• Title/Summary/Keyword: drainage water volume

Search Result 88, Processing Time 0.024 seconds

Assessing the impact of urbanization on runoff and non-point source pollution using the GIS L-THIA (GIS L-THIA를 이용한 도시화에 따른 유출과 비점원오염 영향 평가)

  • Yun, La-Young;Kim, Dong-Hui;Gwon, Hyeok-Hyeon;Sin, Seung-Cheol;Son, Kwang-Ik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1802-1806
    • /
    • 2006
  • It is important to consider the effects of land-use changes on surface runoff, stream flow, and groundwater recharge. Expansion of urban areas significantly impacts the environment in terms of ground water recharge, water pollution, and storm water drainage. Increase of impervious area due to urbanization leads to an increase in surface runoff volume, contributes to downstream flooding and a net loss in groundwater recharge. Assessment of the hydrologic impacts or urban land-use change traditionally includes models that evaluate how land use change alters peak runoff rates, and these results are then used in the design of drainage systems. Such methods however do not address the long-term hydrologic impacts of urban land use change and often do not consider how pollutants that wash off from different land uses affect water quality. L-THIA (Long-Term Hydrologic Impact Assessment) is an analysis tool that provides site-specific estimates of changes in runoff, recharge and non point source pollution resulting from past or proposed land-use changes. It gives long-term average annual runoff for a land use configuration, based on climate data for that area. In this study, the environmental and hydrological impact from the urbanized basin had been examined with GIS L-THIA in Korea.

  • PDF

A Study on the Outlet Drain Discharge from Paddy Field (논의 배수물꼬의 유량에 관한 기초연구)

  • 최진규;김현영;손재권
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.2
    • /
    • pp.134-142
    • /
    • 1997
  • This study was performed to evaluate the drain runoff characteristics from one paddy field, and to provide the basic data required for the determination of flood discharge and unit drainage water for drainage improvement and farmland consolidation. For this purpose, under the assumption that drain discharge from paddy field was similar to outflow of reservoir, runoff model based on storage equation was applied to the experimental field, and simulated results were compared to the measured discharge at weir point. To estimate effective storage volume of paddy field with water depth, 4 regression formula were examined such as linear, exponential, power, and combined. From the observed runoff characteristics, it was shown to be 3.3~16.3${\ell}$/sec in weir discharge, 57.2~98% in runoff ratio, and relative error of simulated result was 3.0~39.4%, 8.5 ~56.0 % for peak flow and runoff ratio, respectively. Curve number by SCS method was calculated as mean value of 96.4 using measured rainfall and runoff data, it was considered relatively high because paddy field has generally flooding depth contrary to the upland watershed area.

  • PDF

Effects of Physical Characteristics on a Nutrient-Chlorophyll Relationship in Korean Reservoirs

  • Hwang, Soon-Jin;Jeon, Ji-Hong;Ham, Jong-Hwa;Kim, Ho-Sub
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.7
    • /
    • pp.64-73
    • /
    • 2002
  • This study was performed to evaluate effects of physical characteristics of both watershed and reservoir on nutrient-chlorophyll relationship in Korean reservoirs. Simple linear models were developed with published data in Korea including 415 reservoirs and 11 multi-purpose dams, and physico-chemical parameters of reservoirs and characteristics relationship of models were analyzed. Theoretical residence time in Korean reservoirs was strongly correlated with the ratio of TA/ST (drainage area + surface area / storage volume) in the logarithmic function. As a result of monthly nutrients-chlorophyll-a regression analysis, significant Chl-a-TP relationship appeared during May~July. The high Chl-a yields per total phosphorus appeared during this time (R$\^$2/=0.51, p<0.001, N= 1088). Chlorophyll-a demonstrated much stronger relationship with TP. than TN. Seasonal algal-nutrient coupling were closely related with N:P ratio in the reservoir water, and it was, in turn, dependent on the monsoon climatic condition (precipitation). Based on the results of regression analysis and high N:P ratio, a major limiting factor of algal growth appeared to be phosphorus during this time. Unlikely TA/ST ratio, DA/SA ratio (drainage area f surface area) was likely to influence directly on the nutrient-Chl-a relationship, indicating that if storage volume and inflowing water volume were the same, algal biomass could be developed more in reservoirs with large surface area. Thus, DA/SA ratio seemed to be an important factor to affect the development of algal biomass in Korean reservoirs. With low determination coefficient of TP-Chl-a relationship, our findings indicated not only nutrient (phosphorus) but also other physical factors, such as DA/SA ratio, may affect algal biomass development in Korean reservoirs, where actual residence time appears to be more closely related to reservoir surface area rather than storage volume.

Estimation of Storage Capacity for CSOs Storage System in Urban Area (도시유역 CSOs 처리를 위한 저류형시스템 설계용량 산정)

  • Jo, Deok Jun;Lee, Jung Ho;Kim, Myoung Su;Kim, Joong Hoon;Park, Moo Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.490-497
    • /
    • 2007
  • A Combined sewer overflows (CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available (which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a continuous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban drainage system used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range $3{\times}DWF$ (dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a decision of storage volume for CSOs reduction and water quality protection.

Constructed Wetland Design Method to Treat Agricultural Drainage from Tidal Reclaimed Paddy Areas (간척지 논 농업배수 처리에 적합한 인공습지 설계 기법)

  • Jang, Jeong-Ryeol;Shin, Yu-Ri;Jung, Ji-Yeon;Choi, Kang-Won
    • KCID journal
    • /
    • v.18 no.1
    • /
    • pp.4-17
    • /
    • 2011
  • The standard design methodology was suggested to construct wetland system for reducing non-point source pollution from Saemangeum reclaimed paddy land. To set for the design flow and concentrations, runoff and water quality survey were conducted during the irrigation period in 2008 at Gyehwa reclaimed paddy land located at near Saemangeum lake. It is rational that 1ha is the optimum constructed wetland size. To meet this size, the moderate drainage area of reclaimed paddy field was 50ha under the conditions that rainfall is 30mm, average runoff coefficient is 0.83, and runoff capture ratio is 0.6. At these condition, the runoff volume from 50ha was 10,520 $m^3/d$ including base flow during irrigation period. To select the optimum wetland system, several case studies were conducted by focusing on the tidal reclaimed land areas having wetland systems in Seokmun. Pond-Wetland system was selected as the standard model because of showing the highest reduction efficiency. Single variable regression equation were delivered to estimate effluent water concentrations from the designed wetland by using long-term monitoring data from the Seokmun experiment site. The effluent concentration from the designed wetland using these equation were showed moderately range.

  • PDF

A Study of Optimal-CSOs by Continuous Rainfall/Runoff Simulation Techniques (연속 강우-유출 모의기법을 이용한 최적 CSOs 산정에 관한 연구)

  • Jo, Deok Jun;Kim, Myoung Su;Lee, Jung Ho;Kim, Joong Hoon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1068-1074
    • /
    • 2006
  • For receiving water quality protection a control systems of urban drainage for CSOs reduction is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as storm-water detention storage is highly dependant on the temporal variability of storage capacity available as well as the infiltration capacity of soil and recovery of depression storage. For the continuous long-term analysis of urban drainage system this study used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model has evolved that offers much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. Runoff characteristics manifested the unique characteristics of the subject area with the infiltration capacity of soil and recovery of depression storage and was examined appropriately by sensitivity analysis. This study presented the average annual CSOs, number of CSOs and event mean CSOs for the decision of storage volume.

Construction and Operational Experiences of Engineered Barrier Test Facility for Near Surface Disposal of LILW (중.저준위 방사성폐기물의 천층처분을 위한 인공방벽 실증시험시설의 건설 및 운전 경험)

  • Jin-Beak Park;Se-Moon Park;Chang-Lak Kim
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.23-34
    • /
    • 2004
  • To validate the previous conceptual design of cover system, construction of the engineered barrier test facility is completed and the performance tests of the disposal cover system are conducted. The disposal test facility is composed of the multi-purpose working space, the six test cells and the disposal information space for the PR center. The dedicated detection system measures the water content, the temperature, the matric potential of each cover layer and the accumulated water volume of lateral drainage. Short-term experiments on the disposal cover layer using the artificial rainfall system are implemented. The sand drainage layer shows the satisfactory performance as intended in the design stage. The artificial rainfall does not affect the temperature of cover layers. It is investigated that high water infiltration of the artificial rainfall changes the matric potential in each cover layer. This facility is expected to increase the public information about the national radioactive waste disposal program and the effort for the safety of the planned disposal facility.

  • PDF

A Study on Outlet Damage Prediction of Pipe Culverts in Forest Road (임도 횡단배수구의 유출구 피해 예측에 관한 연구)

  • Kim, Myung Hwan;Hwang, Jin Seong;Yu, Young Min;Cha, Du Song
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.3
    • /
    • pp.278-286
    • /
    • 2018
  • This study examined the damage characteristics through investigation for a total of 10 factors (longitudinal position, crossing position, soil type, collecting well volume, outlet position, water apron material, waterway existence, pipe culvert diameter, pipe culvert gradient, pipe culvert height) affecting outlet damages of forest road cross drainage for forest roads in the Research Forest of Kangwon National University. We predicted outlet damages of forest road cross drainage for forest roads using a discriminant analysis Results showed that longitudinal position, crossing position, soil type and pipe culvert height did not affect damages caused to forest road cross drainage. Most influential factors affecting outlet damages were outlet position, waterway existence, pipe culvert diameter, pipe culvert gradient and collecting well volume, respectively. The discriminant ratio calculated from the developed discriminant function was 68.8% which is reasonably reliable.

A Fundamental Study on Vibrated Crushed-stone Pile for the Improvement of Liquefaction Resistance (액상화 방지를 위한 진동쇄석말뚝에 관한 기초적 연구)

  • 천병식
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.105-111
    • /
    • 2000
  • If a saturate sand is subjected to ground vibrations it tends to compact and decrease in volume. if drainage is unable to occur the tendency to decrease in volume results in an increase in pore water pressure and if the pore water pressure build up to the point at which it is equal to the overburden pressure the effective stress becomes zero the sand loses its strength completely. This phenomenon is called "Liquefaction" It is associated primarily but not exclusively with saturated cohesion soils. The attention and study on liquefaction have been growing since the earthquake in Niigita Japan in 1964. Many researchers on liquefaction effect have been carried out in many countries under the potential influence of earthquake including Japan. However little research on liquefaction has been reported in Korea because Korea has been considered to be safe from earthquake. The term "liquefaction" is only known among geotechnical engineers,. In this paper overview of liquefaction and the evaluation on the applicability of vibrated crushed-stone pile as a liquefaction prevention method are presented.ethod are presented.

  • PDF

Real-time urine monitoring system for intensive care patient using optical sensor (광센서를 이용한 실시간 중환자 요량감시 장치)

  • Kim, Jong-Myoung;Lee, Jin-Young;Hong, Joo-Hyun;Lim, Seung-Woon;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.81-85
    • /
    • 2008
  • This paper addressed real-time urine monitoring device for intensive care patients. The device was developed to detect and count each urine drop using optical sensor and calculate the current urine output volume and its hourly rate. In experiment, the water volume scale of drainage bottle was observed and compared with the count of the device so that the volume of each drop was found to vary with the dropping rate per minute. From this measurement, the relationship equation was derived to estimate the total water volume from the drop rate (correlation coefficient : r= 0.99). The developed device could be applied to count patient's urine drop successfully. Therefore, this device can be used to monitor intensive care patient's urine status in real-time.