Port for Car Ferries - Focusing on Car Ferry H - (카페리여객선 제주항 입출항 시 예선 사용 기준에 관한 연구 - 카페리여객선 H호를 중심으로 -)

  • Byung-Sun Kang;Chang-Hyun Jung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.209-216
    • /
    • 2024
  • Four accidents occurred between 2020 and 2022 after car ferries built according to a coastal passenger ship modernization plan collided with other ships or came into contact with the dock when entering Jeju Port. Accidents primarily occurred owing to careless ship handling and drift by wind during ship handled by herself using bow and stern thrusters without tugboats. Accordingly, in this study, we analyzed the collision accident focusing on car ferry H and the critical wind speed at which the ship cannot be controlled using its own power, tugboat operation plan in increasing wind speed were proposed based on the power required for the ship to berth parallel to the pier without a tugboat considering the external force and moment generated while the ship is berthing. A analysis of the critical wind speed of car ferry H by relative wind direction when using tugboats or not according to the loading status and the berthing speed, showed that one tugboat should be used at the stern when the lateral wind speed is over 10 m/s and two tugboats should be used when the lateral wind speed is over 14m/s berthing at Jeju port.

Influence of Column Aspect Ratio on the Hysteretic Behavior of Slab-Column Connection (슬래브-기둥 접합부의 이력거동에 대한 기둥 형상비의 영향)

  • Choi, Myung-Shin;Cho, In-Jung;Ahn, Jong-Mun;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2007
  • In this investigation, results of laboratory tests on four reinforced concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of column aspect ratio (${\beta}_c={c_1}/{c_2}$=side length ratio of column section in the direction of lateral loading $(c_1)$ to the direction of perpendicular to $c_1$) on the hysteretic behavior under earthquake type loading. The aspect ratio of column section was taken as $0.5{\sim}3\;(c_1/c_2=1/2,\;1/1,\;2/1,\;3/1)$ and the column perimeter was held constant at 1200mm in order to achieve nominal vertical shear strength $(V_c)$ uniformly. Other design parameters such as flexural reinforcement ratio $(\rho)$ of the slab and concrete strength$(f_{ck})$ was kept constant as ${\rho}=1.0%$ and $f_{ck}=40MPa$, respectively. Gravity shear load $(V_g)$ was applied by 30 percent of nominal vertical shear strength $(0.3V_o)$ of the specimen. Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, stiffness degradation and energy dissipation in the hysteresis loop, and steel and concrete strain distributions near the column support were examined and discussed in accordance with different column aspect ratio. Eccentric shear stress model of ACI 318-05 was evaluated with experimental results. A fraction of transferring moment by shear and flexure in the design code was analyzed based on the test results.