• Title/Summary/Keyword: drainage facility

Search Result 142, Processing Time 0.022 seconds

Size Determination Method of Bio-Retention Cells for Mimicking Natural Flow Duration Curves (자연상태 유황곡선 보전을 위한 생태저류지 용량결정방법)

  • Lee, Okjeong;Jang, Suhyung;Kim, Hongtae;Kim, Sangdan
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.424-431
    • /
    • 2016
  • LID facilities like bio-retention cells is applied to manage stormwater. LID concept becomes an important part in stormwater management, and the clear understanding of hydrologic performance and hydrologic impact on the corresponding catchment has been needed. In this study, the application of flow duration curves as design strategy is investigated. Bio-retention cells like many LID facilities are installed to reproduce natural hydrologic processes. In this study, the attempt to determine the size of a bio-retention cell is carried out to satisfy the flow duration criteria. From the results, it is shown that "5 mm * the area of a target catchment" which is the current facility design capacity is valid for the drainage area with 20-30% impervious rate. In the 100% impervious catchment where LID facilities are typically installed, the design capacity to intercept stormwater of approximately 47 mm depth is required to reproduce natural flow duration curves. This means that about 11% of the target catchment area should be allocated as a bio-retention cell. However, the criteria of the design capacity and facility surface area should be set at the possible implementation conditions in reality, and site-specific hydrologic characteristics of a target catchment should be considered.

Evaluation of Cu Removal from Mine Water in Passive Treatment Methods : Field Pilot Experiments (자연정화 기반의 현장 파일럿 실험을 통한 광산배수 구리 정화효율 평가)

  • Oh, Youn Soo;Park, Hyun Sung;Kim, Dong Kwan;Lee, Jin Soo;Ji, Won Hyun
    • Economic and Environmental Geology
    • /
    • v.53 no.3
    • /
    • pp.235-244
    • /
    • 2020
  • Copper (Cu), one of the main contaminants in the mine drainage from the closed mine area, needs to be removed before exposed to environment because of its toxicity even in the low concentration. In this study, passive treatment based field pilot experiments using limestone and compost media were conducted during 9 months for enhancing Cu removal efficiency of the mine water treatment facility of S mine located in Goseong, Gyeongsangnam-do in South Korea. The pH increase and Cu removal efficiency showed high value at Successive Alkalinity Producing System ( SAPS) > Reducing and Alkalinity Producing System (RAPS) > limestone reactor in a sequence. The compost media using in SAPS and RAPS contributed to raise pH by organic material decomposition with generating alkalinity, thus, Cu removal efficiency increased. Also, experimental results showed that Cu removal efficiency was proportional to pH increase, meaning that pH increase is the main mechanism for Cu removal. Moreover, Sulfate Reduction Bacteria (SRB) was identified to be most activated in SAPS. It is inferred that the sulfate reduction reaction also contributed to Cu removal. This study has the site significance in that the experiments were conducted at the place where the mine water generates. In the future, the results will be useful to select the more effective reactive media used in the treatment facility, which is most appropriate to remediate mine water from the S mine.

Analysis of the Discharge Characteristics of Non-point Pollutants from the Interception Facilities according to Rainfall Conditions (강우조건에 따른 차집시설에서의 비점오염물질 유출특성분석)

  • Lin, Zi-Yu;Eun, Beomjin;Heo, Jeong Sook;Choi, I Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • This study was carried out to understand the water quality characteristics of the initial stormwater runoff and the origin of soluble pollutants according to various rainfall conditions from a non-point source reducing facility. The water sample from this study was collected among 10 collection facilities in the G-drainage area. Specifically, five of the collection points including #1, #5, #8, #9, and #10 were reported with unknown water inflow even during non-rain conditions. The leakage characteristics of non-point pollutants from the collection facilities were then able to identify accordingly. The water quality characteristics of the stormwater runoff from the collection facilities were strongly affected by the amounts of rainfalls. The average concentrations of EC, BOD, TOC, and TN during non-rain were found to be higher than their concentrations during rain; on the other hand, the average concentrations of DO were found to be lower than its concentrations during rain. In addition, the distribution of organic components existing in the effluent of collection facilities were identified based on the dissolved organic matter analysis. In summary, the stormwater runoff was highly affected by pollutants flowing from the surrounding environment, and the amounts of hard-to-decompose humic substances were greatly increased in the collection facilities due to rain.

A Study on the Role of Public Sewage Treatment Facilities using Wastewater-based Epidemiology (하수기반역학을 적용한 공공하수처리시설 역할 재정립)

  • Park Yoonkyung;Yun Sang-Lean;Yoon Younghan;Kim Reeho;Nishimura Fumitake;Sturat L. Simpson;Kim Ilho
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.3
    • /
    • pp.231-239
    • /
    • 2023
  • Public sewage treatment facilities are a necessary infrastructure for public health that treat sewage generated in cities and basin living areas and discharge it into rivers or seas. Recently, the role of public sewage treatment is receiving attention as a place of use of wastewater-based epidemiology (WBE), which analyzes human specific metabolic emissions or biomarkers present in sewage to investigate the environment to which the population is exposed in the water drain. WBE is mainly applied to investigate legal and water-law drug use or to predict and analyze the lifestyle of local residents. WBE has also been applied to predict and analyze the degree of infectious diseases that are prevalent worldwide, such as COVID-19. Since sewage flowing into public sewage treatment facilities includes living information of the population living in the drainage area, it is easy to collect basic data to predict the confirmation and spread of infectious diseases. Therefore, it is necessary to establish a new role of public sewage treatment facilities as an infrastructure necessary for WBE that can obtain information on the confirmation and spread of infectious diseases other than the traditional role of public sewage treatment. In South Korea, the sewerage supply rate is about 95.5% and the number of public sewage treatment facility is 4,209. This means that the infrastructure of sewerage is fully established. However, to successfully drive for WBE , research on monitoring and big-data analysis is needed.

Centrifuge Model Experiments for Lateral Soil Movements of Piled Bridge Abutments. (교대말뚝기초의 측방유동에 관한 원심모형실험)

  • Choi, Dong-Hyurk;Jeong, Gil-Soo;Park, Byung-Soo;Yoo, Nam-Jae
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.63-71
    • /
    • 2005
  • This paper is an experimental result of investigating lateral soil movements at piled bridge abutments by using the centrifuge model facility. Three different centrifuge model experiments, changing the methods of ground improvement at bridge abutment on the soft clayey soil (no improvement, preconsolidation and plastic board drains (PBD), sand compaction pile (SCP) + PBD), were carried out to figure out which method is the most appropriate for resisting against the lateral soil movements. In the centrifuge modelling, construction process in field was reconstructed as close as possible. Displacements of abutment model, ground movement, vertical earth pressure, cone resistance after soil improvement and distribution of water content were monitored during and after centrifuge model tests. As results of centrifuge model experiments, preconsolidation method with PBD was found to be the most effective against the lateral soil movement by analyzing results about displacements of abutment model, ground movement and cone resistance. Increase of shear strength by preconsolidation method resulted in increasing the resistance against lateral soil movement effectively although SCP could mobilize the resistance against lateral soil movement. It was also found that installment with PBD beneath the backfill of bridge abutment induced effective drainage of excess pore water pressure during the consolidation by embanking at the back of the abutment and resulted in increasing the shear strength of clay soil foundation and eventually increasing the resistance of lateral soil movement against piles of bridge abutment.

  • PDF

Analysis of Infiltration Trench Facility for Runoff Reduction Effect (침투트렌치 시설의 유출저감 효과 분석)

  • Yeon, Jong Sang;Jang, Young Su;Shin, Hyun Suk;Kim, Eung Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5813-5819
    • /
    • 2014
  • LID planning and application has been actively developed to reduce the runoff volume at increased impervious areas due to rapid urbanization. In this study, a performance and applicability evaluation was performed in an infiltration trench using the SWMM model, based on the experimental conditions for infiltration trenches. The infiltration trench application area was applied to 5~15% of the drainage area. The SWMM results of discharge and the BOD reduction efficiency were analyzed at a peak discharge of 45.7~61.9%, total discharge of 47.2~62.3%, and BOD load of 52.3~55.3. The discharge and BOD was estimated to be 12~24% higher and 37~38% smaller than the experimental results. This study can help in the application and performance evaluation of infiltration trenches.

Assessing Compliance with the Wildlife Crossing Guideline in South Korea

  • Woo, Donggul;Park, Heebok;Seo, Hyeong-Soo;Moon, Ho-Gyeong;Song, Euigun;Lim, Anya;Choi, Tae-Young
    • Journal of Forest and Environmental Science
    • /
    • v.34 no.2
    • /
    • pp.176-179
    • /
    • 2018
  • To restore the connectivity of fragmented habitats, 415 wildlife crossings have been built between 1998 and 2014 in South Korea. However, their effect on wildlife conservation is still in doubt. As a first step to examine the effectiveness, our study aims to assess compliance with the guideline for wildlife crossing construction and management, developed by the Ministry of Environment Korea that provides fundamental information to understand the status and the problem of wildlife crossings in Korea and thus to provide practical guidance for the improvement. According to our survey, the Korea National Park Service complied with the guideline best (62.5%) while local government followed the guideline least (46.1%). In addition, the compliance rate was the highest for wildlife crossings in national roads (53.6%) followed by highways (53.2%) and local and municipal roads (52.2%). For the overpass wildlife crossings, the compliance rates for installation of an escaping facility in the drainage and prevention of pedestrian and vehicle access were particularly low. In case of underpass wildlife crossings, small ditches for amphibians and reptiles were not sufficient, and the linkage between wildlife fences and underpass were weak. In order to ensure the effectiveness of wildlife crossings, the effort to increase the compliance rate with the guideline is critical, and mandating the guideline could be a practical way to enforce the compliance.

A Study on Filed Application of Electro-Osmosis Soil Improvement Method with Nano-Coated Plastic Drain Baord (나노 코팅된 PDB를 이용한 동전기 지반개량 공법의 현장 적용성에 관한 연구)

  • Ahn, Sangro;Ahn, Kwangkuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.10
    • /
    • pp.5-11
    • /
    • 2018
  • The PBD (Plastic Board Drain) method is one of effective ground improvement methods on the soft dredging reclamation ground. This method has outstanding economic efficiency and constructability, and it is widely used for the soft ground improvement. However, the PBD method reduces permeability and drainage capacity of the ground due to the long construction period. Therefore, the nano coated Plastic drain board (PDB) was developed to solve problems. It is the non-metallic electrode and improves the weakness of the PBD method by using electric force of the electro-osmosis method. Various researches have been conducted to apply the nano coated PDB, but these researches were limited to model tests in laboratory. In this study, model and field tests were conducted to assess field applicability of the nano coated PDB. The result showed that the nano coated PDB had the better effect on the ground improvement compared to the normal PDB.

A Study on Improvement of Distribution Facility in Wholesale Agricultural Products Market

  • Gal, Won-Mo;Kwon, Ki-Tae;Lee, Woo-Sik;Choi, Eun-Mee;Kwon, Lee-Seung;Seong, Seung-Hwan;Kwon, Woo-Taeg
    • Journal of Distribution Science
    • /
    • v.16 no.2
    • /
    • pp.53-65
    • /
    • 2018
  • Purpose - The purpose of this study is to investigate the effect of gamma - irradiation on the effluent from food distribution in the large agricultural and marine products market. This study will contribute to the distribution process as well as the agricultural and fishery distribution facilities. Research design, data, and methodology - In order to reduce the odor, the smell was examined in the anaerobic digestion process by irradiating gamma rays to the wastewater of mixed food discharged from a large restaurant. An odor determination panel list was constructed to determine if the odor was present in the air dilution drainage and the odor concentration was analyzed by instrumental analysis. Results - It was confirmed that the sulfur content increased gradually from 3 months. Ammonia decreased from 33.57ppm at the initial measurement to 4.12 ppm at the end of the experiment. Methane production was highest at 100kGy when exposed to gamma rays of 0-200kGy at pH 12. In other words, it is considered that gamma irradiation doses are most effective at 100kGy and are suitable for large capacity wastewater treatment facilities in terms of economic feasibility. Conclusions - In pre-treatment of compound food wastewater, gamma irradiation is most cost effective when examined at 100kGy. The economic efficiency of the pre-treatment method by gamma irradiation is much higher than the wastewater treatment in the large-scale agricultural and marine products distribution market.

An Experimental Study on Permeability Characteristics of Blast Furnace Slag Concrete (고로슬래그 콘크리트의 투수특성에 관한 실험적 연구)

  • Paik, Shinwon;Oh, Daeyoung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.3
    • /
    • pp.9-12
    • /
    • 2013
  • The pavement is generally used on the highways, local loads, roads for bicycle riding and neighborhood living facility such as parking lot, plaza, park and sports facilities. However, the pavement material that is usually used on the most of roads is impermeable asphalt-concrete and cement-concrete. If the pavement material is impermeable, many problems can be happened on the drainage facilities in the rainy season. Additionally, a lot of rainwater on the pavement surface cannot permeate to the underground and flows to the sewage ditch, stream and river, etc. If a lot of rainwater flows at once, the floods can be out along the streams and rivers. So, underground water can be exhausted. Micro organisms cannot live in the underground. Recently, many studies has been conducted to exploit the permeable concrete that has high performance permeability. However, it is required to develop the permeable concrete which has high strength and durability. In this study, permeable and strength tests were performed to investigate the permeable characteristics of porous concrete according to fine aggregate content and substitution ratio of blast furnace slag. In this test, crushed stones with 10~20 mm and sand with 5~10 mm were used as a coarse aggregate and a fine aggregate respectively. The substitution ratio of blast furnace slag to cement weight is 0 %, 15 %, and 30 %. The ratio of fine aggregate to total aggregate is 0 %, 18 %, and 35 %. As a result, permeability coefficient was decreased according to fine aggregate ratio of total aggregate. Compressive strength was also decreased according to substitution ratio of blast furnace slag.